• Title/Summary/Keyword: 검사시험기술

Search Result 396, Processing Time 0.023 seconds

GBAS Flight Testing and Performance Assessment using Flight Inspection Aircraft at Gimpo International Airport (비행검사용 항공기를 이용한 김포국제공항 GBAS 비행시험 및 성능평가)

  • Jeong, Myeong-Sook;Bae, Joongwon;Jun, Hyang-Sig;Lee, Young Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.1
    • /
    • pp.49-61
    • /
    • 2015
  • Ground Based Augmentation System(GBAS) is a system that offers an aircraft within 23 NM radius from the airport precision positioning service and precision approach service using the concept of Differential Global Positioning System(DGPS). After GBAS ground equipment installing at the airport, functionalities and performances of GBAS should be verified through the GBAS ground and flight testing. This paper describes the methods and results for GBAS flight test using the flight inspection aircraft at Gimpo International Airport. From the test results, we confirmed that the VDB data was received without misleading within the VDB coverage of Gimpo International Airport, and VDB field strength, protection level, and course alignment accuracy met the evaluation's criteria.

기계장치의 잔존수명예측 및 평가

  • 김건영
    • Journal of the KSME
    • /
    • v.30 no.2
    • /
    • pp.163-171
    • /
    • 1990
  • 기계 구조물의 수명예측 및 평가에 대하여 기초이론과 실례를 중심으로 기술하였다. 기계설비의 파손방지 및 수명예측, 평가기술은 학문적으로나 산업분야에서나 종합적이므로 제작자, 설계자, 사용자, 연구자, 기술자 등이 서로 긴밀한 협력체제를 구축하여 지속적으로 설계, 재료, 운전, 시험, 검사, 보수 등 각자의 전문분야를 조화 있게 연구개발 하여야만 문제를 해결 할 수 있다는 뜻이다. 따라서 관련종사자는 협력체제를 설비 및 기업특성에 맞게 구축하는 것이 가장 중요하고 시급한 과제이다.

  • PDF

The Precision Test Based on States of Bone Mineral Density (골밀도 상태에 따른 검사자의 재현성 평가)

  • Yoo, Jae-Sook;Kim, Eun-Hye;Kim, Ho-Seong;Shin, Sang-Ki;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.67-72
    • /
    • 2009
  • Purpose: ISCD (International Society for Clinical Densitometry) requests that users perform mandatory Precision test to raise their quality even though there is no recommendation about patient selection for the test. Thus, we investigated the effect on precision test by measuring reproducibility of 3 bone density groups (normal, osteopenia, osteoporosis). Materials and Methods: 4 users performed precision test with 420 patients (age: $57.8{\pm}9.02$) for BMD in Asan Medical Center (JAN-2008 ~ JUN-2008). In first group (A), 4 users selected 30 patient respectively regardless of bone density condition and measured 2 part (L-spine, femur) in twice. In second group (B), 4 users measured bone density of 10 patients respectively in the same manner of first group (A) users but dividing patient into 3 stages (normal, osteopenia, osteoporosis). In third group (C), 2 users measured 30 patients respectively in the same manner of first group (A) users considering bone density condition. We used GE Lunar Prodigy Advance (Encore. V11.4) and analyzed the result by comparing %CV to LSC using precision tool from ISCD. Check back was done using SPSS. Results: In group A, the %CV calculated by 4 users (a, b, c, d) were 1.16, 1.01, 1.19, 0.65 g/$cm^2$ in L-spine and 0.69, 0.58, 0.97, 0.47 g/$cm^2$ in femur. In group B, the %CV calculated by 4 users (a, b, c, d) were 1.01, 1.19, 0.83, 1.37 g/$cm^2$ in L-spine and 1.03, 0.54, 0.69, 0.58 g/$cm^2$ in femur. When comparing results (group A, B), we found no considerable differences. In group C, the user_1's %CV of normal, osteopenia and osteoporosis were 1.26, 0.94, 0.94 g/$cm^2$ in L-spine and 0.94, 0.79, 1.01 g/$cm^2$ in femur. And the user_2's %CV were 0.97, 0.83, 0.72 g/$cm^2$ L-spine and 0.65, 0.65, 1.05 g/$cm^2$ in femur. When analyzing the result, we figured out that the difference of reproducibility was almost not found but the differences of two users' several result values have effect on total reproducibility. Conclusions: Precision test is a important factor of bone density follow up. When Machine and user's reproducibility is getting better, it’s useful in clinics because of low range of deviation. Users have to check machine's reproducibility before the test and keep the same mind doing BMD test for patient. In precision test, the difference of measured value is usually found for ROI change caused by patient position. In case of osteoporosis patient, there is difficult to make initial ROI accurately more than normal and osteopenia patient due to lack of bone recognition even though ROI is made automatically by computer software. However, initial ROI is very important and users have to make coherent ROI because we use ROI Copy function in a follow up. In this study, we performed precision test considering bone density condition and found LSC value was stayed within 3%. There was no considerable difference. Thus, patient selection could be done regardless of bone density condition.

  • PDF

Eddy Current Testing of Weldment by Plus(+) Point Probe (Plus(+) Point Probe를 이용한 용접부 와전류검사)

  • Lee, Hee-Jong;Kim, Yong-Sik;Nam, Mim-Woo;Yoon, Byung-Sik;Kim, Seok-Kon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.426-432
    • /
    • 1999
  • A plus-point eddy current test(ECT) probe was developed to examine the defects on the welds of pumps, valves, and pipings which are the major components of the electric power plants, non-destructive evaluation (NDE) techniques for detecting and sizing the flaws were studied adapting this probe. Differential plus-point ECT probe is consists of two "I"-type coils crossed each other and has an advantage having a small influence on the sensitivity by lift-off variation to the conventional types of probe. The specimens with crack-like electro discharge machining(EDM) notches on the weld of type 304 stainless-steel were fabricated in order to evaluate the plus-point ECT probe response to the flaws. NDE techniques to detect and size the flaws and estimate the flaw type were established with this specimens.

  • PDF

Development of Mathematics Anxiety Scale for Middle School Students & its Validity (중학생용 수학불안 검사 도구의 개발 및 타당화 연구)

  • Ok, Bo-myoung;Lee, Chang Yeon;Ryoo, Byeong Kook
    • Communications of Mathematical Education
    • /
    • v.35 no.3
    • /
    • pp.233-255
    • /
    • 2021
  • The purpose of this study is to develop math anxiety scale for middle school students for planning and implementing math anxiety treatment programs. In this study, we describe the process of developing and validating math anxiety scale for middle school students and detailing exploratory factor analysis and confirmatory factor analysis to verify construct validity. As a result of the study, we developed the Math Anxiety Scale for Middle School Students (MASS-M) of 30 items with four factors: mathematical curriculum content, mathematical attitude, mathematical test, and environment. As a math anxiety factor for middle school students, MASS-M was developed, which includes mathematical anxiety factors such as mathematical test factor and environmental factor, especially mathematical curriculum content factor describing mathematical treatment, and mathematical attitude factor describing psychological treatment. MASS-M, derived from this study, is a standardized scale for measuring math anxiety in middle school students and is expected to serve as the basis for maintaining consistency in research on math anxiety in middle school students and developing programs to treat math anxiety in middle school students.

Analysis of Heat Generation Mechanism in Ultrasound Infrared Thermography (초음파-적외선 열화상 기법에 의한 피로균열 검출에 있어 발열 메커니즘 분석)

  • Choi, Man-Yong;Lee, Seung-Seok;Park, Jeong-Hak;Kim, Won-Tae;Kang, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.10-14
    • /
    • 2009
  • Heat generation mechanism of ultrasound infrared thermography is still not well understood, yet and there are two reliable assumptions of heat generation, friction and thermo-mechanical effect. This paper investigates the principal cause of heat generation at fatigue crack with experimental and numerical approach. Our results show most of heat generation is contributed by friction between crack interface and thermo-mechanical effect is a negligible quantity.

Spin Testing for the Endurance Verification of Gas Turbine Blades (고속회전시험기를 활용한 가스터빈 동익의 내구성 시험)

  • Lee, Dooyoung;Kim, Doosoo;Son, Taeha;Goo, Jaeryang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2018
  • The long-term research and development for the production of domestic blades has been consistently performed. As the direct and indirect results of its nationwide technologies in precision casting have been improved as well as maintenance costs for turbine machinery has been reduced. Whereas, there are still not a few concerns about the reliability of newly manufactured blades in spite of the quality certificate in metallurgical and mechanical properties. A spin tester is a machine that gives centrifugal loading to a rotating part, and its practical application is the overspeed test that is usually used to check the quality of products. A new spin rig has been constructed in KEPCO Research Institute for the purpose of evaluating the reliability of blades. In this paper, the test methodology for low cycle fatigue damage mechanism as well as the overspeed test for newly developed blades is described, and their reliability is evaluated too.

State of the Art in Life Assessment for High Temperature Components Using Replication Method (표면복제기법을 이용한 고온 설비의 수명평가 현황과 적용사례)

  • Kim, Duck-Hee;Choi, Hyun-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.489-496
    • /
    • 2010
  • The power generation and chemical industry have been subjected to further material degradation with long term operations and need to predict the remaining service life of components, such as reformer tube and steam turbine rotor, that have operated at elevated temperatures. As a non-destructive technique, replication method with reliable metallurgical life and microstructural soundness assessment has been recognized with strongly useful method until now. Developments of this method have variously accomplished by new quantitative approach, such as carbide analysis, with A-parameter and grain deformation method. An overview of replication, some new techniques for material degradation and life assessment were introduced in this paper. Also, on-site applications and its reasonableness were described. As a result of having analyzed microstructure by replication method, carbide approach was quantitatively useful to life assessment.

Development of Interface Inspection System for On-board Signal Equipment (열차 차상신호 인터페이스 검사 시스템 개발)

  • Park, Jae-Young;Lim, In-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2324-2329
    • /
    • 2014
  • The inspection of distance to go train control system conducted only when train is in main line or inspecting line, that affects low work efficiency and hazard elements to safe operation. Before or after train operation, the interface test between on-board and wayside signal system must be conducted. In this paper, onboard signal interface inspection system based on the real-time automatic analysis of onboard system status information that is transmitted to the wayside system and the operation status check of the onboard signal device operates as a virtual train information that is transmitted to the onboard system have been proposed. And after building the inspection system to the inspecting track of Daejeon Subway Line 1, Panam Depot, the verification algorithm of proposed interface test and the results was presented. therefore, it has enhanced work efficiency to do not carry train operation of a half hour in test line to test on-board system.

The Development and Validation of a Mobile-based English Speaking Test Convergence Model (모바일 영어말하기평가 융합 시스템 모형 타당도 검사)

  • Kim, Jungtae
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.2
    • /
    • pp.25-31
    • /
    • 2016
  • In the study, a convergence model of a mobile-based English speaking test was developed. Based on the needs analysis from Korean college students, a speaking test App for iOS and Android mobile devices was developed and its test validity was examined. To develop the test, test items, scoring features and scales were developed. The result of the needs analysis survey showed that 69 out of 87 (79.3%) owned Android phones whereas only 17 (19.5%) held iPhones. Based on the result, an English speaking test App was developed. The technologies used for the test included HTML5, the Javasciript bridge technology, Node and Express, and Mongo DB. In the experiment, five examinees took the test. The test validity was obtained in that all the functions of the test were successfully operated and some feedback was gathered.