• Title/Summary/Keyword: 검사장치

Search Result 1,046, Processing Time 0.028 seconds

위험기반검사 기법을 이용한 위험관리

  • Kim, In-Tae
    • 방재와보험
    • /
    • s.117
    • /
    • pp.26-33
    • /
    • 2007
  • 위험기반검사는 정상적인 방법이나 사고발생 가능성과 크기에 의해 결정하는 정량적인 방법을 이용해 위험도를 파악하여 검사체계의 운영과 공정 또는 장치의 검사 우선순위를 결정하는 방법으로서, 설비의 안전성을 향상시키고 경비를 절감할 수 있다는 장점이 있다.

  • PDF

Survey for Diagnostic Radiography Examination in Veterinary Hospital (동물병원 영상의학적검사 실태조사)

  • Lee, Won-Jeong;Jo, Sung-Mi
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.177-184
    • /
    • 2022
  • The purpose of this study is surveyed diagnostic radiography (DR) examination in veterinary hospital (VC) including non-ionization radiation such as ultra-sonography and magnetic resonance imaging. From June 1 to June 20. 2021, we surveyed the VC in 00 metropolitan city by using a structural questionnaire which are location of VC and X-ray unit et al.. Data are expressed as a mean with standard deviation for continuous variable or percent for categorical variable using SPSS ver. 26.0. As the first animal to be visited, dogs were the highest with 61.9%, followed by cats with 12.9%. In 87.1% fo cases, DR units were used, and 4 VCs did not. In 27 VCs using DR units, 48.1% separated examination room and control room, 19.8% examined in animal visited, protective clothing was in all VCs, 55.6% were measured radiation exposure dose, 92.6% was responded a necessary for examination education. From the above results, it will help to revise the guidelines for DR units and examination in korea VCs.

Quality Management for Mammography Equipment and Mammography (유방촬영장치와 유방검사를 위한 품질관리)

  • zheng, Hao Yang;Cho, Pyong Kon;Kim, Tae Woo;Kim, Jung Soo;Jang, Hyon Chol;Lee, Mi Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.683-692
    • /
    • 2018
  • Mammography using mammography equipment is a method of examination that is being employed most widely to diagnose the early stages of breast cancer. Detecting or diagnosing a fibrous tissue, micro calcification, or mass in the breast is influenced by the quality management of mammography equipment considerably. Particularly in mammography, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in mammography using mammography equipment.

Computed Tomography and Quality Management (컴퓨터단층촬영장치와 품질관리)

  • Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.221-233
    • /
    • 2020
  • CT(computed tomography, CT) examinations is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. Recently, the number of CT scans is increasing every year due to the high reliability of CT scans. Increasing the number of tests will accelerate the aging of CT devices, which is why the importance of quality management for CT devices is on the rise. Particularly in CT, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in CT.

AC Servo System Design of Digital Radiography Equipment (디지털 방사선 검사장치(DR)의 AC 서보 시스템 설계)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.133-138
    • /
    • 2022
  • Digital radiation inspection equipment is a medical device that deals with human life and requires stability and high reliability. However, this system is currently the most advanced technology and the domestic market is almost occupied by European products including Japan. Therefore, research and development are needed not only to replace domestic medical devices, which are largely dependent on expensive imported products, but also to develop more economical and user-oriented products that are easy to operate and produce devices that lead to accurate diagnosis. In particular, among the digital X-ray systems, the motor driving technology and the mechatronics technology related to the development of mechanical devices have matured to some extent in Korea. In this paper, selection of AC servomotor for digital radiation inspection suitable for imaging purpose, and application of conversion device and control method to check performance and improve problems.

A Machine Vision System for Inspection of Car Sunroof Using SVM Algorithm (SVM 학습 알고리즘을 이용한 자동차 썬루프 장치의 볼트 유무 검사 장비)

  • Kim, Giseok;Lee, Saac;Cho, Jae-Soo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.05a
    • /
    • pp.289-292
    • /
    • 2013
  • 본 논문은 SVM(Support Vector Machine) 학습알고리즘을 이용하여 자동차 썬루프 장치의 볼트 유무를 검사하는 자동차 부품 검사 장비에 관한 것이다. 자동화 시스템은 높은 정밀도와 생산성을 위한 빠른 처리 속도를 요구한다. 이를 위해 본 논문에서는 선형 SVM 학습알고리즘을 활용하여 자동차 썬루프 장치의 볼트 유무를 검사하는 알고리즘을 개발하였다. SVM 알고리즘은 분류를 위한 알고리즘이지만 ROI(Region-Of-Interest) 내의 모든 윈도우에 대한 분류를 수행하여 검출기 역할을 할 수 있도록 한다. 볼트가 있는 경우와 볼트가 없는 경우가 아닌 네거티브 샘플을 확보하기 위해 검출 대상 물체 주변에서 다양한 네거티브 샘플들을 추출한다. 그 결과 물체가 예상 위치에서 다소 빗나가는 경우에도 볼트 유무를 판별할 수 있을 뿐 아니라 볼트의 위치까지 검출할 수 있고, 처리 속도에서 자동화 시스템이 요구하는 수준에 도달함을 실험 결과를 통해 검증한다.

기류 저지법을 이용한 발성시의 공기역학적 검사법 제1보, 정상성인 남녀의 검사치

  • 문영일;김종남;정성민;박미향;이지애;민정하
    • Proceedings of the KSLP Conference
    • /
    • 1994.06b
    • /
    • pp.83-83
    • /
    • 1994
  • 발성기구의 생리학적 연구나 발성장애의 병태를 검사함에 있어서 폐로부터 송출되는 호기의 에너지가 성문에 있어서 어느 정도로 목소리의 음원으로 변환되는 지를 아는 것은 대단히 중요하다. 이것을 알기 위해서는 발성시의 호기류율과 함께 성문하에 있어서의 호기압을 측정하여 발성된 목소리의 강도와의 관계를 조사할 필요가 있다. 기류 저지법을 이용한 발성시의 공기역학적 검사법은 발성장애에 대한 공기역학적 검사의 한 방법으로, 기류 저지법을 사용한 발성시의 호기압(폐내압)측정을 호기류율, 목소리 강도, 높이의 측정과 조합시키는 방법으로 장치는 기류저지용의 회전 셧터를 발성기능 검사장치의 mouth piece에 접촉시킨 것이다. (중략)

  • PDF

Development of Visual Inspection System to the defect of Quad chip (Quad chip의 외관 불량 검사 시스템 개발)

  • Lee, Ji Yeon;Ko, Kuk Won;Han, Chang Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1076-1077
    • /
    • 2015
  • 본 연구에서는 최근 널리 사용되고 있는 QFP(Quad Flat Package)의 소형화 및 대량 생산 Quad chip 공정에서 최종 외관 불량 검사를 위한 기존의 2D 영상 검사 시스템에 3D 영상 검사 시스템을 추가하여 광학 장치를 설계하고 이에 따른 영상처리 알고리즘을 개발하였다. 개발된 검사 장치는 실제 LQFP/TQFP에 생산 공정에 적용되어 불량을 검사에 적용하였으며, 10 회 반복 측정 시 최대 오차는 $1.34{\mu}m$와 측정 오차의 표준편차가 $0.715{\mu}m$으로 요구하는 3차원 불량 검사를 만족할 만한 성능을 보였다.

Development of a Multichannel Eddy Current Testing Instrument(I) (다중채널 와전류탐상검사 장치 개발(I))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoon, Byung-Sik;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.155-161
    • /
    • 2010
  • Recently, the electromagnetic techniques of the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In this study, the synthesizer module and the analog module which are essential to the ECT system were primarily developed. The developed ECT system is basically a multifrequency type which is able to inject the maximum four frequencies based on the frequency and time domain multiplexing method. Conclusively, we confirmed that the EC signal was processed appropriately in each circuit modules, and the Lissajous EC signal was displayed in the impedance plane.