• Title/Summary/Keyword: 검사장치

Search Result 1,054, Processing Time 0.04 seconds

Bicycle Riding-State Recognition Using 3-Axis Accelerometer (3축 가속도센서를 이용한 자전거의 주행 상황 인식 기술 개발)

  • Choi, Jung-Hwan;Yang, Yoon-Seok;Ru, Mun-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.63-70
    • /
    • 2011
  • A bicycle is different from vehicles in the structure that a rider is fully exposed to the surrounding environment. Therefore, it needs to make use of prior information about local weather, air quality, trail road condition. Moreover, since it depends on human power for moving, it should acquire route property such as hill slope, winding, and road surface to improve its efficiency in everyday use. Recent mobile applications which are to be used during bicycle riding let us aware of the necessity of development of intelligent bicycles. This study aims to develop a riding state (up-hill, down-hill, accelerating, braking) recognition algorithm using a low-power wrist watch type embedded system which has 3-axis accelerometer and wireless communication capability. The developed algorithm was applied to 19 experimental riding data and showed more than 95% of correct recognition over 83.3% of the total dataset. The altitude and temperature sensor also in the embedded system mounted on the bicycle is being used to improve the accuracy of the algorithm. The developed riding state recognition algorithm is expected to be a platform technology for intelligent bicycle interface system.

A Comparison Between the Tape Switch Sensor and the Video Images Frame Analysis Method on the Speed Measurement of Vehicle (차량 속도 측정의 실무적용을 위한 테이프스위치 센서 방식과 영상 프레임 분석방법의 비교연구)

  • Kim Man-Bae;Hyun Cheol-Seung;Yoo Sung-Jun;Hong You-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.9 s.351
    • /
    • pp.120-127
    • /
    • 2006
  • In Korea the vehicle enforcement system(VES) detects speeding vehicle using two inductive loop detectors. And the speed reliability of theirs are evaluated through the analysis of image frame which is captured from video camera. This method is validated to evaluate VES on Korea Laboratory Accreditation Scheme(KOLAS) but it needs much time and expense for the analysis of image frame. Because the number of VES are increasing rapidly, the requirement of new evaluation method is necessary. On this paper, the tape switch sensor as a substitution of existing method was introduced and its application on the site are discussed. On the site test we compared the tape switch sensor on the speed measurement of vehicle with the video image frame. As a result we have founded that the tape switch sensor is evaluated to be feasible system on site in respect to measure the overspeed vehicle.

하이브리드 SEM 시스템

  • Kim, Yong-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.109-110
    • /
    • 2014
  • 주사전자현미경(Scanning Electron Microscopy: SEM)은 고체상태에서 미세조직과 형상을 관찰하는 데에 가장 다양하게 쓰이는 분석기기로서 최근에 판매되고 있는 고분해능 SEM은 수 나노미터의 분해능을 가지고 있다. 그리고 SEM의 초점심도가 크기 때문에 3차원적인 영상의 관찰이 용이해서 곡면 혹은 울퉁불퉁한 표면의 영상을 육안으로 관찰하는 것처럼 보여준다. 활용도도 매우 다양해서 금속파면, 광물과 화석, 반도체 소자와 회로망의 품질검사, 고분자 및 유기물, 생체시료 nnnnnnnnn와 유가공 제품 등 모든 산업영역에 걸쳐 있다(Fig. 1). 입사된 전자빔이 시료의 원자와 탄성, 비탄성 충돌을 할 때 2차 전자(secondary electron)외에 후방산란전자(back scattered electron), X선, 음극형광 등이 발생하게 되는 이것을 통하여 topography (시료의 표면 형상), morphology(시료의 구성입자의 형상), composition(시료의 구성원소), crystallography (시료의 원자배열상태)등의 정보를 얻을 수 있다. SEM은 2차 전자를 이용하여 시료의 표면형상을 측정하고 그 외에는 SEM을 플랫폼으로 하여 EDS (Energy Dispersive X-ray Spectroscopy), WDS (Wave Dispersive X-ray Spectroscope), EPMA (Electron Probe X-ray Micro Analyzer), FIB (Focus Ion Beam), EBIC (Electron Beam Induced Current), EBSD (Electron Backscatter Diffraction), PBMS (Particle Beam Mass Spectrometer) 등의 많은 분석장치들이 SEM에 부가적으로 장착되어 다양한 시료의 측정이 이루어진다. 이 중 결정구조, 조성분석을 쉽고 효과적으로 할 수 있게 하는 X선 분석장치인 EDS를 SEM에 일체화시킨 장비와 EDS 및 PBMS를 SEM에 장착하여 반도체 공정 중 발생하는 나노입자의 형상, 성분, 크기분포를 측정하는 PCDS(Particle Characteristic Diagnosis System)에 대해 소개하고자 한다. - EDS와 통합된 SEM 시스템 기본적으로 SEM과 EDS는 상호보완적인 기능을 통하여 매우 밀접하게 사용되고 있으나 제조사와 기술적 근간의 차이로 인해 전혀 다른 방식으로 운영되고 있다. 일반적으로 SEM과 EDS는 별개의 시스템으로 스캔회로와 이미지 프로세싱 회로가 개별적으로 구현되어 있지만 로렌츠힘에 의해 발생하는 전자빔의 왜곡을 보정을 위해 EDS 시스템은 SEM 시스템과 연동되어 운영될 수 밖에 없다. 따라서, 각각의 시스템에서는 필요하지만 전체 시스템에서 보면 중복된 기능을 가지는 전자회로들이 존재하게 되고 이로 인해 SEM과 EDS에서 보는 시료의 이미지의 차이로 인한 측정오차가 발생한다(Fig. 2). EDS와 통합된 SEM 시스템은 중복된 기능인 스캔을 담당하는 scanning generation circuit과 이미지 프로세싱을 담당하는 FPGA circuit 및 응용프로그램을 SEM의 회로와 프로그램을 사용하게 함으로 SEM과 EDS가 보는 시료의 이미지가 정확히 일치함으로 이미지 캘리브레이션이 필요없고 측정오차가 제거된 EDS 측정이 가능하다. - PCDS 공정 중 발생하는 입자는 반도체 생산 수율에 가장 큰 영향을 끼치는 원인으로 파악되고 있으며, 생산수율을 저하시키는 원인 중 70% 가량이 이와 관련된 것으로 알려져 있다. 현재 반도체 공정 중이나 반도체 공정 장비에서 발생하는 입자는 제어가 되고 있지 않은 실정이며 대부분의 반도체 공정은 저압환경에서 이루어지기에 이 때 발생하는 입자를 제어하기 위해서는 저압환경에서 측정할 수 있는 측정시스템이 필요하다. 최근 국내에서는 CVD (Chemical Vapor Deposition) 시스템 내 파이프내벽에서의 오염입자 침착은 심각한 문제점으로 인식되고 있다(Fig. 3). PCDS (Particle Characteristic Diagnosis System)는 오염입자의 형상을 측정할 수 있는 SEM, 오염입자의 성분을 측정할 수 있는 EDS, 저압환경에서 기체에 포함된 입자를 빔 형태로 집속, 가속, 포화상태에 이르게 대전시켜 오염입자의 크기분포를 측정할 수 있는 PBMS가 일체화 되어 반도체 공정 중 발생하는 나노입자 대해 실시간으로 대처와 조치가 가능하게 한다.

  • PDF

A Study on Improving Installation Guideline of Facilities to Protect Groundwater Contamination: Applications of Packer Grouting to Contaminated Wells (지하수오염방지 시설기준의 개선에 관한 연구:지하수오염관정에의 팩커그라우팅 적용사례)

  • Choo, Chang-Oh;Ryu, Jong-Heum;Cho, Heuy Nam;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.293-304
    • /
    • 2013
  • Because the present groundwater law broadly regulates a simple and impractical guideline ignoring aquifer characters and geology, general purpose facilities for protection of groundwater contamination is still considered unsatisfactory to ensure groundwater resources. In recent, there have been growing attempts in the packer development as crucial techniques and devices for groundwater protection. This study investigated the application of packer grouting techniques to contaminated groundwaters of two well sites in the Andong and Yeongi areas, both of which revealed a satisfactory effect with improved water quality: 94% decrease in turbidity at the Andong area and 60% decrease in $NO_3$-N, respectively. Based on aquifer characters including geology, weathering depth, fracture pattern, hydraulic gradient, and the flow path of contaminants, the integrated properties of groundwater contamination should be evaluated and treated with the help of accurate analyses such as bore hole imaging and monitoring data. Packer grouting and casing on well to ensure the useful aquifer free of contaminant are expected to play important role in inhibiting the inflow of contaminants when adequately applied. Therefore it is concluded that these can serve as reliable tools in remediation and protection of contaminated groundwater as well as efficient utilization of groundwater.

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

Biocompatibility Evaluation of Bent-Type Left Ventricular Assist Device During Long-Term Animal Experiment and Emergent Situation (장기 동물 실험 및 응급상황에서의 곡관형 좌심실보조장치의 생체적합성 평가)

  • Kang, Seong Min;Her, Keun;Choi, Seong Wok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.739-745
    • /
    • 2014
  • Although medication is given to heart disease patients, conventional medication alone is not sufficient to treat heart disease. However, it has been reported that left ventricular assist device (LVAD) transplantation is an effective bridge to heart transplantation by assisting cardiac function. This study used long-term animal testing and emergency situations with a bovine model (Holstein) and canine model (Labrador-retriever) to evaluate the biocompatibility of LibraHeart-I (LH-1), which is a bent-tube type of LVAD that was developed in a previous study. In the long-term animal testing with the bovine model, the subjects survived for 49 days with no irregularities observed in their complete blood cell counts or the vital sign tests that were carried out during the test period. In short-term animal testing with the canine model, it was observed that blood did not remain inside the LH-I even without power support from an external drive source. In this study, the biocompatibility of the LH-I that was developed in a previous study was verified by the ejection performance during long-term animal testing and emergency situations.

Gynecologic Patients' Recognition of Radiation Exposure in Gyeongbuk Area (경북 지역 산부인과 환자의 방사선피폭 인식)

  • Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.8
    • /
    • pp.176-187
    • /
    • 2008
  • As the radiological medical instruments have been competitively developed in recent years, its utilization for the patient treatment has been expanded. The medical examination using the radiation has been gradually increased, so that it is recognized as a significant factor of increasing the radiation exposure. In this study, the recognition about the radiation exposure was analyzed for 555 gynecologic patients in 8 secondary and tertiary medical centers in Gyeongbuk from November 17 to April 19, 2007. The results are followed. There was a significant difference on the recognition for the radiation by age and education (p<0.05), There was the significant difference in the recognition about the radiological instruments by age and occupation (p<0.05), and there was the significant difference in the information identification & analysis by age and occupation (p<0.05). As the result of analyzing a correlation of the radiation's harmfulness, recognition, psychological state and exposure prevention, there was the correlation of 0.572 between the harmfulness and recognition, the correlation of 0.740 between the harmfulness and the psychological state, and the correlation of 0.477 between the harmfulness and the exposure prevention. It was statistically very significant (p<0.01). But, there was no significance with the radiological instrument and information identification (p>0.05). As the result of the study, it could be known that the mental threat factor was more included than the physical threat from the position of gynecologic patients who were sensitive to the radiation. Accordingly, radiological technologist who manages the radiation needs to let the patient or its guardians recognize the degree of physical harmfulness exactly.

ERUPTION DISTURBANCE OF THE LOWER LEFT FIRST PERMANENT MOLAR CAUSED BY AMELOBLASTIC FIBROMA (법랑모세포섬유종에 의한 하악 제1대구치의 맹출 장애)

  • Kim, Seung-Hye;Song, Je-Seon;Son, Heung-Kyu;Choi, Hyung-Jun;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.102-108
    • /
    • 2010
  • Impaction is the cessation of eruption process caused by physical obstacles on the eruption pathway, abnormal tooth position, or lack or space. It often occurs in association with supernumerary teeth, odontogenic tumor, or cystic lesions, and ameloblastic fibroma is one of the odontogenic tumors that can cause impaction of teeth. In many cases, ameloblastic fibroma occurs in association with one or more unerupted teeth. The proper management of ameloblastic fibroma is determined between conservative resection or more aggressive block resection, based size and morphologic features of the lesion and age of the patient. This is a case of a 8 year and 6 month old boy whose lower left permanent molar showed eruption disturbance. The impacted tooth was successfully repositioned favorably through surgical exposure and orthodontic traction using a modified halterman appliance. Long term follow-up, longer than 10 years, is planned considering relatively high recurrence rate and possibility of malignant transformation of ameloblastic fibroma, which cause impaction of the lower left permanent molar in this case.

Study on Physical Properties of Domestic Species I: Sorption, Thermal, Electrical and Acoustic Properties of Pinus Densiflora (국산재의 응용물성연구 I: 소나무(Pinus densiflora)의 수분흡착성 및 열적·전기적·음향적 성질)

  • Kang, Ho-Yang;Byeon, Hee-Seop;Lee, Won-Hee;Park, Byung-Soo;Park, Jung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.70-84
    • /
    • 2008
  • A series of the studies on the applied physical properties of domestic species have been conducted last three years. Pinus densiflora was one of the three species examined for the first year. Because the same apparatus and experimental procedures were used for all species, their results can be easily comparable. The experiments for sorption property were conducted with 20- and 80-mesh wood powder and resulted in their EMC's and sorption isotherms at various heating conditions. The thermal conductivity and diffusivity, and electric resistance and volumetric electric resistivity were measured with a thermal-wire device and a high electric resistance meter. The differences of the thermal and electric properties between quarter- and flat-sawn specimens were observed, which was partially attributed to their anatomical differences. An acoustic measurement system was used to evaluate dynamic MOE and internal friction. This paper provides the useful fundamental data for designing a wood structure, correcting a portable resistance-type moisture meter, and nondestructive testing wood.

A correlation between bruxism and eccentric occlusal interferences (이갈이와 편심위 교합간섭의 상관관계 분석)

  • Lee, Ho-Sun;Kim, Mi-Gyeong;Jin, Soo-Yoon;Kim, Hee-Jung;Lee, Gyeing-je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.253-261
    • /
    • 2018
  • Purpose: The purpose of this study was to analyze correlation between bruxism and occlusal contacts on balancing side. Materials and Methods: The purpose of this study is to compare the difference of group function and balancing side occlusal contacts according to bruxism and sex, A total of 100 adults that aged 26-37 years (39 bruxers and 61 non-bruxers) were examined. The lateral excursion and balanced occlusal contacts were analyzed to determine the correlation with bruxism. The occlusal contacts were recorded by T-Scan system and articulating paper. Results: The group function was the highest in 61.5% of bruxers and 47.5% of non-bruxers. In comparison between males and females, group function was 58.9% in males and 37.0% in females. Occlusal contacts on non-working side occurred in 48 out of 100 patients. There were 51.2% of the cases in the bruxers and 46.0% in the non-bruxers. Statistically, there was no correlation between the bruxism and occlusal contacts on non-working side. There was no correlation between sex and balancing occlusal contacts. Conclusion: There was no significant correlation between bruxism and occlusal contacts on non-working side. The group function was the highest in bruxers when lateral excursion was occurred.