• Title/Summary/Keyword: 검체

Search Result 654, Processing Time 0.026 seconds

Improvement of an Simultaneous Determination for Clenbuterol and Ractopamine in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 clenbuterol과 ractopamine의 동시 분석법 개선)

  • Cho, Yoon-Jae;Chae, Young-Sik;Kim, Jae-Young;Kim, Hyung-Soo;Kang, Ilhyun;Do, Jung-Ah;Oh, Jae-Ho;Kwon, Kisung;Chang, Moon-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.25-33
    • /
    • 2013
  • Clenbuterol and ractopamine, which are ${\beta}$-agonists, have been misused as a growth promoting agent in meat producing animals. Clenbuterol was banned for veterinary drug in Korea because of its problems regarding safety. Due to their adverse effects, such as cardiovascular and central nervous diseases on human health proper control and monitoring should be conducted. The existing analytical method of clenbuterol and ractopamine in the Food code was improved through our present study. The bovine muscle samples were subjected to enzymatic hydrolysis, extracted with ethyl acetate and defatted by hexane-methanol partitioning. A molecular imprinted polymer (MIP) solid phase extraction cartridge was used for clean-up and LC-MS/MS was operated in positive multiple reaction monitoring (MRM). Clenbuterol-$d_9$ and ractopamine-$d_3$ were used as an internal standard. The renewed method was validated according to the CODEX guideline. The limits of quantitation for clenbuterol and ractopamine were 0.2 and 0.5 ${\mu}g/kg$, respectively. The mean recoveries ranged in 104.2-113.5% for clenbuterol and in 107.6-118.1% for ractopamine. The improved method was able to save both time and expenses.

Genotype Frequency of Human Papillomavirus Determined by PCR and DNA Sequencing in Korean Women

  • Lee, Kyung-Ok;Seong, Hye-Soon;Chung, Soo-Jin;Jung, Na-Young;Lee, Hye-Jung;Kim, Kyung-Tae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.99-104
    • /
    • 2006
  • Human Papilloma viruses (HPVs) are etiological agents for cervical cancer and are classified into low- and high-risk categories. The aim of this study was to determine the frequency of the HPV genotype in the HPV screening test of Korean women using PCR-direct sequencing. Consensus primers of L1 legion were used for the amplification of HPV DNA and the PCR products (450 bps) obtained were analyzed by automatic sequencing. Sequences were compared with those in GenBank by using the BLAST program. Cervical swab samples of 3,978 women (20-73 years) were tested and the average age was 37.6 years. In this study, 1,174 samples were HPV positive out of 3,978 cervical swab samples screened (29.5%) and 136 samples (11.6%) showed a double infection. A total of 1,310 HPV genotypes were analyzed. The HPV positive rate was the lowest in the 20 years group (69.5%) and most of the samples of the > 60 years group were found HPV positive. Among thirty seven different HPV types identified by sequencing, 21 were HPV high risk types and 16 HPV low risk types were 69.8% (914/1,310) and 26.0% (340/1,310), respectively. In HPV high-risk types, 16 (13.21%), was the most frequently found. HPV 53 (9.62%) and 58 (9.24%) were also frequently found. This group was followed by HPV types 70 (5.50%), 33 (4.73%), 66 (4.20%), 18 (4.05%), 52 (4.05%), 31 (3.97%) and 56 (3.51%) in descending order of frequency. Among HPV low-risk types, 62 (4.20%), 6 (3.59%), 81 (3.59%), 84 (3.51%), and 11 (2.6%) were frequently found. In conclusion, PCR-direct sequencing could be used for quick and reliable typing of known and novel HPVs from clinical specimens. This data could be useful for epidemiological study of HPV and it also allows type-specific follow-up of women who have been treated for cervical intraepithelial neoplasia.

  • PDF

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

Report on the External Quality Assessment Scheme of Hepatitis Viral Markers in Korea, (2016-2017) (간염바이러스 항원항체검사 신빙도조사 결과보고 (2016-2017))

  • Cho, Eun-Jung;Choi, Ae Ran;Ryu, Ji Hyeong;Yun, So Jeong;Lee, Woochang;Chun, Sail;Min, Won-Ki;Oh, Eun-Jee
    • Laboratory Medicine and Quality Assurance
    • /
    • v.40 no.2
    • /
    • pp.51-69
    • /
    • 2018
  • As part of the immunoserology program of the Korean Association of External Quality Assessment Service, we organized two trials on the external quality assessment of hepatitis viral markers in 2016 and 2017. The hepatitis viral antigens and antibodies program consisted of 10 test items. We delivered two and three types of pooled sera specimens to 965 and 965 institutions for the first and second trials of external proficiency testing in 2016, respectively. The number of participating laboratories was 915 (94.8%) and 913 (95.0%) in the first and second trials in 2016, respectively. We also delivered three kinds of pooled sera specimens to 936 and 1,015 institutions for the first and second trials of external proficiency testing in 2017, respectively. The number of participating laboratories was 920 (98.3%) and 996 (98.1%) in the first and second trials in 2017, respectively. The most commonly tested items were hepatitis B surface antigen, followed by the antibodies to hepatitis B surface antigen, anti-hepatitis C virus, hepatitis B envelope antigen, antibodies to hepatitis B envelope antigen, anti-hepatitis A virus and antibodies to hepatitis B core antigen. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay and the electrochemiluminescence immunoassay, but they yielded a few-false positive results due to the matrix effect. The immunochromatographic assay yielded false-negative results for anti-hepatitis A virus due to low sensitivity. Continuous improvement in the quality of viral hepatitis testing through participation in the survey seems necessary.

Diagnostic Availability of Estrogen Receptor Alpha mRNA on Cervical Cancer Tissue (자궁경부암 조직에서 에스트로겐 수용체 알파 mRNA의 진단적 유용성)

  • Kim, Geehyuk;Yu, Kwangmin;Kim, Jungho;Kim, Seoyong;Park, Sunyoung;Ahn, Sungwoo;Lee, Ji-Young;Kim, Sunghyun;Park, Ho-Hyun;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.449-456
    • /
    • 2018
  • Cervical cancer is the fourth most frequently diagnosed cancer in women worldwide. In lower Human Development Index countries, it has the second highest incidence and mortality among cancer in women. Therefore, better diagnosis and treatment systems are needed. Among them, estrogen receptor alpha ($ER-{\alpha}$) mRNA expression has been analyzed with RT-qPCR since several studies reported that $ER-{\alpha}$ is necessary in the maturation of the uterus and is related to cervical cancer. In this study, $ER-{\alpha}$ quantitative analysis was performed on various lesions and normal tissue samples. Based on the receiver operating characteristic (ROC) curve, its sensitivity and specificity were 85% and 75%, respectively, showing higher or similar results to those of conventional HPV tests. In addition, its expression level was analyzed with clinical information. With regression analysis, the R square value between the $ER-{\alpha}$ mRNA expression level and menopause status was 0.5041, indicating a strong correlation. This study was performed as part of a pilot study and suggests that $ER-{\alpha}$ is related to carcinogenesis. Future studies will examine other hormones and menopausal factors with a larger sample size.

Evaluation of Commercial Complementary DNA Synthesis Kits for Detecting Human Papillomavirus (인유두종바이러스 검출을 위한 상용화된 cDNA 합성 키트의 평가)

  • Yu, Kwangmin;Park, Sunyoung;Chang, Yunhee;Hwang, Dasom;Kim, Geehyuk;Kim, Jungho;Kim, Sunghyun;Kim, Eun-Joong;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.3
    • /
    • pp.309-315
    • /
    • 2019
  • Cervical cancer is the fourth most common malignant neoplasm in women worldwide. Most cases of cervical cancer are caused by an infection by the human papillomavirus. Molecular diagnostic methods have emerged to detect the HPV for sensitivity, specificity, and objectivity. In particular, real-time PCR has been introduced to acquire a more sensitive target DNA or RNA. RNA extraction and complementary DNA synthesis are proceeded before performing real-time PCR targeting RNA. To identify an adequate and sensitive cDNA synthesis kit, this study evaluated the two commonly used kits for cDNA synthesis. The results show that the $R^2$ and efficiency (%) of the two cDNA synthesis kits were similar in the cervical cancer cell lines. On the other hand, the Takara kit compared to Invitrogen kit showed P<0.001 in the $10^2$ and $10^3$ SiHa cell count. The Takara kit compared to the Invitrogen kit showed P<0.001 in the $10^1$ and $10^2$ HeLa cell count. Furthermore, 8, 4, 2, 1, and 0.5 ml of forty exfoliated cell samples were used to compare the cDNA synthesis kits. The Takara kit compared to the Invitrogen kit showed P<0.01 in 8, 4, and 1 ml and P<0.05 in 0.5 mL. The study was performed to identify the most appropriate cDNA synthesis kit and suggests that a cDNA synthesis kit could affect the real-time PCR results.

Molecular Epidemiological Analysis of Food Poisoning Caused by Salmonella enterica Serotype Enteritidis in Gyeongnam Province of Korea (2021년 경남지역 Salmonella enterica serotype Enteritidis 원인 식중독의 분자역학적 특성 분석)

  • Hye-Jeong Jang;Yon-kyoung Ha;Sun-Nyoung Yu;So-young Kim;Jiyeon Um;Gang-Ja Ha;Dong-Seob Kim;Sang-Yull Lee;Soon-Cheol Ahn
    • Journal of Life Science
    • /
    • v.33 no.1
    • /
    • pp.56-63
    • /
    • 2023
  • In this study, two cases of food poisoning caused by Salmonella that occurred in Gyeongsangnam-do in September 2021 are reported. One of the outbreaks occurred in a school and the other in a company. The molecular epidemiological characteristics of the isolated strains in the two outbreaks were analyzed. In the case of the school outbreak, 29 (4.9%) of 588 individuals experienced diarrhea and abdominal pain. As a result of a test of 36 individuals (patients, n=29; cook workers, n=7), Salmonella enterica serotype Enteritidis was detected in 17 (47.2%) patients, suggesting this serotype was the principal cause. Meanwhile, Salmonella spp. were not detected in 35 food and environmental samples. In the company outbreak, 87 (3.0%) of 2,900 individuals who had intaked from the same source experienced diarrhea, abdominal pain, and fever. In a test of 50 individuals (patients, n=40; cook workers, n=10), S. Enteritidis was detected in 28 patients (56.0%). Also, Vibrio cholerae (NAG) was detected in four patients with S. Enteritidis, and V. cholerae (NAG) only was detected in one patient. Salmonella spp. were not detected in 118 preserved foods, but S. Enteritidis was detected in one eaten food (toast) delivered in group by the company. Through PFGE genetic homology analysis of the isolated strains, all S. Enteritidis detected in patients and consumed foods were the same type. It seems that these S. Enteritidis isolates were the same type as detected in a previous school outbreak and in patients of group food poisoning in other regions, leading to an enhanced problem of food poisoning and epidemiology. Our analytic results can provide data for epidemiological management and food poisoning prevention based on molecular characteristics.

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.

Clinical Characteristics and Comparison of the Various Methods Used for the Diagnosis of the New Influenza A Pandemic in Korea (한국에서의 2009 신종 인플루엔자 A의 임상양상과 다양한 진단 방법들의 비교)

  • Kwon, Min Jung;Lee, Chang Kyu;Roh, Kyoung Ho;Nam, Myung Hyun;Yoon, Soo Young;Lim, Chae Seung;Cho, Yun Jung;Kim, Young Kee;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 2011
  • Background: Laboratory diagnosis of new influenza A (H1N1) is crucial for managing patients and establishing control and prevention measures. We compared the diagnostic accuracies of the real time RT-PCR (rRT-PCR) test recommended for the confirmation of the new flu and the viral culture method used conventionally for viral disease with that of the rapid antigen test (RAT). Methods: We performed RAT, R-mix culture, and real-time PCR by using 861 respiratory samples collected from December 2009 to January 2010 and evaluated the abilities of these methods to detect new influenza A. The relationship among the positive rates of RAT, grades of culture, and the cycle threshold (Ct) values of rRT-PCR was also evaluated. Results: Of the 861 patients, 308 (35.8%) were diagnosed with new influenza A. The sensitivities, specificities, positive predictive values, and negative predictive values of the tests were respectively as follows: 59.7%, 99.5%, 98.4%, and 81.6% for RAT; 93.2%, 100%, 100%, and 96.3% for R-mix culture; and 95.8%, 100%, 100%, and 97.7% for rRT-PCR. Samples with weak positive grade in culture and those with Ct values of 30-37 in rRT-PCR showed positivities as low as 25.3% and 2.3% in RAT, respectively. The hospitalization rate and death rate of the confirmed patients were 3.2% and 0.3%, respectively, and gastrointestinal symptoms were observed in 7.2% of the patients. Conclusions: R-mix culture and rRT-PCR tests showed excellent reliability in the diagnosis of new influenza A and could be very useful, especially for samples with low viral load.

Establishment of Analytical Method for Dichlorprop Residues, a Plant Growth Regulator in Agricultural Commodities Using GC/ECD (GC/ECD를 이용한 농산물 중 생장조정제 dichlorprop 잔류 분석법 확립)

  • Lee, Sang-Mok;Kim, Jae-Young;Kim, Tae-Hoon;Lee, Han-Jin;Chang, Moon-Ik;Kim, Hee-Jeong;Cho, Yoon-Jae;Choi, Si-Won;Kim, Myung-Ae;Kim, MeeKyung;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2013
  • BACKGROUND: This study focused on the development of an analytical method about dichlorprop (DCPP; 2-(2,4-dichlorophenoxy)propionic acid) which is a plant growth regulator, a synthetic auxin for agricultural commodities. DCPP prevents falling of fruits during their growth periods. However, the overdose of DCPP caused the unwanted maturing time and reduce the safe storage period. If we take fruits with exceeding maximum residue limits, it could be harmful. Therefore, this study presented the analytical method of DCPP in agricultural commodities for the nation-wide pesticide residues monitoring program of the Ministry of Food and Drug Safety. METHODS AND RESULTS: We adopted the analytical method for DCPP in agricultural commodities by gas chromatograph in cooperated with Electron Capture Detector(ECD). Sample extraction and purification by ion-associated partition method were applied, then quantitation was done by GC/ECD with DB-17, a moderate polarity column under the temperature-rising condition with nitrogen as a carrier gas and split-less mode. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.9998, analysed from 0.1 to 2.0 mg/L concentration. Limit of quantitation in agricultural commodities represents 0.05 mg/kg, and average recoveries ranged from 78.8 to 102.2%. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 9.5% in 0.05, 0.10, and 0.50 mg/kg. CONCLUSION(S): Our newly improved analytical method for DCPP residues in agricultural commodities was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.