• Title/Summary/Keyword: 건물 안전 확인

Search Result 126, Processing Time 0.027 seconds

The Development of High Pressure Long Distance Fire-fighting Hose with Phosphorescent Performance (축광 성능을 갖는 고압용 장거리 호스 개발에 관한 연구)

  • Han, Yong-Taek;Na, Byung-Gyun;Choi, Jin-Seong;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.63-69
    • /
    • 2017
  • This study describes the development of a long-distance hose for ultra-high pressure operation, which can be used in conjunction with an ultra-high pressure pump and can be effectively applied to the fire suppression of high-rise buildings and a long, large tunnels. Also, it has phosphorescent properties, which can help to secure the withdrawal route of the fire-fighters when they are threatened by the fire. We developed an ultra-high pressure hose aiming at a pressure of 3 MPa and a flow rate of 2000 lpm and developed an ultra-high pressure fire hose that can withstand this very high pressure by using a double jacket, triple polyurethane coating and warf (Wp) of 52. In order to ensure the performance of the developed ultra-high pressure hose, its structure, appearance, leakage at high pressure, length and elongation were inspected by a certified certification agency, who also subjected it to a peeling test, friction test, breaking pressure test and free fall test. Also, it was studied in addition to the luminescent high-pressure hose for fire-fighting. In the phosphorescence test, the luminance measurement value was more than the reference value of the luminance test after 40 minutes, which confirmed that its performance was satisfactory for fire-fighting products. In the future, if such an ultra-high pressure fire hose were commercialized and applied in the field, it could contribute to securing improved fire suppression and safer exit from fires, as compared to the fire hoses currently used in the suppression of fires in skyscraper buildings and long tunnels.

Consequence Analysis for Fire and Explosion Accidents in Propylene Recovery Process (프로필렌 회수공정에서 화재 및 폭발 사고의 피해영향 해석)

  • Han, Seong-Hwan;Lee, Hern-Chang;Park, Kyoshik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.52-60
    • /
    • 2014
  • This study aims to suggest risk management plan including safety measures through hazard identification followed by consequence analysis in petrochemical plants. Consequence analysis was performed through practical release scenario by using PHAST RISK(ver. 6.7) software in the propylene recovery process(PRP). As results, consequences by fire or explosion accidents in the depropanizer zone, deethanizer zone and heat pump zone were relatively larger than other else zones among six process zones in the PRP. In the case of jet fire, it is recommendable not to install residence building within 200 m of the process zone. Additionally, process zones having large inventory or high pressure must be prevented from accidents and required to establish quick response against accidents.

A Study on Human Behavioral Pattern and the Design of Escape Stair (인간행동습성과 피난계단의 설계에 관한 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.3-12
    • /
    • 1998
  • The purpose of this study is to examine that the escape stair of high-rise buildings has to be designed as a left-handed stair(a stair being designed to turn left whicle we go down the ground floor) judging from fire-safety point of view. Most of Korean people are right-handers. In case of right-handers it was found that the occupant's escape speed using a left-handed stair is more convenient and fast than of a right-handed stair(a stair being designed to turn right while we go down the ground floor). But most of the escape stair of high-rise buildings in Korea was designed as a right-handed stair. The fire code therefore should be provided that the escape stair of high-rise buildings should be a left-handed stair.

  • PDF

Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System (특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구)

  • Lee, Su-Kyung;Hong, Dae-Hwa
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.85-90
    • /
    • 2011
  • This study of the vestibule of pressurizing smoke control system installed in domestic high-rise buildings for evacuation in case of fire, when the door is open to forming characteristics of the air flow was analyzed using fire dynamics simulator and analyzed of variance. Vestibule which is compartment of the design condition, air flow in the exhaust damper was formed severe turbulence confirming preceding research. The door position is in the range of formed vortex, unsteady flow of air occurs at the point that the door could be confirmed. According to the NFSC 501A, door to symmetrically separate the average of 10 points or more as measured from the average of wind speed to do is based. Under these conditions, it is difficult to measure the characteristics of the upper air flow of upper points. so measuring points are subdivided by more than 64 points method presented in TAB because severe deviation of wind speed.

Extraction of Concrete Slab Surface Cracks using Fuzzy Inference and SOM Algorithm (퍼지 추론 기법과 SOM 알고리즘을 이용한 콘크리트 슬래브 표면의 균열 추출)

  • Kim, Kwang-Baek
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.2
    • /
    • pp.38-43
    • /
    • 2012
  • It is necessary to measure cracks on concrete slab surface accurately in concrete structure maintenance for the stability of the structure. However, in real world, the process is done by time consuming and ineffective manual inspection. Although there have been some studies to provide computerized inspection methods, they are vulnerable to rugged surface or noise due to the influence of the light or environmental reasons. In this paper, we propose a new method that extracts not only undistorted cracks but minute cracks that were often regarded as noise. We extract candidate crack areas by applying fuzzy method with R, G, and B channel values of concrete slab structure. Then further refinement processes are performed with SOM algorithm and density based cutoff to remove noise. Experiment verifies that the proposed method is sufficiently useful in various crack images.

Small UAV Failure Rate Analysis Based on Human Damage on the Ground Considering Flight Over Populated Area (도심 지역 비행을 위한 지상 인명 피해 기반 소형무인기 고장 빈도 분석)

  • Kim, Youn-Sil;Bae, Joong-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.9
    • /
    • pp.781-789
    • /
    • 2021
  • In this paper, we quantitatively analyzed the required UAV(Unmanned Aerial Vehicle) failure rate of small UAV (≤25kg) based on the harm to human caused by UAV crash to fly over the populated area. We compute the number of harm to human when UAV falls to the ground at certain descent point by using population density, car traffic, building to land ratio, number of floors of building data of urban area and UAV descent trajectory modeling. Based on this, the maximum allowable UAV failure rate is calculated to satisfy the Target Level of Safety(TLS) for each UAV descent point. Then we can generate the failure rate requirement in the form of map. Finally, we divide UAV failure rate into few categories and analyze the possible flight area for each failure rate categories. Considering the Youngwol area, it is analyzed that the UAV failure rate of at least 10-4 (failure/flight hour) is required to access the residential area.

A Study on the Performance Improvement Plan of Inflowing Air Emission (유입 공기의 배출 성능 개선방안에 관한 연구)

  • Lee, Hye-Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.241-251
    • /
    • 2022
  • Purpose: In the event of a fire in a high-rise building, if the smoke control area is not effectively protected, smoke or flames enter the stairwell, making it difficult to evacuate. When inflowing air is discharged from a closed corridor, a negative pressure is formed in the corridor, the pressure in the smoke control area becomes excessively high, and the force required to open the door during evacuation is exceeded. Also, if the air introduced into the hallway is not exhausted, the smoke may flow back into the smoke control area. This paper tried to identify the problems caused by the inflowing air and to find out how to improve the performance. Method: Using the CONTAM program, simulations were performed with the basic conditions and the modified conditions. Result: If the inflowing air was discharged from the sealed corridor, overpressure occurred in the Smoke Control Area and exceeded the opening force, and the prevent smoke backflow was insufficient in the layer where the inflowing air was not discharged. Conclusion: "Differential pressure exhaust damper" application, simultaneous opening of two exhaust dampers, and automatic window installation between corridors and outdoors improved the exhaust performance of inflowing air.

GPR Analysis on Underground Features and Foundation Structure of Cheomseongdae, Gyeongju (GPR 탐사를 통해 본 경주 첨성대 기초 및 주변의 유구 분석)

  • Oh, Hyundok;Kwon, Moonhee;Jang, Hangilro
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.264-271
    • /
    • 2019
  • Cheomseongdae in Gyeongju, known as an astronomical observatory, is a cultural monument with great historical, academic, and artistic value, as its unique shape is preserved well in its original form. The outer structure, ground stability, and seismic reliability of Cheomseongdae have been assessed by numerous researchers through various scientific methods, but research on the underground structure has been insufficient. This paper contains detailed models of the underground structure of Cheomseongdae interpreted in 2D and 3D images based on the data acquired through GPR surveys conducted of features in and around the base of Cheomseongdae. As a result, the existence of twelve small features arranged in a circle, although only about half of them remain, was confirmed at a depth of 0.4 - 0.6m. Furthermore, a structure three bays long (north-south direction) and four bays wide (east-west direction) was detected beneath Cheomseongdae at the depth of 0.7 - 1.0m. Other than 2 layers of foundations as is known, a square structure with the dimensions of 7m × 7m is situated at a depth of 0.6m, directly under Cheomseongdae, and what is reading that is expected to be the foundation structure of Cheomseongdae was detected and confirmed. This foundation structure is circular with a diameter in the east-west direction of 11m and in the north-south direction of 12m. The northern, western, and eastern edges of this foundation structure are about 1m away from the foundation of Cheomseongdae, whereas the the south side extends to about 5m wide.

An Analysis of Termite(R. speratus kyushuensis) Damage to Nationally Designated Wooden Architectural Heritage in Korea (국가지정 목조건축문화재의 흰개미(R. speratus kyushuensis) 피해 현황 분석)

  • KIM, Sihyun;CHUNG, Yongjae
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.2
    • /
    • pp.102-111
    • /
    • 2022
  • Termites are a group of social insects that are one of the primary causes of damage to wooden architectural heritage. Since termite damage impairs the authenticity and structural stability of cultural heritage, it is imperative to prevent it. This study examines the extent of termite damage to wooden architectural heritage as part of efforts to prevent termite damage to nationally designated wooden architectural heritage sites across the country. The extent of termite damage to each cultural heritage was assessed qualitatively and quantitatively and comparatively analyzed by region using the results of the "Investigation on Biological Damage to Wooden Architectural Heritages" conducted by the National Research Institute of Cultural Heritage from 2016 to 2019. It involved 362 nationally designated wooden architectural heritages(25 national treasures, 157 treasures, 180 national folklore cultural heritages) and 1,104 buildings. The results were as follows: termite detection dogs reacted at 317(87.6%) of the 362 wooden heritages, with visible termite damage observed in 185 cases(51.1%). Furthermore, termite damage was confirmed using one of two methods(detection dogs or visual inspection) in 324 cases(89.5%). Of the 1,104 buildings, termite detection dogs reacted at 668(60.5%), while 339(30.7%) showed visible termite damage. Employing one of the two methods, damage was confirmed in 702 buildings(63.6%). The country was categorized into nine regions(Seoul Metropolitan Area, Gangwon, Chungbuk, Chungnam, Jeonbuk, Jeonnam, Gyeongbuk, Gyeongnam, and Jeju) to examine the termite damage rate and the degree of damage to each cultural heritage according to location. Termite detection dogs reacted to more than 70% of the cultural heritage in all regions. Visible damage was minimal in the Seoul metropolitan area(32.1%) and Gangwon(21.4%) but severe in Chungnam(65.6%), Jeonnam(67.3%), and Gyeongnam(68.2%). By quantifying the degree of termite damage of each cultural heritage as a ratio of the absence of termite damage among the total absence, the average termite damage of the cultural heritage across the country was 9.2%. Regional variance analysis showed that the cultural heritage in Jeonbuk and Jeonnam showed a statistically significantly higher degree of termite damage than the cultural heritage in the Seoul metropolitan area, Chungbuk, and Gyeongbuk. This paper comprehensively analyzed termite damage to nationally designated wooden architectural heritage. The findings are expected to be valuable in establishing policies for the preservation and management of cultural heritage sites in the future.

The Comparison of Various Turbulence Models of the Flow around a Wall Mounted Square Cylinder (벽면에 부착된 사각 실린더 주변 유동에 대한 난류모델 비교연구)

  • Bae, Jun-Young;Song, Gi-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.4
    • /
    • pp.419-428
    • /
    • 2020
  • The flow past a wall mounted square cylinder, a typical and basic shape of building, bridge or offshore structure, was simulated using URANS computation through adoption of three turbulence models, namely, the k-ε model, k-ω model, and the v2-f model. It is well known that this flow is naturally unstable due to the Karman vortex shedding and exhibits a complex flow structure in the wake region. The mean flow field including velocity profiles and the dominant frequency of flow oscillation that was from the simulations discussed earlier were compared with the experimental data observed by Wang et al. (2004; 2006). Based on these comparisons it was found that the v2-f model is most accurate for the URANS simulation; moreover, the k-ω model is also acceptable. However, the k-ε model was found to be unsuitable in this case. Therefore, v2-f model is proved to be an excellent choice for the analysis of flow with massive separation. Therefore, it is expected to be used in future by studies aiming to control the flow separation.