Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF

Digital Imaging Source Identification Using Sensor Pattern Noises (센서 패턴 잡음을 이용한 디지털 영상 획득 장치 판별)

  • Oh, Tae-Woo;Hyun, Dai-Kyung;Kim, Ki-Bom;Lee, Hae-Yeoun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.12
    • /
    • pp.561-570
    • /
    • 2015
  • With the advance of IT technology, contents from digital multimedia devices and softwares are widely used and distributed. However, novice uses them for illegal purpose and hence there are needs for protecting contents and blocking illegal usage through multimedia forensics. In this paper, we present a forensic technique for identifying digital imaging source using sensor pattern noise. First, the way to acquire the sensor pattern noise which comes from the imperfection of photon detector against light is presented. Then, the way to identify the similarity of digital imaging sources is explained after estimating the sensor pattern noises from the reference images and the unknown image. For the performance analysis of the proposed technique, 10 devices including DSLR camera, compact camera, smartphone and camcorder are tested and quantitatively analyzed. Based on the results, the proposed technique can achieve the 99.6% identification accuracy.

Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR) (디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.276-283
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of automatic exposure control (AEC) by analyzing entrance surface dose (ESD) and entropy on using automatic exposure and manual exposure. The experimental method was to measure the dose by placing a semiconductor dosimeter on the Rando Phantom for the Pelvis, Abdomen, Skull, and Chest regions. The DICOM file was simultaneously acquired and then entropy was analyzed by using Matlab. As a result, when using the automatic exposure control, dose of all sites was lower than manual exposure's dose and entropy was high. In addition, paired t-test was performed for each item and p<0.05 was found in each item. In conclusion, the use of automatic exposure control can be a useful method to contribute to the optimization of the exposure dose and the image quality by reducing the amount of unnecessary radiation amount and information loss that can occur in X-ray examination.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant (원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발)

  • Suh, D.M.;Park, M.H.;Hong, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

A Study on the Corrosion Property of Sprinkler Pipe and the Solution (스프링클러 배관의 부식 특성과 대책에 관한 연구)

  • Kim, Dongsung;Cho, Cheol Won;Kim, Byungseon;Lee, Tae Shik
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.2
    • /
    • pp.87-92
    • /
    • 2008
  • This paper investigates the corrosion property of sprinkler pipe and provides the prevention solution. This study examines the property of stainless pipe widely used as sprinkler pipe and performs theoretical studies on the corrosion procedure. It was found that corrosion of the pipes mainly results from deterioration of pipe and wrong installation. The test result is expected to be useful in designing of the pipe system and minimizing of the corrosion.

  • PDF

Development of a Wireless Acoustic Emission System for the Monitoring of Rotating Structures (회전기 진단을 위한 무선식 AE 측정장치 개발)

  • Kwon, O.Y.;Kim, Y.H.;Yoon, D.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.2
    • /
    • pp.15-21
    • /
    • 1991
  • A wireless acoustic emission (AE) system has been developed for continuous monitoring of rotating structures such as turbine rotors. The cable between preamplifier and signal processing unit of a conventional AE system was replaced by the frequency modulated telemetry. The detected signals were modulated and transmitted as an RF signals by the transmitting module, then received and demodulated by the receiving module. The distance between the transmitting and the receiving antennas could be separated up to 10cm within a reasonable signal-to-noise ratio. The simulated AE signals generated by pencil lead breaks from rotating structures were successfully detected using the developed wireless AE monitoring system.

  • PDF

Development of Inspection System for Aluminum Castings with X-Ray TDI Camera (X-Ray TDI Camera를 이용한 알루미늄 주강품 검사장치 개발)

  • Nam, Mun-Ho;Park, Seong-Wook;Kim, Chang-Ho;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1734-1735
    • /
    • 2011
  • In case of inspection on aluminum castings, traditional RT (Radiographic Testing) method have been utilized for its advantages in interpretation, cost and perpetual storage. But it has disadvantages like time consumption in film processing, low efficiency in storage and environmental pollution. In this thesis, a DRS (Digital Radiography System) utilizing X-Ray TDI Camera (Time Delay and Integration Camera) is developed. Inspections on aluminum castings are performed using the developed Digital Radiography System, DRS and reviewed if newly developed system can substitute for the traditional method.

  • PDF

Detection of Oscillation Mark in Slab Surface (슬라브(Slab) 표면에서 오실레이션 마크(Oscillaton mark) 검출 알고리즘)

  • Jeon, Yong-Ju;Yun, Jong-Pil;Choi, Doo-Chul;Kim, Sang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1804_1805
    • /
    • 2009
  • 최근 여러 산업 분야에서는 품질의 향상과 생산성을 높이기 위해 자동화 검사 장치 개발이 활발하게 연구 되고 있다. 본 연구에서는 비전을 이용한 신뢰도 높은 슬라브(Slab) 표면 검사 자동화 알고리즘의 전처리 단계인 오실레이션 마크(Oscillation mark) 검출을 목표로 한다. 슬라브 영상의 경우 조업시에 발생하는 산화 물질인 스케일(Scale)이 영상 전체에 분포하고 있으며, 이러한 스케일은 형태적 특징 및 밝기 특징이 일정치 않기 때문에 오실레이션 마크 검출 성능을 저하 시킨다. 따라서 스케일의 영향을 최소화 하고 효과적으로 오실레이션 마크를 검출하기 위해 가버 필터(Gabor filter)와 수직 투영 프로파일(Vertical projection profile)을 이용한 노이즈 제거 방법을 사용한다.

  • PDF

검정.인증제도 통합모델의 장.단점 비교 분석

  • 황호근;백종배;고재욱;김상렬;김봉호
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.359-364
    • /
    • 2002
  • 산업안전 보건법에서 유해ㆍ위험한 작업을 필요로 하거나 동력에 의하여 작동하는 기계기구로서 유해ㆍ위험방지를 위해 방호조치가 필요한 기계기구 및 설비에 대하여는 방호장치의 설치를 의무화하고 있고 근로자의 안전을 위하여 작업상 필요한 보호구에 대해서는 신규, 수거, 부분검정을 통해 성능검정을 받도록 하는 검정제도를 의무화하고 있다. 그리고 선반, 컨베이어 등과 같은 산업용 기계류나 해외에서 안전인증획득을 목표로 하는 제품 및 재해예방에 기여할 수 있다고 인정되는 제품 등에 대하여 제품의 구조ㆍ성능 그리고 재료의 안전성에 대한 심사ㆍ시험 및 검사 등을 통하여 안전증표의 사용을 인증할 수 있도록 산업안전보건법 제34조 2항 등에서 검사 검정과 같이 의무화하는 것은 아니지만 다소 강제성의 경향을 갖도록 규정하고 있다.

  • PDF