• Title/Summary/Keyword: 강재대

Search Result 95, Processing Time 0.025 seconds

A Diachronic Study on Historical and Cultural Landscape of Songhyeon-dong, Seoul (서울 송현동(松峴洞) 일원 역사문화경관의 통시적 연구)

  • Kang, Jae-Ung;So, Hyun-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.39 no.4
    • /
    • pp.85-98
    • /
    • 2021
  • In accordance with planning to construct culture park on Songhyeon-dong (district) near Gyeongbokgung Palace, This study analyzed literature and drawings from the early Joseon Dynasty to today for the district, known as 'Songhyeon (pine hill)' to identify historical and cultural landscapes during essential times. The following are the results; First, the owners of significant lots were identified, and land use and landscape components were extracted for a diachronic examination of the landscape of the whole area of Songhyeon-dong. Songhyeon district had been regarded as the 'Inner Blue Dragon (Spot) of Gyeongbokgung Palace' in terms of geomancy since the foundation of Joseon in 1392 in that the government created and managed a 'pine forest' in the district. A state warehouse called 'bungam' was constructed, and small fruit stores, 'ujeon,' opened due to the complete reformation and urban planning led by King Taejong in 1410. From the 19th century, mansions of the upper class, such as 'Gaseonggak', 'Changnyeongwuigung' and 'Byeoksugeosajeong' were in the district. A prominent official residential complex called 'Sigeun Sataek' was constructed in 1919 after Chosen Siksan Bank purchased the site. Later, it was transferred to America in 1948 and used as the 'US Embassy Staff Quarters'. Second, the changes in the site view, associated with the aspects of society by the times, were examined by estimating the location and the time the landscape components lasted in each period extracted and identifying the physical entity. The pine forest, regarded as the 'Inner Blue Dragon' that guards the left side of the palace within the geomantic world view, was located in the highlands in the west of the site. In the same period, the flat area in the east was regarded as the 'commoner's district', the streets adjacent to various government facilities and the market, packed with people from different walks of life. From the 19th century, the gardens of the aristocrats of the capital city were created in the pine forest, turning the place into the forest in the middle of the city. The whole area of Songhyeon-dong, which existed as a large lot in the city center for a long time, was developed by Japanese imperialists in the 20th century based on the concept of 'Ideal Healthy Land,' which interrupted the placeness of Songhyeon-dong that had adhered to the traditional geomatic view of the Joseon Dynasty.

Interpretation of Landscape Restoration and Maintenance in Changgyeonggung Palace through the Preservation Principles of Cultural Heritage (문화재 보존원칙으로 본 창경궁 조경 복원정비 양상 해석)

  • Kang, Jae-Ung;So, Hyun-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.15-31
    • /
    • 2022
  • This study interpreted the logical validity of the landscape restoration and maintenance patterns of Changgyeonggung Palace, where modern landscapes coexist. The results of the study are as follows; First, the changes in the landscape restoration and maintenance attitude concerning the Changgyeonggung management organization were identified. With the establishment of the Office of the Imperial Garden, an imperial property was nationalized. The Cultural Heritage Managing Department was opened in 1961, and Changgyeonggung Palace were preserved as designated as historical sites in 1963. An environmental purification was implemented by the Changgyeonggung Office as a follow-up measure for restoration in 1983. As the Cultural Heritage Administration promoted in 1999 and the Royal Palaces and Tombs Center was established in 2019, the palace has been managed professionally as a palace landscape to provide a viewing environment. Second, In the 'Purification Period of Changgyeongwon(1954~1977)', environmental purification was carried out to restore amusement facilities, install facilities for cherry blossom viewing, and develop the place into a national zoo. In the 'Reconstruction Period of Changgyeonggung(1983~1986)', restoring function as an urban park, reserving green areas, the outside space was recreated in the traditional feel, and the forest area was generally maintained. In the 'Supplementation Period of Traditional Landscape Architecture Space(1987~2009)', a uniform green landscape was created with pine trees and various vegetation landscapes centered on the flower beds. In the 'Improvement and Maintenance Period of Viewing Environment(2010~2022), a master plan was reestablished on the premise of utilization, but maintenance has been carried out in a small scale centering on unit space. Third, regarding the validity of the landscape restoration and maintenance, It was found in terms of 'originality' that the recovery of the palace system has not been expanded for over 40 years in existing areas. The 'characteristics of the times', which shows whether multi-layered history was taken into account, Changgyeongwon was excluded from the discussion in the process of setting the base year twice. In terms of 'integrity,' the area of the Grand Greenhouse where the historic states coexists needs a maintenance policy that binds the greenhouse, carpet flower bed, and Chundangji Pond. The 'utility' identified as the utilization of spaces suggests the establishment of a sense of place in the Grand Greenhouse area, which is concentrated with programs different from other areas.

Analysis of the Naemorhedus caudatus Population in Odaesan National Park - The Goral Individually Identification and Statistical Analysis Using the Sensor Camera - (오대산국립공원 산양(Naemorhedus caudatus) 개체 수 분석 - 무인센서카메라 분석을 이용한 개체 구분 및 통계 분석 -)

  • Kim, Gyu-cheol;Lee, Yong-hak;Lee, Dong-un;Son, Jang-ick;Kang, Jae-gu;Cho, Chea-un
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • This study conducted a full survey of the goral population using sensor cameras to identify the exact habitat of the gorals that inhabit Odaesan National Park and for restoration and habitat management-focused conservation projects following the population growth. We surveyed Odaesan National Park for a year in 2018 and selected18 grids (2km×2km) first based on the survey results. We then further divided each grid into four small grids (1km×1km) and installed a total of 62 sensor cameras in 38 small girds divided by four grids(1km×1km). The survey resulted in a total of 5,096 photographed wild animals, 2,268 of which were gorals, and the analysis by the classification table of goral (horn shape (Ⓐ), ring pattern (Ⓑ), ring formation ratio (Ⓒ), and facial color (Ⓓ)) identified a total of 95 animals. The ratio of male and female was 35 males (36.8%), 46 females (48.4%), and 14 sex unknowns (14.7%), while the ratio of female and male excluding sex unknowns was 4 (male):6 (female). The horn shape (Ⓐ) and face color (Ⓓ) were the important factors for distinguishing male and female and identifying individuals. The analysis of the correlation of 81 individuals, excluding 14 individuals of unknown sex, showed a significant difference (r=-0.635, p<0.01). Since the goral population in Odaesan National Park has reached a minimum viable population, it is necessary to change the focus of the management policy of Odaesan National Park from restoration to conservation.

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

Test of Independence Between Variables to Estimate the Frequency of Damage in Heat Pipe (열수송관 파손빈도 추정을 위한 변수간 독립성 검정)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.61-67
    • /
    • 2023
  • Heat pipes located underground in urban areas and operated under high temperature and pressure conditions can cause large-scale human and economic damage if damaged. In order to predict damage in advance, damage and construction information of heat pipe are analyzed to derive independent variables that have a correlation with frequency of damage, and a simple regression analysis modified model using each variable is applied to the field. However, as the correlation between independent variables applied to the model increases, the independence between variables is harmed and the reliability of the model decreases. In this study, the independence of the pipe diameter, burial depth, insulation level of monitoring system, and disconnection or short circuit of the detection line, which are judged to be interrelated, was tested to derive a method for combining variables and setting categories necessary to apply to the frequency of damage estimation model. For the test of independence, the continuous variables pipe diameter and burial depth were each converted into three categories, insulation level of monitoring system was converted into two categories, and the categorical variable disconnection or short circuit of the detection line status was kept as two categories. As a result of the test of independence, p-value between pipe diameter and burial depth, level of monitoring system and disconnection or short circuit of the detection line was lower than the significance level (α = 0.05), indicating a large correlation between them. Therefore, the pipe diameter and burial depth were combined into one variable, and the categories of the combined variable were set to 9 considering the previously set categories. The insulation level of monitoring system and the disconnection or short circuit of the detection line were also combined into one variable. Since the insulation level is unreliable when the detection line status is disconnection or short circuit, the categories of the combined variable were set to 3.