• Title/Summary/Keyword: 강건함

Search Result 1,820, Processing Time 0.025 seconds

Effects of a Growth Retardant Paclobutrazol on the Growth and Yield Related Elements of Peanut (Archis hypogea L.) (생장조정제(生長調整劑) Paclobutrazol이 땅콩의 생육특성(生育特性)과 수량관련요소(收量關聯要素)에 미치는 영향(影響))

  • Lee, H.S.;Cho, J.S.
    • Korean Journal of Weed Science
    • /
    • v.8 no.1
    • /
    • pp.71-89
    • /
    • 1988
  • This study was conducted to evaluate the effect of a growth retardant, Paclobutrazol on the growth, yield and its components. and physiological traits in peanut cv. Saeddle (early variety) and Nampung (medium variety). The results are summarized as follows : Main stem and branch length of both varieties were remarkably retarded at early growth stage application, but the retardation effect was reduced at late growth stage application. Number of branches was increased remarkably by treating 60ppm at 20days after seedling (DAS) in early variety. Lodging ill medium variety was not observed through growth period when 120ppm of Paclobutrazol was applied while lodging was not appeared between 40 DAS and 80 DAS in early variety. The numbers of riped pods in early variety was increased when application of 120ppm at 40 DAS was made while it was increased as application of 120ppm at 90 DAS in the medium variety. Cercospora leaf spot was reduced by spraying at 40 or 50 DAS regardless of concentration and varieties. Chlorophyll content and photosynthetic activity increased when paclobutrazol was applied during 40-60 DAS in early variety while these were observed at 90 DAS in medium variety. Seed weight tended to increase as paclobutrazol application was delayed. The ratio of pods to seeds was higher at 60ppm-40 DAS in early variety while it was higher at 120ppm-90 DAS in medium variety.

  • PDF

Extract from Eucheuma cottonii Induces Apoptotic Cell Death on Human Osteosarcoma Saos-2 Cells via Caspase Cascade Apoptosis Pathway (Eucheuma cottonii 추출물에 의한 인체 골육종암 Saos-2 세포의 자가사멸 유도)

  • Kang, Chang-Won;Kang, Min-Jae;Kim, Kyong Rok;Kim, Nan-Hee;Seo, Yong Bae;Kang, Keon-Hee;Kim, Sang-Ho;Kim, Gun-Do
    • Journal of Life Science
    • /
    • v.26 no.2
    • /
    • pp.147-154
    • /
    • 2016
  • Osteosarcoma (OS) is the most common and malignant bone tumors. Although many types of resection surgery and experimental agents were developed, median survival and clinical prognosis are poorly investigated. Recently, several researches have reported that Eucheuma cottonii has potent as protective effects of coal dust-induced lung damage via inhibition of malondialdehyde (MDA) and oxidative stress in bronchoalveolar lavage fluids (BALF). However, anti-cancer effects and specific molecular mechanism of extract from Eucheuma cottonii (EE) has not been clearly studied yet. This study evaluated that anti-cancer potential of EE in human osteosarcoma Saos-2 cells. EE indicated cytotoxicity on Saos-2 cells in a dose-dependent manner. Morphological degradation and nucleic condensation were also observed under the EE treatment. However, it did not significantly affect on non-cancerous kidney HEK-293 cells under the same concentration which is shown cytotoxicity on Saos-2 cells. The phosphorylation of Fas-Associated Death Domain (FADD) and expression of cleaved caspase-8, -7 and -3 were upregulated in a dose-dependent manner. In immunofluorescence staining, expression level of Fas and cleaved PARP were upregulated by EE treatment. Furthermore, treatment of EE induces upregulation of sub G1 phase by flow cytometry analysis. The results demonstrated that EE has a therapeutic potential against osteosarcoma via FADD mediated caspase cascade apoptosis signal pathway.

Quantification of Cerebrovascular Reserve Using Tc-99m HMPAO Brain SPECT and Lassen's Algorithm (Tc-99m HMPAO 뇌 SPECT와 Lassen 알고리즘을 이용한 뇌혈관 예비능의 정량화)

  • Kim, Kyeong-Min;Lee, Dong-Soo;Kim, Seok-Ki;Lee, Jae-Sung;Kang, Keon-Wook;Yeo, Jeong-Seok;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.322-335
    • /
    • 2000
  • Purpose: For quantitative estimation of cerebrovascular reserve (CVR), we estimated the cerebral blood flow (CBF) using Lassen's nonlinearity correction algorithm and Tc-99m HMPAO brain SPECT images acquired with consecutive acquisition protocol. Using the values of CBF in basal and acetaBolamide (ACZ) stress states, CBF increase was calculated. Materials and Methods: In 9 normal subjects (age; $72{\pm}4$ years), brain SPECT was performed at basal and ACZ stress states consecutively after injection of 555 MBq and 1,110 MBq of Tc-99m HMPAO, respectively. Cerebellum was automatically extracted as reference region on basal SPECT image using threshold method. Assuming basal CBF of cerebellum as 55 ml/100g/min, CBF was calculated lot every pixel at basal states using Lassen's algorithm. Cerebellar blood flow at stress was estimated comparing counts of cerebellum at rest and ACZ stress and Lassen's algorithm. CBF of every pixel at ACZ stress state was calculated using Lassen's algorithm and ACZ cerebellar count. CVR was calculated by subtracting basal CBF from ACZ stress CBF for every pixel. The percent CVR was calculated by dividing CVR by basal CBF. The CBF and percentage CVR parametric images were generated. Results: The CBF and percentage CVR parametric images were obtained successfully in all the subjects. Global mean CBF were $49.6{\pm}5.5ml/100g/min\;and\;64.4{\pm}10.2ml/100g/min$ at basal and ACZ stress states, respectively. The increase of CBF at ACZ stress state was $14.7{\pm}9.6ml/100g/min$. The global mean percent CVR was 30.7% and was higher than the 13.8% calculated using count images. Conclusion: The blood flow at basal and ACZ stress states and cerebrovascular reserve were estimated using basal/ACZ Tc-99m-HMPAO SPECT images and Lassen's algorithm. Using these values, parametric images for blood flow and cerebrovascular reserve were generated.

  • PDF

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

A Study on the Noise Attenuation Effects by Types of Forest Tree Belt (수림대(樹林帶)에 따른 소음감살효과(騷音減殺效果)에 관한 연구(硏究))

  • Lee, Ju-Hyoung;Kang, Gun-Uh
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.1
    • /
    • pp.113-123
    • /
    • 2001
  • The main purpose of this study was to provide information on attenuation effects in forest tree belt of pine stand and oak stand. The relationships between DBH, tree height, clear length, crown area and number of trees and also between distance from noise origin, landslope etc. were analysed by correlation and multiple regression. The results obtained were as follows : 1. There was no difference between pine stand and oak stand in effecting noise attenuation. 2. The noise pressure was highly correlated with all of seven elements tested and both DBH and distance from noise origin have higher r-values than the others. For the pine stand, it was 0.9133 in DBH and 0.9630 in the distance and for the oak stand, 0.9296 in DBH and 0.9565 in the distance. 3. The optimum regression equation for pine stand and oak stand were made by combination of two variables (DBH and distance). The table of noise attenuation was made by optimum regression equation. In the case of pine stand, the attenuation ratio was 29% at 5m, 31.6~32.6% at 10m, 38.3~39.8% at 20m and 45.2~46.6% at 30m. And case of oak stand, the attenuation ratio was 29% at 5m, 31.6~34.2% at 10m, 38.6~41.4% at 20m and 45~47.2% at 30m. 4. As the noise pressure limit at the Urban housing area according to environmental laws is under 55dB, it is suggested by the table of noise attenuation that the distance, and DBH for the pine and oak stand are over 20m, 400cm and 30-35 trees, respectively.

  • PDF

Relationship of Oral Health Awareness to Oral Health Indexes among Adults (성인의 구강건강인식과 구강보건지수와 관계)

  • Shin, Myong-Suk;Hwang, Mi-Yeong;Kim, Soo-Kyung
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.607-616
    • /
    • 2012
  • The purpose of this study was to examine the self-rated oral health status and oral health concern of 6,094 adults over the age of 19, which were both related to subjective oral health awareness, based on the second-year (2008) raw data of the 4th National Health and Nutrition Survey. 1. As for subjective oral health awareness, 49.4 percent replied they were in bad oral health when they were asked about self-rated oral health status. Regarding oral health concern, 62.6 percent answered they were sort of concerned about oral health. 2. As to oral health indexes by sociodemographic characteristics, there were statistically significant differences in oral health indexes according to gender, age, academic credential, monthly mean household income, frequency of eating between meals and toothbrushing frequency. Smoking made no statistically significant differences to oral health indexes (p<0.000). 3. Concerning self-rated oral health status by sociodemographic characteristics, no significant differences were found according to gender, age and academic credential, and there were statistically significant differences according to monthly mean household income and smoking (p<0.000), frequency of eating between meals (p<0.018), toothbrushing frequency (p<0.003). 4. In relation to oral health concern by sociodemographic characteristics, gender and smoking made no significant differences, and statistically significant differences were found according to age (p<0.003), academic credential, monthly mean household income, frequency of eating between meals and toothbrushing frequency (p<0.000). 5. In regard to the relationship between subjective oral health awareness and oral health indexes, none of the oral health indexes had a significant relationship to self-rated oral health status, and there were statistically significant differences in oral health concern according to functioning teeth index (p<0.011) and community periodontal index (p<0.017).

Mechanical Property Evaluation of Dielectric Thin Films for Flexible Displays using Organic Nano-Support-Layer (유기 나노 보강층을 활용한 유연 디스플레이용 절연막의 기계적 물성 평가)

  • Oh, Seung Jin;Ma, Boo Soo;Yang, Chanhee;Song, Myoung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.33-38
    • /
    • 2021
  • Recently, rollable and foldable displays are attracting great attention in the flexible display market due to their excellent form factor. To predict and prevent the mechanical failure of the display panels, it is essential to accurately understand the mechanical properties of brittle SiNx thin films, which have been used as an insulating film in flexible displays. In this study, tensile properties of the ~130 nm- and ~320 nm-thick SiNx thin films were successfully measured by coating a ~190 nm-thick organic nano-support-layer (PMMA, PS, P3HT) on the fragile SiNx thin films and stretching the films as a bilayer state. Young's modulus values of the ~130 nm and ~320 nm SiNx thin films fabricated through the controlled chamber pressure and deposition power (A: 1250 mTorr, 450 W/B: 1000 mTorr, 600 W/C: 750 mTorr, 700 W) were calculated as A: 76.6±3.5, B: 85.8±4.6, C: 117.4±6.5 GPa and A: 100.1±12.9, B: 117.9±9.7, C: 159.6 GPa, respectively. As a result, Young's modulus of ~320 nm SiNx thin films fabricated through the same deposition condition increased compared to the ~130 nm SiNx thin films. The tensile testing method using the organic nano-support-layer was effective in the precise measurement of the mechanical properties of the brittle thin films. The method developed in this study can contribute to the robust design of the rollable and foldable displays by enabling quantitative measurement of mechanical properties of fragile thin films for flexible displays.

An Optimization Study on a Low-temperature De-NOx Catalyst Coated on Metallic Monolith for Steel Plant Applications (제철소 적용을 위한 저온형 금속지지체 탈질 코팅촉매 최적화 연구)

  • Lee, Chul-Ho;Choi, Jae Hyung;Kim, Myeong Soo;Seo, Byeong Han;Kang, Cheul Hui;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.332-340
    • /
    • 2021
  • With the recent reinforcement of emission standards, it is necessary to make efforts to reduce NOx from air pollutant-emitting workplaces. The NOx reduction method mainly used in industrial facilities is selective catalytic reduction (SCR), and the most commercial SCR catalyst is the ceramic honeycomb catalyst. This study was carried out to reduce the NOx emitted from steel plants by applying De-NOx catalyst coated on metallic monolith. The De-NOx catalyst was synthesized through the optimized coating technique, and the coated catalyst was uniformly and strongly adhered onto the surface of the metallic monolith according to the air jet erosion and bending test. Due to the good thermal conductivity of metallic monolith, the De-NOx catalyst coated on metallic monolith showed good De-NOx efficiency at low temperatures (200 ~ 250 ℃). In addition, the optimal amount of catalyst coating on the metallic monolith surface was confirmed for the design of an economical catalyst. Based on these results, the De-NOx catalyst of commercial grade size was tested in a semi-pilot De-NOx performance facility under a simulated gas similar to the exhaust gas emitted from a steel plant. Even at a low temperature (200 ℃), it showed excellent performance satisfying the emission standard (less than 60 ppm). Therefore, the De-NOx catalyst coated metallic monolith has good physical and chemical properties and showed a good De-NOx efficiency even with the minimum amount of catalyst. Additionally, it was possible to compact and downsize the SCR reactor through the application of a high-density cell. Therefore, we suggest that the proposed De-NOx catalyst coated metallic monolith may be a good alternative De-NOx catalyst for industrial uses such as steel plants, thermal power plants, incineration plants ships, and construction machinery.

The Effect of Social Capital on Health-related Quality of Life - Using the Data of the 2019 Community Health Survey - (노인의 사회적 자본이 건강 관련 삶의 질에 미치는 영향 - 2019년 지역사회건강조사를 중심으로 -)

  • Kim, Ji-Hee;Park, Jong
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.4
    • /
    • pp.280-294
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the effects of social capital characteristics, socio-demographic characteristics, physical condition, and health behavior characteristics on health-related quality of life of the elderly in Korea. Methods: T-test, one-way ANOVA, and regression analysis were performed by applying a complex sample design to 57.787 people aged 65 and over using the 2019 Community Health Survey. Results: First, as a result of complex-sample T-test and ANOVA analysis, it was found that there were differences in health-related quality of life according to social capital characteristics, physical condition & health behavior characteristics, and socio-demographic characteristics. Complex Sample Regression Analysis Results, the explanatory power of the model was 28%. When living in the metropolitan area, living in an apartment building, having a spouse, having a higher household income, economic activity, higher educational attainment, increase sleeping time, walking time, frequent binge drinking, health checkup, networking, trust, and social participation showed higher health-related quality of life. When people were older, their gender was female, higher BMI, number of chronic diseases, and severe stress that showed lower health-related quality of life. Conclusions: It was proved that the factors affecting the health-related quality of life of the elderly are not only physical condition and health behavior factors, but also social capital and socio-demographic characteristics. It was found that the role as a member was important.

Optimization of GFR value according to Kidney Depth Measurement Methods (신장 Depth 측정 방법에 따른 GFR 값의 최적화)

  • Kwon, Hyeong-Jin;Moon, Il-Sang;Noh, Gyeong Woon;Kang, Keon Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Purpose In patients with unusual kidney position after $^{99m}Tc-DTPA$ renal dynamic imaging study, the GFR(Glomerular Filtration Rate) values are significantly different according to the depth of the kidney. Thus, we tried to compare the difference of the GFR values between the depth measurement methods and in-vitro test. 30 adult patients who were subjected to renal study. 27 patients were in usual position and 3 patients were in unusual. $555{\pm}37MBq$ of $^{99m}Tc-DTPA$ was administrated to all patients. GE infinia gamma camera was used. GFR values were obtained in-vivo(gates method) and in-vitro(blood). The kidney depth in-vivo was calculated by three methods(tonnensen, manual, taylor). In-vitro, GFR was performed by blood test. Differences in the mean values of GFR and correlation between depth and GFR values were evaluated using the SPSS 12.0 statistical program. The GFR values for 27 patients with kidney in the usual position are as follows(1.tonnensen 2.manual 3.taylor 4.invitro); $69.3{\pm}4.2$, $88.2{\pm}5.6$, $77.8{\pm}4.3$, $82.2{\pm}5.8ml/min$. The three unusual cases are as follows, first(congenital renal anomaly): 66.4, 101.24, 69.07, 94.8 ml/min. second(transplantation kidney): 12.22, 29.99, 19.36, 23.5 ml/min. third(horseshoe kidney): 37.37, 93.54, 35.9, 92.5 ml/min. There was a difference between tonnensen and manual in the usual position of the kidney(p<0.05). There was no significant difference between the other methods. However, there was a significant difference in case of the unusual position of the kidneys. Correlation analysis between both kidney depth and GFR value shows person correlation as follows; Rt kidney: 0.298, Lt kidney: 0.322. When compared with the GFR values in-vitro test, it was useful to calculate the GFR value by measuring the kidney depth using a manual formula in the unusual position of the kidneys. GFR values and kidney depth were significantly related.