• Title/Summary/Keyword: 건축물 상태

Search Result 238, Processing Time 0.058 seconds

Optimal Design of Linear Quadratic Regulator Restrict Maximum Responses of Building Structures Subject to Stochastic Excitation (확률적 가진입력을 받는 건축구조물의 최대응답 제한을 위한 선형이차안정기의 최적설계)

  • 박지훈;황재승;민경원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.6
    • /
    • pp.37-46
    • /
    • 2001
  • In this research, a controller design method based on optimization is proposed that can satisfy constraints on maximum responses of building structures subject to around excitation modeled by partially stochastic process. The class of controllers to be optimized is restricted to LQR. Weighting matrix on controlled outputs is used as design variable. Objective function, constraint functions and their gradients are computed by the parameterization of control gain with Riccati matrix. Full state feedback controllers designed by proposed optimization method satisfy various design objectives and their necessary maximum control forces are computed for the production of actuator. LQG controllers composed of Kalman filter and LQR designed by proposed method perform well with little deterioration. So it is possible to design output feedback controllers satisfying constraints on various maximum responses of structures.

  • PDF

Edge Detection and ROI-Based Concrete Crack Detection (Edge 분석과 ROI 기법을 활용한 콘크리트 균열 분석 - Edge와 ROI를 적용한 콘크리트 균열 분석 및 검사 -)

  • Park, Heewon;Lee, Dong-Eun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.2
    • /
    • pp.36-44
    • /
    • 2024
  • This paper presents the application of Convolutional Neural Networks (CNNs) and Region of Interest (ROI) techniques for concrete crack analysis. Surfaces of concrete structures, such as beams, etc., are exposed to fatigue stress and cyclic loads, typically resulting in the initiation of cracks at a microscopic level on the structure's surface. Early detection enables preventative measures to mitigate potential damage and failures. Conventional manual inspections often yield subpar results, especially for large-scale infrastructure where access is challenging and detecting cracks can be difficult. This paper presents data collection, edge segmentation and ROI techniques application, and analysis of concrete cracks using Convolutional Neural Networks. This paper aims to achieve the following objectives: Firstly, achieving improved accuracy in crack detection using image-based technology compared to traditional manual inspection methods. Secondly, developing an algorithm that utilizes enhanced Sobel edge segmentation and ROI techniques. The algorithm provides automated crack detection capabilities for non-destructive testing.

An Experimental Study on the Application of Horizontal Daylight Duct System in Building Interior Space (실내 건축공간에 있어 수평채광덕트 시스템의 적용에 관한 실험적 연구)

  • 이성주;김회서
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.36-43
    • /
    • 2004
  • The purpose of this paper was development of modified horizontal daylight duct for reflector of light intake, location of outlet diffuser and size as applicable daylighting system for buildings and, verified applicable possibility base on analysis of daylighting performance through full-scale model test. Experimental result showed that ratio of illumination for light duct was measured 0.3∼0.4% in interior of a room on clear sky. Also, light duct had wide distribution of illumination than duct about 150[cm] and was decided efficient lighting energy saving because of high daylight performance in case of application actual building during daytime.

Evaluation of flood runoff reduction facilities based on the decrease in CN: case studies from Gimcheon Pyeonghwa district (CN 저감을 기반으로 한 홍수유출저감시설의 평가: 김천 평화분구지역을 중심으로)

  • Zhu, Ju Hua;Lee, Hyungtaek;Yoo, Chulsang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.247-247
    • /
    • 2016
  • 최근 한국은 지구환경 변화에 따른 기후변화 영향으로 집중호우로 인한 도시홍수가 급증하고 있다. 기상변화에 의한 집중호우와 급증된 도시화로 인해 불투수면적이 증가하고, 이는 홍수시 유출량을 증가시켜 기존 하도 또는 내배수 시스템의 적정 소통량을 초과하여 홍수를 발생시킨다. 그리하여 홍수피해를 저감하기 위해 구조적 및 비구조적 홍수방어대책들이 마련되어 시행하고 있다. 하지만 내수배제시설의 경우, 기존의 치수계획이 빗물펌프장 등 일부 구조물에 한정되어 있기에 해당 홍수방어시설에 과도한 부담이 있는 실정이다. 따라서 유역 내에 투수면적을 최대한 확보하여 토양의 수문학적 특성을 유지 보전시켜 첨두유량, 도달시간, 직접유출량을 도시 개발 이전상태와 최대한 유사하도록 하는 홍수유출저감시설을 설치하여 빗물펌프장과 같은 홍수방어시설에 대한 과부하를 덜어준다. 이러한 홍수유출저감시설은 크게 저류시설과 침투시설로 구분된다. 홍수유출저감시설들은 해당 지역의 입지특성, 재해저감효과 및 제약조건에 따라 설치 위치 및 규모가 결정된다. 또한 저감효과는 CN 값의 변화로 정량화하여 시설의 적합성을 판단할 수 있다. 본 연구에서는 SWMM 모형을 이용하여 김천시의 평화배수분구지역을 대상으로 CN 저감을 기반으로 한홍수유출저감시설을 평가하고자 한다.

  • PDF

A Plan for Establishing IOT-based Building Maintenance Platform (S-LCC): Focusing a Concept Model on the Function Configuration and Practical Use of Measurement Data (IOT 기반 건축물 유지관리 플랫폼 구축(S-LCC) 방안 : 기능구성과 계측 데이터 활용을 위한 개념 모델을 중심으로)

  • Park, Tae-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.611-618
    • /
    • 2020
  • The reliability of the results of LCC analysis is determined by accurate analytical procedures and energy data from which the uncertainty is removed. Until now, systems that can automatically measure these energy data and produce databases have not been commercialized. Therefore this paper proposes a concept model of an S-LCC platform that can automatically collect and analyze electric energy consumption data of equipment systems using the IOT, which is the core tool in the Fourth Industrial Revolution and operates the equipment system efficiently using the analyzed results. The proposed concept model was developed by the convergence of existing BLCS and IOT and was comprised of five modules: Facility Control Module, LCC Analysis Module, Energy Consumption Control Module, Efficiency Analysis Module, and Maintenance Standard Reestablishment Module. Using the results of LCC analysis deduced from this system, the deterioration condition of an equipment system can be identified in real-time. The results can be used as the baseline data to re-establish standards for the maintenance factor, replacement frequency, and lifetime of existing equipment, and establish new maintenance standards for new equipment. If the S-LCC platform is established, it would increase the reliability of LCC analysis, reduce the labor force for entering data and improve accuracy, and would also change disregarded data into big data with high potential.

A Study on the Feasibility of the Timing for the Implementation of Energy-Saving Plan of Buildings Based on the Approval of Business Plan and Construction Permit (건축물에너지절약계획서의 사업계획승인, 건축허가에 따른 적용시점의 타당성 연구)

  • Kim, Dae-Won;Kim, Young-Il;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.265-270
    • /
    • 2012
  • The delay in the construction permit for the building, which obtained the approval of business proposal, may lead to a difference in the maintenance cost ranging between 20% and 30% in the neighborhood where the residents moved in, along with the new project under construction in the surrounding area amidst rigorous regulations that aim to promote energy-saving and the heightened interest of the public in energy conservation, and such problem would become the major source of serious public complaints. Thus, the energy-saving plan needs to be prepared when the approval is granted to the business plan. In order to prevent public complaints or ensure effectiveness of government's energy plan, it may be effective to apply the energy-saving plan based on current standards upon the award of construction permit when two years have elapsed since the date of the scheduled commencement of construction or when the start of construction is delayed as stipulated in the Article 18 of the Enforcement Decree of Housing Act. If the energy-saving plan and related technologies are merely the parts of license and permit process without fully serving their purposes and functions, it would be waste of time to deploy a lot of workforce and review and seek consultation. The government or owners of buildings need to fully understand the energy-saving aspects and exert effort to enhance the energy efficiency of buildings.

A Study on the Safety of Evacuation according to Evacuation Delay Time and Fire Door Openness: Based on Residence Types (피난 지연시간의 적용과 방화문 개방 정도에 따른 피난 안전성 확보에 관한 고찰 : 주거형태를 중심으로)

  • Seo, Dong-Gil;Kim, Mi-Seon;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.156-165
    • /
    • 2020
  • In this paper, the application of evacuation delay time (Cognition time + initiation time) and examine the degree of opening of fire doors in households for evaluating evacuation safety and suggest a realistic alternative. In order to proceed with this study, first of all, the preliminary investigation on evacuation safety evacuation of residential-type buildings (Apartment, urban living houses, etc.) among the performance-oriented design targets of Gwangju Metropolitan City, which was implemented until June 2018. Then, for the two representative types that are commonly used among the previously surveyed buildings, evacuation delay time is applied to W1, W2, and respectively simulating the opening of the doors is applied to th full open, 1/4 open, the leakage gap and evacuation safety evaluation was performed. As a result of evaluating evacuation safety was found that it is difficult to secure evacuation safety regardless of evacuation delay time W1 and W2 when the fire door is fully open and 1/4 open, Only when the leakage gap is applied evacuation safety was ensured even if evacuation delay time W2 was applied. Therefore, when a residential building is subject to performance-oriented design, evaluating the application of W2 rather than W1 is considered for evacuation delay time to reflect concern about privacy infringement due to CCTV installation, etc. In order to secure the Smoke blocking performance of the fire door and to improve the performance-oriented design, I would like to propose to consider the method of applying a leak gap to the degree of opening of the fire door. Through this, it is expected that the performance-oriented design will be a step further by performing evacuation safety evaluation with more realistic data.

Suggestion of Load and Resistance Factored Design Value for PHC Bored Pile (PHC 매입말뚝의 하중저항 설계정수 제안)

  • Park, Jong-Bae;Park, Yong-Boo;Lee, Bum-Sik;Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.3 no.3
    • /
    • pp.279-286
    • /
    • 2012
  • The limit states design method is replacing the allowable stress design method worldwide, e.g. the design code of ISO and various construction codes of Korea are adopting the reliability based limit state method. This paper proposed LRFD design value which is one of limit states design method for the PHC bored pile used as building foundation. This paper analysed 81 load test results and the bearing design(Meyerhof method & SPT-CPT conversion method), and proposed LRFD value for each design reliability Index 2.33 and 3.0 for PHC bored pile. LRFD value of PHC bored pile represents 0.36~0.44 for Meyerhof method and 0.24~0.31 for SPT-CPT conversion method according to the deign reliability index.

A Experimental Study on the Response Characteristics for Fire Detector by Combustibles (가연물에 따른 화재감지기 응답특성에 관한 실험연구)

  • Choi, Moon-Soo;Hong, Sung-Ho;Lee, Sang-Ho;Park, Sang-Tae;Yoo, Song-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.514-517
    • /
    • 2011
  • 화재감지 및 경보시스템의 설계 목표는 화재발생 초기 단계에서 화재징후를 발견, 피난의 개시를 신속하게 통수하는 것이다. 화재감지기는 다양한 건물 및 환경에 설치되기 때문에 주위 온도 및 가연물의 종류 등 환경적 측면을 심층적으로 고려하지 않으면 적절하게 감지하지 못하는 경우가 발생할 수 있다. 즉, 가연물 종류 등을 고려한 설계에 따라 설치된 화재감지기는 화재시 설계치 대로 조기에 화재를 감지하여 화재 예방 및 화재로 인한 피해를 최소화할 수 있는 것이다. 본 논문은 화재시 조기에 화재를 감지기하여 건축물내 인명피난을 목적으로 설치되는 화재감지기의 응답특성을 분석한 연구이다. 화재감지기의 응답특성을 분석하기 위하여 다양한 가연물을 발생시키고 화재감지기 종류별로 설치한 다음 각 화재감지기의 응답특성을 분석하였다. 그 결과 정온식 열감지기는 열방출률이 적은 화재를 조기에 감지하는 것에 적합하지 않은 것으로 나타났다. 광전식 연기감지기는 회색 계통의 목재류 화재성상에서 응답특성이 떨어졌고, 동일한 공간에서 화원의 수평거리와 동작시간이 비례한다고 볼 수 없었다.

  • PDF

A study on water supply and demand analysis to secure the ecological flow required for the fish habitat (어류서식처에 필요한 환경생태유량 확보를 위한 유역 물수급 분석 연구)

  • Kim, Young Jun;Kim, Jong-Suk;Lee, Joo-Heon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.472-472
    • /
    • 2022
  • 과거 우리나라 하천관리 정책은 이수와 치수 기능 위주로 개발됨에 따라 하천 수량이 감소하고 오염이 심화되는 등 하천환경이 계속적으로 악화되어 왔다. 시대가 변화함에 따라 하천환경 개선에 대한 패러다임과 사회적 요구의 변화로 인간과 자연이 더불어 살 수 있는 친환경적인 하천을 조성하고 훼손 또는 변화된 하천을 복원하는 노력이 필요하다. 하지만, 본래 자연상태의 하천으로 완벽하게 회복 될 수없다는 한계점이 있기 때문에 하천이 갖고 있는 하천공학적 기능을 최대한 유지하면서도 다양한 수생생물의 서식처의 기능도 되살아나게 해야 하는 복합적인 목적을 갖춰야 하며, 하천 수생생물의 서식처 복원을 위해서는 하천생태계에 필요한 환경유량의 정량적인 평가와 확보방안 및 공급방안의 검토가 동시에 필요하다. 본 연구에서는 하천유지유량이 생태계 기준으로 고시된 하천인 감천유역을 대상으로 물수급 분석을 통해 환경생태유량 확보할 수 있는 방안을 고려하고자 하였다. 물수급 분석을 위해 K-weap을 활용하였으며, 공급 우선순위, 저수지 운영 변화 등을 통해 제한된 수자원을 효율적으로 활용하여 방안을 제시하고자 하였다. 추후 하천 수생생물의 생애주기와 계절적 변화 등을 고려한다면, 더욱 합리적이고 지속가능한 환경생태유량 확보방안을 제시할수 있을 것으로 기대된다.

  • PDF