• Title/Summary/Keyword: 감마 과정

Search Result 166, Processing Time 0.024 seconds

Differences in Thrombolytic Effects in Accordance with Dosing-regimens of Tissue-type Plasminogen Activator in Experimental Pulmonary Embolism (실험적 폐색전증에서 조직형플라스미노겐활성체의 투여방법에 따른 혈전용해효과의 차이)

  • Chung, Hee-Soon;Kim, Ho-Jung;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.123-134
    • /
    • 1993
  • Background: Tissue-type plasminogen activator is a physiologic activator, which has high affinity for fibrin and is activated by fibrin. Because of these properties, t-PA has the potential to induce effective thrombolysis without producing a systemic lytic state. In practice, however, therapeutically efficacious doses of t-PA has been associated with the development of a systemic lytic state. As experience with t-PA has accumulated, it has suggested that the fibrin selectivity is influenced by the dose and duration of t-PA infusion, and many studies have performed in an attempt to optimize the duration of t-PA regimen. Methods: This study was designed to assess the thrombolytic efficacy of t-PA and the differences of two dosing regimens of t-PA (infusion of 1 mg/kg t-PA over 15 or 180 minutes) in a canine model of pulmonary embolism, induced by injection of radioactive autologous blood clots. By continuously counting over both lung fields with a external gamma counter, we correlated rate and extent of pulmonary thrombolysis with corresponding pulmonary hemodynamics in addition to the gas analyses of arterial and mixed venous blood. Results: 1) While total clot lysis was similar ($36.2{\pm}3.3%$ and $39.6{\pm}2.3%$ respectively, p>0.05) when t-PA was infused over 15 or 180 minutes, the rate of lysis during infusion was markedly increased with the shorter infusion ($81.4{\pm}16.8%/hr$ vs $37.3{\pm}2.4%/hr$, p<0.05). 2) The duration of thrombolysis was $63.3{\pm}22.2$ minutes although t-PA was administered over 15 minutes, and it was only $148.5{\pm}14.0$ minutes in case of the infusion over 180 minutes (p<0.05). 3) The increased rate of thrombolysis with the shorter infusion was accompanied by a faster amelioration of cardiopulmonary impairment from pulmonary embolism (p<0.05). Conclusion: It is concluded that the shorter (15 minutes) infusion of t-PA is superior to the longer (180 minutes) infusion when the dose is equal, in consideration of the faster improvement in cardiopulmonary impairment from pulmonary embolism.

  • PDF

Synthesis and Evaluation of $2-[^{18}F]Fluoro-A85380$, a Radioligand for ${\alpha}_4{\beta}_2$ Nicotinic Acetylcholine Receptor Imaging (${\alpha}_4{\beta}_2$ 니코틴성 아세틸콜린 수용체 영상 방사성리간드 $2-[^{18}F]fluoro-A85380$의 합성 및 평가)

  • Ryu, Eun-Kyoung;Choe, Yearn-Seong;Kim, Sang-Eun;Hwang, Sae-Hwan;Paik, Jin-Young;Choi, Yong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.261-270
    • /
    • 2002
  • Purpose: Nicotinic acetylcholine receptors (nAChRs), which mediate excitatory neurotransmission, are known to participate in various neurophysiological functions. Severe losses of nAChRs have been noted in Alzheimer's and Parkinson's diseases. Therefore, noninvasive and quantitative imaging of nAChRs would offer a better understanding on the function of these receptors. In this study, $2-[^{18}F]fluoro-A85380\;([^{18}F]1)$, an ${\alpha}_4{\beta}_2$ nAChRs radioligand, was prepared using one HPLC purification and evaluated in mouse brain, and the results were compared with those in the literature. Materials and Methods: $[^{18}F]1$ was prepared by $[^{18}F]$fluorination of the iodo precursor followed by acidic deprotection and then purified by HPLC. Tissue distribution studies were performed in mouse brain at the indicated time points and the result was expressed as %ID/g. Inhibition studies were also carried out with pretreatment of various ligands. Results: One HPLC purification method gave the desired product in 15-20% radiochemical yield and with high specific activity ($38-55GBq/{\mu}mol$). Tissue distribution studies showed that $[^{18}F]1$ specifically labeled nAChRs in mouse brain with a high thalamus to cerebellum uptake ratio (13.8 at 90 min). Inhibition studios demonstrated selective binding of $[^{18}F]1$ to nAChRs, blocking the uptake of the $[^{18}F]1$ in nAChR-rich legions by selective ligands such as cytisine and nicotine which are well-known nAChRs agonists. Conclusion: This study demonstrated that the $[^{18}F]1$ produced by the method using one HPLC purification gave the results similar to those reported in the literature. Therefore, this synthetic method can be readily applied to the routine preparation of $[^{18}F]1$, a PET radioligand for ${\alpha}_4{\beta}_2$ nAChRs imaging.

Exploring Branch Structure across Branch Orders and Species Using Terrestrial Laser Scanning and Quantitative Structure Model (지상형 라이다와 정량적 구조 모델을 이용한 분기별, 종별 나무의 가지 구조 탐구)

  • Seongwoo Jo;Tackang Yang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.26 no.1
    • /
    • pp.31-52
    • /
    • 2024
  • Considering the significant relationship between a tree's branch structure and physiology, understanding the detailed branch structure is crucial for fields such as species classification, and 3D tree modelling. Recently, terrestrial laser scanning (TLS) and quantitative structure model (QSM) have enhanced the understanding of branch structures by capturing the radius, length, and branching angle of branches. Previous studies examining branch structure with TL S and QSM often relied on mean or median of branch structure parameters, such as the radius ratio and length ratio in parent-child relationships, as representative values. Additionally, these studies have typically focused on the relationship between trunk and the first order branches. This study aims to explore the distribution of branch structure parameters up to the third order in Aesculus hippocastanum, Ginkgo biloba, and Prunus yedoensis. The gamma distribution best represented the distributions of branch structure parameters, as evidenced by the average of Kolmogorov-Smirnov statistics (radius = 0.048; length = 0.061; angle = 0.050). Comparisons of the mode, mean, and median were conducted to determine the most representative measure indicating the central tendency of branch structure parameters. The estimated distributions showed differences between the mode and mean (average of normalized differences for radius ratio = 11.2%; length ratio = 17.0%; branching angle = 8.2%), and between the mode and median (radius ratio = 7.5%; length ratio = 11.5%; branching angle = 5.5%). Comparisons of the estimated distributions across branch orders and species were conducted, showing variations across branch orders and species. This study suggests that examining the estimated distribution of the branch structure parameter offers a more detailed description of branch structure, capturing the central tendencies of branch structure parameters. We also emphasize the importance of examining higher branch orders to gain a comprehensive understanding of branch structure, highlighting the differences across branch orders.

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF