• Title/Summary/Keyword: 감쇠 예측

Search Result 318, Processing Time 0.023 seconds

Correlation between Proximity Noise Measurement Method (CPX) and Roadside Measurement Method (SPB) for Road Traffic Noise (도로교통소음에 대한 근접소음 측정법(CPX)과 통과소음 측정법(SPB)의 상관관계)

  • Yoo, In-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.310-319
    • /
    • 2020
  • Korea estimates the traffic noise by measuring the total traffic noise when the traffic passes (SPB; Statistical Pass-By). Another method (CPX; Close Proximity) directly measures the tire/road noise by installing a microphone near the tire. The CPX method is not a formal test method in Korea. There has been little research between CPX and SPB. This study proposes a method for estimating SPB, using the CPX, which is easy to measure. This study used the results of a large-scale test conducted by Korea Expressway Corporation (KEC) and a research paper on CPX in this section. The results by the KEC showed that the low noise pavement has a noise reduction of 10.4dB. In CPX research, the noise reduction was 10.7dB and was similar to 10.4dB in SPB. This study shows why the noise reduction is the same regardless of the position, the reason that the amount of noise reduction is similar, the difference of the noise according to the position of the microphone using the concept of noise summation and distance reduction. This study shows that including the CPX as a variable in the traffic noise prediction program is very important to improve noise prediction reliability.

Clinical Significance of Focal Breast Lesions Incidentally Identified by $^{18}F-FDG$ PET/CT ($^{18}F-FDG$ PET/CT에서 우연히 발견된 국소 유방 병변의 임상적 의의)

  • Cho, Young-Seok;Choi, Joon-Young;Lee, Su-Jin;Hyun, Seung-Hyup;Lee, Ji-Young;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.456-463
    • /
    • 2008
  • Purpose: We evaluated the incidence and malignant risk of focal breast lesions incidentally detected by $^{18}F-FDG$ PET/CT. Various PET/CT findings of the breast lesions were also analyzed to improve the differentiation between benign from malignant focal breast lesions. Materials & Methods: The subjects were 3,768 consecutive $^{18}F-FDG$ PET/CT exams performed in adult females without a history of breast cancer. A focal breast lesion was defined as a focal $^{18}F-FDG$ uptake or a focal nodular lesion on CT image irrespective of $^{18}F-FDG$ uptake in the breasts. The maximum SUV and CT pattern of focal breast lesions were evaluated, and were compared with final diagnosis. Results: The incidence of focal breast lesions on PET/CT in adult female subjects was 1.4% (58 lesions in 53 subjects). In finally confirmed 53 lesions of 48 subjects, 11 lesions of 8 subjects (20.8%) were proven to be malignant. When the PET/CT patterns suggesting benignancy (maximum attenuation value>75 HU or <30HU; standard deviation of mean attenuation > 20) were added as diagnostic criteria of PET/CT to differentiate benign from malignant breast lesions along with maximum SUV, the area under ROC curve of PET/CT was significantly increased compared with maximum SUV alone ($0.680{\pm}0.093$ vs. $0.786{\pm}0.076$, p<0.05). Conclusion: The malignant risk of focal breast lesions incidentally found on $^{18}F-FDG$ PET/CT is not low, deserving further diagnostic confirmation. Image interpretation considering both $^{18}F-FDG$ uptake and PET/CT pattern may be helpful to improve the differentiation from malignant and benign focal breast lesion.

A Study on Manufacturing Method of Standard Void Specimens for Non-destructive Testing in RFI Process and Effect of Void on Mechanical Properties (RFI 공정 부품 비파괴검사용 표준 기공률 시편 제조 방법 및 기공률에 따른 기계적 물성 영향에 대한 연구)

  • Han, Seong-Hyeon;Lee, Jung-Wan;Kim, Jung-Soo;Kim, Young-Min;Kim, Wee-Dae;Um, Moon-Kwang
    • Composites Research
    • /
    • v.32 no.6
    • /
    • pp.395-402
    • /
    • 2019
  • The RFI process is an OoA process that fiber mats and resin films are laminated and cured in a vacuum bag. In case that resin film is insufficient to fill empty space in fibers, it makes void defect in composites and this void decrease mechanical properties of the composites. For this reason, non-destructive testing is usually used to evaluate void of manufactured composites. So, in this study, a manufacturing method of standard void specimens, which are able to be used as references in non-destructive testing, was proposed by controlling resin film thickness in the RFI process. Also, a fiber compaction test was proposed as a method to set the resin film thicknesses depending on target voids of manufacturing panels. The target void panels of 0%, 2%, and 4% were made by the proposed methods, and signal attenuation depending on void was measured by non-destructive testing and image analysis. In addition, voids of specimens for tensile, in-plane, short beam and compressive tests were estimated by signal attenuation, and mechanical properties were evaluated depending on the voids.

레일레이 입사각에서 Schoch 변위가 액체/고체 경계면으로부터 후방산란되는 초음파 에너지에 미치는 영향

  • Lee Jeong-Ki;Kim H. C.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.409-416
    • /
    • 1999
  • 액체/고체 경계면에 레일레이각으로 초음파 pulse를 입사시키면 입사된 에너지의 상당 부분이 고체쪽으로 침투여 표면으로부터 약 1.5 파장 깊이 정도까지 에너지 분포를 가지고 고체 표면을 따라 전파하는 레일레 이파로 전환되며, 이러한 입사각에서는 기하학적인 거울 반사가 일어나지 않고 반사파의 중심이 Schoch 변위만큼 전방으로 이동되고, 또 입사 방향으로 후반 산란되는 초음파의 신호가 급격히 증가하는 현상이 관찰된다. 만일 고체에서 초음파의 감쇠가 산란에 의해 크게 영향을 받고, 레일레이각에서 고체 쪽으로 침투한 에너지의크기를 $E_0$라고 하면, 고체 표면과 표면 근처를 전파하는 레일레이파의 산란파 에너지, $E_S$는 Schoch 변위, ${\Delta}_S$와 산란에 의한 감쇠계수 ${\alpha}_S$에 비례하는 관계가 있음을 이론적으로 구하였다. 입사 방향으로 후방산란되는 초음파는 산란파의 일부이므로 후방산란 초음파 에너지, E_{Bs}도 이와 같은 관계를 가진다. 그러므로, 레일레이각으로 입사된 초음파의 후방산란 에너지, $E_{B_S}$ 산란체(e.g. grain)의 평균 크기, D와 주파수 f와는 레일레이 산란 영역과 Stochastic 산란 영역에 대해 각각 $E_{B_S}\;\propto\;D^{3}f^{3}$$E_{B_S}\;\propto\;D\;f$인 관계를 가지는 것으로 얻어졌다. 이것은 액체/고체 경계면에서 레일레이각으로 입사되어 레일레이파로 전환된 초음파가 다시 액체로 그 에너지를 누설하여 그 산란 영역이 Schoch 변위 내에서 일어나기 때문이며, 이러한 영향에 의해서일반적인 산란에서의 주파수 의존성과는 달리 각 산란 영역에서 그 지수는 1씩 작은 값을 갖는다.향에 따라 음장변화가 크게 다를 것이 예상되므로 이를 규명하기 위해서는 궁극적으로 3차원적인 음장분포 연구가 필요하다. 음향센서를 해저면에 매설할 경우 수충의 수온변화와 센서 주변의 수온변화 사이에는 어느 정도의 시간지연이 존재하게 되므로 이에 대한 영향을 규명하는 것도 센서의 성능예측을 위해서 필요하리라 사료된다.가지는 심부 가스의 개발 성공률을 증가시키기 위하여 심부 가스가 존재하는 지역의 지질학적 부존 환경 및 조성상의 특성과 생산시 소요되는 생산비용을 심도에 따라 분석하고 생산에 수반되는 기술적 문제점들을 정리하였으며 마지막으로 향후 요구되는 연구 분야들을 제시하였다. 또한 참고로 현재 심부 가스의 경우 미국이 연구 개발 측면에서 가장 활발한 활동을 전개하고 있으며 그 결과 다수의 신뢰성 있는 자료들을 확보하고 있으므로 본 논문은 USGS와 Gas Research Institute(GRI)에서 제시한 자료에 근거하였다.ऀĀ耀Ā삱?⨀؀Ā Ā?⨀ጀĀ耀Ā?돀ꢘ?⨀硩?⨀ႎ?⨀?⨀넆돐쁖잖⨀쁖잖⨀/ࠐ?⨀焆덐瀆倆Āⶇ퍟ⶇ퍟ĀĀĀĀ磀鲕좗?⨀肤?⨀⁅Ⴅ?⨀쀃잖⨀䣙熸ጁ↏?⨀

  • PDF

Effect of Cortical Bone on Acoustic Properties of Trabecular Bone in Bovine Femur In Vitro (생체 외 조건의 소 대퇴골에서 해면질골의 음향특성에 대한 피질골의 효과)

  • Hwang, Kyo Seung;Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.181-189
    • /
    • 2013
  • The purpose of the present study is to investigate the effect of cortical bone on acoustic properties of trabecular bone, such as speed of sound (SOS) and normalized broadband ultrasound attenuation (nBUA), in bovine femur in vitro. Twelve trabecular bone samples and three cortical bone plates with thicknesses of 1.00, 1.47, and 2.00 mm were extracted from the proximal end of two bovine femurs. The correlations between acoustic properties and trabecular apparent bone density were also examined before and after attaching a cortical bone plate to the trabecular bone samples. SOS increased linearly with increasing thickness of the cortical plate attached to one side of ultrasonic incidence of the trabecular bone samples, whereas nBUA showed a nonlinear dependence on the thickness of the cortical plate. All the SOS (r = 0.95-0.97) and nBUA (r = 0.53-0.73) measurements with and without the cortical bone plate with various thicknesses were found to exhibit high correlations with the trabecular apparent bone density. These results imply that the acoustic properties measured in the femur with lateral cortical layers in vitro can be useful indices for the prediction of trabecular bone mineral density.

Propagation characteristics of blast-induced vibration to fractured zone (파쇄영역에 따른 발파진동 전파특성)

  • Ahn, Jae-Kwang;Park, Duhee;Park, Ki-Chun;Yoon, Ji Nam
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.959-972
    • /
    • 2017
  • In evaluation of blast-induced vibration, peak particle velocity (PPV) is generally calculated by using attenuation relation curve. Calculated velocity is compared with the value in legal requirements or the standards to determine the stability. Attenuation relation curve varies depending on frequency of test blasting, geological structure of the site and blasting condition, so it is difficult to predict accurately using such an equation. Since PPV is response value from the ground, direct evaluation of the structure is impractical. Because of such a limit, engineers tend to use the commercial numerical analysis program in evaluating the stability of the structure more accurately. However, when simulate the explosion process using existing numerical analysis program, it's never easy to accurately simulate the complex conditions (fracture, crushing, cracks and plastic deformation) around blasting hole. For simulating such a process, the range for modelling will be limited due to the maximum node count and it requires extended calculation time as well. Thus, this study is intended to simulate the elastic energy after fractured zone only, instead of simulating the complex conditions of the rock that results from the blast, and the analysis of response characteristics of the velocity depending on shape and size of the fractured zone was conducted. As a result, difference in velocity and attenuation character were calculated depending on fractured zone around the blast source appeared. Propagation of vibration tended to spread spherically as it is distanced farther from the blast source.

Design of an Excitation System for Simulating Wind-Induced Response and Evaluating Wind-load Resistance Characteristics (건축구조물의 풍하중 구현 및 풍특성 평가를 위한 가진시스템 설계)

  • Park, Eun-Churn;Lee, Sung-Kyung;Min, Kyung-Won;Chun, Lan;Kang, Kyung-Soo;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.769-778
    • /
    • 2007
  • In this paper, excitation systems using linear mass shaker (LMS) and active tuned mass damper (ATMD) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop function are used such that the error between the wind and actuator induced responses is minimized by preventing the actuator from exciting unexpected modal response and initial transient response. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

Dynamic Deformation Characteristics of Joomunjin Standard Sand Using Cyclic Triaxial Test (반복삼축압축시험을 이용한 주문진 표준사의 동적변형특성 분석)

  • Kim, You-Seong;Ko, Hyoung-Woo;Kim, Jae-Hong;Lee, Jin-Gwang
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.53-64
    • /
    • 2012
  • In this study, the modified cyclic triaxial tests with Joomunjin standard sand are performed for dynamic deformation characteristics, such as Young's moduli and damping ratio. The cyclic triaxial test is equipped with Local Displacement Transducer (LDT) on the outside of a cell which has a range from $10^{-4}$ to $10^{-1}$ of shear strains, ${\gamma}$ (%), instead of conventional cyclic triaxial test which has linear variable displacement transducer (LVDT) with low precision. With the small strain control, tests were carried out at various loading rates, void ratios, and effective confining pressures. Based on the test results, such as dynamic deformation characteristics, shear modulus, and damping ratio, it is found that the test can measure more range of medium strains (0.02-0.2%) than results obtained from conventional test (resonant column test). For the medium strain range, dynamic deformation characteristics investigated by the cyclic triaxial test are also different from those predicted by nonlinear model in conventional test.

Magnetic and Microwave Absorbing Properties of M-type Ba-ferrite($BaFe_{12-2X}Ti_XCo_XO_{19}$)with Planar Magnetic Anisortropy (면내 자기이방성을 갖는 M-type Ba-ferrite($BaFe_{12-2X}Ti_XCo_XO_{19}$)의 자기적특성 및 전파흡수특성)

  • 조한신;김성수
    • Resources Recycling
    • /
    • v.7 no.4
    • /
    • pp.22-26
    • /
    • 1998
  • The purpose of this experimenL is to investigate the magnetic anisotropy and microwave absorbing properties in M-type Bat territe (${BaFe}_{12-2X}{A}_{X}{Me}_{X}{O}_{19}$), where $Fe_{3+}$ is substituted by $Ti_{4+}$ in A site and $Co_{2+}$ in Me site. The saturation magnetization (Ms) is linearly decreased with the substitution rate(x) and the coerciviLy (He) is rapidly decreased in accordance with the reduction in t the magnetocrystalline anisotropy For the specimen with x=0.8 and thickness of 2 mm, the reflection loss calculated from the n material constants is less than -10 dB (90% absorption) in the frequency range of 10~16 GHz. The absorption loss is pre이.ctcd t to be more than 20 dElern in the frequency range of 12-16 GHz. The results demonstrate that the Ti-Co substituted M-type Ba-ferrite can be effectively used as a microwave absorber at high frequency range.

  • PDF

Dependences of Ultrasonic Parameters for Osteoporosis Diagnosis on Bone Mineral Density (골다공증 진단을 위한 초음파 변수의 골밀도에 대한 의존성)

  • Hwang, Kyo Seung;Kim, Yoon Mi;Park, Jong Chan;Choi, Min Joo;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.502-508
    • /
    • 2012
  • Quantitative ultrasound technologies for osteoporosis diagnosis measure ultrasonic parameters such as speed of sound(SOS) and normalized broadband ultrasound attenuation(nBUA) in the calcaneus (heel bone). In the present study, the dependences of SOS and nBUA on bone mineral density in the proximal femur with high risk of fracture were investigated by using 20 trabecular bone samples extracted from bovine femurs. SOS and nBUA in the femoral trabecular bone samples were measured by using a transverse transmission method with one matched pair of ultrasonic transducers with a center frequency of 1.0 MHz. SOS and nBUA measured in the 20 trabecular bone samples exhibited high Pearson's correlation coefficients (r) of r = 0.83 and 0.72 with apparent bone density, respectively. The multiple regression analysis with SOS and nBUA as independent variables and apparent bone density as a dependent variable showed that the correlation coefficient r = 0.85 of the multiple linear regression model was higher than those of the simple linear regression model with either parameter SOS or nBUA as an independent variable. These high linear correlations between the ultrasonic parameters and the bone density suggest that the ultrasonic parameters measured in the femur can be useful for predicting the femoral bone mineral density.