• Title/Summary/Keyword: 건축물 상태

Search Result 238, Processing Time 0.035 seconds

Development of MEMS Inclinometer Sensor System (MEMS형 경사계 센서의 유효성 평가)

  • Ha, Dae Woong;Kim, Jong Moon;Park, Hyo Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.271-274
    • /
    • 2013
  • Inclinometer sensors are widely applied in many fields. Especially in the field of construction of high-rise buildings also measure the horizontal and vertical help has been applied to monitor. Recent micro electro-mechanical system(MEMS) technology with the development of the many sensors have been developed. In this paper, a MEMS inclinometer is based on a MEMS accelerometer. The sensor can measure the angle of inclination using the relationship between static acceleration and gravity acceleration from an accelerometer. From this principle, inclinometer has been developed that has more accurate. The accuracy is proved by the experiment with laser displacement. Results in the experiment express high-accuracy, stability and economics of MEMS inclinometer. In conclusion, wireless MEMS inclinometer sensor is expected to be applicable in the areas of construction and many other industries with accurate and convenient monitoring system.

A Study on Combustion Experiments of Color Nonwoven (칼라 부직포의 연소실험에 관한 연구)

  • Min, Se-Hong;Im, Sang-Bum
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.99-106
    • /
    • 2011
  • Experiments of Cone calorimeter test and Lift spread flame apparatus test are carried out in order to appraise fire hazard in color nonwoven used mostly on the spot in construction works. As the result, in color nonwoven combustibility is discovered not firing flame in surface, but firing under state of combustible gas occuring in the state of melting. In the case of Lift spread flame apparatus test, color nonwoven is very brittle which almost no flame spread owing to contracting and break by firing strength. The following data are agree with basis: total heat release is 2.66 MJ/$m^2$, limited combustible material (10 min) of incombustible rating appraisal in interior material of building, and incombustible materials (5 min) 8 MJ/$m^2$ in spite of the above data mentioned, those data are only as basis of interior finish, and so I cannot judge color nonwoven have incombustible rating retain through the above data. Accordingly, the basis of incombustible rating and experiment method about exterior finish must be arranged also.

Implementation of Personalized Mobile Agent System using Agilla in Ubiquitous Sensor Network (USN환경에서 Agilla를 이용한 개인화된 모바일 에이전트 시스템 구현)

  • Kim, Gang-Seok;Lee, Dong-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.203-210
    • /
    • 2011
  • The current sensor network analyzes the data collected by the sensing of fixed sensor nodes and provides a service. However, this method cannot actively handle the state and the change in the position of people, 'the target for sensing and the change in the environment', including home automation, building automation and real-time road & weather information, and healthcare environment, etc. To support a dynamic situation which is appropriate for an individual in this diverse environment, it is necessary to provide actively differentiated specific information according to the movement of people and the changes in the environment. In this study, a individualized sensor mobile agent middleware which provides the individualized information (the location of fire incidence and the trace for the path of spread), has been realized through the sensor network environment constructed by the installation of wireless sensor nodes mounted with mobile agent middlewares in buildings.

A Study on Reformability and Application of Tensegrity Modules (텐서그러티 모듈의 변형 및 응용에 관한 연구)

  • Choi, Sun-Young;Park, Sun-Woo;Park, Chan-Soo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.2 s.16
    • /
    • pp.73-79
    • /
    • 2005
  • Tensegrity is a relatively new structural system based on the use of continuous tension-discontinuous compression. Of course, a much more detailed structural investigation would be necessary, but at least in order to achieve the intended purpose, it is essential to understand the structural principles and the fundamental forces of tensegrity. Once this point is established, the applications of them to architecture are described, as well as the characteristics of these structures. Then, in spite of the controversial definitions to explain these systems, several examples of tensegrity prototypes or modules constructed in iESD(Institute of Environmental Structure Design) are presented to illustrate the feasibility of tensegrity as a lightweight structure. In this work, consequently, the reformability and application of tensegrity modules have also been researched in architecture, after the patterns of basic module as well as fundamental definition are introduced.

  • PDF

A Study on Power Conversions of the Power Supply for Fire Safety Use (소방용 전원장치의 전력변환에 관한 연구)

  • Kwon, Seong-Pil;Lee, Jang-Won;Yook, Gil-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.462-465
    • /
    • 2011
  • 최근 우리나라에서는 대형 화재사고가 빈번히 발생함에 따라 그로 인한 재산 및 인명피해가 날로 증가하고 있는 실정이다. 따라서 건축물 내에서 화재가 발생할 경우 인명피해를 최소화하기 위하여 피난유도설비의 설치를 의무화하고 있다. 지금까지 일반적으로 가장 널리 사용되고 있는 피난유도설비로는 유도등이 있으며, 최근 들어 피난유도선의 설치도 다중이용업소를 중심으로 점차 확대되어가고 있는 추세이다. 피난유도설비는 평상시 이용되는 교류 상용전원에 의해서뿐만 아니라 비상시 이용되는 직류 비상전원에 의해서도 정상적으로 작동되어야 하기 때문에, 피난유도설비의 전원장치는 주어진 전원으로부터 주어지는 교류 또는 직류를 발광부에 맞게 일정한 전압과 주파수로 변환시켜주어야 한다. 실제로 LED(발광다이오드) 유도등은 상용전원으로부터 220V의 교류를 받아서 전원장치에서 정류변환을 통해 얻어지는 낮은 전압 24V의 직류를 이용하며, 대부분의 유도등 백라이트로 사용되고 있는 CCFL(냉음극형광램프)에는 상용전원으로부터 220V, 60Hz 교류를 인가받아 전원장치에서 정류 역변환을 통해 만들어진 100kHz의 고주파 교류가 공급된다. 더욱이 유도선의 전원장치에서는 상용전원 220V, 60Hz의 교류를 인가받아 정류 역변환 및 교류변환 과정을 차례로 거쳐 최종적으로 100V, 400Hz의 교류로 전환하여 TFEL(박막전계발광) 소자로 전송하게 된다. 한편, 상용전원이 차단된 상태에서도 전원장치는 마찬가지로 비상전원으로부터 24V의 직류를 공급받아 인버터를 통해 역변환 하여 100kHz의 고주파 교류를 만들어 주거나 추가적인 교류변환을 거쳐 100V, 400Hz의 교류로 변환시켜 내보낸다. 본 연구에서는 상대적으로 복잡한 전력변환 회로들을 포함하고 있는 유도선의 전원장치를 개선하여, 전원장치의 연결가능길이를 기존의 60m에서 최대 100m까지 연장시킴으로써, 터널이나 지하도와 같은 곳에서 특히 경쟁력을 갖게 될 것으로 기대된다.

  • PDF

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.

Estimation Method of the Design Wind Load of Soundproof Wall Using GIS (GIS를 이용한 방음벽의 설계풍하중 산정방법)

  • Lee, Dong-Ho;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.23 no.5
    • /
    • pp.75-85
    • /
    • 2015
  • Recently deformed or destroyed of soundproof wall by local winds and typhoon has increased. This research proposed the estimation method of the design wind load of soundproof wall using spatial information analysis based on 1:5,000 digital map and performed comparative analysis with actual application cases. According to the result of quantitative evaluation using GIS, the surface roughness in the downtown area packed with buildings was III and the surface roughness in the suburban district with a relatively small number of buildings was II and the surface roughness in the district packed with open areas and typical farmhouses was I. This shows that the wind load of the soundproof walls reflecting the actual surface conditions was estimated. If the quantitative GIS analysis presented in this study is applied to wind-resistant design of soundproof walls, it is supposed that this will be helpful in more rational wind-resistant design by remedying the existing problem in which the wind load varies depending on designer's subjectivity.

An Experimental Study on Strength Development of Micro Grinding Fly-ash Mortar - Effect of Alkali Activator and High Temperature Curing on the Compressive Strength of Concrete - (미분쇄한 플라이애시 모르타르의 강도증진 방안에 관한 연구 - 알칼리 자극제와 고온양생이 강도에 미치는 영향 -)

  • Cho, Hyun-Dae;Jaung, Jae-Dong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.39-47
    • /
    • 2010
  • Fly ash has the advantages, among others, of improving the characteristics of concrete, reducing the price of concrete products, improving the durability, and reducing hydration heat. However, when added in mass, it leads to problems such as insufficient concrete intensity, increase of AE use, and others, resulting in a limitation of the use volume. Therefore, this study is undertaken to solve the problems associated with themass use of fly ash through the high concentration powder ($4000{\sim}8000cm^2/g$) of fly ash, curing method, the addition of an alkali stimulation agent and others for the purpose of increasing the added value of the fly ash. The research showed that the intensity manifestation has an outstanding status, with the hydrates reaching a very stable condition if the rate of addition of a stimulation agent is appropriately used with the heightening of the fineness of the fly ash in the temperature range of $40^{\circ}C$, and if the applicable study is continued, it is likely to result ineffective value generation on the massive replacement of fly ash.

Experimental Study on Bond Strength between Carbon Fiber Sheet and Concrete (탄소섬유쉬트와 콘크리트의 부착강도 실험연구)

  • 유영찬;최기선;최근도;이한승;김긍환
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.168-174
    • /
    • 2001
  • Carbon fiber sheet(CFS) has been widely used for strengthening of the concrete building structures due to its excellent physical properties such as high strength, light weight and high durability. Bond strength or behavior, on the other hands, between carbon fiber sheet and concrete is very important in strengthening the concrete member using CFS. Therefore the bond failure mechanism between CFS and concrete should be fully verified and understood. This study is to investigate the bond strength of CFS to the concrete by the direct pull-out test and the tensile-shear test. In the direct pull-out tests, the bond strength under the various environmental conditions such as curing temperature, surface condition on concrete and water content of concrete are evaluated. Also, the effective bond length, lu and the average bond stress, $\tau$y are examined in the tensile-shear tests. Based on the test results, it is concluded that the curing temperature is the most critical element for the bond strength between CFS and concrete. And, the proper value of lu and $\tau$y is recommended with 15 cm and 9.78∼ 11.88 kgf/$\textrm{cm}^2$ respectively.

A Research of the Residents' Availability and Health Effectiveness Based upon the Types of Green Roof (옥상녹화 유형별 거주자 이용행태와 건강효과)

  • Kim, Soo-Bong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.60-68
    • /
    • 2012
  • The purpose of this research is to identify green roofs based on how to utilize the diverse space. This research also aims to discover the correlation between the use of the green roof and the overall level of the public's health condition, through which it is intended to grasp the health effects by means of the space of the green roof. The current use patterns of the green roof have been identified generally to have more than 60% accessibility, less than 30 minutes of short-tenn use, relaxation or removing stress, enjoy the view of the surrounding, smoking, walking and exercise. It will be highly effective to furnish facilities and plants for tree planting, and to get financial maintenance & management subsidy for the purpose of revitalizing the green roof. It is expected that if the green roof is created in educational institutes, hospitals and shopping centers, where the current level of health conditions is generally low, it will contribute in promoting the city dwellers' health benefits. In addition, the physical environmental renovation through establishing the green roof will bring about producing a healthy city because the emotional health benefits also will make a positive impact upon physical health.