An Experimental Study on Characteristics of Cooler by Oil Pressure for Decreasing Heat Load in Cold Storage (냉동창고 내 열부하 감소를 위한 유압 구동식 냉각기의 특성에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1116-1122
    • /
    • 2009
  • As a result of this study, we reached the following conclusions. With appropriate setting of oil pressure and flow rate, it operated same rotation speed with existing cooler by electrical transmission. In initial operation, a temperature of a cold storage is lower rapidly. As an internal temperature of a cold storage is lower, a decreasing rate of temperature is lower. As a result of comparing the both type, the cooler of oil pressure type showed the following results. The decreasing rate of temperature was more faster and shorter operating time was more shorter than existing cooler of electric type. The actual case of a cold storage, the cooler of oil pressure type can prevent quality deterioration and decrease power consumption. As an internal temperature of a cold storage is lower, power consumption increased rapidly, the oil pressure type showed lower power consumption. COP of two of these types decreased continuously as the internal temperature of a cold storage being reach setting temperature, and that of oil pressure type showed higher amount about 25%. As a setting temperature is lower, the number of refrigerator's operating times are less and operating time is longer, so power consumption is increased in the maintenance of a cold storage's internal temperature, power consumption of hydraulic type showed lower amount about 21~25% in two of these types.

The Effect of Radiative Heat Flux on Dynamic Extinction in Metalized Solid Propellants (복사열전달이 고체 추진제의 동적소화에 미치는 영향)

  • Jeong, Ho Geol;Lee, Chang Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.72-79
    • /
    • 2003
  • A numerical calculation was conducted to estimate and to elucidate the role of the radiative heat flux from metal particles(Al, $Al_2O_3$) on the dynamic extinction of solid propellant rocket where the rapid depressurization took place. Anon-linear flame modeling implemented by the residence time modeling for metalized propellant was adopted to evaluate conductive heat flux to the propellant surface. The radiative heat feed back was calculated with the aid of a modified comvustion-flow model as well. The calculation results with the propellant of AP:Al:CTPB=76:10:14 had revealed that the radiative heat flux is approximately 5~6% of total flux at the critical depressurization rate regardless of chamber geometry (open or confined chamber). It was also found that the dynamic extinction in open geometry could be predicted at the depressurization rate about 45% larger with radiative heat feedback than without radiation. Thus, it should be claimed that even a small amount of radiative flux 5~6% could produce a big error in predicting the critical depressurization rate of the metalized propellant combustion.

Investigation on Temperature Drop during Pressurant Discharging from Pressurant Tank of Liquid Rocket Propulsion System (II) (액체로켓추진시스템의 가압제 탱크에서 가압제 토출시 온도강하율에 대한 연구(II))

  • Chung, Yong-Gahp;Kim, Yong-Wook;Kim, Yoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.3
    • /
    • pp.279-284
    • /
    • 2008
  • Propellant pressurization system in liquid rocket propulsion system plays a role in supplying pressurant gas at a controlled pressure into the ullage space of propellant tanks. The most important design parameter for such propellant pressurization system is the temperature of pressurant gas fed from pressurant tank, which is placed inside of cryogenic propellant tank. Such pressurant is gaseous state, of which density is very sensitive to the temperature of pressurant. Previous investigation dealt with thermal correlation of pressurant and external fluid at room temperature. This study investigates the temperature variation of cryogenic pressurant (GHe) at the time when the pressurant is coming out of pressurant tank, which is submerged in a liquid oxygen, experimentally as well as numerically.

Investigation on Temperature Drop during Pressurant Discharging from Pressurant Tank of Liquid Rocket Propulsion System (II) (액체로켓추진시스템의 가압제 탱크에서 가압제 토출 시 온도강하율에 대한 연구 (II))

  • Chung, Yong-Gahp;Kwon, Oh-Sung;Cho, Nam-Kyung;Han, Sang-Yeop;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.58-64
    • /
    • 2007
  • Propellant pressurization system in liquid rocket propulsion system plays a role supplying pressurant gas at a controlled pressure into the ullage space of propellant tanks. The most important design parameter for such propellant pressurization system is the temperature of pressurant gas fed from pressurant tank, which is placed inside of cryogenic propellant tank. Such pressurant is gaseous state, of which density is very sensitive to the temperature of pressurant. Previous investigation dealt with thermal correlation of pressurant and external fluid at room temperature. This study investigates the temperature variation of cryogenic pressurant (GHe) at the time when the pressurant is coming out of pressurant tank, which is submerged in a liquid oxygen, experimentally as well as numerically.

  • PDF

Investigation on Temperature Drop during Pressurant Discharging from Pressurant Tank of Liquid Rocket Propulsion System (I) (액체로켓추진시스템의 가압제 탱크에서 가압제 토출시 온도강하율에 대한 연구 (I))

  • Chung, Yong-Gahp;Kwon, Oh-Sung;Cho, Nam-Kyung;Han, Sang-Yeop;Cho, In-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.2
    • /
    • pp.54-61
    • /
    • 2007
  • Propellant pressurization system in liquid rocket propulsion system plays a role supplying pressurant gas at a controlled pressure into the ullage space of propellant tanks. The most important design parameter for such propellant pressurization system is the temperature of pressurant gas fed from pressurant tank. Such pressurant is gaseous state, of which density is very sensitive to the temperature of pressurant. Generally for the propulsion system, which requires high thrust and is consisted of cryogenic propellant the pressurant is stored at high density and high pressure to reduce the weight of pressurant tanks, which are placed inside of cryogenic propellant tank. That is called cryogenic storage pressurization system. This study investigates the temperature variation of pressurant at the time when the pressurant is coming out of pressurant tank experimentally as well as numerically. Fluids used in this study are air and liquid oxygen as outer fluid and gaseous nitrogen and gaseous helium as pressurant respectively.

Chemical Composition Characteristics of Dustfall in Nakdong River Area (낙동강 하류역 강하먼지의 화학적 조성 특성)

  • Jeon, Byung-Il;Hwang, Yong-Sik
    • Journal of the Korean earth science society
    • /
    • v.25 no.6
    • /
    • pp.428-442
    • /
    • 2004
  • Dustfall samples were collected by the modified American dust jar (bulk type) at 5 sampling sites in the Nakdong river area from lune 2002 to May 2003. Nineteen chemical species (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Si, V, Zn, $Cl^-$, $NO_3^-$, $SO_4^{2-}$, and $NH_4^+$) were analyzed via the combination of ICP/AES, AAS, IC and UV. The purposes of this study were to qualitatively evaluate the chemical composition of dustfalls by examining their regional and seasonal distribution patterns. Computation of the enrichment factor showed that well-defined anthropogenic sources, particularly in Pb were found in the order Gamjeondong (industrial area), Wondong, Silla University, Samrangiin and Mulgum. The seasonal mean of soil contribution showed its highest value (16.3%) during the winter with an annual mean of 11.2%. The concentration ratio of [$SO_4^{2-}/NO_3^-$] was found to be highest (5.12) during the winter, while the lowest ratio value (3.30) was seen during the all. fall, Also regional equivalent ratios of [$SO_4^{2-}/NO_3^-$] were found in the order: Silla University (6.78), Gamjeondong (4.98), Mulgum (3.95), Wondong (3.85), and Samrangjin (2.87). Seasonal distribution of water soluble components for total dustfall were found in the order: spring (71.6%), summer (61.2%), fall (49.2%) and winter (48.6%) with a mean ratio of 57.6%. Regional contribution of sea salts of water soluble ions were found in the order: Silla university (34.5%), Gamjeondong (28.3%), Wondong (17.3%), Samrangiin (17.2%) and Mulgum (13.8%), the total mean contribution rate was 22.1%. As for the chemical composition of dustftll on the lower Nakdong river, there is a decreased influence of sea salt and artificial anthropogenic sources and increased influence of soil particle inland. Also, the total amount of deposition on the lower Nakdong river has decreased, with the river's surface serving as a confounding factor in resuspending dusts.

Analysis on the Error rate of Measurement Method for Fall-of-Potential Earth Resistance Using the Deviated Potential Probe Positioning (전위 전극의 위치 변화에 따른 전위 강하 접지 저항 측정 방법의 에러율 분석)

  • Han, Man-Dae;Choi, Mun-Hwan;Lee, Sang-Mu;Cho, Pyoung-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.415-417
    • /
    • 2009
  • 3점 전위 강하법을 이용하여 접지 저항을 측정하는 방법은 접지 전극과 전류 전극 그리고 전위 전극의 이격 거리 영향 관계에 따라 그 정확성이 결정된다. 하지만 실체 접지 시설을 요하는 현장에서 접지 저항을 측정하기 위한 공간 확보가 어려워 각 전극들의 정확한 위치 선정이 여의치 않는 경우가 발생할 수 있다. 이에 본 논문에서는 전위 전극의 이탈 범위와 접지 전극으로부터의 이격 거리에 따른 접지 저항 값의 오차를 측정하여 각각의 경우에 대해 통상적인 접지 저항 측정 방법에 의한 측정값과의 오차 범위를 분석해본다.

  • PDF

An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve (배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구)

  • Oh, C.;Mun, S.B.;Son, Y.G.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

Measurement and Analysis of Power Quality on Elevator Equipments (승강기설비 전원의 전력품질 측정 및 분석)

  • Bang, Sun-Bae;Bae, Seok-Myung;Kim, Gi-Hyun;Lee, Kun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.83-86
    • /
    • 2005
  • 본 논문은 대단위 아파트를 주 대상으로 서울 7개소, 경기도 7개소, 강원도 10개소, 충청도 6개소, 총 30개소에 대한 승강기설비 전원품질을 측정하고 역률 변화, 고조파, 전압변동, 전압강하 등을 분석하였다. 분석결과 승강기설비 제어반 인입구에서의 실제역률(TPF)과 기본역률(DPF)의 차이가 고조파로 인하여 크게 나타나는 것을 확인하였고, 역률의 변화는 전원측(변압기)에 가까워질수록 작아지는 것을 확인하였다. 전압 종합왜형률(VTHD)은 안정적이지만 전류 종합왜형률(CTHD)은 기준치 이상의 매우 높은 수치가 발생되었고, 전원측(변압기)에 가까워질수록 작아지는 것을 확인하였다. 승강기설비 제어반 인입구에서의 전압강하율은 기준치 5%를 상회하고 있으나, 전압변동률은 최대 5.1%로서 기준치 10% 범위에 포함되었다.

  • PDF

Pressure Drop of Integrated Hybrid System and Microbe-population Distribution of Biofilter-media (통합 하이브리드시스템의 압력강하 거동 및 바이오필터 담체의 미생물 population 분포)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.116-124
    • /
    • 2022
  • In this study, waste air containing ethanol and hydrogen sulfide, was treated by an integrated hybrid system composed of two alternatively-operating UV/photocatalytic reactor-process and biofilter processes of a biofilter system having two units with an improved design (R reactor) and a conventional biofilter (L reactor). Both a pressure drop (△p) per unit process of the integrated hybrid system and a microbe-population-distribution of each biofilter process were observed. The △p of the UV/photocatalytic reactor process turned out very negligible. The △p of the L reactor was observed to increase continuously to 4.0~5.0 mmH2O (i.e., 5.0~6.25 mmH2O/m). In case of R reactor, its △p showed the one below ca. 16~20% of the △p of the L reactor. Adopting such microbes-carrying biofilter media with high porosity as waste-tire crumb media, and the improved biofilter design, contributed to △p of this study, reduced by ca. 37~50% and 40~53%, respectively, from the reported △p of conventional biofilter packed with biofilter media of the mixture (50:50) of wood chip and wood bark. In addition, the △p of R reactor in this study, reduced by ca. 80% from the reported △p of conventional biofilter packed with biofilter media of the mixture (75:25) of scoria with high porosity and compost, was mainly attributed to adopting the improved biofilter design. On the other hand, in case of L reactor, the CFU counts in its lowest column was analyzed double as much as those in any other columns. However, in case of R reactor, its CFU counts were bigger by 50% than the one of L reactor and its microbes were evenly distributed at its higher and lower columns of Rdn reactor and Rup reactor. This phenomena was attributed to an even moisture distribution of 50~55% of R reactor at its higher and lower columns. Therefore, R reactor showed superb characteristics in terms of both △p and microbe-population-distribution, compared to L reactor.