• Title/Summary/Keyword: 건물 높이

Search Result 377, Processing Time 0.023 seconds

Studies on Distribution, Characterization and Detoxification of Shellfish in Korea 1. A Study on the Distribution of Paralytic Shellfish Poison (한국산 주요패류에 대한 독의 분포, 특성 및 제독에 관한 연구 1. 마비성패류독의 분포에 관하여)

  • DONG Dong-Suck;SHIN Il-Shik;CHO Hak-Rae;KIM Ji-Hoe;PYEUN Jae-Hyeung;PARK Young-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.2
    • /
    • pp.113-126
    • /
    • 1988
  • Paralytic shellfish poison(PSP) accmulate in shellfish as a result of feeding toxic dinoflagellates. The shellfish do not seem to be harmed by the toxins, but become toxic to humans and other animals that feed on them. The purpose of this study was to investigate the distribution and changes of PSP by species of shellfish, collected area and collected month. Also, the correlation between PSP and toxic dinoflagellate, Protogonyaulax tamarensis, was investigated. Five hundred and six samples of 13 kinds of shellfish for PSP bioassay were collected at the shellfish growing area of Pusan, Masan, Chungmu, $Samch\check{o}npo, Y\check{o}su, Mokpo and Daech\check{o}n$ located in South Korea during the study period from May, 1985 to Octcber, 1987. Most of the samples submitted were free from PSP except sea mussel, short - necked clam and ark shell. Among the intoxicated samples, PSP was most often detected in sea mussel. PSP was detected mainly in spring$(February\~May)$ in the southern coast of Korea. In case of Pusan, exceptionally, toxic sea mussel have been found even June and July in 1987. The toxicity score of toxic shellfishes examined was ranged from 23.44 to $150.26{\mu}g/100g$ of edible meat and toxicity of sea mussel was higher than other toxic shellfishes. By the study of anatomical distribution of PSP in sea mussel collected at Masan in Febuary and March, 1986, the toxin accumulated in digestive gland was about $70\%$ of all. There was no significant correlation between toxicity of sea mussel and cell numbers of P. tamarensis that one of the causitive organism of PSP during the studying period in Masan area. There was almost no difference in toxicity of sea mussel by water depth of collection, but toxicity of surface shellfish was a little higher than those of 3.5, and 7.0m depth.

  • PDF

Seismic Response Evaluation of NPP Structures Considering Different Numerical Models and Frequency Contents of Earthquakes (다양한 수치해석 모델과 지진 주파수 성분을 고려한 원전구조물의 지진 응답 평가)

  • Thusa, Bidhek;Nguyen, Duy-Duan;Park, Hyosang;Lee, Tae-Hyung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.1
    • /
    • pp.63-72
    • /
    • 2020
  • The purpose of this study is to investigate the effects of the application of various numerical models and frequency contents of earthquakes on the performances of the reactor containment building (RCB) in a nuclear power plant (NPP) equipped with an advanced power reactor 1400. Two kinds of numerical models are developed to perform time-history analyses: a lumped-mass stick model (LMSM) and a full three-dimensional finite element model (3D FEM). The LMSM is constructed in SAP2000 using conventional beam elements with concentrated masses, whereas the 3D FEM is built in ANSYS using solid elements. Two groups of ground motions considering low- and high-frequency contents are applied in time-history analyses. The low-frequency motions are created by matching their response spectra with the Nuclear Regulatory Commission 1.60 design spectrum, whereas the high-frequency motions are artificially generated with a high-frequency range from 10Hz to 100Hz. Seismic responses are measured in terms of floor response spectra (FRS) at the various elevations of the RCB. The numerical results show that the FRS of the structure under low-frequency motions for two numerical models are highly matched. However, under high-frequency motions, the FRS obtained by the LMSM at a high natural frequency range are significantly different from those of the 3D FEM, and the largest difference is found at the lower elevation of the RCB. By assuming that the 3D FEM approximates responses of the structure accurately, it can be concluded that the LMSM produces a moderate discrepancy at the high-frequency range of the FRS of the RCB.

Experimental Evaluation of Bi-directionally Unbonded Prestressed Concrete Panel Impact-Resistance Behavior under Impact Loading (충돌하중을 받는 이방향 비부착 프리스트레스트 콘크리트 패널부재의 충돌저항성능에 대한 실험적 거동 평가)

  • Yi, Na-Hyun;Lee, Sang-Won;Lee, Seung-Jae;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.485-496
    • /
    • 2013
  • In recent years, frequent terror or military attacks by explosion or impact accidents have occurred. Examplary case of these attacks were World Trade Center collapse and US Department of Defense Pentagon attack on Sept. 11 of 2001. These attacks of the civil infrastructure have induced numerous casualties and property damage, which raised public concerns and anxiety of potential terrorist attacks. However, a existing design procedure for civil infrastructures do not consider a protective design for extreme loading scenario. Also, the extreme loading researches of prestressed concrete (PSC) member, which widely used for nuclear containment vessel, gas tank, bridges, and tunnel, are insufficient due to experimental limitations of loading characteristics. To protect concrete structures against extreme loading such as explosion and impact with high strain rate, understanding of the effect, characteristic, and propagation mechanism of extreme loadings on structures is needed. Therefore, in this paper, to evaluate the impact resistance capacity and its protective performance of bi-directional unbonded prestressed concrete member, impact tests were carried out on $1400mm{\times}1000mm{\times}300mm$ for reinforced concrete (RC), prestressed concrete without rebar (PS), prestressed concrete with rebar (PSR, general PSC) specimens. According to test site conditions, impact tests were performed with 14 kN impactor with drop height of 10 m, 5 m, 4 m for preliminary tests and 3.5 m for main tests. Also, in this study, the procedure, layout, and measurement system of impact tests were established. The impact resistance capacity was measured using crack patterns, damage rates, measuring value such as displacement, acceleration, and residual structural strength. The results can be used as basic research references for related research areas, which include protective design and impact numerical simulation under impact loading.

Chronological observation of intestinal lesions of rots experimentally infected with Echinostoma hortense (흰쥐의 실험적 호르틴스극구흡충 감염에 있어서 장 병변에 대한 경시적 관찰)

  • 이순형;노태영
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.1
    • /
    • pp.45-52
    • /
    • 1990
  • Intestinal histopathological changes due to infection with Echinostcma hortense (Trematoda) were studied in rats after experimental infection with the metacercariae. The metacercariae were obtained from the tadpoles of Rana nigrcmaculata, a second intermediate host infected in the laboratory. Total 18 albino rats(Sprague-Dawley) were given 200 matacercariae each and sacrificed on the day 1, 3, 7, 11, 22 or 44 post-infection(PI) Segments of- the small intestine at 1, 3, 5, 8 and 30 cm posterior to the pylorus(PTP) were rejected and studied histopathologically. 1. The flukes were seen to have intruded into the intervillous space in the upper small intestine at early stages(1∼3 days PI), however, they were located mainly in the intestinal lumen at later stages(7∼44 days PI) . The flukes were sucking and destroying the epithelial layers of villi with their oral and ventral suckers. 2. Histopathological changes of the intestine were recognizable in as early as 1∼3 days after infection, and the changes became severer as the infection progressed. 3. The intestinal mucosa was histopathologically characterized by villous atrophy and crypt hyperplasia throughout the infection period. Major villous changes were blunting, fusion, severe destruction and loss of epithelial layers of villi. Villous/crypt(V/C) height ratio was remarkably reduced from 3 : 1 in controls to 1 : 1 in severely infected animals. In the stroma of villi, inaamma- tory cell infiltrations, vascular congestion, edema, and/or fibrosis were recognized. The goblet cells were increased in number after 11 days PI. It was revealed in the present study that the pathological changes in the intestine of rats infected with E. hortense were chieay confined to the mucosal layer of the upper small intestine, however, the changes were very severe accompanying remarkable destruction of villi and loss of mucosal integrity, and persistent until 44 days PI.

  • PDF

The Effects of Negative- and Positive- Charged Surfactants on In vitro DM Digestibility and the Growth of Ruminal Mixed Microorganisms (양(+) 이온성 및 음(-) 이온성 계면활성제 첨가가 반추위 혼합 미생물에 의한 In vitro 건물소화율 및 미생물 성장에 미치는 영향)

  • Lee, S.J.;Shin, N.H.;Kim, W.Y.;Moon, Y.H.;Kim, H.S.;Ha, J.K.;Lee, S.S.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.647-656
    • /
    • 2007
  • In order to investigate the effects of supplemental ionic surfactants in in vitro ruminal fermentation, N-Lauroylsarcosine sodium salt(N-LSS) and sodium dodecyl sulfate(SDS) for negative(-) ionic surfactant, and hexadecylpyridinium chloride monohydrate(HPCM) and hexadecyltrimethyl ammonium bromide(HTAB) for positive (+) ionic surfactant were supplemented by 0.05% and 0.1% into the Dehority’s artificial medium containing rice straw(1mm) as a substrate. In vitro DM digestibility, the growth of rumen mixed microbes, pH, cumulative gas production and SEM(Scanning Electron Microscopy) observation of microbial attachment on rice straw particle were investigated through the experiment composing 9 treatments (two supplemental levels of two positive ionic(+) surfactant, two supplemental levels of two negative(-) ionic surfactant) including the control. The sample collection was at 6, 12, 24, 48 and 72 h post fermentation with 3 replications per treatments. DM digestibility in treatments supplemented (+) or (-) surfactants almost stopped afterward 12 h fermentation, in vitro DM digestibility at 72 h post fermentation in the ionic surfactants was at half level of that of the control(P<0.05). Accumulative gas production in in vitro was less(P<0.05) with addition of ionic surfactants compared to the control. The amount of rumen mixed microbes recovered from in vitro incubation fluid pleateaued at 12 h post fermentation for the positive (+) ionic surfactants, but steadily increased as fermentation time elapsed for the control. Rumen microbial growth rate was significantly(P<0.05) low in the negative(-) ionic surfactant compared to the control. pH of the incubation fluid was ranged from 6.02 to 7.20, and was the highest in the negative(-) ionic surfactants, and was the lowest in the control(P<0.05). In SEM observation, rumen microbial population attached on rice straw particle was less with addition of ionic surfactants than the control. In conclusion we could not found any positive effects of negative- and positive- charged surfactants on rumunal fermentation characteristics and rumen microbial growth rates.

Retrieval of High Resolution Surface Net Radiation for Urban Area Using Satellite and CFD Model Data Fusion (위성 및 CFD모델 자료의 융합을 통한 도시지역에서의 고해상도 지표 순복사 산출)

  • Kim, Honghee;Lee, Darae;Choi, Sungwon;Jin, Donghyun;Her, Morang;Kim, Jajin;Hong, Jinkyu;Hong, Je-Woo;Lee, Keunmin;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.2_1
    • /
    • pp.295-300
    • /
    • 2018
  • Net radiation is the total amount of radiation energy used as a heat flux for the Earth's energy cycle, and net radiation from the surface is an important factor in areas such as hydrology, climate, meteorological studies and agriculture. It is very important to monitoring the net radiation through remote sensing to be able to understand the trend of heat island and urbanization phenomenon. However, net radiation estimation using only remote sensing data is generally causes difference in accuracy depending on cloud. Therefore, in this paper, we retrieved and monitored high resolution surface net radiation at 1 hour interval in Eunpyeong New Town where urbanization using Communication, Ocean and Meteorological Satellite (COMS), Landsat-8 satellite and Computational Fluid Dynamics (CFD) model data reflecting the difference in building height. We compared the observed and estimated net radiation at the flux tower. As a result, estimated net radiation was similar trend to the observed net radiation as a whole and it had the accuracy of RMSE $54.29Wm^{-2}$ and Bias $27.42Wm^{-2}$. In addition, the calculated net radiation showed well the meteorological conditions such as precipitation, and showed the characteristics of net radiation for the vegetation and artificial area in the spatial distribution.

Influence of Micrometeorological Elements on Evapotranspiration in Rice (Oryza sativa L.) Crop Canopy (포장(圃場)에서 벼 군락(群落)의 미기상(微氣象) 요소(要素)들이 증발산량(蒸發散量)에 미치는 영향(影響))

  • Kim, Jong-Wook;Kang, Byeung-Hoa;Lee, Jeong-Taek;Yun, Seong-Ho;Im, Jeong-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.25 no.3
    • /
    • pp.231-241
    • /
    • 1992
  • To study the relationships between major micrometeorological elements and their influences on evapotranspiration(ET) in the canopy of two rice cultivars, Daecheongbyo and Samgangbyo, synoptic meteorological factors, micrometeorological elements and ET from the canopy and biomass production were observed at various growth stages in the paddy field of Suwon Weather Forcast Office in 1989. ET from the rice community was highly correlated with the following factors in order of pan evaporation>air temperature>leaf temperature>solar radiation>sunshine duration>difference in vapor pressure depicit(VPD)>water temperature. ET observed showed higher correlation with the evaporation from small pan than that from Class A pan. Varietal difference would be noted in the relationships between ET in Samgangbyo canopy and the evaporations observed from the pans, with which closer a correlation was found in Samgangbyo than in Daecheongbyo. The ratio of canopy ET to the evaporation from Class A pan was maintained over 1.0 through the growth stages with the maximum of 1.9 at the late August. The evaporation observed from Class A pan was amounted to 71.9% of that from small pan. ET was better correlated with solar radiation than with net radiation which reached about 66% of solar radiation. Maximum temperature showed higher correlation with ET than mean air temperature, and also wind speed of 1m above ground revealed positive correlation. The relative humidity, however, had no correlation with the exception of ET in rainy days. A regression model developed to estimate ET as a function of meteorological elements being described with $R^2$ of 0.607 as : $ET=-5.3594+0.7005Pan\;A+0.1926T_{mean}+0.0878_{sol}+0.025RH$.

  • PDF

Heat Budget Analysis of Light Thin Layer Green Roof Planted with Zoysia japonica (한국잔디식재 경량박층형 옥상녹화의 열수지 해석)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.190-197
    • /
    • 2012
  • The purpose of this study was to evaluate thermal environment and heat budget of light thin layer green roof through an experiment in order to quantify its heat budget. Two concrete model boxes($1.2m(W){\times}1.2m(D){\times}1.0m(H)$) were constructed: One experiment box with Zoysia japonica planted on substrate depth of 10cm and one control box without any plant. Between June 6th and 7th, 2012, outside climatic conditions(air temperature, relative humidity, wind direction, wind speed), evapotranspiration, surface and ceiling temperature, heat flux, and heat budget of the boxes were measured. Daily maximum temperature of those two days was $29.4^{\circ}C$ and $30^{\circ}C$, and daily evapotranspiration was $2,686.1g/m^2$ and $3,312.8g/m^2$, respectively. It was found that evapotranspiration increased as the quantity of solar radiation increased. A surface and ceiling temperature of those two boxes was compared when outside air temperature was the greatest. and control box showed a greater temperature in both cases. Thus it was found that green roof was effective in reducing temperature. As results of heat budget analysis, heat budget of a green roof showed a greater proportion of net radiation and latent heat while heat budget of the control box showed a greater proportion of sensible heat and conduction heat. The significance of this study was to analyze heat budget of green roof temperature reduction. As substrate depth and types, species and seasonal changes may have influences on temperature reduction of green roof, further study is necessary.

Study on Reduction Effect of the Non-Point Pollutants through Riparian Buffer Zones (비점오염부하 저감을 위한 수변완충지대의 효율적 조성 연구)

  • Choi, I-Song;Kim, Sung-Won;Jung, Sang-Jun;Woo, Hyo-Seop;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1793-1797
    • /
    • 2007
  • 한강 "수변구역"에서 비점오염물질의 공공수역 유입을 억제하기 위한 다양한 방법들 중에서 보편적이고 자연친화적인 방법은 다양한 생물의 서식공간이며, 동시에 본류로 유입되는 과정에서 수질을 정화시키는 수질개선 공간인 수변완충구역, 또는 지대를 설정하여 관리하는 것이다. 그러나 이러한 수변완충지대 효과 분석 및 설정에 관한 연구는 국내에서 아직 수행되지 않았다. 본 연구의 목적은 수변구역의 자정능력을 높이는 것은 물론 그 밖의 하천 연안에서 비점오염물질의 차단과 처리능력을 증진시키고 수변 생태계의 서식처 보전 및 복원을 위해서 수변완충지대의 수질정화 기술개발과 생물다양성을 창출하는 수변완충지대 조성 기법을 개발하는데 있다. 본 연구에서는 기존 수변완충지의 추가적인 조성과 보완, 시험완충지 생태구조 및 기능 기초조사, 시험완충지 오염부하 저감효과의 실험 및 분석, 수변완충지대 설치 구상 등의 연구를 수행하였다. 수행 지역은 한강수계 지역으로 남한강 수변인 경기도 양평군 병산리에서 실시하였으며, 잔디와 갈대, 갯버들, 혼합지역, 자연그대로의 상태(대조지역)의 5 구역으로 구분하였고, 깊이별로 샘플을 채취하여 유입수와 표면유출, 하부유출을 비교해 보았다. 연구 결과, 5 가지 구역 중 잔디 구역의 SS, T-N, T-P, TOC의 제거 효율이 각각 76.7%, 85.2%, 97.6%, 83.3%로 가장 좋은 오염물질 제거 효율을 보였으며, 깊이 별 분석에서는 표면유출에서 하부유출로 갈수록 월등한 효율을 보였다. 따라서 본 연구를 통하여 비점오염원에 대한 한강수계의 수자원 보호 효과를 기대할 수 있고, 수변완충지대의 조성, 유지관리기술의 개발을 통한 수변완충지대의 계획과 설계에 직접적인 기여를 할 수 있으며, 수변구역에 설치 가능한 Riparian Buffer Zone의 중요성과 효율성을 알려 현재 하상 저니 준설 및 폭기 위주의 사업에서 생태 공학적 복원을 적극 고려한 정화사업으로 확대 추진하고자 한다.해결책을 얻어내는 상호보완적인 결과를 추구한다. 그가 디자인하는 작품은 전형적인 이미지를 내포하지 않는다. 즉 그의 작품은 기존의 가치와 이념적인 것은 배제하고, 창의적인 개념을 도출하였다.형모서리는 건물 특화 성격이 강하므로 불가피할 경우 소형 액센트 광고 위치를 미리 벽면으로 할애하는 것이 경관 및 입면계획에 유리한 것으로 분석되었다. 불확실도 해석모형 등의 새로운 기능을 추가하여 제시하였다. 모든 입출력자료는 프로젝트 단위별로 운영되어 data의 관리가 손쉽도록 하였으며 결과를 DB에 저장하여 다른 모형에서도 적용할 수 있도록 하였다. 그리고 HyGIS-HMS 및 HyGIS-RAS 모형에서 강우-유출-하도 수리해석-범람해석 등이 일괄되게 하나의 시스템 내에서 구현될 수 있도록 하였다. 따라서 HyGIS와 통합된 수리, 수문모형은 국내 하천 및 유역에 적합한 시스템으로서 향후 HydroInformatics 구현을 염두에 둔 특화된 국내 수자원 분야 소프트웨어의 개발에 기본 토대를 제공할 것으로 판단된다.았다. 또한 저자들의 임상병리학적 연구결과가 다른 문헌에서 보고된 소아 신증후군의 연구결과와 큰 차이를 보이지 않음을 알 수 있었다. 자극에 차이가 있지 않나 추측되며 이에 관한 추후 연구가 요망된다. 총대장통과시간의 단축은 결장 분절 모두에서 줄어들어 나타났으나 좌측결장 통과시간의 감소 및 이로 인한 이 부위의 통과시간 비율의 저하가 가장 주요하였다. 이러한 결과는 차가운 생수 섭취가 주로 결장 근위부를 자극하는 효과를 발휘하는 것이 아닌가 해석된다. 이와 같은 연구결과를 통해 생다시마를 주원료로 개발된 생다시마차와 생다시마 음료가 만성 기능성 변비 증세를 개선하는 효능이 잠재적으로 있음을 확인하였다. 그러나 생약제재의 변비약 수준으로 변비 개선 효능을 증대하기 위해서는 재료 배합비의 개선이나 대장 운동기능을 향상시키는 유효성분의 보강 등이 필요하다는 점도 알 수 있었다.더불어 산화물질 해독에 관여하는

  • PDF

A Study on Proposal of Landscape Management Improvement on the Quantitative Analysis of National Parks (국립공원(國立公園) 자연경관(自然景觀)의 계량적(計量的) 분석(分析)을 통(通)한 경관관리(景觀管理) 개선방안(改善方案)에 관(關)한 연구)

  • Kim, Sei Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.1
    • /
    • pp.32-41
    • /
    • 1991
  • This study is focusted to the national park of Korean typical mountain Chi-ri, its visual resources of forests, and practiced inspectind course by way of hypothesis and tests, to show visual resource management objectively, and that of quantitative basic data. spatial image structure measured by Semantic Differential(S.D.) Scale was shown through factor analysis algorithm for the analyzing psychological amount and examined the flowing out of decisive factor and the objective importance related mutual factors by appling the measurement of visual quality. Also, it has been investigated the differences between the degrees of expectation which is used before and of satisfaction which is used, by appling instrumental expectation theory. And showed patterns of investigation area through factor analyzing algorithm. As a national Park, visual factors that have natural landscape harmonized forest, sky, surface of the water, curious stones and rocks, temples should be escalate their values affirmatively so as to be the scenery of pointed direction and enjoyable, and it is needs the techniques visual resource management and its controlling technique to make artificial structures more intentional planning and systemical setting. Manmade distinctive quality in the spatials that affect complementally or harmonizingly, should be received considering relations between the distifution and joining which in line with various visual presenting massive factors. More than that, it is needed united basic standard to the beauty of arrangements which contain visual continuity considered balance between nature and human work, simplicity of structural types, assimilation, emphasis, unification of different factors and pro rata.

  • PDF