• Title/Summary/Keyword: 강재 부식

Search Result 188, Processing Time 0.021 seconds

Evaluation of Corrosion Thickness Loss of Temporary Steel Members Exposed to A Subway Construction Site (지하철 공사현장 환경하의 가시설 강재의 부식두께감소량 추정)

  • Kim, In Tae;Jeon, Sang Hyuck;Hur, Jung Ok;Cheung, Jin Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.301-310
    • /
    • 2009
  • Steel has been widely used as a material in temporary structures. Corrosion attack often reduces the long-term durability of temporary steel members that are not protected from corrosion. In designing temporary steel structures, it is difficult to evaluate their long-term durability, since the thickness loss of steel members is not clear. In this study, laboratory and field exposure corrosion tests were performed on structural steel plate specimens, and the loss of thickness of specimens that were exposed to a subway construction site for 11 months and of specimens that were exposed to environments with controlled humidity and calcium chloride for six months were measured. Finally, a thickness loss equation was formulated based on the environmental conditions and the testing periods.

Experimentally Evaluating Fatigue Behavior of Corroded Steels Exposed in Atmospheric Environments (대기환경하에서 장기간 사용된 부식강재의 실험적 피로거동평가)

  • Mun, Jae Min;Jeong, Young Soo;Jeon, Je Hyeong;Ahn, Jin Hee;Kim, In Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.3
    • /
    • pp.193-204
    • /
    • 2017
  • Fatigue strength of temporary steels and painted structural steels corroded under outdoor atmospheric environments is not clear. In this study, fatigue tests were carried out on steel plates which were cut off from 7-year-old temporary structural member under subway construction environment and from 75-year-old Yeongdo bridge member under marine atmospheric environment. After removing corrosion production on the steel surface, 3-dimensional surface geometry of the corroded steel was measured at intervals of $1.0{\times}1.0mm$, and corrosion characteristics such as minimum, maximum and mean values of residual thicknesses were calculated. From the fatigue test and FEM analysis results, the relationship between corrosion characteristics and fatigue behavior was presented, and change in fatigue strength of the unpainted and painted steels corroded in outdoor environments was also presented.

Local Corrosion and Fatigue Damages of Steel Plates at the Boundary with Concrete (콘크리트에 접해있는 강재의 국부부식과 피로손상)

  • Kim, In Tae;Kainmua, Shigenobu;Cheung, Jin Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.313-321
    • /
    • 2008
  • Recently in Japan, fracturing was observed on the diagonal member of a through truss bridge at the boundary region with the concrete slab. Local corrosion damage where the diagonal member was enclosed in the concrete slab is an important factor in the fracture. In this study, accelerated exposure tests were carried out on concrete-steel model specimens simulating steel members at the boundary with concrete. Fatigue tests were then performed on the corroded model specimens. Accelerated exposure tests of the S6-cycle, which is carried out on the model specimens for 150, 300, 450 and 600 da ys. Their surface geometry was then measured. From the accelerated exposure test results, change in maximum and mean corrosion depths was determined according to the testing periods. The effect of local corrosion on fatigue strength was also presented based on the fatigue test results.

Flexural Strength Evaluation of PSC Beam with Loss of PS Tendon Area (PS강재의 단면적 감소에 따른 PSC보의 휨강도 평가)

  • Park, Soon-Hyung;Kim, Yong-Tae;Youn, Seok-Goo;Kim, Eun-Kyum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.309-312
    • /
    • 2008
  • This paper describes ultimate load tests which were performed to show the effects of prestress loss and tendon corrosion on the flexural strength of post-tensioned concrete beams and the occurrence of wire fracture. Five test specimens were fabricated in laboratory with the variations of the prestress of tendons and the loss of tendon area. For two specimens, small area of tendon at the center of the beam was exposed by using diameter 25mm drill and the exposed tendon was corroded using accelerated corrosion equipment. During the tests, deflections, crack width, and strain changes were measured and acoustic events were monitored with two acoustic sensors. Tests results show that the ultimate flexural strength of test specimens with corroded tendons is smaller than the predicted flexural strength which is calculated considering the loss of tendon area. It is considered that estimation of flexural strength of PSC beams with corroded tendons is very complicated just based on the loss of tendon area obtained by one-side visual inspection.

  • PDF

An Experimental Study on the Evaluation of Residual Tensile Load-carrying Capacity of Corroded Steel Plates of Temporary Structure (가시설 부식 강재의 잔존 인장 내하성능 평가에 관한 실험적 연구)

  • Kim, In-Tae;Chang, Hong-Ju;Cheung, Ji-Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.399-409
    • /
    • 2010
  • Steel structures are threatened to reduce load-carrying capacity as the cross section is decreased by corrosion. However, there has been no method in definitely evaluating residual load-carrying capacity and the effect of corrosion to the load-carrying capacity of steel. This study evaluated tensile residual load-carrying capacity of corroded steel plates by using tensile tests of specimens, which were selected from the web of temporary structure's main beam. After the surface shapes were measured and tensile tests were examined, the rust of 21 corroded specimens was, first of all, removed using a chemical method. From the tensile test result, which of reference specimens that was picked off at the flange of the same main 13-mm-thick beam and corroded specimens were based, surface geometry and correlation with the reduction of corroded thickness and strain, yield strength or tensile strength was established as constant numbers. Effective thickness of corroded steel with irregular cross sections could be calculated using average residual thickness and standard deviation. The irregular cross sections could be the evaluated tensile strength that is equalized to non-corroded uniform steel's regardless of corrosion. Also, reasonable measuring intervals of residual thickness could be proposed by using this result to apply for executive work.

Evaluation of Relative Corrosion Rate depending on Local Location and Installation of Structural Member in Steel Water Gate (강재 수문의 부재 위치 및 설치 방향에 따른 상대 부식속도 평가)

  • Ha, Min-Gyun;Jeong, Young Soo;Park, Seung hun;Ahn, Jin-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.16-24
    • /
    • 2019
  • The corrosion amounts of steel structures can be different depending on their installation condition and height. Thus, their corrosion maintenance should be considered depending on installation conditions of local structural members. In this study, an atmospheric exposure test was conducted to evaluate the corrosion amount and the corrosion rate depending on the installation condition and height of a steel water gate using monitoring steel plates and corrosion environment measuring sensors. The mean corrosion depth was evaluated using the weight loss method and the galvanic corrosion current was measured by corrosion environment measuring sensors. Local corrosion rate of local structural member in steel water gate was estimated using measured mean corrosion depths and galvanic corrosion currents. From this measurement results, the corrosion damage in horizontal member of the cross beam was highly evaluated than those of other structural member as skin plate, etc. The relative difference in the corrosion rate of a local structural member could be highly affected by local corrosion environments of steel water gate members. Therefore, an appropriate maintenance method should be considered for local corrosion damages of local structural members determined by local corrosion environments of a steel water gate.

A Fundamental Study on Evaluation of Web Crippling Strength of Corroded H-Beams (부식 H형 강재의 복부좌굴강도 추정에 관한 기초적 연구)

  • Kim, In-Tae;Shin, Chang-Hee;Cheung, Ji-Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.421-433
    • /
    • 2010
  • The most typical deterioration of steel structures is corrosion damage. However, a method to evaluate residual load-carrying capacity of corroded steel structures is not yet established. It is difficult to check current serviceability and safety of the structures. In this study, compressive tests and finite element analyses were conducted on H-beams with corroded web. Then, the effect of corrosion damage on web crippling strength and evaluation methods of the web crippling strength are studied. Based on the tests, 4 H-beam specimens used in a subway construction site and 9 H-beam specimens with different web-thickness and damaged-height underwent compression-tests. To consider loading and supporting areas in the site, compressive loading was applied in the entire region of the upper and bottom flange in 5 H-beam specimens and applied partially on the regions of the upper and bottom flange in 8 specimens. The finite element analysis of 38 parametric model specimens simulating different corrosion damages was also carried out. From experimental and analytical results, the relationships between corrosion damages in the web and residual web crippling strength are presented. Factors web crippling strength was reduced are formulated by using residual average thickness and the standard deviation of the corroded web thickness. Also, a simple evaluation method of residual web crippling strength was proposed.

The Utility of Phased Array Ultrasonic Testing(PAUT) for Corrosion Evaluation of Water Supply Steel Pipes (상수도 강관의 부식 평가에 대한 위상배열초음파(PAUT)의 활용)

  • Sang Hyeok Son;Chang Gun Shin;Jea Yeon Jeong;Jong Sik Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.490-490
    • /
    • 2023
  • 위상배열초음파검사(PAUT)는 기존 초음파검사에서 획득할 수 있었던 A-scan의 결과와 달리, 관로 내부로 진입하지 않고도 부식에 의한 강관 손상 정도를 정량적인 시각적 데이터로 파악할 수 있는 검사 기술이다. 관내부 직접조사가 가능한 상수도 강관을 대상으로 직접조사와 PAUT를 비교한 결과, PAUT는 높은 정확도와 신뢰성을 보여주었다. 또한, 강관 내부의 부식검사에서는 PAUT를 적용함으로써 관체의 부식 면적, 부식 최대 깊이, 부식 위치를 넓은 범위에서 신뢰성 높은 검사 및 결과 도출이 가능하였다. 이러한 결과는 PAUT 기술이 강재 구조물의 다양한 부식 문제를 신속하게 파악하고 해결하는 데 기여할 수 있음을 의미한다. 따라서, 본 검사 기법은 상수도 관로의 강재 진단 및 점검에 있어 높은 신뢰성 및 효율성을 보여 주는 진단기법으로써 다양한 강재 시설물의 평가에 활용성이 클 것으로 판단된다. 이에 따라 PAUT는 상수도 시설물뿐만 아니라 다양한 시설물에서도 높은 활용 가능성을 가질 것으로 예상된다.

  • PDF

Corrosion Durability Evaluation of Uncoated Structural Steel Using Accelerated Exposure Tests (부식촉진실험을 이용한 강교용 무도장 강재의 부식내구성 평가)

  • Kim, In Tae;Itoh, Yoshito
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.79-86
    • /
    • 2007
  • The corrosion durability of steel bridge coatings, such as organic and metallic coatings, is often evaluated by field exposure tests, but such tests take from several years to decades to complete. As a potential method for fast corrosion testing, accelerated exposure tests were considered in this study. The S6-cycle accelerated exposure test, specified in the Japanese Industrial Standards (JIS K5621), was carried out on uncoated structural steels for 30, 60, 90, 120 and 150 days, and the resultant weight loss was determined. The weight loss was compared with that obtained from previous field exposure tests, and acceleration factors of the S6-cycle test to field exposure test sites were determined. The application of the S6-cycle accelerated exposure tests to field environments was presented based on the acceleration factor and the amount of flying salt.

An Experimental Study on Evaluation of Axially Compressive Buckling Strength of Corroded Temporary Steel (부식 손상된 가시설 강재의 축압축 좌굴강도 추정에 관한 실험적 연구)

  • Kim, In Tae;Lee, Myoung Jin;Shin, Chang Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.135-146
    • /
    • 2011
  • Steel structures have been generally painted to prevent corrosion damage. However, the painted film is deteriorated with increase in service life, and then corrosion damage resulting in cross sectional area occurs on steel surface. As a result, the buckling strength of steel structures can be decreased due to the corrosion damages. The evaluation method of the axial buckling strength of columns about a variety of section shapes and supporting conditions have been presented, but evaluation method of buckling strength about irregular nonprismatic columns is not established. In this study, the axial buckling strength of corroded steels was evaluated based on the buckling test results of corroded steel specimens that were cut off at a temporary steel structure. The corroded specimens were picked up total 10 specimens according to various slenderness ratio from the web of a temporary structure's main beam. The length of specimens is 200, 300, 400, 500 and 600mm respectively. The rust productions were removed by the chemical treatment. Then, the surface geometry was measured at intervals of $1{\times}1mm$ by using the optical 3D digitizing system, and the residual thickness of the specimens was calculated. The axial buckling test was performed on 10 corroded specimens and 12 non-corroded specimens under the fixed-fixed support condition. From the test results, the effect of corrosion damages on axial buckling load was investigated. Regardless of corrosion damage degree, the axial buckling strength of corroded specimens and non-corroded specimens was evaluated identically by using minimum average residual thickness or average residual thickness to minus its standard deviation. Reasonable measuring intervals of residual thickness was proposed by using the results to apply for practical works.