• Title/Summary/Keyword: 개구 크기

Search Result 210, Processing Time 0.027 seconds

A Planar Spiral Antenna of Multi-Tabs for Wireless Power Transmission of Inductive Coupling (전자기 유도 방식 무선 전력 전송을 위한 다중 탭을 갖는 평판형 스파이럴 안테나)

  • Kim, Jin-Wook;Son, Hyeon-Chang;Jeong, Seung-Ho;Kim, Seung-Gyun;Kim, Kwan-Ho;Park, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.753-760
    • /
    • 2009
  • In this paper, a novel planar spiral antenna of multi-tabs is proposed for wireless power transmission system based on low frequency magnetic inductive coupling. The proposed antenna has higher transmission efficiency than conventional antennas such a rectangular spiral antenna and a spiral antenna. Also, it has a useful property of uniform power transmission in the region of the antenna aperture. For verification, a transmitting antenna and a receiving one for a wireless power transmission system using magnetic inductive coupling of 132 kHz low frequency are designed and tested. The transmitting antenna has three-tabs spiral of unequal-space for higher uniform magnetic coupling in the antenna aperture. For reducing the receiving antenna size, two receiving antennas of unequal space two-tabs on one-side and series double sides as well are designed, respectively. From measurement, transmission efficiency of the proposed antennas is improved up to $3{\sim}10$ dB compared to conventional antennas.

Effets of Steel Fiber Contents on Flexural Creep Behavior of High-Strength Concrete (강섬유 혼입률에 따른 고강도 콘크리트의 휨 크리프 특성)

  • Lim, Seong-Hoon;Kim, Dong-Hwi;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.111-118
    • /
    • 2020
  • In this paper, the flexural creep behavior of hooked-end steel fiber reinforced high-strength concrete was evaluated to investigate the steel fiber content influence on long-term behavior of flexural members. An experimental program consisted of nine prismatic beam specimens with dimensions of 150 × 150 × 600mm reinforced with different contents of steel fiber (0, 0.75 and 1.5% at the volume fraction). To introduce flexural creep loading to notched prismatic beam specimens, a four-point bending test setup was used. The sustained load with 40% of the flexural strength was applied by means of a lever system and controlled by a load cell for 90 days. During sustained loading, crack mouth opening displacement (CMOD) was monitored. Conventional flexural test after creep tests were carried out to evaluate the residual capacity of each specimen. Test results showed that steel fiber content has a significant effect on the flexural creep behavior of high-strength concrete and long-term flexural load with 40% of flexural strength doesn't generate negative effects on the residual capacity of steel fiber reinforced high-strength concrete.

CORRECTION OF MICROSTOMIA BY BILATERAL COMMISSUROPLASTY USING "OVER AND OUT" BUCCAL MUCOSA FLAPS: REPORT OF A CASE (협점막 외전 피판을 이용한 양측성 구각성형술에 의한 소구증의 교정 1예)

  • Ryu, Sun-Youl;Kim, Hyun-Syeob;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.4
    • /
    • pp.380-385
    • /
    • 2008
  • Microstomia can be occurred as a result of direct injury to tissues such as chemical, thermal and electrical burns, and animal bites. It also may be secondary to contracture of burned perioral skin, or may result from scarring after reconstructive lip surgery. Narrowing of the oral aperture is not only disfiguring, but also limiting the oral access needed for introduction of food, insertion of dentures, oral hygiene, and dental treatment. Limited mouth opening may also interfere with mastication and speech. Few reports exist regarding correction of microstomia and reconstruction of the corners of the mouth. A 16-year-old girl with a bilateral cleft lip and palate presented with the limited mouth opening (approximately 20 mm), the esthetic problem due to the small lip, and the cleft lip-nasal deformity. The microstomia was corrected by bilateral commissuroplasty using "over and out" buccal mucosa flaps proposed by Converse. The intercommissure distance was increased from the preoperative 40 mm to the postoperative 60 mm. The one-year postoperative intercommissure distance was 54 mm, because the 6 mm relapse was occurred. The bilateral commissuroplasty using "over and out" buccal mucosa flap could increase the width and general size of the oral aperture and improve the lip appearance.

A Clinical Report on the Effect of CRS Usage in Degenerative Temporomanibular Joint Disease with Anterior Open Bite Applying Bone Scan (전치부 개교합을 보이는 퇴행성 관절질환에서 골스캔을 이용한 중심위교합장치의 효과 평가에 대한 임상례)

  • 박상배;김병국
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.3
    • /
    • pp.289-294
    • /
    • 1998
  • 본 증례는 측두하악관절의 퇘행성 변화를 보이는 환자에서 악교정 수술의 시행 전에 중심위교합장치를 통해 측두하악관절의 안정화를 유도하고, 또한 골스캔을 이용하여 장치의 치료효과를 평가한 임상증례이다. 환자는 24세의 여성으로 5년 전부터 전치부 개교합이 발생되기 시작하였고, 고형식 저작시 좌측 전이부에 간헐적인 통증이 발생한다는 주소로 본원에 내원하였다. 임상검사상 촉진시 양측 관절낭 후방부에 압통을 호소하였으며, 각각 50, 45mm의 최대개구량 및 최대무통성 개구량을 보였다. 좌측 악관절부에서 단순 관절 잡음, 우측 악관절부에서 염발음이 청취되었으며, 저항검사 및 부하 검사에서는 특기할 반응을 보이지 않았다. 약 7mm의 전치부 개교합의 소견을 보였으며, 파노라마 사진과 횡두개 방사선 사진 소견상 양측 과두의 크기 및 하악지의 높이가 다소 작은 소견이 관찰되었고 자기공명영상 소견상 양측성 비정복성 관절원판의 전방전위가 관찰되었다. 1997년 10월 27일 첫 번째 골스캔 소견상 양측성 비정복성 관절원판의 전방위가 관찰되엇다. 골스캔의 전방 사진에서 Densitometer를 이용하여 좌, 우측 과두부위와 상악 골부위의 가장 어두운 부분의 흑화도를 측정하였다. 각각 3회씩 구하여 평균을 구하고 좌, 우측 과두 대 상악골의 흑화도의 비율을 계산하였다. 첫번째 골스캔의 평균 흑화도는 우측 과두, 좌측과두, 상악골이 각각 0.88, 0.81, 1.32 였다. 1997년 11월 4일 중심위교합장치를 장착하였고 지속적인 물리치료를 시행하였다. 1997년 12월 10일 두 번째 골 스캔을 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.33, 0.37, 088 이었다. 1998년 1월 30일 세 번째 골스캔 소견상 두 번째 골스캔과 비교하여 활성도가 감소된 소견을 보였다. 임상검사시 무통이었다. 1998년 2월 25일 술 전 교정 위해 중심위교합장치의 장작을 중지시켰다. 1998년 6월 5일 네 번째 골스캔 소견상 이전 검사들과 비교시 흡수가 감소된 소견을 보였다. 네 번째 골스캔의 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.24, 0.19, 0.85 였다. 현재 지속적인 관찰 중이며 본원 교정과에서 악교정수술 위한 술 전 교장을 시행중이다. 결국 첫 번째 골스캔의 과두 대 상악골의 평균 흑화도의 비율은 우측과 좌측이 각각 0.66, 0.61이었고 두 번째 골스캔에서는 우측과 좌측이 각각 0.37, 0.42였고, 네번째 골스캔에서는 우측과 좌측이 각각 0.28, 0.23 이었다. 각 골스캔의 과두 대 상악골의 평균 흑화도의 비율 사이에 유의한 차이가 있는지 검증하기 위해 Standard t-test 와 ANOVA를 시행하였다. 이상의 결과에서 첫 번째, 두 번째, 네 번째 골스캔으로 갈수록 좌, 우측 과두 대 상악골의 흑화도의 비율이 유의하게 감소했음을 알 수 있었다. 결론적으로 본 증례에서는 전치부 개교합이 발생되어 악교정수술이 필요한 환자에게 측두하악관절의 안정화를 위해 중심위교합장치를 사용함으로써 퇴행성 관절질환의 진행을 억제시킬 수 있고, 퇴행성 관절질환의 활성도에 대한 평가시 골스캔이 유용할 수 있음을 보여주었다고 사료된다.

  • PDF

Qualities of spawned eggs during the spawning period in red spotted grouper, Epinephelus akaare (산란기간중의 붉바리 난질 변화)

  • Lee, Chang-Kyu;Hur, Sung-Bum;Park, Seung;Kim, Byung-Gyoon
    • Journal of Aquaculture
    • /
    • v.10 no.4
    • /
    • pp.463-472
    • /
    • 1997
  • Floating and hatching rates, size and survival activity index(SAI) of spawned eggs of red spotted grouper, Epinephelus akaara were studied to understand egg qualities during the spawning periods in 1992, 1993 and 1995. The fish spawned from mid-July to mid-August when temperature ranged 23~$28^\circC$. Floating, fertilization and hatching rates were higher in the eggs from early to middle than those from late during the spawning period. SAI ranged 1.8~9.6, and it was closely related to survival rate until mouth operning time (SMOT). Egg diameter decreased gradually with the time of spawning, while diameter of oil globule was constant during the spawning periods. Induced spawnings were carried out with one injection of HCG over 5, 000 IU/kg body weight. Floating, fertilization and hatching rates of the induced spawning eggs were higher than those of untreated ones. Thus, induced spawning method with HCG was recommended for collecting fertilized eggs in bulk. Optimal time for the collection of high quality eggs was supposed to be from early to middle during the spawning periods. Considering that egg qualities were vulnerable within the period, hatchability, incidence of malformed larvae, SMOT and SAI were factors to be considered together to get good quality of eggs.

  • PDF

Ultrastructural Study on the Cutaneous Granular Glands in Bombina orientalis Boulenger (무당개구리(Bombina orientail Boulenger) 피부 과립선의 미세구조에 관한 연구)

  • 김기영;김관선;문명진;김우갑
    • The Korean Journal of Zoology
    • /
    • v.32 no.2
    • /
    • pp.107-119
    • /
    • 1989
  • The histochemical characteristics of the cutaneous granular glands and its fine structure of the Korean fire bellied toad, Bombino orientalis Boulenger the only species inhabitated in Korea, were studied with light and electron microscopes. By the granular size and histochemical properties, the granular glands were subdivided into two types. The type I glands have small secretory granules (3.6 $\mu$ m), whereas the type II glands contain relatively larger granules (7.5 $\mu$ m). These two types of glands were simple alveolar gland, and they were commonly composed of inner glandular epithelial cells and outermost myoepithelial cells. By the histochemical reactions, these two secretory granules were not responsed to Alcian blue, but weakly positive reaction was observed in type I granular glands by the PAS reaction. And by the scanning electron microscopic observation, extemal morphology of the opening site of the gland duct was resembled to the stomata of the plant leaves. Especially the epithelial cells of the type I glands had fine reticular surface whereas, type II glands had large vesicular surface. These types of the glands conimonly had larger cavities than those of mucous glands, and forming the multinucleated unicellulr structure (syncytium) at the glandular epithelial layers. Secretory granules of these glands were originated from the rough endoplasmic reticulum of the glandular epithelial cells, and by the maturation level of the granule, morphological diversities appeared.

  • PDF

A Case of Congenital Lacrimal Ductule Fistula on Lateral Skin to the Right Upper Eyelid (우측 윗눈꺼풀 외측 피부에서 발견된 선천 눈물샘소관 샛길 1예)

  • Han, Ga Hee;Chung, In Kwon;Lee, Do Hyung;Kim, Jin Hyoung;Seo, Ji Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1181-1184
    • /
    • 2018
  • Purpose: To present a rare case of tear drainage since birth from a lacrimal ductule fistula, which is the first report in the Republic of Korea. Case summary: A 3-month-old female who presented with discharge of clear fluid from a small skin opening lateral to the right upper eyelid since birth visited the outpatient clinic. The patient was healthy and was receiving no medication. She was born on gestation age 35 weeks and 3 days. No other specific history or other ophthalmic abnormality was found. On examination, a small skin orifice approximately 2 mm diameter and no sign of infection or discoloration was observed. To relieve this symptom, the patient underwent a fistulectomy under general anesthesia. Histopathological examination of the surgical specimen was performed. The patient's symptom subsided postoperatively without recurrence. Conclusions: This is the first report in the Republic of Korea of tears draining from a lacrimal ductule fistula since birth and the subsequent clinical treatment procedures.

A Study on the transition of Explosion to Eire of LPG and Its' Prevention (LP가스 폭발 후 화재 전이 현상 및 전이 방지에 관한 연구)

  • 오규형;이성은
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.20-26
    • /
    • 2004
  • The purpose of this study is to investigate the transition mechanism and prevention mechanism of gas explosion to fire. Transition phenomena of explosion to fire of LPG in the explosion vessel of its size of TEX>$100 cm {\times} 60 cm {\times} 45 cm$ was visualized using the high speed video camera and the mechanism was analysed from the videograph. Newspaper size of $30cm {\times} 20cm$ was used for combustible sample in this experiments and LPG-air mixture was ignited by 10 ㎸ electric spark. Experimental parameter was gas concentration, size of vent area and position of combustible solid. Size of vent area were varied as $10cm {\times} 9cm, 13cm {\times} 10cm, 27cm {\times} 20cm, 40cm {\times} 27cm$, and the position of combustible was varied in 4 point. Carbon dioxide was used to study the prevention mechanism of explosion to fire transition of LPG. Based on this experiment we can find that transition possibility of explosion to fire on solid combustible from explosion is depends on concentration of LPG-air mixture and the exposure time of solid combustibles in high temperature atmosphere of flame and burnt gas. And cooling or inerting of the atmosphere after explosion can be prevent the transition of explosion to fire on solid combustibles from gas explosion.

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

Research on the Methods and Proper Provisions for Rotational Irrigation (윤환관개방법과 적정시설 연구)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2191-2205
    • /
    • 1971
  • In this research, Nong-rim No. 6 was adopted as a test variety of rice. Rice seedlings were transplanted on June 14, 1970. Roots were settled into soil on June 20 and a total number of days irrigated of $21cm{\times}21cm$ and an area of $9.9m^2$ for a test plot were accepted, planting 70 stumps of rice in a test plot. The soil in test plots are classified by soil test as oam, and its chemical contents are as shown in Table 3. Irrigation water was secured by pumping from the Sudun stream that originates at the Suho reservoir. Accordingly, the qualities of irrigation. water are considered to be the same as those of water stored in the Suho reservoir. There were 54 days of intermittent rainfalls in total during the whole 110-day period of irrigation. As a result, it is likely that the growth of rice plants was influenced by rainfall at a comparatively great degree. In order to measure the amounts of water consumption, infiltrometers, measuring devices for the decreases of water depths and lycimeters were provided. As a result of measurements, an average daily rate of infiltration was observed to be 14mm/day. It is expected from this research that the effect of increased yield will be secured by supplying optimum amounts of water for irrigation on proper times, and that the amounts of water consumption for irrigation can be saved by applying suitable irrigation methods. The test results obtained are summarized as follows: 1. Yields produced in the test plots of continuous irrigation are lower than those in the test plots of rotational irrigation, i.e., yields produced at the test plots irrigatied once in a period of 8 days are higher by 27% in average than those produced at test plots of continuous irrigation. 2. The amounts of irrigation water for test plots, which have a clay layer of 9cm in thickness and vynil diaphragm without holes, are saved by about 52% in comparison with ordinary test plots. 3. Ears are sprouted 5 days earlier at continuous irrigation plots as compared with other test plots. 4. It seems that there are growing stages of rice plants such as those of forming and sprouting of ears, in which the amounts of irrigation water are consumed more in comparison with the other stages. Therefore, it may be possible to increase of decrease the amount of irrigation water, according to the growing stage of rice plant, so as to save irrigation water.

  • PDF