• Title/Summary/Keyword: 강우율

Search Result 644, Processing Time 0.023 seconds

Study on Deterioration of Stone Monuments Constructed with Carbonate Rock by Acid Rain (탄산염질 암석으로 구성된 석조문화재의 산성비에 의한 손상 연구)

  • Do, Jin Young;Cho, Hyen Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.273-283
    • /
    • 2013
  • The artificial rain (pH 4.0, pH 5.6 and pH 6.85) and weathering simulation test are applied in dolomitic marble for the prediction of deterioration of the stone monuments constructed with carbonate rock by acid rain. pH of the applied rain all increase to about neutral pH after reaction of marble. The contents of $Ca^{2+}$ and $Mg^{2+}$ have increased more than twofold in two acid rain and deionized neutral rain after reaction of marble. The weight of marble is expected to decrease $0.00037kg/m^2$ each test cycle by pH 4.0 rain. This weight reduction rate of marble is 1.4 and 3.1 times more in pH 5.6 and pH 6.85 rain respectively, and 3.7 times more in only artificial weathering test. The compressive strength of marble is expected to decrease 0.2468, 0.1791 and $0.1280kg/m^2$ per test cycle with pH 4.0, pH 5.6 and pH 6.85 rain, respectively. These results mean that more acidic rain more enfeeble the strength of marble. Dolomite and small amount of calcite are precipitated in the rains after reaction of marble.

An Analysis of the water balance of Low Impact Development Techniques According to the Rainfall Types (강우 유형에 따른 저영향개발 기법별 물수지 분석)

  • Yoo, Sohyun;Lee, Dongkun;Kim, Hyomin;Cho, Youngchul
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.2
    • /
    • pp.163-174
    • /
    • 2015
  • Urbanization caused various environmental problems like destruction of natural water cycle and increased urban flood. To solve these problems, LID(Low Impact Development) deserves attention. The main objective of LID is to restore the water circulation to the state before the development. In the previous studies about the LID, the runoff reduction effect is mainly discussed and the effects of each techniques of LID depending on rainfall types have not fully investigated. The objective of this research is to evaluate the effect of LID using the quantitative simulation of rainwater runoff as well as an amount of infiltration according to the rainfall and LID techniques. To evaluate the water circulation of LID on the development area, new land development areas of Hanam in South Korea is decided as the study site. In this research, hydrological model named STORM is used for the simulation of water balance associated with LID. Rainfall types are separated into two categories based on the rainfall intensity. And simulated LID techniques are green roof, permeable pavement and swale. Results of this research indicate that LID is effective on improvement of water balance in case of the low intensity rainfall event rather than the extreme event. The most effective LID technique is permeable pavement in case of the low intensity rainfall event and swale is effective in case of the high intensity rainfall event. The results of this study could be used as a reference when the spatial plan is made considering the water circulation.

Validation of the rainfall-runoff ratio of the Namgang Dam flood inflow using physically-based runoff model for upstream residual basin (댐상류 잔유역의 물리기반 유출모형을 이용한 남강댐 유입홍수 유츌률 검증)

  • Lee, Jun;Hong, Sug-Hyeon;Kang, Boosik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.308-308
    • /
    • 2021
  • 다목적댐의 홍수조절운영에 있어서 댐유입량은 직접 관측의 어려움과 오차로 인해 정확한 유량을 산정하는데 한계가 있다. 남강댐 유역의 경우 유역면적대비 과소한 저수용량으로 말미암아 급격한 홍수유입이 발생할 경우 유출률이 비정상적 수치를 보이는 경우가 종종 발생하고 있다. 본 연구에서는 물리기반의 격자형 유출모형을 댐 직상류 잔유역에 적용하여 유출률을 산정 후 남강댐 계측유입량의 타당성을 간접적으로 검증할 수 있는 방법론을 제시하고자 한다. 댐유역에서 잔유역은 직상류 수위표지점 하류의 유역을 일컬으며, 이들 수위표지점에서 홍수시의 배수영향은 최소화될 만큼 이격되어 있고, 댐체 혹은 취수탑에 부착된 수위표와는 달리 기계적 진동의 영향이 최소화되어 있다고 가정한다면, 수위계측지점의 유량을 경계조건으로 활용하여 작은 면적에 대한 정밀한 수문학적 유출모델링을 통하여 비교적 신뢰성있는 유출값을 추정할 수 있다는 장점이 있다. 남강댐 잔유역은 유역 내 산청, 신안, 창촌 수위관측소를 기준으로 상류의 유역을 제외한 부분으로 설정하였다. 본 연구에서는 210m 격자에 대하여 모든 입력자료를 가공하였으며, 입력자료 중 지형자료는 WAMIS에서 제공한 DEM, 토지피복도, 토양도를 활용하였다. 강우자료는 유역 내 위치한 25개 강우관측소의 시단위 강우자료를 활용하였고, 강우사상은 진주 기상관측소의 일우량 100mm 이상을 기준으로 총 8개의 강우사상을 선정하였다. 남강댐 유역의 유출률을 산정하기 위해 산청, 창촌, 신안 등 3개의 수위관측소의 관측유량을 경계조건으로 사용하였고, 모의된 수문곡선의 총유량과 첨두유량을 관측값과 비교하였다. 유출률을 산정하기 위한 기준시간은 강우시작부터 강우종료 후 48시간으로 설정하였다. 유출률은 강우사상별로 편차가 심한 특성을 보이고 있었으며, 전체적으로는 계측유량기준 106~39.1%의 유출률이 보정된 유량을 통해서는 85~33%의 유출률로서 계측유량이 전반적으로 과대추정 되는 경향이 있었음을 확인할 수 있었다. 이들 중 2010년 7월 강우사상은 관측 유입량 기준 95.6%의 유출률을 보여, 추정유량 58.5%대비 상당한 과대추정 경향을 보인 사례로 판단할 수 있었다. 수문학적 유입량 추정방법은 현장계측을 대체할 수 있는 기법으로는 무리가 있으나 현장계측의 신뢰도를 평가하기 위한 목적으로는 유용한 대안이 될 수 있을 것으로 기대된다.

  • PDF

Studies on Purple Seed Stain (Cercospora kikuchii) of Native Soybean Collections (재래종대두의 자반병 감염에 관한 연구)

  • Kwon, S.H.;Ou, J.H.;Kim, J.R.;Song, H.S.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.22 no.1
    • /
    • pp.11-15
    • /
    • 1977
  • Natural infection of purple stain seemed to be higher in early maturing lines comparing to late maturing group. It was positively correlated with length of the period from flowering to maturity and significantly associated with weather conditions during the maturing period.

  • PDF

Study on Landslide Flume Tests Using Stability Analysis of the Unsaturated Infinite Slope (불포화 무한사면의 안정해석을 활용한 산사태 모형실험에 관한 연구)

  • Song, Hyo-Sung;Chae, Byung-Gon;Song, Young-Suk;Choi, Jung-Hae;Seo, Won-Gyo;Woo, Ik
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.541-552
    • /
    • 2019
  • In this study, landslide flume tests were performed to analyze characteristics of ground characteristics and landslide occurrence due to rainfall infiltration. As test materials, weathered granite soil and gneiss soil, the most frequent landslides in Korea, were used, and landslides were triggered by heavy rain (Intensity = 200 mm/hr). The measurement sensors were installed with 3 sets at toe, slope, top part and shallow (GL-0.2 m), middle (GL-0.4 m), and deep (GL-0.6 m) depth in the slope and measured at 10 second intervals. After landslide flume tests, the slope stability analysis was performed by applying the unsaturated soil theory based on the change of ground characteristics and compared with actual landslide occurrence from flume test. As a result of the analysis, factor of safety reflected the landslide occurrence from flume test and factor of safety decreased as rainfall infiltration, leading to slope failure. Finally we compared to the factor of safety below 1 and actual landslide occurrence time, the average difference was 1,600 seconds for weathered granite soil and 5,400 seconds for weathered gneiss soil.

Performance Evaluation of Vortex Screen for Treatment of Fine Particles in Storm Runoff (Vortex Screen장치를 이용한 강우유출수내 미세입자 처리특성 분석)

  • Lee, Jun-Ho;Jung, Yun-Hee;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.256-262
    • /
    • 2009
  • The use of hydrodynamic separator is becoming increasingly popular for suspended solids reduction in urban storm runoff. This study is a laboratory investigation of the use of Vortex Screen to reduce the solids concentration of synthesized storm runoff. The synthesized storm runoff was made with water and addition of particles; manhole sediment, road sediment, fly ash, and ployvinyl chloride powder. Vortex Screen was made of acryl resin with 250 mm of diameter and height of 700 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The samples were taken simultaneously at the influent storage tank and effluent tank, and measured SS and COD concentrations. The ranges of surface loading rate were 110 to 1,550 $m^3/m^2$/day, and influent SS concentrations were varied from 141 to 1,986 mg/L. This paper was intended to evaluate the effect of inlet baffle and the ratio of underflow to overflow ($Q_U/Q_O$) on particle separation efficiency for various particle size using Vortex Screen. It was found that when increase of $Q_U/Q_O$ from 10% to 20%, SS removal efficiency was increased about 6%. The range of SS and COD removal efficiencies of road sediment particle size 125<$d_p$<300 ${\mu}m$ were 68.0~81.0%, 53.1~71.9%, respectively. Results showed that SS removal efficiency with inlet baffle improved by about 10~20% compared without inlet baffle.

A Study on the Difference of Rainfall Intensity According to the Omission of Short-Term (20, 30, 40, 50 Minutes) Rainfall Data in Inducing I-D-F Curves (I-D-F곡선 유도 시 짧은 지속기간(20분, 30분, 40분, 50분) 강우자료 누락에 따른 강우강도 차이 고찰)

  • Lee, Hee Chang;Seong, Kee Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.465-475
    • /
    • 2020
  • I-D-F curves were induced by Box-Cox transformation using rainfall data from five major cities in Korea: Seoul, Busan, Daegu, Daejeon, and Gwangju, as well as from Sancheong (South Gyeongsang province) and Yeongcheon (North Gyeongsang province) stations. The practicality of the Box-Cox transformation is more scalable than the traditional method of frequency analysis in terms of applicability because it is available even if the analysis data are insufficient to perform general frequency analysis and do not produce an appropriate probability density function. For the case in which rainfall data for the entire period (10-1440 minutes) and short-term period (20, 30, 40, 50 minutes) at the foregoing 7 stations are omitted, there was a relative error of -23.0 % to 14.7 % at a duration of 10 to 60 minutes below the 100-year frequency. Accordingly, rainfall analysis requires inducing I-D-F curves, including for the short term (20, 30, 40, 50 minutes), and if rainfall data are omitted for the short term (20, 30, 40, 50 minutes), it is necessary to increase the existing margin rate depending on the point in order to ensure the safe design of small-scale hydraulic structures.

Determination of EMCs for Rainfall Ranges from Transportation Landuses (교통관련 토지이용에서의 강우계급별 EMC 산정)

  • Lee, So-Young;Maniquiz, Marla C.;Choi, Ji-Yeon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.2
    • /
    • pp.67-76
    • /
    • 2009
  • The contribution of pollutant loadings from non-point source (NPS) to the four major rivers in Korea exceeded 22~37 % of the total loadings in 2004 and is expected to reach 60 % in 2020. Most of NPS loadings are coming from urban areas, especially from paved areas. Because of high imperviousness rate, many types of NPS pollutant are accumulating on the surface during dry periods. The accumulated pollutants are wash-off during a storm and highly degrading the water quality of receiving water bodies. For this reason, the Korean Ministry of Environment (MOE) developed the Total Maximum Daily Load (TMDL) program to protect the water quality by managing the point source and NPS loadings. NPS has high uncertainties during a storm because of the characteristics of rainfall and watershed areas. The rainfall characteristics can affect on event mean concentrations (EMCs), mass loadings, flow rate, etc. Therefore, this research was performed to determine EMCs for rainfall ranges from transportation landuses such as road and parking lot. Two sites were monitored over 45 storm events during the 2006/06 through 2008/10 storm seasons. Mean TSS EMCs decrease as rainfall ranges increase and highest at less than 10mm rainfall. The results of this study can be used to determine the efficient scale of BMP facility considering specific rainfall range.

  • PDF

Analysis on the Water Circulation and Water Quality Improvement Effect of Low Impact Development Techniques by Test-Bed Monitoring (시범 단지 운영을 통한 LID 기법별 물순환 및 수질개선 효과 분석)

  • Ko, Hyugbae;Choi, Hanna;Lee, Yunkyu;Lee, Chaeyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.27-36
    • /
    • 2016
  • Low Impact Development (LID) techniques are eco-friendly storm water management process for water circulation restoration and non-point pollutant reduction. In this study, four LID techniques (Small constructed wetland, Infiltration trench box, Infiltration trench, Vegetated swale) were selected and installed as a real size at the real site. All facilities were evaluated as monitoring under the real environmental climate situation and an artificial rain with exceeding design rainfall. In various rainfall, runoff reduction efficiency and non-point pollutant removal efficiency are increased to the bigger Surface Area of LID (SA)/Catchment Area (CA) ratio and the bigger Storage Volume of LID (SV)/Catchment Area (CA) ratio. Runoff did not occur at all rainfall event (max. 17.2 mm) in infiltration trench and vegetated swale. But Small constructed wetland was more efficient at less than 10 mm, a efficiency of infiltration trench box was similar at different rainfall. Although different conditions (such as structural material of LID, rainfall flow rate, antecedent dry periods), LID techniques are good effects not only water circulation improvement but also water quality improvement.

Mathematical Description of Soil Loss by Runoff at Inclined Upland of Maize Cultivation (옥수수 재배 경사지 밭에서 물 유출에 따른 토양유실 예측 공식)

  • Hur, Seung-Oh;Jung, Kang-Ho;Ha, Sang-Keon;Kwak, Han-Kang;Kim, Jeong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.2
    • /
    • pp.66-71
    • /
    • 2005
  • Soil loss into stream and river by runoff shall be considered for non-point source pollution management as national land conservation. The purpose of this study was to develop the mathematical equation to predict soil loss from inclined uplands of maize cultivation due to the runoff by rainfall which mainly converges on July and August. Soil loss was concentrated on May because of low canopy over an entire field in 2002 and on June and July because of heavy rainfall in 2003. By regression analysis the relation between runoff and soil loss can be represented by a linear equation of y =1.5291x - 3.4933, where y is runoff ($Mg\;ha^{-1}$) and x is soil loss ($kg\;ha^{-1}$). The determination coefficient of this equation was 0.839 (P<0.001). Therefore, the mathematical equation derived from the practical experiment at the inclined upland can be applicable to predict soil loss accompanied by runoff due to periodic rainfall converging on short periods within a couple of months.