• Title/Summary/Keyword: 감소단면

Search Result 1,201, Processing Time 0.029 seconds

An Experimental Study on the Load-settlement Behavior and Settlement-reducing Effect of the Disconnected Piled Raft Foundation (말뚝보강기초의 하중-침하량 거동 및 침하감소효과에 대한 실험적 연구)

  • Lee Yeong-Saeng;Hong Seung-Hyeun
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.4
    • /
    • pp.95-104
    • /
    • 2006
  • For the interests in the economical and safe design of foundation system, the concern on the piled raft or disconnected piled raft foundation system is increasing now. In this study, the behavior and the effects of the disconnected piled raft foundation not studied actively in this country were examined using the triaxial compression tests in place of laboratory model tests. The triaxial test samples were prepared with Jumunjin standard sand and the carbon rods, which simulate the ground soil and piles respectively. After the sample in which carbon rods were arranged was laid inside the triaxial chamber, the confining pressure was applied and then loading test was conducted. To analyze the reinforcing effects of the disconnected piled raft foundation, a few number of tests were carried out by changing the number, the diameter and the length of the model piles. As a result of this study, in the disconnected piled raft foundation system, even though the number of pile is few and the diameter of pile is small, the settlement of the foundation system decreased greatly.

Fire resistance assessment of high strength segment concrete depending on PET fiber amount under fire curves (화재곡선과 PET섬유 혼입량에 따른 고강도 세그먼트 콘크리트의 화재저항성 평가에 대한 연구)

  • Choi, Soon-Wook;Lee, Gyu-Phil;Chang, Soo-Ho;Park, Young-Taek;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.3
    • /
    • pp.311-320
    • /
    • 2014
  • High strength concrete is not only vulnerable to the occurrence of spalling which generates the loss of cross-section in concrete structures but produces faster degradation in its mechanical properties than normal strength concrete in the event of fire. This study aims to evaluate fire resistance of high strength segment concrete with PET fibers mixed to prevent spalling under ISO834 (2hr) and RABT fire curve. As results, the samples without PET fibers show the concrete loss up to the depth of about 8 cm and 9.5 cm from the surface exposed to fire under ISO834 and RABT fire curve respectively. The samples mixed with PET fiber of 0.1% show no spalling under ISO834 fire curve and the spalled thickness of 6.5 cm under RABT fire curve after the fire tests. Finally, the sample mixed with PET fiber of 0.2% shows no spalling under RABT fire curve. The results indicate that the suitable amounts of PET fiber for securing fire resistance performance of this high strength segment concrete are 0.1% under ISO834 fire curve and 0.2% under RABT fire curve. However, even though spalling does not occur, it is necessary to repair the deterioration of concrete up to 4 cm from the surface exposed to fire after fire.

The effect of the changing of the edged shape of rotary blade by wearing on tilling torque requirement (로우터리 날의 마모(磨耗)에 의(依)한 단면형상변화(斷面形狀變化)가 경운소요(耕耘所要)토오크에 미치는 영향(影響))

  • Kim, Soung Rai;Kwon, Soon Goo
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.264-269
    • /
    • 1984
  • The single edged blade was efficient to reduce tilling torque requirement than the double edged blade as previous reported study. This study was carried out to find reducing effects of tilling torque requirement of single edged blade comparing to double edged one in according to wearing by tilling operation. The single and double edged rotary blades were attached on same rotary shaft, and tilling operation was done in hard glass land. The wearing weights of the blade were checked out each 3 hrs tilling operation, at same time, the tilling toruqe requirements were measured with soil bin system in laboratory. The results of the study were summarized as follows: 1. The edged blade shape was not changed during the tilling operation of the rotary blade. The single edged blade was saved 5-10% in the maximum tilling torque and 3-15% in the mean tilling torque than the double edged blade for total durable period. 2. Generally, the tilling torques according to operation were decreased until original shape was maintained, but it was increased after 12 hrs tilling operation, and the tip shape of rotary blade was changed seriously. It is noted that the tip shape of the rotary blade is another factor affecting tilling torque, it should be desirable to study on the rotary blade tip shape to reduce tilling torque requirement after changing its original shape with wearing.

  • PDF

Analysis of Influence for Breach Flow According to Asymmetry of Breach Cross-section (제방붕괴 형상의 비대칭성에 따른 붕괴흐름의 영향 분석)

  • Kim, Sooyoung;Choi, Seo-hye;Lee, Seung Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.557-565
    • /
    • 2016
  • The risk of collapse in hydraulic structures has become more elevated, due to the increased probability and scale of flooding caused by global warming and the resulting abnormal climatic conditions. When a levee, a typical hydraulic structure, breaks, an enormous breach flow pours into the floodplain and much flood damage then occurs. It is important to accurately calculate the breach discharge in order to predict this damage. In this study, the variation of the breach discharge with the asymmetry in the cross-section of the levee breach was analyzed. Through hydraulic experiments, the cross-section of the breach was analyzed during the collapse using the BASD (Bilateral ASymmetry Degree), which was developed to measure the degree of asymmetry. The relationship of the breach discharge was identified using the BASD. Additionally, the variation of the breach flow measured by the BASD was investigated through a 3-D numerical analysis under the same flow conditions as those in the experiment. It was found that the assumption of a rectangular breach cross-section, which is generally used for the estimation of the inundation area, can cause the breach discharge to be overestimated. According to the BASD, the breach flow is decreased by the interference effect in the breach section of the levee. If the breach flow is calculated while considering the BASD in the numerical analysis of the flooding, it is expected that the predicted inundation area can be estimated accurately.

Evaluation of Fire Performance of RC Slabs with Half-Depth Precast Panels (반단면 프리캐스트 패널을 적용한 RC 슬래브의 내화성능 평가)

  • Chung, Chul-Hun;Im, Cho-Rong;Kim, Hyun-Jun;Joo, Sang-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4A
    • /
    • pp.391-398
    • /
    • 2010
  • The fire performance of RC slabs with half-depth precast panel after exposure to the ISO-834 fire standard without loading has been experimentally investigated. During heating, according to the ISO 834 fire curve, concrete spalling was observed for concrete without PP(polypropylene) fibers. No spalling occurred when heating concrete containing PP fibers. The maximum temperature of RC slabs with PP fibers with half-depth precast panel was lower than that of concrete without PP fibers. The ultimate load after cooling of the RC slabs that were not loaded during the furnace tests was evaluated by means of 3 points bending tests. The ultimate load of the RC slabs without PP fibers showed a considerable reduction (around 32.5%) of the ultimate load after cooling if compared with of RC slabs with PP fibers. The ultimate load of the RC slabs with half-depth precast panel with PP fibers is higher than that of a full-depth RC slabs with PP fibers. Also, the addition of PP fibers and the use of half-depth precast panel improve fire resistance.

The Effects of Tunnel Geometrical Characteristics and Canopy Installation on the Ventilation and Fire Propagation (터널의 기하학적 형태 및 캐노피 설치가 터널 환기 및 화재 확산에 미치는 영향 분석)

  • Lee, Chang-Woo;Suh, Ki-Yoon;Kim, Jung-Wook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.325-334
    • /
    • 2006
  • Understanding the airflow characteristics within the canopy structure installed between closely adjacent tunnels either for light adaptation or for protection from snow hazards is required for the normal ventilation as well as safety system design. Grade, horizontal alignment, cross-sectional area and shape are known to substantially influence the fire smoke behavior and their influences raise great concern for the safety design. This paper aims at studying the effects of tunnel geometrical characteristics and canopy installation on the ventilation and fire propagation through CFD analysis. In the case of 145m long canopy, 50% opening ratio is preferred with respect to the airflow pattern and ventilation efficiency. When a 20MW fire occurs in a 1.8km-long tunnel and four 1250mm reversible jet fans are instantly turned on, smoke concentration at 40m downstream of the fire decrease 13% for the upgrade tunnel with 2% gradient and increases 20% for -2% gradient, compared to the standard horizontal tunnel. Backlayering is observed within 45m-long segment toward the entrance in 2% down-graded tunnel. In a rectangular tunnel, there is no significant difference of smoke concentration as well as velocity profile from the standard crown tunnel. Three-laned tunnel shows lower level of both profiles and backlayering is detected up to 50m upstream of the fire, while the risky situation rapidly disappears thereafter.

Development of Online Model for Mean Effective Strain, Roll Force and Area Reduction in Bar Rolling with Three Rolls (콕스밀에서 평균변형율, 압하력, 단면감소율에 대한 수식모델개발)

  • Je S. H.;Hwang S. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.162-165
    • /
    • 2001
  • In industrial practice, caliber design in shape rolling depends on the designer's experience, which in general is obtained through costly trial-and error process. on-line model which is relations of mean effective strain, roll force and area reduction is derived from finite element process simultion in bar rolling with three rolls.

  • PDF

Hydrostatic pressure in the center of wire drawing and extrusion of viscoplastic material (점소성 재료의 인발과 변형역 중심에서의 정수압에 관한 연구)

  • Oh, Hung Kuk
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.3
    • /
    • pp.170-177
    • /
    • 1981
  • 1,200.deg.C에서의 단조철은 점소성을 나타내며 인발과 압출시 변형영역이 구형수렴형태가 됨을 실험을 통하여 나타난다. 이 변형역 모델로부터 평형방정식을 사용하여 평균 압출 및 인발응력과 정수압을 계산해 낸다. 평균 압출 및 임발응력은 상계 해석 방법에 의한 결과와 비교하여 본 연구의 해석방법의 유효성을 타진하고 정수압은 다른 연구자들의 결과와 비교 검토되며 특히 냉간가공의 경우와 비교 검토 된다. 그 외에 마찰계수, 급형각도와 단면감소율의 영향에 대해서도 논의 된다.

Numerical Analysis of Flow Characteristics in the Impeller Channel of a Double Suction Pump (양흡입 펌프 회전차 채널 내부 유동 특성 고찰)

  • 김세진;김윤제
    • Journal of Energy Engineering
    • /
    • v.9 no.2
    • /
    • pp.89-94
    • /
    • 2000
  • 양흡입 펌프 회전차 내부 유동특성을 수치적으로 고찰하였다. 수치계산은 설계점과 2개의 탈설계점에서 이루어졌으며, Patankar에 의해 제시된 SIMPLE 알고리즘을 이용하였다. 설계점에서는 양 회전차 채널 내부에서 대칭 형상을 갖는 이차유동 특성을 발견하였지만, 탈설계점에서는 비대칭 유동특성을 발견하였다. 수치해석 결과로는 유량감소에 따라 양흡입 펌프 회전차 채널내부의 이차유동 특성이 달라진다는 사실을 고찰하였다. 또한 양흡입 펌프 회전차 단면에는 모퉁이 와류가 존재함을 알 수 있었다.

  • PDF

콘크리트 단면의 구멍손실에 따른 압축력 감소에 관한 실험적 연구

  • 손기상
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.191-197
    • /
    • 2000
  • 구조물 진단 등 기술적으로 체크되어 얻어진 결론의 보수보강대책이 새로운 보강용 제품을 사용해야만 하는 것으로 인식되어 가고 있다고 볼 수 있다. 기존의 실시결과가 그렇게 결론으로 제시하고 있기 때문으로 사료된다. 여기에는 해당구조물의 내구년한 에 따라 구조보강방식이 달라져야 함에도, 즉 보다 경제성을 고려한 보강이 되어야 함에도, 즉 보다 경제성을 고려한 보강이 되어야 함에도 적절히 고려되었는가 라는 질문에는 의문을 갖게 된다.(중략)

  • PDF