• Title/Summary/Keyword: 개인 보호 장비

Search Result 121, Processing Time 0.023 seconds

Effect of Mask Wearing and Type on Cardiopulmonary Resuscitation Accuracy, Fatigue and Physiological Changes

  • Sung-Hwan Bang;Hyo-Suk Song;Gyu-Sik Shim;Hee-Jeong Ahn
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.113-120
    • /
    • 2023
  • The purpose of this study was the accuracy of cardiac compression, fatigue, and physiological changes of the rescuer for different mask type in cardiopulmonary resuscitation(CPR). Data collection was from 9 to 12 May 2022, the participants were a total of 24 paramedic students with a BLS provider at D University. The students participated in an experiment in which 12 students each wore a surgical mask (Dental mask) and a fine particle 94% blocking mask (KF94 mask) and performed CPR for 2 minutes over a total of 7 times. As a result of the study, in the analysis of the quality of the rescuer's chest compression according to the type of mask, there was a significant difference in the compression speed (F=24.91, p<.001) and bad compression hand position (F=14.54, p=.024) in the group wearing the KF94, Fatigue showed significant differences in both the Dental mask group (F=51.16, p<.001) and the KF94 mask group (F=63.49, p<.001). Among the physiological changes, heart rate showed a significant difference between the Dental mask group (F=34.79, p<.001) and the KF94 mask group (F=35.55, p<.001), and the respiratory rate showed a significant difference between the Dental mask group (F=25.02, p=.001) and the KF94 mask group(F=23.02, p=.002). Therefore, in order to improve the quality of efficient chest compression and reduce the fatigue and physiological changes of rescuers, it will be necessary for rescuers to wear suitable personal protective equipment.

119 Emergency Medical Technicians' Infection Control Education Status, Stress, and Needs related to Emerging Infectious Diseases

  • Dong-Min Shin;Byung-Jun Cho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.12
    • /
    • pp.201-209
    • /
    • 2023
  • This study investigated to provide basic data for infection control education on new infectious diseases by confirming the level of knowledge, training status, stress, and need for training on new infectious diseases for 119 emergency medical technicians (EMT). This data collection period was a total of 39 days from August 10 to September 18, 2022, and a total of 105 copies were collected. The analysis of this study used the SPSS 25.0 program. As a result of the study, among the 119 paramedics, the gender of the EMT was 54 men (51.4%) and 51 women (48.6%), with more men than women, with 47 people in their 20s (44.8%) and those in their 30s or older. There were 58 people (55.2%), most of whom were in their 30s or older. The highest total work experience was 3 to 5 years (37 people (35.2%)). In the pandemic situation, an attempt was made to check the education status of 119 paramedics on COVID-19 and the need for education on new infectious diseases. As a result of the study, the status of education on COVID-19 was insufficient. The demand for education on new infectious diseases was found to be high. Among 119 emergency responders who are frequently exposed to new infectious diseases, theoretical and practical training in personal protective equipment, stress, including theoretical training, is needed. A theoretical and practical education program on new infectious diseases and personal protective equipment should be developed as a subject for college students before becoming EMT.

Efficient Coverage Guided IoT Firmware Fuzzing Technique Using Combined Emulation (복합 에뮬레이션을 이용한 효율적인 커버리지 가이드 IoT 펌웨어 퍼징 기법)

  • Kim, Hyun-Wook;Kim, Ju-Hwan;Yun, Joobeom
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.5
    • /
    • pp.847-857
    • /
    • 2020
  • As IoT equipment is commercialized, Bluetooth or wireless networks will be built into general living devices such as IP cameras, door locks, cars and TVs. Security for IoT equipment is becoming more important because IoT equipment shares a lot of information through the network and collects personal information and operates the system. In addition, web-based attacks and application attacks currently account for a significant portion of cyber threats, and security experts are analyzing the vulnerabilities of cyber attacks through manual analysis to secure them. However, since it is virtually impossible to analyze vulnerabilities with only manual analysis, researchers studying system security are currently working on automated vulnerability detection systems, and Firm-AFL, published recently in USENIX, proposed a system by conducting a study on fuzzing processing speed and efficiency using a coverage-based fuzzer. However, the existing tools were focused on the fuzzing processing speed of the firmware, and as a result, they did not find any vulnerability in various paths. In this paper, we propose IoTFirmFuzz, which finds more paths, resolves constraints, and discovers more crashes by strengthening the mutation process to find vulnerabilities in various paths not found in existing tools.

A Study on the Improvement of Emergency Safety System as Social Protection System - Focusing on Alone Elderly and Severely Person with Disabilities - (사회적 보호체계로서의 응급안전시스템에 대한 개선방안 연구 -독거노인·중증장애인을 중심으로-)

  • Heo, Soo Kyung;Lim, Soo Jeong;Jeong, Jong Hwa
    • 재활복지
    • /
    • v.20 no.4
    • /
    • pp.31-54
    • /
    • 2016
  • The purpose of this study is to explore the improvement method of the emergency safety system as a social protection scheme for the elderly living alone with severe disabilities. The study was conducted by randomly choosing three regions in the metropolitan area (Jongno-gu, Seoul), the small-medium city (Yongin-si, Gyeonggi-do) and the rural area (Geochang-gun, Gyeongsangnam-do) among 17 cities and counties nationwide. The study method is based on the interview form of the structured questionnaires with city officials, county officials, and center operators. According to the results of the interview analysis, it was recognized that there was a need for an emergency safety system for the elderly living alone with severe disabilities. In spite of this necessity, there were problems about publicity for the discovery of victims of the blind spot in welfare, about inconvenience due to frequent malfunctions of the emergency equipment, about insufficient awareness of the security of the emergency officials and about supply and demand of manpower for 24-hour monitoring service. In order to improve the effective operation of the emergency safety system, it was the most urgent issue to formulate the legislation for responding to the crisis management of the vulnerable. A suggestion of this study is to build a safety system in which one-stop service is provided for the realization of compact welfare through the establishment of a MOU for linkage with community organizations, the full inspection of emergency equipment to solve safety equipment malfunction problems and the manpower supplement for 24-hour monitoring.

User Identification System Based on Iris Information Using a Mouse (홍채 정보 기반 마우스를 활용한 사용자 인증 시스템)

  • Kim Sin-Hong;Rho Kwang-Hyun;Moon Soon-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.1
    • /
    • pp.143-150
    • /
    • 2006
  • Recently, the fields such as internet banking and electronic commerce are more and more growing due to the growth of practical use of personal computer and the progress of communication technology, So importance of information security has been increased. In fact, traditional identification systems are inherently insecure because the personal identification information can be forgotten, stolen or lost. In this paper, we propose an identification system that can decide whether the user is registered based on iris information using a mouse. The proposed system is mounted a CCD camera and an illumination device on general type mouse. Then it decides whether the user is registered after the acquired image are processed and analyzed. This system gives a PC user the advantage of low-cost and convenience without necessity preparing high-cost equipment for biometrics when using a identification system.

  • PDF

A Study on Practice of Infection Control among Dental Staffs in Dental Office (치과진료실에서의 직종별 감염방지 실천 정도에 관한 조사 연구)

  • Lee, Yeong-Ae;Jo, Min-Jung;Bae, Ji-Young;Park, Hyun-Sook
    • Journal of dental hygiene science
    • /
    • v.7 no.4
    • /
    • pp.263-269
    • /
    • 2007
  • To investigate the actual conditions management of infectious prevention in dental office, questionnaire about infection control and education of infection control was performed on 50 dentists, 176 dental hygienists, 100 aide nurses who are working in Deagu City from march to April, 2007. The results are as the following. Dentists are the highest on the health inspection's ratio, dental hygienists are the highest on vaccination's ratio. Experience ratio about education of infection control is the highest on dentist and the lowest on aide nurses(p < 0.05). Dental hygienists are higher than dentists and aide nurses on ratio of wearing protective gear(p < 0.05). Dentists have the highest ratio on washing hands after treat(p < 0.05). Practice of instrument's sterilization is higher in dental hygienist than other groups. Disinfection of equipment's surface practice mainly on bracket table, dental hygienist's ratio is the highest among the three groups.

  • PDF

A Study on Recognition of Infection Control among Dental Staff (치과의료종사자들의 감염방지에 대한 인식)

  • Park, Hyun-Sook;Bae, Ji-Young;Lee, Yeong-Ae;Jo, Min-Jung
    • Journal of dental hygiene science
    • /
    • v.7 no.4
    • /
    • pp.257-262
    • /
    • 2007
  • This study aimed at recognition on infection control among dental staff. This investigation was implemented by survey and questionnaires on 50 dentists and 176 dental hygienists and 100 aide nurses who were working in Deagu. The results is 1. Dental staff was recognition that extremely dangerous infectious disease is hepatitis B in dental clinic. 2. Wearing gloves and rubber dam was high in degree of recognition on using of personal protective gears however, put on apron was low. 3. The degree of recognition about sterilization of dental instruments was more higher on dentist and dental hygienists than aide nurse. 4. Dental hygienists were higher than other groups on degree of recognition about managing of dental equipment's surface.

  • PDF

A Study on the Threats of Wiretapping and Effective Security Management Strategies (도청보안의 취약성 및 개선방안에 관한 연구)

  • Lee, Young Ho;Choi, Kyung Cheol;Woo, Sang Yeob
    • Korean Security Journal
    • /
    • no.62
    • /
    • pp.347-367
    • /
    • 2020
  • Rapid advancement of technology in today's society has allowed for easy access and use of data, promoting the process of informationization. Along with the merits of such development, unintended consequences of security risks involving wiretapping have been increasing as well. The security threats posed by wiretapping technology must be addressed by every organization and individual, as it could be used to leak confidential information about the nation's security, military and diplomatic strategies, industrial technologies, and personal information. Despite increasing threats stemming from the surrounding nations using advanced wiretapping technology, there is a lack of awareness at the government level, and the existing security measures for detecting and counteracting the wiretapping equipment are ineffective. In this research, the authors offered technical suggestions for improving the security strategies against the threats of wiretapping and information leakage by conducting a content analysis. The authors suggested the units of an agency be assigned a security grade based on its importance, and that adequate security equipment should be operated according to the grade. For instance, around-the-clock surveillance is recommended for grade-1 facilities, and portable wiretapping equipment detectors should be used to protect conference rooms and other key sites.

Mobile Robot for Indoor Air Quality Monitoring (이동형 실내 공기질 측정 로봇)

  • Lee, So-Hwa;Koh, Dong-Jin;Kim, Na-Bin;Park, Eun-Seo;Jeon, Dong-Ryeol;Bong, Jae Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.537-542
    • /
    • 2022
  • There is a limit to the current indoor air quality (IAQ) monitoring method using fixed sensors and devices. A mobile robot for IAQ monitoring was developed by mounting IAQ monitoring sensors on a small multi-legged robot to minimize vibration and protect the sensors from vibration while robot moves. The developed mobile robot used a simple gait mechanism to enable the robot to move forward, backward, and turns only with the combination of forward and reverse rotation of the two DC motors. Due to the simple gait mechanism, not only IAQ data measurements but also gait motion control were processed using a single Arduino board. Because the mobile robot has small number of electronic components and low power consumption, a relatively low-capacity battery was mounted on the robot to reduce the weight of the battery. The weight of mobile robot is 1.4kg including links, various IAQ sensors, motors, and battery. The gait and turning speed of the mobile robot was measured at 3.75 cm/sec and 14.13 rad/sec. The maximum height where the robot leg could reach was 33 mm, but the mobile robot was able to overcome the bumps up to 24 mm.

Composition and Use of Biosafety Level 3 Facility (생물안전 3등급 연구시설의 구성 및 이용)

  • Kim, Changhwan;Hur, Gyeunghaeng;Lee, Wangeol;Jung, Seongtae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.335-342
    • /
    • 2015
  • Laboratory facilities for biology are designed as biosafety level 1, biosafety level 2, biosafety level 3, and biosafety level 4. Biosafety level designations are based on a composite of the design features, construction, containment facilities, equipment, practice and operation procedures required for working with agents from the various risk groups. Generally, biosafety level 3 means the facility that is appropriate for the experiments using pathogens which can cause serious diseases by aerosol transmission. The biosafety level assigned for the specific work to be done is driven by professional judgement based on a risk assessment, rather than by automatic assignment according to the particular risk group designation of the pathogenic agents to be used. In this paper, we introduced the biosafety level 3 facility operated in ADD(Agency for defense development). It contains the overview of facility, microbiological experiment, animal experiment, decontamination and waste disposal. Biosafety level 3 laboratory in ADD has served the vital role in the research of biological agents and antidote development.