• Title/Summary/Keyword: 개발 신뢰

Search Result 6,560, Processing Time 0.047 seconds

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.

Study on the Perceptions and Purchasing Realities of Consumers for Onion Hot-Water Extracts (양파열수추출물에 대한 소비실태 조사)

  • Kim, Su-Ryeom;Kim, Chang-Soon;Oh, Hyeon-Ju
    • Korean journal of food and cookery science
    • /
    • v.25 no.4
    • /
    • pp.395-405
    • /
    • 2009
  • In this study, a survey was conducted to determine consumer perceptions and satisfaction for onion hot-water extracts. Among the study subjects, females (53.3%) were in greater number than males, and individuals in their 40s (35.1%) made up the largest group. Cocerning the detailed efficacy of onion hot-water extracts, most respondents (84.5%) were aware of their efficacy and females recognized this more than males (p<0.001). Most consumers (67.3%) purchased onion hot-water extracts from 'health food stores prepared using a double boiler', and many consumers (47.4%) received information on the extracts from families and relatives. Of the respondents, 51.8% said they purchased 'quantities for $1{\sim}3$ months' at one time, and 33.1% stated that the price of onion hot-water extracts was expensive. They considered 'health' the most important aspect when purchasing, and preferred 'pouch packs' (60.3%) and considered 'easiness to open convenience to drink, and safety' (42.0%) the most important product features. Also, 62.8% of the respondents consumed onion hot-water extracts, and many drank them $1{\sim}3$ times a week, with '70 mL' as one dose, and drank them 'regardless of time'. The consumers were satisfied with the listing of health effects, but were not satisfied with the 'taste', 'smell', or 'color' of products. Concerning advertisements for the efficacy of onion hot-water extracts, 72.5% replied 'I trust them a little'. And concerning the expanding onion hot-water extract market, many respondents said it is difficult to choose an onion hot-water extract due to many similar products at the market. They also requested improvements of taste and flavor.

Effect of the Kind and Content of Raw Materials on Dynamic Modulus of Elasticity of Hybrid Composite Boards Composed of Green Tea, Charcoals and Wood Fiber (녹차-숯-목재섬유 복합보드의 동적탄성률에 미치는 구성원료의 종류 및 배합비율의 영향)

  • Park, Han-Min;Heo, Hwang-Sun;Sung, Eun-Jong;Nam, Kyeong-Hwan;Lim, Jae-Seop;Byeon, Hee-Seop
    • Journal of agriculture & life science
    • /
    • v.46 no.6
    • /
    • pp.75-86
    • /
    • 2012
  • In this study, eco-friendly hybrid composite boards were manufactured from green tea, 3 kinds of charcoals and wood fiber for developing interior materials to reinforce the strength performances and the functionalities in addition to performances of the hybrid composite boards composed of green tea and wood fiber. The effects for the kind and the component ratio of raw materials on dynamic MOE (modulus of elasticity) were investigated, and static bending strength performances were nondestructively estimated. Dynamic MOEs were highest in the hybrid composite boards composed of green tea, fine charcoal and wood fiber on the whole. However, the difference caused by the kind of charcoals was small. These values decreased with increasing component ratios of green tea and charcoals. The hybrid composite boards using $E_1$ grade urea resin had the higher values than those using $E_0$ grade urea resin, however the difference between them markedly decreased than that of hybrid composite board composed of green tea and wood fiber, and it was found that these values were markedly improved than those of the hybrid composite boards composed of green tea and wood fiber. There were mostly high correlations with significance at 1% level between dynamic MOEs and static bending strength performances, and this means that the static bending strength performances can be estimated from dynamic MOE.

Methods of Incorporating Design for Production Considerations into Concept Design Investigations (개념설계 단계에서 총 건조비를 최소로 하는 생산지향적 설계 적용 방법)

  • H.S.,Bong
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.3
    • /
    • pp.131-136
    • /
    • 1990
  • 여러해 전부터 선박의 생산실적이나 생산성 관련 자료를 기록하고 보완하는 작업을 꾸준히 개선토록 노력해온 결과중 중요한 것 하나는, 선박의 여러 가지 설계 검토과정에서 충분히 활용할 수 있는 함축성 있고 믿을만한 형태의 생산정보를 제공해줄 수 있게 되었다는 것이라고 말 할 수 있겠다. 이러한 자료들은 생산계획상 각 단계(stage)에서의 작업량, 예상재료비와 인건비의 산출등이 포함될 수 있으며, 선박이나 해상구조물의 전반적인 설계방법론(design methodology)을 개선코자 한다면 ''생산지향적 설계(Design for Production)''의 근간이 되는 선박건조전략(build strategy), 구매정책(purchasing policy)과 생산기술(production technology)에 대한 폭넓은 지식이 한데 어우러져야 한다. 최근에는 CIMS의 일부분에서 보는 바와 같은 경영관리, 설계 및 생산지원 시스템의 도입으로 이와 같은 설계 프로세스의 추진을 가능케하고 있다. 이와 병행하여 설계를 지원하기 위한 전산기술, 특히 대화형 화상처리기술(interactive graphics)의 발달은 설계자가 선박의 형상이나 구조 배치를 여러 가지로 변화시켜 가면서 눈으로 즉시 확인할 수 있도록 설계자의 능력을 배가시키는데 크게 기여하고 있다. 여러 가지의 설계안(alternative design arrangement)을 신속히 만들어내고 이를 즉시 검토 평가할 수 있는 능력을 초기설계 단계에서 가질 수 있다면 이는 분명히 큰 장점일 것이며, 더구나 설계초기 단계에 생산관련인자를 설계에서 고려할 수 있다면 이는 더욱 두드러진 발전일 것이다. 생산공법과 관련생산 비용을 정확히 반영한 각 가지의 설계안을 짧은 시간내에 검토하고 생산소요 비용을 산출하여 비교함으로써, 수주계약단계에서 실제적인 생산공법과 신뢰성있는 생산실적자료를 기준으로 하여 총 건조비(total production cost)를 최소로 하는 최적의 설계를 선택할 수 있도록 해 줄 것이다. 이제 이와 같은 새로운 설계도구(design tool)를 제공해 주므로써 초기설계에 각종 생산관련 정보나 지식 및 실적자료가 반영가능토록 발전되었다. 본 논문은 영국의 뉴카슬대학교(Univ. of Newcastle upon Type)에서 위에 언급한 특징들을 반영하여 새로운 선박구조 설계 방법을 개발한 연구결과를 보여주고 있다. 본 선계연구는 5단계로 구분되는데; (1) 컴퓨터 그라픽스를 이용하고 생산정보 데이타베이스와 연결시켜 구조형상(geometry)을 정의하고 구조부재 칫수(scantling) 계산/결정 (2) 블럭 분할(block division) 및 강재 배치(panel arrangement)의 확정을 위해 생산기술 및 건조방식에 대한 정보 제공 (3) 상기 (1) 및 (2)를 활용하여 아래 각 생산 단계에서의 생산작업 분석(work content assessment) a) 생산 준비 단계(Preparation) b) 가공 조립 단계(Fabrication/Assembly) c) 탑재 단계(Erection) (4) 각각의 설계(안)에 대하여 재료비(material cost), 인건비(labour cost) 및 오버헤드 비용(overhead cost)을 산출키 위한 조선소의 생산시설 및 각종 품셈 정보 (5) 총 건조 비용(total production cost)을 산출하여 각각의 설계안을 비교 검토. 본 설계 방식을 산적화물선(Bulk Carrier) 설계에 적용하여 구조배치(structural geometry), 표준화의 정도(levels of standardisation), 구조생산공법(structural topology) 등의 변화에 따른 설계 결과의 민감도를 분석(sensitivity studies)하였다. 전산장비는 설계자의 대화형 접근을 용이하도록 하기 위해 VAX의 화상 처리장치를 이용하여 각 설계안에 대한 구조형상과 작업분석, 건조비 현황 등을 제시할 수 있도록 하였다. 결론적으로 본 연구는 설계초기 단계에서 상세한 건조비 모델(detailed production cost model)을 대화형 화상 처리방법에 접합시켜 이를 이용하여 여러가지 설계안의 도출과 비교검토를 신속히 처리할 수 있도록 함은 물론, 각종 생산 실적정보를 초기설계에 반영하는 최초의 시도라고 믿으며, 생산지향적(Design for Production) 최적설계분야의 발전에 많은 도움이 되기를 기대해 마지 않는다. 참고로 본 시스템의 설계 적용결과를 부록에 요약 소개하며, 상세한 내용은 참고문헌 [4] 또는 [7]을 참조 요망한다.

  • PDF

A Comparison Study of Alkalinity and Total Carbon Measurements in $CO_2$-rich Water (탄산수의 알칼리도 및 총 탄소 측정방법 비교 연구)

  • Jo, Min-Ki;Chae, Gi-Tak;Koh, Dong-Chan;Yu, Yong-Jae;Choi, Byoung-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.1-13
    • /
    • 2009
  • Alkalinity and total carbon contents were measured by acid neutralizing titration (ANT), back titration (BT), gravitational weighing (GW), non-dispersive infrared-total carbon (NDIR-TC) methods for assessing precision and accuracy of alkalinity and total carbon concentration in $CO_2$-rich water. Artificial $CO_2$-rich water(ACW: pH 6.3, alkalinity 68.8 meq/L, $HCO_3^-$ 2,235 mg/L) was used for comparing the measurements. When alkalinity measured in 0 hr, percent errors of all measurement were 0~12% and coefficient of variation were less than 4%. As the result of post-hoc analysis after repeated measure analysis of variance (RM-AMOVA), the differences between the pair of methods were not significant (within confidence level of 95%), which indicates that the alkalinity measured by any method could be accurate and precise when it measured just in time of sampling. In addition, alkalinity measured by ANT and NDIR-TC were not change after 24 and 48 hours open to atmosphere, which can be explained by conservative nature of alkalinity although $CO_2$ degas from ACW. On the other hand, alkalinity measured by BT and GW increased after 24 and 48 hours open to atmosphere, which was caused by relatively high concentration of measured total carbon and increasing pH. The comparison between geochemical modeling of $CO_2$ degassing and observed data showed that pH of observed ACW was higher than calculated pH. This can be happen when degassed $CO_2$ does not come out from the solution and/or exist in solution as $CO_{2(g)}$ bubble. In that case, $CO_{2(g)}$ bubble doesn't affect the pH and alkalinity. Thus alkalinity measured by ANT and NDIR-TC could not detect the $CO_2$ bubble although measured alkalinity was similar to the calculated alkalinity. Moreover, total carbon measured by ANT and NDIR-TC could be underestimated. Consequently, it is necessary to compare the alkalinity and total carbon data from various kind of methods and interpret very carefully. This study provide technical information of measurement of dissolve $CO_2$ from $CO_2$-rich water which could be natural analogue of geologic sequestration of $CO_2$.

Factors Affecting Posttraumatic Stress of Emergency Medical Personnels (구급대원의 외상성 스트레스 영향요인)

  • Baek, Mi-Lye
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • This study not only investigates emergency medical personnel's posttraumatic stress(PTS), social support, work burden, and coping style but also identifies related factors which were exerted influence on PTS and active coping method of emergency medical personnels among the firefighters. The data were gathered from 143 emergency medical personnels who were receiving training. The data were collected by IES-R, consisting of twenty-two questions that determine the level of PTS, method used in Cho's research(2000) that deal with work burden, method used in Oh's article (2006) relating to social support, and sixty-two questions that deals with coping methods. Then the data gathered were analyzed using SPSSWIN 14.0 program. PTS of general characteristics showed significant difference in age, marriage status, education, and position. High risk group of PTS was 74(51.7%). Work burden, active and passive coping method, and three symptoms in PTS are significantly high(p=0.000) in high risk group. PTS was correlated with work burden(r=0.508, p=0.000), active coping method(r=0.375, p=0.000), and passive coping method(r=0.505, p=0.000) but not with social support. Related factors of PTS were work burden(0.371) and passive coping method(0.366). Also related factors of high risk group of PTS were work burden(odds ratio=1.064, 95% confidence interval:1.031-1.103) and passive coping(odds ratio=1.050, 95% confidence interval:1.022-1.080). Related factors of active coping method were PTS(0.392) and social support(0.158). To minimize the PTS of emergency medical personnels, the new policy should decrease their work burden and passive coping method and strengthen the social support to encourage active coping method.

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.

Design of accelerated life test on temperature stress of piezoelectric sensor for monitoring high-level nuclear waste repository (고준위방사성폐기물 처분장 모니터링용 피에조센서의 온도 스트레스에 관한 가속수명시험 설계)

  • Hwang, Hyun-Joong;Park, Changhee;Hong, Chang-Ho;Kim, Jin-Seop;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.451-464
    • /
    • 2022
  • The high-level nuclear waste repository is a deep geological disposal system exposed to complex environmental conditions such as high temperature, radiation, and ground-water due to handling spent nuclear fuel. Continuous exposure can lead to cracking and deterioration of the structure over time. On the other hand, the high-level nuclear waste repository requires an ultra-long life expectancy. Thus long-term structural health monitoring is essential. Various sensors such as an accelerometer, earth pressure gauge, and displacement meter can be used to monitor the health of a structure, and a piezoelectric sensor is generally used. Therefore, it is necessary to develop a highly durable sensor based on the durability assessment of the piezoelectric sensor. This study designed an accelerated life test for durability assessment and life prediction of the piezoelectric sensor. Based on the literature review, the number of accelerated stress levels for a single stress factor, and the number of samples for each level were selected. The failure mode and mechanism of the piezoelectric sensor that can occur in the environmental conditions of the high-level waste repository were analyzed. In addition, two methods were proposed to investigate the maximum harsh condition for the temperature stress factor. The reliable operating limit of the piezoelectric sensor was derived, and a reasonable accelerated stress level was set for the accelerated life test. The suggested methods contain economical and practical ideas and can be widely used in designing accelerated life tests of piezoelectric sensors.

Recent Changes in Bloom Dates of Robinia pseudoacacia and Bloom Date Predictions Using a Process-Based Model in South Korea (최근 12년간 아까시나무 만개일의 변화와 과정기반모형을 활용한 지역별 만개일 예측)

  • Kim, Sukyung;Kim, Tae Kyung;Yoon, Sukhee;Jang, Keunchang;Lim, Hyemin;Lee, Wi Young;Won, Myoungsoo;Lim, Jong-Hwan;Kim, Hyun Seok
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.3
    • /
    • pp.322-340
    • /
    • 2021
  • Due to climate change and its consequential spring temperature rise, flowering time of Robinia pseudoacacia has advanced and a simultaneous blooming phenomenon occurred in different regions in South Korea. These changes in flowering time became a major crisis in the domestic beekeeping industry and the demand for accurate prediction of flowering time for R. pseudoacacia is increasing. In this study, we developed and compared performance of four different models predicting flowering time of R. pseudoacacia for the entire country: a Single Model for the country (SM), Modified Single Model (MSM) using correction factors derived from SM, Group Model (GM) estimating parameters for each region, and Local Model (LM) estimating parameters for each site. To achieve this goal, the bloom date data observed at 26 points across the country for the past 12 years (2006-2017) and daily temperature data were used. As a result, bloom dates for the north central region, where spring temperature increase was more than two-fold higher than southern regions, have advanced and the differences compared with the southwest region decreased by 0.7098 days per year (p-value=0.0417). Model comparisons showed MSM and LM performed better than the other models, as shown by 24% and 15% lower RMSE than SM, respectively. Furthermore, validation with 16 additional sites for 4 years revealed co-krigging of LM showed better performance than expansion of MSM for the entire nation (RMSE: p-value=0.0118, Bias: p-value=0.0471). This study improved predictions of bloom dates for R. pseudoacacia and proposed methods for reliable expansion to the entire nation.

Mechanical Property Evaluation of Dielectric Thin Films for Flexible Displays using Organic Nano-Support-Layer (유기 나노 보강층을 활용한 유연 디스플레이용 절연막의 기계적 물성 평가)

  • Oh, Seung Jin;Ma, Boo Soo;Yang, Chanhee;Song, Myoung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.33-38
    • /
    • 2021
  • Recently, rollable and foldable displays are attracting great attention in the flexible display market due to their excellent form factor. To predict and prevent the mechanical failure of the display panels, it is essential to accurately understand the mechanical properties of brittle SiNx thin films, which have been used as an insulating film in flexible displays. In this study, tensile properties of the ~130 nm- and ~320 nm-thick SiNx thin films were successfully measured by coating a ~190 nm-thick organic nano-support-layer (PMMA, PS, P3HT) on the fragile SiNx thin films and stretching the films as a bilayer state. Young's modulus values of the ~130 nm and ~320 nm SiNx thin films fabricated through the controlled chamber pressure and deposition power (A: 1250 mTorr, 450 W/B: 1000 mTorr, 600 W/C: 750 mTorr, 700 W) were calculated as A: 76.6±3.5, B: 85.8±4.6, C: 117.4±6.5 GPa and A: 100.1±12.9, B: 117.9±9.7, C: 159.6 GPa, respectively. As a result, Young's modulus of ~320 nm SiNx thin films fabricated through the same deposition condition increased compared to the ~130 nm SiNx thin films. The tensile testing method using the organic nano-support-layer was effective in the precise measurement of the mechanical properties of the brittle thin films. The method developed in this study can contribute to the robust design of the rollable and foldable displays by enabling quantitative measurement of mechanical properties of fragile thin films for flexible displays.