• Title/Summary/Keyword: 건물에너지 모델

Search Result 128, Processing Time 0.03 seconds

Landscape Planning and Design Methods with Human Thermal Sensation (인간 열환경 지수(HumanThermal Sensation)를 이용한 조경계획 및 디자인 방법)

  • Park, Soo-Kuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • Human thermal sensation based on a human energy balance model was analyzed in the study areas, the Changwon and Nanaimo sites, on clear days during thesummer of 2009. The climatic input data were air temperature, relative humidity, wind speed and solar and terrestrial radiation. The most effective factors for human thermal sensation were direct beam solar radiation, building view factor and wind speed. Shaded locations had much lower thermal sensation, slightly warm, than sunny locations, very hot. Also, narrow streets in the Nanaimo site had higher thermal sensation than open spaces because of greater reflected solar radiation and terrestrial radiation from their surrounding buildings. Calm wind speed also produced much higher thermal sensation, which reduced sensible and latent heat loss from the human body. By adopting climatic factors into landscape architecture, the human thermal sensation analysis method promises to help create thermally comfortable outdoor areas. The method can also be used for urban heat island modification and climate change studies.

Inelastic Dynamic Demands of a RC Special Moment Frame Building (철근 콘크리트 특수 모멘트 골조 건물의 비탄성 동적 요구값)

  • Kim, Tae-Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.11-19
    • /
    • 2005
  • Seismic design of a building is usually performed by using the linear static procedure. However, the actual behavior of the building subjected to earthquake is inelastic and dynamic in nature. Therefore, inelastic dynamic analysis is required to evaluate the safety of the structure designed by the current design codes. For the validation, a RC special moment resisting frame building was chosen and designed by IBC 2003 representing new codes. Maximum plastic rotation and dissipated energy of some selected members were calculated for examining if the inelastic behavior of the building follows the intention of the code, and drift demand were calculated as well for checking if the building well satisfies the design drift limit. In addition, the effect of including internal moment resisting frames (non lateral resisting system) on analyses results was investigated. As a result of this study, the building designed by IBC 2003 showed the inelastic behavior intended in the code and satisfied the design drift limit. Furthermore, the internal moment resisting frames should be included in the analytical model as they affect the results of seismic analyses significantly.

Inelastic Analysis of Steel Frame Structures with Viscoelastic Damper (점탄성 감쇠기가 설치된 철골조 건물의 비탄성 해석)

  • 김진구;최현훈
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.2
    • /
    • pp.271-278
    • /
    • 2000
  • In this study the effect and applicability of viscoelastic dampers on the seismic reinforcement of steel framed structures are investigated in the context of the performance based design approach. The effect of the damper on dissipating the input seismic energy was investigated with a single degree of freedom system. For analysis models a five-story steel frame subjected to gravity load, a ten-story and twenty-story structure subjected to gravity and wind load were designed. The code-specified design spectrums were constructed for each soil type and performance objective, and artificial ground excitation records to be used in the nonlinear time history analysis were generated based on the design spectrums. Inter-story drift was adopted as the primary performance criterion. According to the analysis results, all model structures turned out to satisfy the performance level for most of the soil conditions except for the soft soil(operational level). It was also found that the seismic performance could be greatly enhanced, and the structures were led to behave elastically by installing viscoelastic dampers on appropriate locations.

  • PDF

Assessment of the MELCOR 1.8.6 condensation heat transfer model under the presence of noncondensable gases (중대사고 해석코드 MELCOR 1.8.6의 비응축성기체 존재 시 응축열전달 모델 평가)

  • Yoo, Ji Min;Lee, Dong Hun;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.1-20
    • /
    • 2016
  • A condensation heat transfer model is very important for the safety analysis of nuclear power plants. Especially, condensation under the presence of noncondensable gases (NCGs) is an important issue in nuclear safety because the presence of even a small quantity of NCGs in the vapor largely reduces the condensation rate. In this study, the condensation heat transfer model of the severe accident analysis code MELCOR 1.8.6 has been assessed using a set of condensation experiments performed under the thermal-hydraulic conditions similar to those inside a containment during design-basis accidents or severe accidents. Experiment conditions are categorized into 4 types according to the shape of the condensation surface: vertical flat plates, outer surface of vertical pipes, inner surface of vertical pipes, the inner surface of horizontal pipes. The results of the calculations show that the MELCOR code generally under-predicts the condensation heat transfer except the condensation on inner surface of vertical pipes.

Investigating the Use of Energy Performance Indicators in Korean Industry Sector (한국 산업부문의 에너지성과 지표 이용에 관한 연구)

  • Shim, Hong-Souk;Lee, Sung-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.707-725
    • /
    • 2021
  • Energy management systems (EnMS) contribute to sustainable energy saving and greenhouse gas reduction by emphasizing the role of energy management in production-oriented economies. Although understanding the methods used to measure energy performance is a key factor in constructing successful EnMS, few attempts have been made to examine these methods, their applicability, and their utility in practice. To fill this research gap, this study aimed to deepen the understanding of energy performance measures by focusing on four energy performance indicators (EnPIs) proposed by ISO 50006, namely the measured energy value, ratio between measured values, linear regression model, and nonlinear regression model. This paper presents policy and managerial implications to facilitate the effective use of these measures. An analytic hierarchy process (AHP) analysis was conducted with 41 experts to analyze the preference for EnPIs and their key selection criteria by the industry sector, and organization and user type. The findings suggest that the most preferred EnPI is the ratio between the measured values followed by the measured energy value. The ease of use was considered to be most important while choosing EnPIs.

Energy Retrofit and Estimate for Small-to-Medium Office Buildings (중소규모 사무소건물의 에너지 개보수 방안 및 평가)

  • 정영선;허정호;방기영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.279-288
    • /
    • 2001
  • This paper is to derive energy retrofit strategies through energy audit and analysis for a selected small-to-medium office building located in Seoul, Korea,. To activate ESCO business in Korea, our final goal is to develope a simple and adequate energy retrofit procedure through computer simulation. Calibration process was fairly successful eve without the aid of tough field measurement. In terms of annual energy consumption, the percent difference between the predicted and the monitored values were within a reasonable tolerance of $\pm10$%. Based on the calibrated baseline model and the systematic investigation of target building, retrofit measures were suggested with two categories such as architectural side and equipment side. Both selected parametric and interactive retrofit measure simulations resulted in various energy saving quantities and cost, thus the priority among the measures were made. If we were to select the more realistic and reasonable retrofit measure in future, economic estimate were should be practiced with the life cycle cost analysis.

  • PDF

Development of Summer Leaf Vegetable Crop Energy Model for Rooftop Greenhouse (옥상온실에서의 여름철 엽채류 작물에너지 교환 모델 개발)

  • Cho, Jeong-Hwa;Lee, In-Bok;Lee, Sang-Yeon;Kim, Jun-Gyu;Decano, Cristina;Choi, Young-Bae;Lee, Min-Hyung;Jeong, Hyo-Hyeog;Jeong, Deuk-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.246-254
    • /
    • 2022
  • Domestic facility agriculture grows rapidly, such as modernization and large-scale. And the production scale increases significantly compared to the area, accounting for about 60% of the total agricultural production. Greenhouses require energy input to create an appropriate environment for stable mass production throughout the year, but the energy load per unit area is large because of low insulation properties. Through the rooftop greenhouse, one of the types of urban agriculture, energy that is not discarded or utilized in the building can be used in the rooftop greenhouse. And the cooling and heating load of the building can be reduced through optimal greenhouse operation. Dynamic energy analysis for various environmental conditions should be preceded for efficient operation of rooftop greenhouses, and about 40% of the solar energy introduced in the greenhouse is energy exchange for crops, so it should be considered essential. A major analysis is needed for each sensible heat and latent heat load by leaf surface temperature and evapotranspiration, dominant in energy flow. Therefore, an experiment was conducted in a rooftop greenhouse located at the Korea Institute of Machinery and Materials to analyze the energy exchange according to the growth stage of crops. A micro-meteorological and nutrient solution environment and growth survey were conducted around the crops. Finally, a regression model of leaf temperature and evapotranspiration according to the growth stage of leafy vegetables was developed, and using this, the dynamic energy model of the rooftop greenhouse considering heat transfer between crops and the surrounding air can be analyzed.

Artificial Neural Network Models for Optimal Start and Stop of Chiller and AHU (인공신경망 모델을 이용한 냉동기 및 공조기 최적 기동/정지 제어)

  • Park, SungHo;Ahn, Ki Uhn;Hwang, Aaron;Choi, Sunkyu;Park, Cheol Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.2
    • /
    • pp.45-52
    • /
    • 2019
  • BEMS(Building Energy Management Systems) have been applied to office buildings and collect relevant building energy data, e.g. temperatures, mass flow rates and energy consumptions of building mechanical systems and indoor spaces. The aforementioned measured data can be beneficially utilized for developing data-driven machine learning models which can be then used as part of MPC(Model Predictive Control) and/or optimal control strategies. In this study, the authors developed ANN(Artificial Neural Network) models of an AHU (Air Handling Unit) and a chiller for a real-life office building using BEMS data. Based on the ANN models, the authors developed optimal control strategies, e.g. daily operation schedule with regard to optimal start and stop of the AHU and the chiller (500 RT). It was found that due to the optimal start and stop of the AHU and the chiller, 4.5% and 16.4% of operation hours of the AHU and the chiller could be saved, compared to an existing operation.

Experimental Investigation of Steam Condensation Heat Transfer in the Presence of Noncondensable Gas on a Vertical Tube (수직 튜브 외벽에서의 증기-비응축성 기체 응축 열전달 실험 연구)

  • Lee, Yeon-Gun;Jang, Yeong-Jun;Choi, Dong-Jae;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.42-50
    • /
    • 2015
  • To evaluate the heat removal capability of a condenser tube in the PCCS of an advanced nuclear power plant, a steam condensation experiment in the presence of noncondensable gas on a vertical tube is performed. The average heat transfer coefficient is measured on a vertical tube of 40 mm in O.D. and 1.0 m in length. The experiments covers the pressures of 2-4 bar, and the mass fraction of air ranges from 0.1 up to 0.7. From the experimental results, the effects of the total pressure and the concentration of air on the condensation heat transfer coefficient are investigated. The measured data are compared with the predictions by Uchida's and Tagami's correlations, and it is revealed that these models underestimate the condensation heat transfer coefficient of the steam-air mixture.

Design and Construction of Urban-type Energy Self-Supporting Smart-Farm Service Model (도심형 에너지 자립 스마트팜 서비스 모델 설계 및 구축)

  • Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1305-1310
    • /
    • 2019
  • Modern agriculture is changing from resource-oriented agriculture to technology-oriented agriculture. Agriculture, which combines science and technology, is recognized as a new growth engine, and governments, local governments, research institutes, and industry are working together to develop and disseminate various devices necessary for smart farms to build intelligent smart farms. Recently, research is being conducted to build a more intelligent agricultural environment by building a cloud platform. In this paper, we propose a plan to build an urban energy - independent smart farm that can utilize leisure time and agricultural activities by utilizing the rooftop of a city. Also, by using IT technology, various data of smart farm can be managed on remote server, and HMI module for controlling internal environment of smart farm can be developed to manage smart farm automatically or semi-automatically. The service model suggests a model that can manage the internal environment of the smart farm based on mobile.