• Title/Summary/Keyword: 건축요소

Search Result 1,521, Processing Time 0.032 seconds

A Study on the Analysis of Space Arrangement in 'Standard Korea Traditional-Houses Design' (한옥표준설계도의 평면도 공간배치 분석에 관한 연구)

  • Hwang, Yong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.579-586
    • /
    • 2019
  • The object of this study are 32 floor plans types of "Standard Korea Traditional-Houses Design=SKTHD.". The purpose of the research was to enhance the satisfaction level of users by comparing and analyzing the characteristics of the SKTHD. Research decision : 1. It tried to accommodate modern life by including space elements of modern housing, such as the 'entrance space', in the SKTHD. 2. The SKTHD. also favored the southern layout of living rooms and entrance spaces. 3.The number of bedrooms was generally planned to be two to three and it was judged that more various space and bedroom were needed to hold various functions of rural areas. 4. It has been analyzed that the depth of space is deeper to enter the entrance space(E)' than to enter from Thet-maru(TM). And as the depth of space in the Master bedroom is related to personal privacy, it is needed that the depth of space should be sufficiently.

Study on the Pressure Loss of Hoses in a Fire Hose Reel Hydrant (호스릴옥내소화전 호스에 대한 압력손실에 관한 연구)

  • Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.63-67
    • /
    • 2019
  • In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressure loss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure loss increased with increasing length of the reel hose; it was approximately 38.86% based on a 25 m hose. Second, the pressure loss of the reel hose per unit length was estimated to be $.13{\sim}.15kgf/cm^2$. Third, in the pressure loss experiment according to the change in the flow rate, the result was similar to the relation, flow rate - pressure loss (${\Delta}P{\sim}Q^2$), in the piping flow. These results provide basic data on the evaluation of fire pump pressure and the performance-based fire-protecting design of fire hose reel hydrants used in buildings.

A study on the Improvement Spacial Environment through the Strategies of Urban-Core Regeneration based on the Regional Resources -Focused on the Cheongju City- (지역자산기반형 도심재생 전략에 따른 공간환경 개선방안 연구 -청주시를 중심으로-)

  • Bahn, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.191-204
    • /
    • 2018
  • In the era of diversity and creativity, autonomous regional regeneration is being emphasized. Local regeneration effects through local heritage utilization and the value of regional properties are rising. It is very meaningful to find a way to revitalize the urban regeneration system that can transform the facilities, spaces and industries in underdeveloped regions into opportune properties. This study explores the possibility of self-sustaining development by establishing an endogenous self-reliance system through the localization of industrial heritage. Competitive advantage strategies of regional properties are more important than regional comparative advantages. In the future, more attention should be paid to the intangible value of the city. A genuine city revival should be created as a place with cultural identity through artistic ecology, tradition, community, and aesthetics centering on people.

Energy Demand Estimation in Metropolitan Area in Case of Emergency using Spatial Information (공간정보를 활용한 대도시권역 비상시 에너지 수요량 예측)

  • Nam, Gyeongmok;Lee, Hong Chul;Lee, Dong-Eun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.3
    • /
    • pp.105-112
    • /
    • 2019
  • Due to abnormal high temperature, electric power demand has exceeded the backup power reserved for emergency case, hence, resulting in a major power outage. In today's overcrowded cities, the unexpected disruption in energy supply and demand is a major threat to the enormous economic damage and urban malfunctions. Existing methods for estimating the demand of the emergency power source do not lend themselves to predict the actual demand in the spatial dimension of the city. In addition, the reserve power is arbitrarily distributed in the case of emergency. This paper presents a method that predicts the emergency power demand using the spatial distribution of emergency power demand by applying the daily energy consumption intensity and emergency power demand according to urban spatial information and building use.

Development of Estimation Functions for Strong Winds Damage Based on Regional Characteristics : Focused on Jeolla area (지역특성 기반의 강풍피해 예측함수 개발 : 전라지역을 중심으로)

  • Song, Chang Young;Yang, Byong Soo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.13-24
    • /
    • 2020
  • Abnormal weather conditions have lately been occurring frequently due to the rapid economic development and global warming. Natural disasters classified as storm and flood damages such as heavy rain, typhoon, strong wind, high seas and heavy snow arouse large-scale human and material damages. To minimize damages, it is important to estimate the scale of damage before disasters occur. This study is intended to develop a strong wind damage estimation function to prepare for strong wind damage among various storm and flood disasters. The developed function reflects weather factors and regional characteristics based on the strong wind damage history found in the Natural Disaster Yearbook. When the function is applied to a system that collects real-time weather information, it can estimate the scale of damage in a short time. In addition, this function can be used as the grounds for disaster control policies of the national and local governments to minimize damages from strong wind.

A Study on the Improvement of Pedestrian Environment for the Mobility Handicapped on the Use of Personal Mobility Vehicle (개인형 이동수단의 이용에 따른 교통약자의 보행환경 개선에 관한 연구)

  • Lee, Joo-Hyung;Lee, Kyoo-Il
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.2
    • /
    • pp.201-213
    • /
    • 2021
  • Recently, personal mobility has been spreading and using increasing, but the pedestrian environment is getting worse and accidents are also rapidly increasing. Therefore, this study conducts a status survey related to the elements of pedestrian disturbances in personal mobility and identifies the problems. The following measures are presented to improve the pedestrian environment for the mobility handicapped through expert opinion surveys. The movement of individual mobility means in the walking space is prohibited, and the speed limit shall be stipulated to enable the mobility handicapped to walk safely and conveniently. Parking spaces will have to create obstacle zones in the parking area next to the roadway or at the border of sidewalks and roads, and regulations are needed to collect illegally parked vehicles. It is necessary to switch from the existing automobile-oriented road to the road structure considering the use of low and medium-speed vehicles.

A Study on Bearing Capacity of Cast-In-Place Pre-Founded Columns in Top Down Construction Sites (Top Down 공사현장에 적용되는 현장타설 선기초기둥의 지지력에 관한 연구)

  • Byun, Yoseph;Jung, Kyoungsik;Kim, Jongho;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.55-61
    • /
    • 2011
  • Recently, a concept of the downtown area was progressively extended by improvement of rapid transportation system and development of the most advanced telecommunication industries. And underground has become bigger in addition deeper, Excavation methods which construct a structure were changed according to construction environments. Top Down methods which are continuous with architectural plan differ from existing excavation methods innovatively, pre-founded column is an important factor for construction methods, duration, expenses. Therefore, this study considers application by investigative methods according to comparison, analysis on loading test result of on site inspection and estimated results of bearing capacity for structure pre-founded column. As a result, almost designing eclipse appeared prior value which didn't arrive result of load test. Also, evaluate permanent load for the compressive stress acting on head of cast-in-place after basic structure was installed. Then, applying stress generally is reduced by confining effect with foundation.

Experimental Study for Seismic Behavior Analysis of a Fire Protection Riser Pipe System with Groove Joints (그루브 조인트가 설치된 수계소화설비 입상배관계통의 지진거동분석을 위한 실험적 연구)

  • Kim, Sung-Wan;Yun, Da-Woon;Kim, Jae-Bong;Jeon, Bub-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.35-42
    • /
    • 2021
  • In this study, a steel frame that realized the second floor of a structure was fabricated in referring to NFPA 13. In addition, a riser pipe system with groove joints was installed, and a seismic simulation test was performed using static cyclic loading. Cyclic loading tests on the maximum allowable side sway of seismic design standards for buildings in Korea were conducted using actuators to analyze the seismic behavior of the riser pipe system and major piping elements due to the deformation of the steel frame structure or the displacement-dominant behavior caused by the relative displacement between the structural members in the event of a seismic load. Moreover, the deformation angle of the riser pipe system was measured using an image measurement system because it is difficult to measure using the conventional sensors.

Legal Issues of Medical Institution Remodeling (의료기관 리모델링의 법적 제문제)

  • Shin, Tae-Seop;Chung, Mi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.8
    • /
    • pp.294-304
    • /
    • 2021
  • Medical institutions remodel existing hospital buildings rather than construct buildings to satisfy patient satisfaction and enhance competitiveness with other medical institutions. Medical institution remodeling is gradually increasing due to enhanced laws and systems to improve the quality of medical services and the level of patient safety. However, prior studies were discussed only within a limited range, including architectural elements, about medical institution remodeling. Therefore, this study aims to provide basic data to medical institutions planning future remodeling by examining the legal issues of medical institution remodeling in various ways. Medical institution remodeling extends the construction period due to restrictions on construction conditions, and causes damage such as noise and dust to patients. So it is necessary to prevent damage to patients in advance and to support appropriate remodeling of medical institutions. Therefore, it is necessary to prepare an Act on promotion of and support for remodeling of medical institutions. In addition, medical institutions should prepare a checklist for voluntary compliance with construction standards, preventive measures and post-improvement measures, and measures for infection and radiation exposure in hospitals.

Effect of Groundwater Flow on the Behavior of Circular Vertical Shaft (지하수 유동을 고려한 원형수직구 거동분석)

  • Park, Heejin;Park, Jongjeon;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.6
    • /
    • pp.29-39
    • /
    • 2022
  • This study investigates the behavior of a circular vertical shaft wall in the absence and presence of a groundwater table. The effects of wall deflection, backfill settlement, and earth pressure distribution around the circular vertical shaft caused by sequential excavations were quantified. The vertical shaft was numerically simulated for different excavation depths of the bearing layer (weathered soil, weathered rock, soft rock) and transient and steady-state flows in the absence of a groundwater table. The backfill settlements and influential area were much larger under transient flow conditions than in steady-state flow. On the contrary, the horizontal wall deflection was much larger in steady state than in the transient state. Moreover, less settlement was induced as the excavation depth increased from weathered soil to weathered rock to the soft rock layer. Finally, the horizontal stresses under steady- and transient-state flow conditions were found to exceed Rankine's earth pressure. This effect was stronger in the deeper rock layers than in the shallow soil layers.