• Title/Summary/Keyword: 검사 장치

Search Result 1,049, Processing Time 0.026 seconds

Cephalometric differences in obstructive sleep apnea between obese and non-obese Korean male patients (한국인 성인 남성 폐쇄성수면무호흡 환자의 측모 두부 방사선계측학적 비교)

  • Hwang, Sang-Hee;Park, In-Suk;Nam, Ki-Young;Kim, Jong-Bae;Cho, Yong-Won;Suh, Young-Sung;Ahn, Byung-Hoon;Park, Shin-Goo;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.202-213
    • /
    • 2008
  • Objective: The purpose of this study was to compare the cephalometric measurements of obese and non-obese Korean male patients with obstructive sleep apnea syndrome (OSA). Methods: Eighty-seven adults who had visited the Sleep Disorder Clinic Center in Keimyung University, Daegu, Korea were examined and evaluated with polysomnography (PSG) and lateral cephalogram. They were divided into 4 groups (non-obese simple snorers, obese simple snorers, non-obese OSA patients, obese OSA patients) according to AHI (Apnea-Hypopnea Index) and BMI (Body Mass Index). Results: The obese OSA group had the highest AHI among the 4 groups. The non-obese OSA group had a significantly steeper mandibular angle and shorter tongue length than the obese OSA group. The hyoid bone of the obese OSA group was positioned anterior and inferior as compared with the non-obese OSA group. Multiple regression analysis showed that tongue length in the obese OSA group and retroposition of hyoid bone in the non-obese OSA group were significant determinants for the severity of AHI. Conclusions: From a cephalometric point of view, the obese and non-obese pateints with OSA may be characterized by different pathogeneses. Therefore, they have to be managed by individualized treatment. For the obese OSA patients, weight control must be advised as a first choice and for the non-obese OSA patients, oral appliance, nasal CPAP, UPPP and others could be chosen according to the obstructive sites.

THE SPACE OF CONGENITALLY MISSING OF PRIMARY CANINE WITH ODONTOMA (치아종을 동반한 선천적 결손된 유견치의 공간)

  • Lee, Jung-Eun;Lee, Jae-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Song, Je-Seon;Son, Heung-Kyu;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.233-239
    • /
    • 2010
  • Space loss of dental arch can appear when the proper position of teeth within the dental arch changes by a certain cause, because the balance of force makes changes about tooth position as well as alignment. The causes of space loss include proximal caries, early extraction, congenital missing of a tooth and hypodontia, etc. Among those causes of space loss, congenital missing of a tooth is more rarely observed in the primary dentition than in the permanent dentition. Congenital missing in the primary dentition is associated with that in the permanent dentition. Furthermore, it can cause space problem, such as mesial tilting or drift of adjacent teeth, space loss for permanent successors and dental arch constriction, etc. Primary lateral incisors is the most commonly involved, in the maxilla rather than in the mandible, but primary canine is rarely reported. In this patient, who visited the department of pediatric dentistry at Yonsei university dental hospital, it was observed that the maxillary right primary canine was congenitally missing and an odontoma was found insteadly. However, neither the space loss for the congenitally missing primary canine nor midline deviation is remarkable during the 2-year-10-month observation period. In addition, any clinical or radiographical symptom did not occur in spite of odontoma. Therefore, surgical enucleation of odontoma is planned according to the eruption of permanent lateral incisor or canine, unless eruption failure of permanent lateral incisor or canine nor cystic change around the odontoma is occurred. Through further evaluation, space maintainer or orthodontic treatment may be necessary.

Treatment of Osteoid Osteoma (유골 골종의 치료)

  • Han, Chung-Soo;Cho, Chang-Hyun;Cho, Young-Lin;Cho, Nam-Su;Lim, Chan-Teak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose : The purpose of the current study was to report the results of curettage and en bloc excision as well as to introduce how to excise the nidus percutaneously with Halo-mill. Material and Methods : Twenty patients(14 men and 6 women) were evaluated, who had operative treatments after diagnosed as osteoid osteoma from March 1990 to January 1998. These patients ranged in age from 7 to 42 years(average: 20.8 years). Locations were 9 femurs, 6 tibias, 2 vertebras, 1 ulna, 1 maxilla and 1 skull. Nine femoral lesions included 5 proximal metaphysis, 2 neck and 2 diaphysis, while 5 tibial lesions included 3 diaphysis, 1 proximal metaphysis and 1 distal metaphysis. We used simple radiography, bone scan, CT and MRI for the accurate diagnosis and localization. As for surgical treatments, while excision and curettage had to need open-exposure of lesion, the percutaneous excision of nidus did not need openexposure : guided Halo-mill into K-wire inserted to nidus under image intensifier. Results : Simple radiography showed that 10 cases had typical nidus and others had only cortical sclerosis. Bone scan was performed at 14 cases and all had hot uptake except one case. We used CT in 10 cases and MRI in 4 cases as diagnostic methods, of which 1 case didn't reveal nidus at CT. Surgical treatment consisted of 6 curettages, 11 excisions, 2 percutaneous excisions with halo-mill and 1 total elbow arthroplasty. We used 7mm sized Halo-mill. During the follow-up period, all patient relieved symptoms and there were no recurrences. All had histologically typical findings except one which had hyperostosis without nidus. Conclusion : Complete removal of the nidus is the most important factor in the treatment. We could excise the nidus percutaneously in 2 cases with the minimal injury to surrounding soft tissues. If we could evaluate the precise location, size of nidus and percutaneous acccesibility, the percutaneous excision of nidus with Halo-mill could be an alternative method as a treatment of osteoid osteoma.

  • PDF

Comparison of Agar-gel Diffusion Test, Counterimmunoelectrophoresis and Enzyme-Linked Immunosorbent Assay in the sera of skin teat positives for paragonimiasis (간흡충 피내반응 양성자에 대한 Agar-gel Diffusion, Counterimmunoelectrophoresis 및 Enzyme-Linked Immunosorbent Assay의 비교)

  • 이옥란;최원영
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.270-280
    • /
    • 1983
  • Agar-gel Diffusion test (AGD), Counterimmunoelectrophoresis(CIEP) and Enzyme-Linked Immunosorbent Assay(ELISA) were examined with the sera of skin test positives for paragonimiasis. The crude antigen (Paragcnimus whole worm extracts: protein concentration, 7.56mg/m1) and human sera were used in AGD and CIEP. And in ELISA test, diluted antigen with 1:40, 000 of crude antigen and diluted sera with 1:100, 1:200 were used in the test. The positive identical ratio between AGD and CIEP reactions is 985 and negative identical ratio is 100%. One or three precipitin bands are observed in AGD. One to seven precipitin bands are also revealed in CIEP. Especially, deeply stained bands are observed in CIEP than those of AGD. The positive identical ratios between AGD and ELISA tests are 96% in 1:100 diluted sera, and 94% in 1:200 diluted sera. But the negative identical ratios between AGD and ELISA tests are 97% and 99% respectively in 1:100 and 1:200 diluted sera. The positive identical ratios between CIEP and ELIEA tests are 98% and 96% respectively in 1:100 and 1:200 diluted sera, but also 97% and 99% in 1:100 and 1:200. Control sera, such as clonorchiasis, amoebiasis and toxoplasmcsis, revealed all negatives with Paragonimus antigen in AGD, CIEP and ELISA tests. By above results, ELISA was mcst sensitive, next CIEP and AGD, But AGD test apprars to be more useful when used to crude antigen without cross rfacticn with other parasitic infections. CIEP test is basically equal in terms of precipitin reaction, but CIEP is able to be detected more sensitively and rapidly though less simple in handiwork than AGD. Consequently, three methods for inlmunological tests of paragonimiasis have gccd correlations with one another. Also, each of these has both merits and demerits in iymunolcgical test for paragonimiasis. But the ELISA test was proved to be the most sensitive and convenient tool for mass screening test, especially in cacti of using purified antigen.

  • PDF

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

Changes of Ventricular Function and Mitral Regurgitation after Repair of Anomalous Origin of Coronary Artery from the Pulmonary Artery (관상동맥 폐동맥 이상 기시증의 외과적 치료 후 좌심실 및 승모판 기능의 변화)

  • Lee Jeong Ryul;Oh Sea Jin;Kim Woong Han;Kim Yong Jin;Rho Joon Ryang;Bae Eun Jung;Noh Chung II;Yun Yong Soo
    • Journal of Chest Surgery
    • /
    • v.38 no.8 s.253
    • /
    • pp.523-528
    • /
    • 2005
  • Background: Investigation of the change of ventricular function and mitral regurgitation after surgical repair of patient with anomalous origin of left coronary artery from the pulmonary artery (ALCAPA) is key issue for the better surgical outcome. Material and Method: From April 1986 to July 2002, 12 patients presented with ALCAPA. The median age at repair was 4 months. Surgical methods included left coronary artery transfer to the aorta (10), Takeuchi procedure (1), saphenous vein free graft bypass (1). Mitral valve was repaired in 1. Result: There were 2 hospital death $(16.7\%)$. The mean follow-up period was $7.1\pm4.1$ years (range, 7 months to 13 years). Four patients required postoperative circulatory assist for $2.2\pm1.1$ days and one needed left ventricular assist device (LVAD) for 1day. Postoperative echocardiography demonstrated significant improvements in mean fractional shortening $(33.4\pm9.1\%\;vs\;17.7\pm9.6\%,\;n=10,\;p<0.05);$ left ventricular end diastolic dimension $(33.4\pm7.3\;mm\;vs\;44.8\pm7.0\;mm,\;n=10,\;p<0.05)$ and systolic dimension $(22.2\pm7.5\;mm\;vs\;33.4\pm7.9\;mm,\;n=10,\;p<0.05)$. Severities of mitral regurgitation decreased in all survivors at 1st and 4th year follow-up echocardiography. There were 2 reoperation due to residual MR and right ventricular outflow obstruction (Takeuchi case). Conclusion: Anatomic repair of anomalous left coronary artery from the pulmonary artery offered an excellent surgical results, especially in terms of the recovery of left ventricle function and mitral regurgitation. However, preoperative indications for mitral procedure is to be evaluated.

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF

The Design of Mobile Medical Image Communication System based on CDMA 1X-EVDO for Emergency Care (CDMA2000 1X-EVDO망을 이용한 이동형 응급 의료영상 전송시스템의 설계)

  • Kang, Won-Suk;Yong, Kun-Ho;Jang, Bong-Mun;Namkoong, Wook;Jung, Hai-Jo;Yoo, Sun-Kook;Kim, Hee-Joung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.53-55
    • /
    • 2004
  • In emergency cases, such as the severe trauma involving the fracture of skull, spine, or cervical bone, from auto accident or a fall, and/or pneumothorax which can not be diagnosed exactly by the eye examination, it is necessary the radiological examination during transferring to the hospital for emergency care. The aim of this study was to design and evaluate the prototype of mobile medical image communication system based on CDMA 1X EVDO. The system consists of a laptop computer used as a transmit DICOM client, linked with cellular phone which support to the CDMA 1X EVDO communication service, and a receiving DICOM server installed in the hospital. The DR images were stored with DICOM format in the storage of transmit client. Those images were compressed into JPEG2000 format and transmitted from transmit client to the receiving server. All of those images were progressively transmitted to the receiving server and displayed on the server monitor. To evaluate the image quality, PSNR of compressed image was measured. Also, several field tests had been performed using commercial CDMA2000 1X-EVDO reverse link with the TCP/IP data segments. The test had been taken under several velocity of vehicle in seoul areas.

  • PDF

Comparison of Cleaning Performance of CFC 113 and the Alternatives (CFC 113과 대체세정제의 세정성능 비교)

  • Row, Kyung Ho;Choi, Dai-Ki;Lee, Youn Yong
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.521-530
    • /
    • 1993
  • According to the Montreal Protocol, CFC 113, one of the ozone-depleting substances, will be prohibited to use as a cleaning solvent essentially in the electronic industry. Therefore, the development of the alternative cleaning solvents to CFC 113 is being accelerated. A number of the alternative cleaning solvents are avialable on the market. The alternatives of Axarel 32(DuPont), Cleanthru 750H(KAO Chemical), and EC-Ultra(Petroferm) are chosen for the comparison of cleaning performance with CFC 113. The test methods for measuring the cleaning performance were composed of the measurement of the physical properties, the experiments on the material compatibility with cleaning solvents, the measurement of the evaporation rate, and finally the experiments of the removal efficiency. Normally the basic physical properties of the alternatives had higher boiling points, viscosity and surface tension, which were quite different to those of CFC 113. In terms of solubility of rosin-based flux, the solubilities of abietic acid (nonpolar organic) were similar, but those of the activator (polar organic) in the alternatives were better than CFC 113. The evaporation of the alternatives was very slow, compared to CFC 113, which had much lower boiling point. All the cleaning solvents showed the good material compatibility with FR4 and Cu-coated PCB. The better removal efficiencies of abietic acid were obtained when using the ultrasonic mechanical energy over the dipping method. The experiments also indicated the very slow-eavaporating solvent was not desirable with the dipping cleaning method, and the differences in the removal efficiency of the alternatives with the ultrasonic cleaning method were negligible. Among the alternatives, the overall cleaning performances were obsorved as almost similar. Before selecting the ultimate cleaning solvent, the application of cleaning machine, environmental issues, and economics are simultaneously considered with the cleaning performance.

  • PDF

Changes in KVA Resulting from Correction Condition of Refractive Error (굴절이상 교정상태에 따른 동적시력 변화)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kang, Hye-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • Purpose: This study are to analyze and to compare between pupillary size, reaction time, refractive error, corrected vision, dominant eye, static visual angle (SVA) and kinetic visual acuity (KVA) of male and female college students, to measure KVA of them in full correction and to identify changes of KVA by +0.50 D and -0.50 D spherical power addition respectively in full correction condition. Methods: KVA, SVA, pupillary size, reaction time, refractive error, corrected vision and dominant eye of 40 male and 40 female optical science students were measured by utilizing KOWA AS-4A, reaction time measurement program, subjective refractometer, and objective refractometer, and KVAs were measured when +0.50 D/-0.50 D were added in both eyes respectively. Results: Binocular KVA of whole subjects was $0.45{\pm}0.22$, and in monocular KVAs were $0.36{\pm}0.19$ for right eye and $0.34{\pm}0.19$ for left eye, and binocular KVA was significantly higher than monocular KVA. It appeared that the better SVA was, the better KVA was in significant way, and in terms of refractive error the less myopia amount was, the better KVA was, but it was not significant statistically. The lower astigmatism was, the slightly and significantly higher KVA was when dividing between equal or less than -1.00 D astigmatism group and over -1.00 D astigmatism group. In resulting from correction condition of refractive error KVAs were $0.45{\pm}0.22$ for full correction, $0.26{\pm}0.15$ for +0.50 D addition, $0.48{\pm}0.22$ for -0.50 D addition which indicates that KVA in over myopia correction was significantly the highest and followed by full correction and under correction. Similar findings were revealed in both male and female, and KVA of male was better than female in comparing between male and female. There was no significantly different KVA between dominant eye and non-dominant eye. Conclusions: Accordingly, it is concluded that KVA is related with far distance SVA, astigmatism amount, and refractive error amount except a dominant eye. Through this research, it was found that prescription for enhancing KVA is to make full correction or to overcorrect slightly myopia.