• Title/Summary/Keyword: 건물재료

Search Result 363, Processing Time 0.023 seconds

A Study on Flame Spread Prevention of Sandwich Panel (복합자재 화재확산방지구조에 대한 연구)

  • Cho, Nam-Wook;Kim, Do-Hyun;Shim, Ji-Hun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.84-90
    • /
    • 2015
  • Multi-layered material (sandwich panel) consists of double-sided steel plate which is incombustible material or similar material and core material which is not incombustible material. In case of sandwich panel which uses combustible material as insulation, flames spread inside the steel plate at the time of fire so that it is difficult to extinguish fire from the outside and flames spread rapidly and may cause the building to collapse. The current Building Act requires the sandwich panel to secure fire-retardant performance according to the purpose and size of building. In this study, the fire spreading prevention structure applied to partial exterior walls was applied to multi-layered material and its effect was measured through full scale fire test and the possibility to secure fire safety of buildings by applying the fire spreading prevention structure to multi-layered material in future was presented.

An Experimental Study on the Freeze-Thaw Resistance of High-Strength Light Weight Aggregate Concrete (고강도 경량골재콘크리트의 동결융해 저항성에 대한 실험적 연구)

  • 한상묵;최세규;김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.125-132
    • /
    • 1998
  • 경량골재 콘크리트의 내구성과 경제성에 대한 인식 부족으로 조경재료나 인공토양 둥 구조부재 이외의 분야에 사용되고 있는 국내 실정에 비해서, 구미 여러나라에서는 고강도 경량골재를 장지간 교량과 고충건물에 사용하고 있다. 경량골재 콘크리트는 구조물의 재료비 단순비교에 있어서도 경제성이 있을 뿐만 아니라, 자중감소로 인한 구조적, 기하학적 장점도 있으며, 또한 고강도 경량골재의 개발로 경량골재가 가지고 있는 여러 문제점을 해소하여 사용성과 내구성에 있어서 보통골재 콘크리트와 큰 차이가 없는 상황이다. 그러나국내에서 생산된 경량골재는 닫힌 공극보다 열린 공극을 많이 내포하고 있어 수분흡수가 많고, 특히, 동결융해에 대한 내구성에 취약한 문제점을 가지고 있다. 본 논문에서는 내동해성 향상을 위해 10종류의 고강도 경량골재 콘크리트 공시체를 제작하여 실리카 흄, 물.시멘트비, AE제, 강섬유 등을 실험 변수로 하여동결융해 실험을 수행하였다. 연구결과 실리카흄, 물.시멘트 비는 어느 정도 내동해성을 향상시키지만 근본적인 해결방안이 되지 못하며, AE제를 첨가한 공시체와 강섬유를 사용한 공시체는 동결융해 내구성 지수가 90%이상으로 측정되어 내동해성을 개선시킬 수 있는 요소로 나타났다.

자기냉동/냉장고와 공조기

  • 이종석
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.6
    • /
    • pp.49-54
    • /
    • 2001
  • 1990년대 중반부터 후반에 결쳐 미국의 Astronautics사와 Ames연구소에 의한 공동연구결과는 자기냉동이 실현 가능한기술이며 가스액화,음식 냉동 및 저장, 대규모 건물 공조 등에 있어서 기존의 증기압축냉동에 필적할 만하다는 것을 밝혔다. 더 최근의 연구와 개발 노력은 자기장 원(source)으로 $Nd_2Fe_{14}B$ 영구자석배열을 이용한 회전식 자기냉동기가 가정용 공조기나 냉동/냉장고에 사용될 수 있음을 나타내고있다. Gd 금속구를 사용한 2단 자기 냉동/냉장고의 예비설계는 냉동실 온도가 $-12^{\circ}C(10^{\circ}F)$, 냉동실 온도가 $-1^{\circ}C(30^{\circ}F)$에서 전체 성능계수 3 그리고 냉각능력 120W를 얻을 수 있음을 제시한다. 자기장 원으로서 개선된 영구자석 배열을 이용한다면 카르노 효율의 60%와 성능계수 4.5에 이를 수 있을 것으로 보여진다. 그리고 자기냉동은 오존층 파괴물질 (CFC's)이나 온설가스(HCFC's와 HFC's)를 사용하지 않기 때문에 깨끗한 환경을 만드는데 기여한다. 동시에 상용 Gd으로부터 거대한 자기열량효과를 가진 재료인 $Gd_5(Si_2Ge_2)$를 kg 단위로 생산할 수 있는 정도로 연구가 진전되었다. 이 신재료를 저렴한 가격에 얻을 수 있게 됨으로써 Gd 금속을 자기냉매로 사용하도록 설계 되었던 공조기나 냉동/냉장고의 효율이 더 좋아질 것으로 예상된다.

  • PDF

New Technique on the Improvement of Earthquake-Resistant Performance for the Retrofitting of Existing Reinforced Concrete Beam-Column Joints (철근콘크리트 보-기둥 접합부의 내진성능 개선 보강 신기술)

  • 하기주
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.73-81
    • /
    • 2004
  • In this study, experimental research was carried out to improve earthquake-resistant performance for the retrofitting of reinforced concrete beam-column joints using carbon fiber materials in existing reinforced concrete building. Six reinforced concrete beam-column joints were constructed and tested to evaluate the retrofitting effect of test variables, such as the retrofitting materials and retrofitting region(plastic hinge, beam-column joint) under load reversals. Test results show that retrofitting specimen(RPC-CP2, RPC-CR, RJC-CP, RJC-CR), using new materials(carbon fiber plate, carbon fiber rod and carbon fiber sheet), designed by the improvement of earthquake-resistant performance and ductility, attained more load-carrying capacity and stable hysteretic behavior.

Ambient Vibration Testing and System Identification for Tall Buildings (고층건물의 자연 진동실험 및 시스템판별)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-33
    • /
    • 2012
  • Dynamic response measurements from natural excitation were carried out for three 18-story office buildings to determine their inherent properties. The beam-column frame system was adopted as a typical structural form, but a core wall was added to resist the lateral force more effectively, resulting in a mixed configuration. To extract modal parameters such as natural frequencies, mode shapes and damping ratios from a series of vibration records at each floor, the most advanced operational system identification methods based on frequency- and time-domain like FDD, pLSCF and SSI were applied. Extracted frequencies and mode shapes from the different identification methods showed a greater consistency for three buildings, however the three lower frequencies extracted were 1.2 to 1.7 times as stiff as those obtained using the initial FE models. Comparing the extracted fundamental periods with those estimated from the code equations and FE analysis, the FE analysis results showed the most flexible behavior, and the most simple equation that considers the building height as the only parameter correlated fairly well with test results. It is recognized that such a discrepancy arises from the fact that the present tests exclude the stiffness decreasing factors like concrete cracking, while the FE models ignore the stiffness increasing factors, such as the contribution of non-structural elements and the actual material properties used.

Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus (EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가)

  • Seo, Jungki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.655-663
    • /
    • 2016
  • Increasing green house gas and it consequent climate change problems are discussed as a global issue. Accordingly, future local green house gas emission will increase up to 40% of the entire local green house gas emission and therefore, efforts to reduce the emission in construction industry is urgently required. Therefore, in this study, heating energy demand was analyzed by using the EnergyPlus simulation according to wood material finishes configuration. EnergyPlus has the entry for a variety of buildings and heating, ventilation, air conditioning (HAVC) system components, in particular buildings, air conditioning systems, and performs simultaneous integrated calculated through the feedback between the heat source unit, a verification program according to the ASHRAE Standard 140-2007 to be. The climate data for the simulation we used the data IWEC in Incheon and Gwangju provided by EnergyPlus. The analysis of simulation model was farm and fishing house standard design drawings: 2012, presented at the Korea Rural Community Corporation. The results of simulation of central region and southern region were effected by wood products of simulation model into the interior finish, exterior finish, windows, wooden structure. Also, it was confirmed that the reduced heating energy demand.

Shrinkage Stress Analysis of Concrete Slab in Multi-Story Building Considering Construction Sequence (시공단계를 고려한 고층건물 콘크리트 슬래브의 건조수축 응력해석)

  • 김한수;정종현;조석희
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.457-465
    • /
    • 2001
  • Shrinkage strains of concrete slab in multi-story building are restrained by structural members such as columns or walls, then can induce cracks due to excessive shrinkage stress over tensile strength of member. In this study, a shrinkage stress analysis method of concrete slab in multi-story building considering not only material properties such as shrinkage, creep and reinforcement effect but also construction sequence is proposed. Tensile stresses of slab due to shrinkage are calculated by converting shrinkage strains into equivalent temperature gradients, creep that can release shrinkage stress can be considered by replacing the modulus of elasticity of concrete, Ec , to the effective secant modulus of elasticity of concrete, E$\_$eff/ Reinforcements are also considered by modeling them as equivalent beam elements in FEM program. Results of step by step analysis reflecting construction sequence summed up to calculate stresses of the whole building considering that shrinkage stresses of the building come from the difference of shrinkage between i-th floor and (i-1)-th floor, named as effecitive shrinkage, and it can be varied by construction sequence. The results of 10-story example building show that shrinkage stresses of lower floors are greater than those of upper floors, that is, stresses of lower floors(1∼2FI.) exceed modulus of rupture of concrete, but stress ratios of higher floors are in the range of 27.9∼92.8%.

A Study on Experimental Analysis of Dynamic properites for Structure and its Application (구조물 동특성의 실험적 해석과 응용기술에 관한 연구 (기계식 주차설비 진동제어))

  • 이홍기;박상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.40-45
    • /
    • 1993
  • 일반적으로 건물 구조물에 전달되는 기계진동을 감소시키기 위해서 기계와 기초사이에 유연한 방진소자를 삽입하여 기계가진력(exciting force)의 전달 률을 줄인다. 또한 구조물의 고유진동수와 진동원의 가진주파수가 일치할 경 우, 가진주파수를 변화시키거나, 구조물의 동특성을 변화시키는 방법을 사용 한다. 어떠한 방안을 선택하든 효과적이고 정량적인 방진 시스템을 구성하고 구조물의 정확한 진동상태를 예측하기 위해서는 진동원의 가진특성과 구조 물의 동특성에 대한 정보가 요구된다. 일반적으로 방진설계를 위해 필요한 진동원의 가진특성은 제조회사의 사양이나 측정을 통하여 비교적 쉽게 얻을 수 있다. 복합재료, 다양한 경계조건, 복잡한 대형구조물등은 수치해석을 이 용하여 해석적인 방법으로 동특성을 구할 경우, 신뢰성 있는 정보를 얻기에 는 많은 노력이 요구된다. 더우기 현장에서 발생하는 진동문제는 대부분 복 잡하고 시간적으로 시급히 해결해야 하기 때문에 효율적인 절차를 구성하여 구조물의 동특성을 해석하는 방법을 사용할 필요가 있다. 구조물의 동특성은 실험적인 방법을 통하여 구하고 그 외의 필요한 계산들은 해석을 통하여 얻 는 것이 효율적일 수 있다. 실험적 동특성해석은 입력하중에 대한 응답의 크 기와 위상 비를 주파수별로 나타내는 전달함수를 측정하는 방법으로서 가진 장치 및 여러 측정/분석 장비가 필요하며, 철교, 교량, 건물의 철골 및 콘크 리트 슬라브등 다양한 중대형의 구조물을 Signal/Noise비가 좋도록 가진 시 켜야 할 필요성이 있다. 본 연구에서는 이러한 실험적 방법의 현장 적응성과 신뢰성을 확보하기 위해 대형충격기(large impact hammer, max, peak force 약 10000N, time duration 약 20ms)를 제작하고 실험/분석 시스템 및 구조물 의 진동제어를 위한 절차를 Fig.1과 같이 구성하고 이를 철근콘크리트 건물 에 설치한 기계식 주차설비의 진동제어에 적용하였다.force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity value. The results shows

  • PDF

Studies on the Uptake of Mineral Nutrients by Ginseng Plant (인삼의 무기 영양 흡수에 관한 연구)

  • Kim, Joon-Ho;Moon, Hyung-Tae;Chae, Myung-In
    • Journal of Ginseng Research
    • /
    • v.2 no.1
    • /
    • pp.35-57
    • /
    • 1977
  • Seasenal absorption of inorganic nutrients and dry matter Production were studied with four-year-old ginseng plant. The residuary amounts of the nutrients supplied to ginseng Plantation were decreased with lime elapsed. The decreasing rate was greater in chemical plots than in Yacto Plots. The amounts of manure applied in this current year and growth in dry matter production of ginseng showed no signficant difference. The amounts of mineral nutrients per unit dry matter were proportional to the amounts of supplied with chemical fertilizer in the early period of growing season but with Yacto in the late season of growing. Seasonal changes of nitrogen, Phosphorus and Potassium contents per unit dry weight in each organ were high in the middle of May. They decreased sharply in the middle of June and then slowly decreased in both leaves and stems but gradually increased in roots. The absorption ratio of nitrogen to Phosphorus (N/P) was high, and that of nitrogen to Potassium (N/K) was few. The amounts of nitrogen, phosphorus and Potassium in leaves became lower with increasing the relative light intensity, but in stems, the concentrations were different with the kind of mineral nutrients. The requisite amounts of mineral nutrient of ginseng plant were 8.3∼9.9 kg of nitrogen, 1.2∼1.5 kg of phosphorus, 6.4∼7.9 kg of potassium Per 10 a for five years.

  • PDF

A Study on the Status of Low-rise Buildings (국내 저층 건축물의 현황에 관한 고찰)

  • Park, Hong-Shin
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.28-28
    • /
    • 2011
  • 국내의 건축물에 관한 통계정보는 국토해양부에 의해서 공표된 통계연보로서 2002년부터 매년마다 제공되고 있다.(국토해양통계누리, https : //stat.mltm.go.kr/potal/stat/yearReport.do) 건축물의 통계연보는 과거부터 2002년까지 매 3년마다 공표된 것으로 알려지고 있다. 이 통계연보에는 건축물 현황과 건축허가착공 통계가 수록되어 있다. 건축물 현황에는 2009년 말을 기준으로 기존 건축물이 전체 6,618,131동으로서 용도별, 층수와 연면적별 그리고 소유구분별 등의 구분에 따라 건축물의 동수에 관한 통계자료가 포함돼 있다. 건축허가 및 착공통계에는 용도별과 구조재료별의 분류에 따라 건축물의 동수에 관한 자료가 신축, 증축 개축 이전 대수선, 용도변경 등으로 분류되어 수록돼 있다. 한편 국내에서 건축물에 대한 내진설계기준이 1988년에 제정됨에 따라 법제화되었다. 이때 내진설계의 의무 대상건축물은 6층 이상 또는 연면적 1만$m^2$이상인 건축물로 규정되었다. 그 이후 내진설계 대상 건축물이 1996년부터 아파트는 5층 이상으로, 판매시설은 연면적 5천$m^2$이상으로 확대되었고, 2000년부터 숙박시설 오피스텔 및 기숙사는 5층 이상으로 확대되었으며, 2005년부터 내진설계 의무화 대상이 3층 이상 또는 1천$m^2$이상으로 확대되었고, 2009년부터 3층 이상 건축물의 구조안전의 확인을 위한 세부절차를 규정하여 내진설계의 실효성을 확보하고 있다. 이와 같이 내진설계의 대상 건축물이 내진설계기준을 제정한 이후 현재까지 시대의 흐름에 따라 6층 이상에서 5층 이상으로 다시 3층 이상으로 계속 확대되어왔다. 이런 환경에서 현재 시점에서 사용 중인 기존 건축물 중에 내진설계가 적용되지 아니한 건축물은 1988년 3월 1일 이전에 건축허가 된 건축물과 그 이후에 건축허가 된 3층 내지 5층 이하인 저층 건축물의 두 가지로 구분할 수 있다. 이들의 내진설계가 미적용 된 건축물에 대해서는 원칙적으로 내진보강 대책 수립 및 추진이 필요한 실정이다. 국내에서는 현재 지진재해대책법에 따라 지진재해로부터 국민의 생명과 재산을 보호하기 위하여 기존 시설물에 대한 내진대책을 추진하는 정책이 시행되고 있다. 앞으로는 이 정책의 일환으로 기존 건축물의 내진성능 확보를 위한 내진보강 대책이 구체적으로 추진될 전망이다. 이와 같이 기존 건축물에 대한 내진보강 대책을 수립하는 데는 무엇보다 그 대상 건축물의 수와 구조형식에 관한 정보가 필요하다. 이는 내진보강의 방법과 소요비용이 건축물의 층수 및 구조형식별 동수에 따라 크게 달라지기 때문이다. 이런 관점에서 살펴볼 때 내진대책의 수립에 필수인 기존 저층 건축물의 층수 및 구조형식별 동수에 관한 통계자료를 현재 건축물의 현황통계에서 손쉽게 찾아 볼 수 있으면 좋겠는데 현실은 그렇지 못한 실정이다. 현재 건축물의 현황통계에는 저층 건축물에 해당하는 층수에 관한 구분이 연대에 따라 다르고 구체적인 층수를 구분하기 어렵게 불분명한 항목으로 구성된 것과 구조형식별 분류항목이 없는 형편이다. 반면에 건축허가 및 착공통계자료에는 구조재료별 건축물 동수와 연면적에 관한 자료가 수록되어있고, 건축물 층수에 따라 분류된 통계자료는 없다. 이 연구에서는, 기존 건축물에 대한 내진보강 대책을 수립하는데 필요한 저층 건축물의 층수 및 구조재료별 동수 등에 관한 구체적인 정보를 파악하기 위하여, 건축물 통계연보에 수록된 건축물 현황통계자료에서 불명확하거나 결여된 정보를 건축허가 및 착공 통계자료로부터 얻은 정보로 보완과 보충하여 제시하고 있다. 따라서 이 연구는 기존 건축물의 내진보강 대책 수립에 필요한 5층 이하의 저층 건축물에 관한 층수별 및 구조형식별 동수에 관한 연도별 통계자료를 추정하여 제안하는데 그 목적이 있다.

  • PDF