Reduction of Entrance Surface Dose Depending on Shielding Methods for Panoramagraphy (파노라마 X선 검사시 차폐방법에 따른 Entrance Surface Dose 저감)

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.199-203
    • /
    • 2015
  • Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase. This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs.

Development of LabVIEW Program for Lock-In Infrared Thermography (위상잠금 열화상장치 제어용 랩뷰 프로그램 개발)

  • Min, Tae-Hoon;Na, Hyung-Chul;Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • A LabVIEW program has been developed together with simple infrared thermography(IRT) system to control the lock-in conditions of the system efficiently. The IR imaging software was designed to operate both of infrared camera and halogen lamp by synchronizing them with periodic sine signal based on thyristor(SCR) circuits. LabVIEW software was programmed to provide users with screen-menu functions by which it can change the period and energy of heat source, operate the camera to acquire image, and monitor the state of the system on the computer screen. In experiment, lock-in IR image for a specimen with artificial hole defects was obtained by the developed IRT system and compared with optical image.

The Feasibility Study on the Direct Use of the MC-derived Physical Quantities to Determine the Model Parameters of RTPS with -Model-Based Photon Dose Calculation Algorithm (모델기반 광자선량 계산방식을 사용하는 전산화치료계획장치의 모델변수 결정에 있어 몬테카를로 모사법에 의해 유도된 방사선 물리량의 직접 적용 가능성에 대한 연구)

  • 강세권;박희철;배훈식;조병철
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2004
  • The commissioning of a model-based treatment planning system requires many parameters to fit the measured depth doses and transverse profiles. For the commissioning of the Pinnacle$^3$ system, through the Monte Carlo (MC) simulation, the necessary parameters, including the photon spectrum, contaminant electrons, off-axis softening and fluency of photons, were observed. Through the simulation the parameters contained valuable information, but the calculated results of the Pinnacle$^3$ using the MC-derived parameters showed discrepancies with those measured for the off-axis softening and the fluency of photons. Even though the MC calculation produces reasonable values for the commissioning, the thorough physical basis of the Pinnacle$^3$'s commissioning process is needed in order to directly use the MC derived parameters.

  • PDF

A Status Report on Dual Energy X-ray Absorptiometry Quality Control in Korea (이중에너지 방사선흡수 골밀도 장치의 품질관리 현황)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Sung-Su;Kim, Kyoung-Ah;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.527-534
    • /
    • 2016
  • Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

Improvement of Production Process based on Performance Evaluation System of Unified Heater (통합히터 성능평가장치를 통한 생산 공정 개선)

  • Han, Woo-Hyun;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.114-118
    • /
    • 2014
  • This paper presents improvement of the production process of a unified fuel heater with the help of the performance evaluation system. In order to enhance a starting capability of diesel-engine car, the unified fuel heater is proposed, which consists of main body, upper plate, stopper, lower plate, PTC, screw, bimetal and terminals. In the proposed heater, the sensor is combined with heater body not only to maximize the performance of car but also to reduce the production cost. The performance test chamber is proposed to evaluate the performance of heater. Especially, an effective manufacturing progress for assembling the heater elements can cut down expenses.

최근의 초음파에 의한 비파괴 시험

  • 전춘생
    • 전기의세계
    • /
    • v.28 no.1
    • /
    • pp.5-14
    • /
    • 1979
  • 비파괴검사방법에는 여러가지가 있는데 과거에는 주로 방사건 유도시험이 주역을 이루어 왔다고 볼수 있다. 그런데 최근에는 초음파를 이용한 탐상장치의 성능이 향상하였고 초음파를 이용하지 않으면 검사할수 없는 대상물의 검사가 필요하게 되었다는 점에 의하여 초음파의 이용이 상당히 급속하게 확대되어 그 응용범위도 수도관에서 원자연료까지 이루게 되었다. 그러나 방사선 투과식 시험에서는 검출곤란한 균열을 검출할 수 있는 기술적 특성및 고가인 소모품이 필요치 않고 또한 검사속도도 빠르다는 경제성에 주목하여 방사투과시험이 가능한 대상물에 대해서도 이용하게끔 되었다. 초음파에 의한 비파괴시험을 이용목적에 따라 분류하면 탐상과 계측으로 대별할 수 있다. 이하 이들의 각종방법에 대하여 순차적으로 그 개요를 설명하겠다.

  • PDF

Development of Automatic Inspection System for Lead Screw of Computer (컴퓨터용 Lead Screw의 자동검사 시스템 개발)

  • Bae, Jin-Ho;Ra, Seung-Woo;Yu, Pill-Sang;Kim, Sung-Gaun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4115-4120
    • /
    • 2010
  • In manual inspection of Lead Screw of computers many workers are needed to inspect samples, and its main disadvantage is that such types of inspection system not only gives low production, but also gives low perfection. Besides, in manual inspection system, the inspection cost of samples is higher than that of the automatic inspection system. Therefore, in this study to compensate these shortcomings, an automatic inspection system is developed. For the inspection of the surfaces and different dimensional parameters of computer Lead screw, a $360^{\circ}$ rotating machine vision system is developed. From the detailed analysis of the inspection results using the present developed inspection system, it is observed that the developed Lead Screw automatic inspection system is superior to those of manually inspection system.

Assessment of Multiple Delamination in Laminated Composites for Aircrafts using X-ray Backscattering (X-ray 후방산란 기술을 이용한 항공기용 복합재료의 다중 층간 박리 평가)

  • Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • A Compton X-ray backscatter technique has been developed to quantitatively assess impact damage in quasi-isotropic laminated composites made by a drop-weight tester. X-ray backscatter imaging system with a slit-type camera is constructed to obtain a cross-sectional profile of impact-damaged laminated composites from the electron-density variation of the cross section. A nonlinear scattering model based on Boltsman equation is introduced to compute Compton X-ray backscattering field for the defect assessment. An adaptive filter is also used to reduce noises from many sources including quantum noise and irregular distributions of fibers and matrix in composites. Delaminations masked or distorted by the first delamination are detected and characterized effectively by the Compton X-ray backscatter technique, both in width and location, by application of error minimization algorithm.

Design of the Mechanical System for the Cylindrical Workpiece Inspection System (원통형 공작물 검사장치의 기계장치 설계)

  • Whang, Hyun-Seok;Kim, Gab-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.2
    • /
    • pp.22-28
    • /
    • 2019
  • In this study, we describe the mechanical design of the cylindrical workpiece inspection system which that can inspect the workpiece machined in the CNC lathe. The workpiece automatic measuring device is composed of a workpiece aligning mechanism, a workpiece diameter measuring mechanism, and a workpiece height measuring mechanism. If the workpiece machined on the CNC lathe is placed on the pedestal of the cylindrical workpiece inspection system, the workpiece aligning mechanism moves the workpiece to the diameter-measuring position and the height- measuring positions, and the diameter-measuring mechanism and the height- measuring mechanisms sequentially measure the diameter and the height of the workpiece. The cylindrical workpiece inspection system was designed and manufactured. The characteristic experiment was conducted to confirm the operation of the machine tool of the cylindrical workpiece inspection system. As a The result of the characteristic test shows that, the workpiece automatic measuring device operated safely.