A 9-month-old, intact female Maltese dog and one-year-old, intact female beagle dog were presented with continuous heart murmur. These 2 dogs were diagnosed as patent ductus arteriosus (PDA) based on the two-dimensional echocardiography and angiography. Due to the large shunt size, commercially available ductal occlude device was used for transcatheter occlusion of PDA. After Amplatzer$^{(R)}$ vascular plug placement, cardiac murmur was abruptly disappeared in Maltese dog and mildly decreased in beagle dog. Complications and safety after the procedure were evaluated regularly in these 2 dogs. This is first clinical application of Amplatzer$^{(R)}$ vascular plug for transcatheter closure of PDA in two dogs in Korea.
Park, Tae-Jin;Lee, Un-Seon;Lee, Sang-Hee;Park, Man-Gon
Journal of Korea Multimedia Society
/
v.14
no.7
/
pp.895-904
/
2011
In welding machine that executes existing spot welding, wrong operation of system has often occurs because of their mechanical motion that can be caused by a number of supply like the welding object. In exposed working environment for various situations such as worker or related equipment moving into any place that we are unable to exactly distinguish between good and not condition of nut. Also, in case of defective welding of nut, it needs various evaluation and analysis through image processing because the problem that worker should be inspected every single manually. Therefore in this paper, if the object was not stabilization state correctly, we have purpose to algorithm implementation that it is to reduce the analysis time and exact recognition as to improve system of image processing. As this like, as image analysis for assessment whether it is good or not condition of nut, in his paper, implemented algorithms were suggested and list by group and that it showed the effectiveness through more than one experiment. As the result, recognition rate of normality and error according to the estimation time have been shown as 40%~94.6% and 60%~5.4% from classification 1 of group 1 to classification 11 of group 5, and that estimation time of minimum, maximum, and average have been shown as 1.7sec.~0.08sec., 3.6sec.~1.2sec., and 2.5sec.~0.1sec.
Proceedings of the Korean Society of Medical Physics Conference
/
2004.11a
/
pp.96-99
/
2004
The objective of this study is to assess attenuation correction algorithms utilized in a multipurpose whole-body GSO PET scanner. Four different types of phantoms were tested using different types of attenuation correction techniques. FOV (Field of View) of 256mm was used for brain PET imaging. For compensating attenuation, transmission data of a $^{137}$Cs point source were acquired after the F-18 emission source was infused to the phantoms. Scatter correction were peformed. Reconstructed images of the phantoms were assessed. In addition, reconstructed images of a normal subject were compared and assessed by nuclear medicine physicians. As a result, decreased intensity at the central portion of the attenuation map with cylindrical phantom was noticed during use of the measured attenuation correction. On the other hand, segmentation or remapping attenuation correction provided uniform phantom image. the images reconstructed from the clinical brain data explained the attenuation of a skull, at though reconstructed images of the phantoms couldn't explain it. in conclusion, the complicated and improved attenuation correction methods were required to obtain the better accuracy of the quantitative brain PET images. Our study will be useful in improving quantitative brain PET imaging modalities with attenuation correction of $^{137}$Cs transmission source.
Catecholamines, serotonin and their metabolites were measured in the posterior hypothalamus of urethane-anesthetized normotensive Wistar Kyoto rats (WKY) and spontaneously hypertensive rats (SHR) using brain microdialysis which is a recently developed experimental method to measure the release of neurotransmitters and their metabolites at the localized brain area in vivo. Microdialysis probe was implanted stereotaxically to the rat posterior hypothalamus and perfused by Ringer's solution. Monoamines and their metabolites were quantified by reverse phase high performance liquid chromatography with electrochemical detection. In vitro recovery test of microdialysis showed that there exist inverse relationship between the perfusion flow rate and the relative recovery of neurochemical compounds. The estimated extracellular concentration of dopamine was about 32 nM, of norepinephrine 50 nM, of epinephrine 50 nM, of serotonin 73 nM, of 3, 4-dihydroxyphenylacetic acid (DOPAC) 281 nM, of homovanillic acid (HVA) 181 nM, and of 5-hydroxyindoleacetic acid (5HIAA) 3767 nM in the hypothalamic perfusate of the normotensive rat. There was no difference in the basal level of monoamines between the SHR and the WKY. In contrast, the level of DOPAC, HVA and 5HIAA in SHR was higher than that in the WKY, This study demonstrated that the microdialysis technique should be an applicable tool for in vivo measurement of central neurochemical substances.
Purpose: This study investigated differences in stereoscopic fusional area between those with good and poor stereo acuity in viewing stereoscopic displays. Methods: Stereo acuity of 39 participants (18 males and 21 females, $23.6{\pm}3.15years$) was measured with the random dot stereo butterfly method. Participants with stereo-blindness were not included. Stereoscopic fusional area was measured using stereoscopic stimulus by varying the amount of horizontal disparity in a stereoscopic 3D TV. Participants were divided into two groups of good and poor stereo acuity. Criterion for good stereo acuity was determined as less than 60 arc seconds. Measurements arising from the participants were statistically analyzed. Results: 26 participants were measured to have good stereo acuity and 13 participants poor stereo acuity. In case of the stereoscopic stimulus farther than the fixation point, threshold of horizontal disparity for those with poor stereo acuity were measured to be smaller than the threshold for those with good stereo acuity, with a statistically significant difference. On the other hand, there was no statistically significant difference between the two groups, in case of the stereoscopic stimulus nearer to the fixation point. Conclusions: In viewing stereoscopic displays, the boundary of stereoscopic fusional area for the poor stereo acuity group was smaller than the boundary of good stereo acuity group only for the range behind the display. Hence, in viewing stereoscopic displays, participants with poor stereo acuity would have more difficulty perceiving the fused image at farther distances compared to participants with good stereo acuity.
1) 본 연구에서 시료로 선정한 충남 서산산 건강(dry ginger)은 수분이 $9.4\%$, 회분이 $8.7\%$ 그리고 alcohol에 의한 추출량이 약 $9\%$이다. 이는 선진국에 채택사용하고 있는 건강의 규격기준에 의하면 양호하다. 2) Non- flavor물질의 추출을 최소화하고 특히 증류과정에서 유효성분 손실을 최소화 할 수 있고, 엑기스내의 용매 잔류량이 인체에 유해하지 않고 추출효율을 높일 수 있는 용매는 ethyl alcohol이다. 3) 널리 사용하고 있는 관류추출(percolation)의 성능을 분석하고 이의 개선방안을제시하였다. - 추출효율을 높이기 위하여 건강(dry ginger)의 입자를 작게하면 압력강하가 증대되어순환되는 용액의 유속을 제어하기가 힘들다. - 입자가 작을 시에는 유체의 흐름이chan-nelling현상을 나타낸다. - 위와 같은 조건에서는 물질 전달속도가 느리므로 추출효율을 증대시킬 수가 없다. - 따라서 percolation추출에 사용되는 건강의 입자크기는 30mesh크기 이상이어야 운전조작이 용이하나 추출효율이 낮으므로, 추출시간 6시간에 회수된 생강엑기스양은 약 $2.5\%$이다. 4) percolation추출의 단점을 보완하기 위하여 기계적교반 추출을 선택하여 다음과 같은 개선점을 찾았다. - 교반형 추출에서는 고 - 액분리시 cake 저항에서 문제가 야기되지 않는 범위까지 건강의 입자를 작게할 수 있으므로 추출효율을 크게 향상시킬 수 있었다. 즉, 작게 분쇄된 건강(30mesh통과$90\%$)을 대상으로 추출시간 3시간에 $7\%$의 회수율로 증대시켰다. 최적 운전조건은 다음과 같다. 건강시료:1kg 시료크기:-30mesh$90\%$ 용매:ethyl alcohol 3$\iota$ 교반속도:900r.p.m 추출온도:상온($15\~25^{\circ}C$) 추출시간:3시간 일차 추출조건과 동일하게 하여 얻어진 엑기스의 수율이 $2\~2.5\%$이므로 총엑기스의 수율은 건강(dry ginger)무게기준으로 $8.5\~9.5\%$이었다. 5) 교반추출의 효율이 개선되었다 하더라도 추출물의 분리가 용이하여야만 공정의 이용이 가능하다. 그러므로 교반추출후 고 - 액분리를 위하여 정압여과 장치를 이용하여 여과시 cake의 평균 비저항을 얻었으며, 이의 값은 $4.31\times10^8cm\;/\;gr$으로서 여과에는 어려움이 없다는 것을 의미한다. 따라서 추출속도와 효율이 상대적으로 우수한 교반형 추출기의 가능성을 예시할 수 있음을 알 수 있었다. 6) 추출물을 농축과정에서 휘발성 oil의 손실을 최대로 줄이기 위해서는 단순증류를 하지 말고 분별증류를 수행하여야 하며, gingerol과 같은 중요성분의 열분해 반응을 억제하기 위해서는 열전달 효율을 증대시켜 증류조작을 원활히 수행하여야 하므로, still내의 농축물을 계속 교반시켜야 하며 감압상태에서 증류온도는 $40\~50^{\circ}C$로 유지시키는 것이 가장 바람직하다. 7) Ethyl alcohol로 추출된 엑기스내의 수분이나 회분함량은 외국산 제품에 비하여 약간 낮고, 반면에 조지방 및 조단백 성분의 함량은 약간 높게 나타나고 있어 대체적으로 본 연구에서 얻어진 엑기스내의 비풍미성분(non- fla-vour component) 함량은 외국산에 비하여 많은 차이가 없다. 8) 수입 외국산에 비하여 국산엑기스(본 연구에서 ethyl alcohol로 추출)내의 무기성분등의 함량은 비교적 낮은 편이다. 9) 건강에서부터 oleoresin을 얻어 paradol을 제거시킨 후 순수한 gingerol을 분리하여 IR과 NMR로 확인한 결과, 국산건강의 엑기스에는 주로 6-gingerol이고 약간의 10-gingerol이 함유된 것으로 나타났다. 10) 순수하게 분리된 gingerol을 열분석(TGA와 DTG)한 결과 약 $75^{\circ}C$에서 gingerol의 열분해 반응이 일어남을 알수 있었다. 11) 건강 분말시료와 엑기스내의 미생물 검사 결과 건강분말에서는 세균수가 많이 존재하는 것으로 나타났으나, 이는 ethyl alcohol로 추출하는 공정 중 대부분의 균들이 사멸된 것으로 나타났다. 12) 관능적 측면에선, 본 연구에서 제조한 엑기스와 수입엑기스를 비교한 결과 생강 특유의 맛은 비슷했으나, 수입엑기스에서는 쓴맛과 톱밥냄새를 느낀다는 결과를 나타내었으며 전체적인 종합적 풍미는 국산 건강엑기스가 좋은 것으로 나타났다.
Volatile flavor components in powdered Katsuobushi were simultaneous trapped by steam distillation-extraction method, and these were fractionated into the neutral, the phenolic, the acidic and the basic fraction. Volatile flavor components in these fraction were analyzed by the high-resolution GC and GC-MS equipped with a fused silica capillary column. The whole steam volatile concentrate consisted of $48\%$ neutral fraction(NF), $35\%$ phenolic fraction(PF), $12\%$ acidic fraction(AF) and $5\%$ basic fraction(BF). Thirty components such as 8 hydrocarbons, 8 aldehydes, 6 furans, 5 alcohols and 3 ketones were identified from NF. And sixteen components such as phenol, guaiacol, dimethoxy phenol, eugenol in PF, twelve components such as propionic, butanoic, isopentanoic, n-hexanoic, heptanoic, octanoic acid in AF, ten components such as 2,6-dimethylpyrazine, 2-nethylpyridine, 2,4-dimethylthiaBole in BF were identified. NF and PF gave a much higher yield than others and were assumed to be indispensable for the reproduction of aroma of powdered Katsuobushi. It was also identified eight components of volatile carbonyl compounds such as ethanal, propanal, butanal, pentanal by 2,4-DNPH method.
Kim, Sung Hoon;Park, Young Min;Noh, Sang Wan;Park, Dae Hoon
Journal of the Korea Academia-Industrial cooperation Society
/
v.21
no.5
/
pp.443-450
/
2020
This paper reports a design improvement study to solve the stoppage phenomenon caused by the launch-support device applied to K105A1. The K105A1 is a weapon system equipped with an old 105 mm towed howitzer in a wheeled vehicle, which provides superior maneuverability compared to track equipment. The launch support device serves to withstand fire impact and load. In this way, this device is fixed firmly to the ground in preparation for the shooting mission and is responsible for the critical performance, such as fixing the position of the vehicle. On the other hand, during the field test, a temporary stoppage of the launch support occurred, which caused a problem of not being fixed to the ground. To solve this problem, the cause of failure was analyzed by a replay test and parts inspection. In addition, the operating concept, method, and design were analyzed to derive the cause and solve the problem by changing the parts design. Finally, the performance and firing missions were performed normally by applying the changed design to K105A1. The performance stability and reliability of the launch support device were confirmed, which are expected to be of great assistance in the development of military equipment in the future.
Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
The Journal of the Korea Contents Association
/
v.13
no.8
/
pp.284-291
/
2013
The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.
Son, Seong Ho;Park, Ha Ryung;Baek, Jung Jin;Son, Jong Ki;Choi, Min Ho
The Journal of Korean Society for Radiation Therapy
/
v.31
no.2
/
pp.7-12
/
2019
Purpose: During the pelvic radiation therapy, it is performed with controlling bladder volume because the range of irradiation is changed depending on the bladder volume. Therefore in this study, we evaluate the accuracy of BVI by tracing the change of bladder volume using ultrasonic pulse diagnosis equipment(BVI 6100, Medical supply Co. LTD) Material and Methods: From January 2017 to September 2018, 19 patients who received pelvic radiation therapy at Pusan National University Hospital were included. To treat the patient, we compared that the bladder volume obtained from the BVI and the bladder volume obtained from the CBCT image then we evaluated for significance. Results: There was a significant correlation of r=0.773, BVI and CBCT in the whole volume section. However, based on the bladder volume in the RTP Image the p value was shown to be 0 at 125~175cc and lower than 0.05 at 175~275cc, And more than 0.05 at 275~375cc. Conclusions: In this study, the patient whose bladder volume is above than 275cc, there is a significance of bladder volume between BVI and CBCT image. However, we could make a decision to be undermined the reliability of BVI measurement in the case of the patient with emptied his urine. Therefore, it is possible to acquire a significant value for 175~275cc patients to use the correction value of BVI and the appropriate tolerance of volume.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.