• Title/Summary/Keyword: 건물성능평가

Search Result 539, Processing Time 0.028 seconds

Design of Lateral Load Resisting System using Nonlinear Static Analysis (비선형 정적해석을 통한 횡저항 시스템의 보유성능 평가 및 설계방안 연구)

  • Song, Jin-Gyu;Kim, Geon-Woo;Jung, Sung-Jin;Song, Young-Hoon;Lee, Seung-Chang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.1 s.47
    • /
    • pp.9-16
    • /
    • 2006
  • The design practice of the lateral resisting system has been traditionally dependent on the experience and know-how of a structural engineer. And the method to reflect the evaluation results of building's capacity on design process doesn't exist. The proposal of a rational design of the lateral load resisting system is based on the available full capacity $(R_{ac})$ of a building and the minimum required capacity $(R_{code})$ suggested in the code. This study suggests thai nonlinear static analysis, which is the estimation of the lateral capacity with the pushover analysis, be included in the existing design procedure of the structure. After finishing the basic structural design, the lateral resisting capacity ol a building is estimated. At the phase of nonlinear static analysis, pushover analysis is peformed to define the fully yielded baseshear $(V_Y)$. When the design wind baseshear $(V_{wind})$ is bigger than the design seismic baseshear $(V_D)$, the value is checked to determine whether or not it is smaller than the $V_Y$. After confirming that it is smaller, the $R_{ac}$ of the structure is computed. If the $V_D$ is bigger at first, only the $R_{ac}$ is computed. When the value of the estimation shows remarkable differences with the $R_{code}$, repetition of the design modification is needed for those approximate to the $R_{code}$. Application of the proposed design procedure to 2-D steel braced RC buildings has proven to be efficient.

배관 세척장치의 성능평가

  • 조정식
    • 월간 기계설비
    • /
    • s.119
    • /
    • pp.71-83
    • /
    • 2000
  • 점차 복잡해지고 있는 사회적 욕구를 만족시키기 위한 건물에서는 반드시 복잡한 설비가 요구되고 있고, 이러한 설비시스템 중에는 급수, 급탕 및 배수설비라고 하는 배관시스템이 없다면 기능유지에 막대한 지장을 초래할 것은 자명하다고 하겠다. 이러한 배관시스템에서는 항시 또는 일부 사용되어질 물이나 사용된 물이 흐르기 때문에 배관내부에 발생하는 스케일(scale)이나 슬라임(slime) 등은 피할 수 없는 사실인 것이다. 건축물 내에 설치된 각종 배관은 건물의 기능을 유지하고 보건위생과 직결되는 중요한 기능을 담당하고 있어 세척의 필요성이 매우 높음에도 불구하고 배관의 수명이 다할 때까지 거의 세척이 이루어지지 않고 사용되어 왔다. 이들 배관에 대한 세척은 배관의 수명연장과 관마찰 계수를 낮추어 급수의 수송동력을 절감할 수 있고, 난방관의 열전달 효과를 높여 에너지 절약 효과를 거두어 건물의 유지관리 비용 절감에 기여할 수 있음에도 적절한 세척공법이 개발되지 않고 있다. 이러한 관점에 맞추어 건물배관의 특성에 맞도록 고압 세척장치를 개발하고 이를 이용한 세척공법을 적용하고자 하였다. 즉, 배관 내에 압축공기를 주기적으로 분사하여 맥동현상이 일어나도록 하면서 기포를 발생시켜 기포가 관의 내벽에서 성장하여 파괴될 때 관내에 부착된 이물질을 제거할 수 있고, 또한 세척효과를 높이기 위하여 관의 벽면에 접촉하면서 배출되는 과정에서 이물질을 제거할 수 있도록 구조와 아울러 이들 장치를 이용한 세척방법의 적용성에 대해서 고찰하고자 한다.

  • PDF

A Study on the Prediction of Residual Strength of Concrete Filled Steel Tube Column without Fire Protective Coating by Unstressed Heating (비재하 가열에 의한 무내화피복 CFT 기둥의 잔존내력 예측에 관한 연구)

  • Kim, Gyu-Yong;Lee, Hyoung-Jun;Lee, Tae-Gyu;Kim, Young-Sun;Kang, Sun-Jong
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.31-39
    • /
    • 2009
  • Recently, fire resistance in high-rise building is becoming major problem socially. So it is need of hour to study on fire resistance in buildings. This study estimates fire resistance performance to utilized CFT (Concrete filled steel tube, below CFT) column in the high structure. But it is difficult quantitative evaluation about fire resistant performance of CFT. Therefore, this study made CFT specimen that determine the factor which is strength of concrete and then CFT column was exposed to heating controlled as closely as possible the ISO-834 standard fire curve. Also, tried to analyze internal temperature through nonlinear transient heat flow analysis. And, presumed extant compressive strength on the basis of this.

A Study on Evaluating the Fire Safety of the Regulation of Escape and Fire-Prevention from Enacting to Now - Focusing on the Hotel Building - (우리나라 피난방화규정의 제.개정시기별 화재안전성능 평가 - 호텔건물을 중심으로 -)

  • Lee, Se-Myong;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.28-41
    • /
    • 2011
  • Regulation of Escape and fire-prevention of Building of South Korea were enacted as a part of building codes in 1962. Since it was enacted, the law has gone through many changes. In this study, evaluated the fire safety of the law about the case of a hotel that the fire risk are expected to be higher whenever it was changed. As a result, the current law has gotten better in tire safety since it was enacted. However, especially it could be confirmed that the evacuation safety is insufficient in the lower level of hotel building. In the case of accommodation, because the occupants become aware of fire lately, they have not enough time to escape. Therefore, this study suggests that it is needed to come up with an effective counterplan about the interior finish materials, fire door and fire compartments that the smoke layer descending time is longer.

Evaluation on the Deformation Capacity of RC Frame Structure with Strong Column-Weak Beam (강한 기둥-약한 보로 설계된 철근 콘크리트 골조구조의 변형성능 평가에 관한 연구)

  • Seo, Soo-Yeon;Lee, Li-Hyung;Chin, Se-Ok;Choi, Yun-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.225-233
    • /
    • 2003
  • Recently, the concern for displacement-based design has been increased as a performance based design method in which the deformation capacity of structure becomes so important. In this paper, a process is presented to accurately evaluate the deformation capacity of multistory RC frame structure. In the calculation of drift of frame, the deformation of beam and column as well as the deformation of anchorage and joint are considered. From the comparison between previous test and calculation results, the usefulness of the process is verified. The proposed process is also applied to the multiple story RC frame buildings(5, 10, 15 stories) designed to have strong column-weak beam. The results showed that the deformation capacity of the buildings could be not properly evaluated when deformations of anchorage and joint were ignored.

A Study on Connection of Fuel Processor and NG blower for Small Commercial Fuel Cell System (건물용 연료전지 시스템용 연료처리장치와 연료승압 블로워 연계 특성에 관한 연구)

  • Kim, Jaedong;Jang, Sejin;Kim, Bonggyu;Kim, Jinwook;Han, Sienho;Park, Dalryung
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.36-44
    • /
    • 2017
  • The small commercial fuel cell is a new energy system that produces electricity and heat through electrochemical reaction between air and hydrogen. In Korea, hundreds of domestic small commercial fuel cell systems have been installed and operated every years and many parts in fuel cell systems depend on overseas products. KOGAS(Korea Gas Corporation) has developed the fuel processor which is an important part of fuel cell system and has evaluated the long-term durability. And KOGAS has evaluated domestic and overseas NG blower and fuel processor connected to NG blower. The fuel processor developed by KOGAS have maintained an efficiency of 76% and constant performance over 3,000 hours. The NG blower developed in Korea showed similar characteristics as overseas NG blower in the evaluation of power consumption according to rear pressure and outside temperature. The fuel processor module, fuel processor connected to BOP showed excellent performance.

Applicability of the Hysteretic Steel Dampers to the Shear-wall Dominant Apartment Buildings (벽식구조 아파트건물의 강재이력형 댐퍼 적용성 평가)

  • Chun, Young-Soo;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.3 no.4
    • /
    • pp.407-413
    • /
    • 2012
  • In this study, the possibility of applying the damping devices to shear-wall dominant apartment buildings(SDA) was examined. In order to achieve research objectives, ASCE/SEI 7-10 design procedure for structures with damping systems applied to four representative apartment buildings which are under design or previously designed with the shear-wall dominant system, and the performances of damping devices were investigated. It is shown that in order to secure the seismic performance of SDA by using dampers, the stiffness of the dampers should be very large because of the effects of shear walls with the high elastic stiffness. But since this large stiffness is highly difficult to implement in reality, prudent decisions have to be made in designing the SDA with damping system and friction dampers with the high initial stiffness are more effective than hysteretic steel dampers.

디퓨저 배치방식에 따른 작업공간내의 환기성능 평가

  • 한화택
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.3
    • /
    • pp.17-23
    • /
    • 2000
  • 개방형 사무실 건물에서, 총 환기량이 적정할지라도 국부적으로 환기가 부족하거나 또는 과다한 작업공간들이 존재할 수 있다. 이것은 환기시스템을 설계할 때 작업공간의 배치와 관련된 정보를 활용하지 않기 때문이다. 모든 작업공간이 충분히 환기될 수 있도록 하기 위해서는 급기구나 배기구 그릴의 형태나 배치선정 등과 같은 다 양한 설계변수들이 작업공간의 HVAC 시스템의 성능에 미치는 영향을 파악하여야 한다. 본 원고는 최근 수행된 작업공간의 환기 성능에 관한 연구결과를 요약한 것이다.

  • PDF

Examination of Method of an Aircraft Noise Reduction -Mainly the Window Installation Conditions- (항공기소음 저감방안에 대한 검토 -창호설치조건을 중심으로-)

  • Yang, Jae-Hoon;Kim, Kyoung-Woo;Yang, Kwan-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.260-263
    • /
    • 2008
  • 공항에 인접한 주거지역에서 항공기 소음문제로 인하여 거주자들에게 소음피해가 발생하고 있다. 이러한 항공기소음을 저감하기 위한 방법 중 건물외피를 차음성능이 높은 구조로 변경하여 건축물의 차음량을 개선시키는 수음원 대책이 일반적으로 사용되고 있다. 특히 건축물 방음시설 설치는 건물외피 중 외부소음에 가장 취약한 창호의 차음량을 증가시키는 것이 효과적인데, 본 연구에서는 기존 창호에 비하여 차음성능이 높은 창호를 교체 설치하여 건축물의 차음량 개선치를 $L_{max}$, SEL, $L_{eq}$로 각각 검토 비교함과 동시에 창호의 기밀성능을 위한 기밀재 및 추가 모헤어의 설치조건에 따른 차음성능을 검토해 보았다. 측정결과 방음시설 설치 후 항공기소음을 $L_{max}$, SEL, $L_{eq}$로 차음량 개선치를 각각 평가한 결과 1.8dB 이내의 편차를 갖는 것으로 나타났으며, 창의 차음성능 개선치는 기밀재 설치 후 $R'45^{\circ}$,w가 5dB, 기밀재 및 추가 모헤어 설치 후 8dB로 나타났다.

  • PDF

Seismic Performance of Low-rise Piloti RC Buildings with Eccentric Core (편심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능)

  • Kim, Sung-Yong;Kim, Kyung-Nam;Yoon, Tae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.490-498
    • /
    • 2020
  • In this study, the seismic performance of low-rise piloti buildings with eccentric core (shear wall) positions was analyzed and reviewed. A prototype was selected among constructed low-rise piloti buildings with eccentric cores designed based on KBC2005. The seismic performance of the building showed plastic behavior in the X-direction and elastic behavior in the Y-direction. The inter-story drift is larger than that of a concentric core case and has the maximum allowed drift ratio. The displacement ratio of the first story is much larger than that of upper stories, and the frame structure in the first story is vulnerable to lateral force. Therefore, low-rise piloti buildings with eccentric cores need to have less lateral displacement, as well as reinforcement of the lateral resistance capacity in seismic design and seismic retrofit.