• Title/Summary/Keyword: 건물옥상높이

Search Result 11, Processing Time 0.024 seconds

Reduction of Suspended Solids in First Flush from a Building Rooftop using Various Media (여과재를 활용한 건물옥상유출 초기빗물의 부유물질 저감)

  • Kim, Seongbeom;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.214-219
    • /
    • 2017
  • We analyzed the water quality of first flush and rainfall runoff from a building rooftop, and investigated the removal of suspended solids (SS) in first flush using various media to develop a first flush filtration system. Particle size distribution exhibited most of particles in first flush from the rooftop ranged from 10 to 30 ${\mu}m$. SS concentrations maxed in 10~20 min and decreased afterwards. Dissolved organics and inorganic materials in runoff also showed highest levels in first flush (10 min). Filtration tests using anthracite (AC), polyurethane (PU), polypropylene (PP) showed about 50% of SS removal during the first 10 min operation, but the removal rates dramatically decreased after 20 min of filtration. Based upon the results from rinse and run cycle tests, only AC could achieve nice cycles without distinct decease of SS removal. SS removal rates increased with higher depth of media bed and lower flowrate. The system achieved over 50% of SS removal with a media depth of 30 cm and flowrate < 12 L/min.

Automated Extraction of Orthorectified Building Layer from High-Resolution Satellite Images (고해상도 위성영상으로부터 건물 정위 레이어 자동추출)

  • Seunghee Kim;Taejung Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.3
    • /
    • pp.339-353
    • /
    • 2023
  • As the availability of high-resolution satellite imagery increases, improvement of positioning accuracy of satellite images is required. The importance of orthorectified images is also increasing, which removes relief displacement and establishes true localization of man-made structures. In this paper, we performed automated extraction of building rooftops and total building areas within original satellite images using the existing building height database. We relocated the rooftop sin their true position and generated an orthorectified building layer. The extracted total building areas were used to blank out building areas and generate true orthographic non-building layer. A final orthorectified image was provided by overlapping the building layer and non-building layer.We tested the proposed method with KOMPSAT-3 and KOMPSAT-3A satellite images and verified the results by overlapping with a digital topographical map. Test results showed that orthorectified building layers were generated with a position error of 0.4m.Through the proposed method, the feasibility of automated true orthoimage generation within dense urban areas was confirmed.

A Study on the Deformation Characteristics of the Roof Signboard Size in Wind Pressure Formation (풍압 형성에 따른 옥상광고판 크기별 특성에 관한 연구)

  • Hong, Ji-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.401-408
    • /
    • 2019
  • This study numerically examined the maximum wind pressure distribution of a billboard on the roof of a middle-rise building. The deformation caused by the maximum wind pressure was examined. For the numerical analysis, the signboard was assumed to be installed on $(b)20m{\times}(d)10m{\times}(h)$ buildings. The maximum wind pressure was measured using four models with the standard model and different sizes of the signboard. The numerical analysis showed that the horizontal deformation predominantly occurs as the shape of the signboard becomes closer to a rectangle, and high wind pressure and deformation occur at the corners of both ends. As the height of the signboard increases, vertical deformation predominantly occurs, and static pressure forms on the backside. When the height is lower than the width of the signboard, the wind pressure is concentrated on the center of the roof. Therefore, the distribution of the maximum wind pressure is stable, and the effect of the wind pressure is relatively low as the height-to-width ratio approaches 1.

The Parameter for the User's Emotional Safety Test Utilized EKG (EKG를 통한 난간에 대한 심리적 안정감 평가)

  • Lee, Sung-Pil;Jang, Hyung-Wook;Goh, Kyung-Wook
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2007.05a
    • /
    • pp.128-131
    • /
    • 2007
  • 난간의 각 구성요소는 설치장소 및 용도에 따라 여러 설치 관련규정에 의해서 규제되어 있는데 이 규정은 난간의 높이에 대한 규정으로, 이러한 규제된 난간의 요소 중 하나인 난간 높이와 실지 소비자들이 느끼는 심리적 안정성이 일치하는가에 대한 여부는 여전히 의문으로 남아있다. 건물의 옥상에 설치된 난간에 대해서 난간의 높이가 아닌 다른 어떠한 구성요소가 실지로 소비자들에게 조형적 안정감을 주는지에 대한 부분은 연구가 상당히 미흡하다고 생각한다. 본 연구는 부산에 위치한 초등학교를 대상으로 4층 이상의 고층구조물에 설치되어 있는 난간을 범주로 하여 설문조사를 실시하고, 난간이 설치되어 있는 현장에서는 EKG(심전도 테스트)를 시행, 사용자들이 기존에 인지하고 있는 난간에 대한 느낌과 현장에서 실제로 느끼는 조형적 측면의 심리적 안정감 및 다른 요소를 분석하여 사용자가 안정감을 가질 수 있는 난간디자인에 필요한 구성요소를 발견하는 것이 본 연구의 목적이다. 또한 기존에 사용하고 있는 난간 설치의 규정의 정당성 여부를 고찰 및 재조명하여 사용자의 심리적 안정성을 충족시키는 가에 대한 자료 제시를 목적으로 한다.

  • PDF

Performance Evaluation for the Application of Roof Green Box Unit System Combined with Engineering P.E.Waterproof and Root Penetration Sheet (엔지니어링 PE방수.방근시트가 결합된 박스 유닛형 옥상 녹화 시스템 적용을 위한 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.125-131
    • /
    • 2016
  • According to the increment of urban buildings, the demand of eco-environment space will be also increased. Therefore, the artificial ground green system on a roof will be supplied gradually. In this study, the concept of simplification, unification and prefabrication was widely applied to supply green system. Consequently, the box unit system with a continuous soil layer was developed, and adhesive property, wind resistance and insulation property of this system were evaluated for site application. As a results of adhesive property and wind resistance test, comparing with design wind pressure and wind velocity, this system was safe at the height of 100m building located in urban. In addition, results of temperature measurement for 120 days showed 17% higher insulation property at daytime and 45% higher insulation property at night than normal box unit system owing to continuous soil layer.

Heat Budget Analysis of Light Thin Layer Green Roof Planted with Zoysia japonica (한국잔디식재 경량박층형 옥상녹화의 열수지 해석)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.190-197
    • /
    • 2012
  • The purpose of this study was to evaluate thermal environment and heat budget of light thin layer green roof through an experiment in order to quantify its heat budget. Two concrete model boxes($1.2m(W){\times}1.2m(D){\times}1.0m(H)$) were constructed: One experiment box with Zoysia japonica planted on substrate depth of 10cm and one control box without any plant. Between June 6th and 7th, 2012, outside climatic conditions(air temperature, relative humidity, wind direction, wind speed), evapotranspiration, surface and ceiling temperature, heat flux, and heat budget of the boxes were measured. Daily maximum temperature of those two days was $29.4^{\circ}C$ and $30^{\circ}C$, and daily evapotranspiration was $2,686.1g/m^2$ and $3,312.8g/m^2$, respectively. It was found that evapotranspiration increased as the quantity of solar radiation increased. A surface and ceiling temperature of those two boxes was compared when outside air temperature was the greatest. and control box showed a greater temperature in both cases. Thus it was found that green roof was effective in reducing temperature. As results of heat budget analysis, heat budget of a green roof showed a greater proportion of net radiation and latent heat while heat budget of the control box showed a greater proportion of sensible heat and conduction heat. The significance of this study was to analyze heat budget of green roof temperature reduction. As substrate depth and types, species and seasonal changes may have influences on temperature reduction of green roof, further study is necessary.

Analysis of Urban Heat Island Effect Using Information from 3-Dimensional City Model (3DCM) (3차원 도시공간정보를 이용한 도시열섬현상의 분석)

  • Chun, Bun-Seok;Kim, Hag-Yeol
    • Spatial Information Research
    • /
    • v.18 no.4
    • /
    • pp.1-11
    • /
    • 2010
  • Unlike the previous studies which have focused on 2-dimensional urban characteristics, this paper presents statistical models explaining urban heat island(UHI) effect by 3-dimensional urban morphologic information and addresses its policy implications. 3~dimensional informations of Columbus, Ohio arc captured from LiDAR data and building boundary informations are extracted from a building digital map, Finally NDV[ and temperature data are calculated by manipulating band 3, band 4, and thermal hand of LandSat images. Through complicated data processing, 6 independent variables(building surface area, building volume, height to width ratio, porosity, plan surface area) are introduced in simple and multiple linear regression models. The regression models are specified by Box-Tidwell method, finding the power to which the independent variable needs to raised to be in a linearity. Porosity, NDVI, and building surface area are carefully chosen as explanatory variables in the final multiple regression model, which explaining about 57% of the variability in temperatures. On reducing UHI, various implications of the results give guidelines to policy-making in open space, roof garden, and vertical garden management.

Electromagnetic Wave in all Base Stations (다기지국 환경에서 전자파 노출량)

  • Cho, Euy-Hyun;Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.26-44
    • /
    • 2011
  • The Study was carreid out to see whether the intensity of electromagnetic waves in each floor of a building where the sharing base station has been established is harmful to a human body, and to expect the intensity of the waves in the building. The investigate was performed on both of sharing base station either with many scatterers or without any of them. To satisfy the international standard and the domestic TTA standard, rms for each of the electromagnetic wave of every floor in the building with the station was measured from 3 location of 3 heights(1.1m,1.5m, and 1.7m). Max of the measured rsm from the each of the frequencies in the nine location was confirmed to be 48.12%(the rooftop measured value) at most, compared to the human body protection standard. The value was confirmed to satisfy the human body protection standard for each frequency. And the total value of the calculated exposure indexes for each frequency was determined to be more than 7 times lower at most, which was 0.1445, compared to the 1 standard. Since P value in both of 868MHz and 2.14GHz electromagnetic waves intensity for each base station and floor was less than 0.05, it was revealed to be meaningful, and since R-Sq(adj) value showed a value more than 50%, the regression equation was determined to fully absorb the data information. However, although the P value of both of 868MHz and 2.14GHz electromagnetic waves intensities under the integrating terms of the base station data and the floor data was showed to be less than 0,05, since R-Sq(adj) value of 868MHz electromagnetic waves intensity presented a value smaller than 50%(34.15%), it was determined that the 868MHz electromagnetic waves intensity is very much influenced by an environment with a base station. Because the electromagnetic waves intensity of 2.14GHz show R-Sq(adj) value bigger then 50%(51.8%), The regression equation model of 2.14GHz electromagnetic waves intensity was confirmed to be proper. It also turned out not to be effected by the surrounding environment near a building with the base station and the intensity of electromagnetic waves for each floor of such building was expectable by the regression equation.

The Examination of the Validity of a Vertically Upward Shifting of the Landscape Control Point(LCP) for the Management of Cities Mountain Landscape (시가지내 산악경관관리를 위한 조망점의 수직상향 동의 검증)

  • 정정섭;권상준;조태동
    • Korean Journal of Environment and Ecology
    • /
    • v.17 no.4
    • /
    • pp.366-374
    • /
    • 2004
  • The purpose of this study is to develop effective destination management strategies for three typical tourist destinations in Kangwon province based on the importance-performance analysis. The results show that overall performance levels of 21 management attributes in three destinations is relatively low, compared to the importance levels of the attributes. 6 attributes place in Concentrate Here, 4 attributes in Possible Overkill, 6 attributes in Keep Up Good Work, and 5 attributes in Low Priority. There is no significant difference in the importance level among three destinations, while performance levels are the lowest at Naksan & Kyungpo beaches, and highest at Ganhyun area. Findings of the survey expect to be used as fundamentals in management policy making process for each destinations.

Accuracy Assessment of Aerial Triangulation of Network RTK UAV (네트워크 RTK 무인기의 항공삼각측량 정확도 평가)

  • Han, Soohee;Hong, Chang-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.663-670
    • /
    • 2020
  • In the present study, we assessed the accuracy of aerial triangulation using a UAV (Unmanned Aerial Vehicle) capable of network RTK (Real-Time Kinematic) survey in a disaster situation that may occur in a semi-urban area mixed with buildings. For a reliable survey of check points, they were installed on the roofs of buildings, and static GNSS (Global Navigation Satellite System) survey was conducted for more than four hours. For objective accuracy assessment, coded aerial targets were installed on the check points to be automatically recognized by software. At the instance of image acquisition, the 3D coordinates of the UAV camera were measured using VRS (Virtual Reference Station) method, as a kind of network RTK survey, and the 3-axial angles were achieved using IMU (Inertial Measurement Unit) and gimbal rotation measurement. As a result of estimation and update of the interior and exterior orientation parameters using Agisoft Metashape, the 3D RMSE (Root Mean Square Error) of aerial triangulation ranged from 0.153 m to 0.102 m according to the combination of the image overlap and the angle of the image acquisition. To get higher aerial triangulation accuracy, it was proved to be effective to incorporate oblique images, though it is common to increase the overlap of vertical images. Therefore, to conduct a UAV mapping in an urgent disaster site, it is necessary to acquire oblique images together rather than improving image overlap.