• Title/Summary/Keyword: 감마분석

Search Result 760, Processing Time 0.027 seconds

Analysis of the Distributional Effects of Radioactive Materials on External Gamma Exposure (방사성물질의 분포특성에 따른 외부 감마피폭해석)

  • Han, Moon-Hee;Kim, Eun-Han;Suh, Kyung-Suk;Hwang, Won-Tae;Choi, Young-Gil
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.211-218
    • /
    • 1998
  • The distributional effects of radioactive materials on external gamma exposure have been analyzed. An approximate method for estimating external gamma dose given from an arbitrary distribution of radioactive material has been developed. The minimum gamma exposure given from a point source is shown at 0.07 MeV if the source to receptor distance is shorter than 10 m. But if the receptor to point source distance is longer than 20 m, gamma exposure rate increases monotonously according to the average gamma energy. For the analysis of the effects of volume source, we estimated the gamma dose given from different size of hemisphere in which radioactive materials are distributed uniformly. When the radius of hemisphere is longer than 40 m, external gamma dose rate increases monotonously. The gamma dose rate given from the radioactive materials deposited on the ground shows the minimum value at 0.07 MeV in any case. The analysis shows that external gamma exposure is strongly dependent on the distribution of radioactive materials in the environment and gamma energy.

  • PDF

Application of Immunoassay for the Detection of Gamma-Irradiated Shrimp (감마선 조사된 새우의 검지를 위한 면역분석법의 적용)

  • 이주운;육홍선;조경환;차보숙;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.4
    • /
    • pp.600-604
    • /
    • 2001
  • Immunoassay was used to study the detection method of irradiated shrimp. Sandwich ELISA was formatted with monoclonal antibody (Ab) (M-IgG) and polyclonal Abs (P-IgG) and polyclonal Abs (P-IgG) individually produced against brown shrimp tropomyosin (TPM) as an antigen. When M-IgG was used as a coating Ab to capture TPM, and P-IgG were used as reaction Ab against captured TPM could be detected in the range of 12.5 to 50 $\mu\textrm{g}$/mL. Detected concentrations of TPM from irradiated shrimp decreased dose-dependently, and the concentration of Ag by combination of irradiation with heating or freezing treatments also decreased. This results suggests the possibility for Sandwich ELISA, one of immunological analyses, to be applied for detecting irradiated shrimp.

  • PDF

Effect of Gamma-Irradiation Sterilization on the Creep and Wear of Ultra-High Molecular Weight Polyethylene (감마선 멸균처리가 초고분자량 폴리에틸렌의 크리프와 마모에 미치는 영향)

  • Lee, Kwon-Yong;Lee, Soo-Cheol;Lee, Keun-Ho
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.1-6
    • /
    • 1998
  • 인공관절 라이너에 널리 사용되는 대표적 생체재료인 초고분자량 폴리에틸렌(Ultra-High Molecular Weight Polyethylene)은 체내에 삽입되기 전에 멸균처리를 거쳐야 하며, 가장 보편적인 멸균방법은 감마선을 이용한 멸균처리이다. 그러나, 감마선은 폴리에틸렌의 화학분자 결합구조에 변화를 일으키며, 따라서 물리적, 기계적 물성치에 변화를 야기시킨다. 이는 인공관절 수명을 좌우하는 변형과 마모현상에도 결정적 영향을 줄 것으로 사려된다. 본 연구에서는 감마선 멸균처리가 UHMWPE의 크리프 변형 및 마모에 미치는 영향이 관찰되었고, 그 결과들은 감마선 멸균처리로 야기된 폴리에틸렌의 화학분자 결합구조의 변화(Crystallinity, Oxidation, Crosslinking)와 함께 분석되었다. 압축 제작된 초고분자량 폴리에틸렌 봉(extruded UHMWPE rod)으로부터 원통형의 시평을 제작하여 감마선 멸균처리를 행하고, 압축 크리프 실험과 마모 실험을 실시하여 멸균처리하지 않은 시편을 제작하여 감마선 멸균처리를 행하고, 압축 크리프 실험과 마모 실험을 실시하여 멸균처리하지 않은 시편 사이에는 크리프 복원정도를 제외하고 거의 차이가 없었으나, 반면에 마모의 경우, 감마선 멸균처리된 시편이 멸균처리하지 않은 시편보다 훨씬 적은 마모량을 보였다(p〈0.05). 이것은 crosslinking 증가에 따른 마모 저항력 향상으로 볼 수 있다.

Gamma-irradiated ultra-high molecular weight polyethylene (감마선 멸균처리된 초고분자량 폴리에틸렌)

  • ;;Lee, Keun-Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.227-233
    • /
    • 1998
  • 인공관절 라이너에 널리 사용되는 대표적 생체재료인 초고분자량 폴리에틸렌 (Ultra-High Molecular Weight Polyethylene)은 체내에 삽입되기 전에 멸균처리를 거쳐야 하며, 가장 보편적인 멸균 방법은 감마선을 이용한 멸균처리이다. 그러나, 감마선은 폴리에틸렌의 화학분자 결합구조에 변화를 일으키며, 따라서 물리적, 기계적 물성치에 변화를 야기 사려된다. 이는 인공관절 수명을 좌우하는 변형과 마모현상에도 결정적 영향을 줄 것으로 사려된다. 본 연구에서는 감마선 멸균처리가 UHMWPE의 크리프 변형 및 마모에 미치는 영향이 관찰되었고, 그 결과들은 감마선 멸균처리로 야기된 폴리에틸렌의 화학분자 결합구조의 변화(Crystallinity, Oxidation, Crosslinking)와 함께 분석되었다. 압출 제작된 초고분자량 폴리에틸렌 봉(extruded UHMWPE rod)으로부터 원통형의 시편을 제작하여 감마선 멸균처리를 행하고, 압축 크리프 실험과 마모 실험을 실시하여 멸균처리 하지 않은 시편의 결과와 비교하였다. 크리프 변형의 경우, 감마선 멸균처리 된 시편과 멸균처리 하지 않는 시편 사이에는 크리프 복원정도를 제외하고 거의 차이가 없었으나, 반면에 마모의 경우, 감마선 멸균처리 된 시편이 멸균처리 하지 않은 시편보다 훨씬 적은 마모량을 보였다 (p<0.05). 이것은 crosslinking 증가에 따른 마모 저항력 향상으로 볼 수 있다.

  • PDF

The study of collimator and radiation shield for the detection of the gamma-ray distribution (감마선 분포탐지를 위한 조사구 및 차폐체에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.944-945
    • /
    • 2016
  • Gamma-ray Detector for gamma-ray imaging device is composed of a shielding body for shielding gamma-rays incident from the radiation source. Distribution of the gamma ray can be represented by the distribution information on the direction in which the detecting section and the signal through the incident hole of collimator. The role of the shield is important because all signals should be treated as noise except for the signal from the incident hole.In this paper In this paper, we have produced a compact, lightweight and Collimator shield by changing the structure and physical properties with respect to the collimator and shielding of lead-based gamma-ray detectors. And we analyzed the shielding effectiveness relative to the incident gamma ray sphere measured signal value through the gamma irradiation test facility. The results confirmed that the production and Collimator shielding the imaging device Implementing more efficient to implement.

  • PDF

The Analysis of Driving Workload and Gamma Waves on Curved Sections in Expressway (고속도로 커브구간에서 운전자의 운전부하와 감마파 특성분석에 관한 연구)

  • KANG, Xuejian;NAMGUNG, Moon;KIM, Won Chul;WANG, Weijie
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.6
    • /
    • pp.560-569
    • /
    • 2016
  • Previous studies show that driver mental workload plays a significant role in the occurrence of traffic accidents. This study also analyzes driving workload under different road conditions especially with the brain wave data collected by a driving simulator. We use a logistic regression model to explain the relationship between driving workload and gamma brain waves. The results show that beta band of brain waves becomes broader with more curved sections while alpha band and gamma band become narrower. Since driving workload is negatively correlated with gamma band, it can be concluded that driving condition with less curved section is beneficial for reducing driving stress and increasing driving comfort.

Development of a simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector (HPGe 검출기를 사용한 감마분광분석계의 점검선원 개발)

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.119-123
    • /
    • 2013
  • A simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector was developed. The check source consists of radium-riched soil which was ground in size of less than 0.154mm and contained in air tight cylinderical vial, and provides photons with 12 distinct energies. The spectra of the check source were measured once a month during one year, analyzed the charactreictics of their peaks. When the gamma spectrometry system was in normal state, the areas and FWHMs of the gamma rays with more than 3% gamma emission rate in radium and its decay products was constant within standard deviation 2% and 3%, respectively, except 77 keV peak. And it was found that this check source can play a sufficient role to check the integrity of a gamma spectrometry system using 10 peaks in the range of 77 to 2202 keV.

울진 2호기 5주기 저출력 노물리 시험에서의 감마 Background 의 영향 분석

  • 송재웅;김용래
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.197-205
    • /
    • 1996
  • 울진 2호기 5주기 노물리 시험 결과 기준 제어군의 제어능과 기준 제어군 삽입 전후의 붕소 농도의 차이의 비로 정의되는 평균 붕소능의 측정 결과가 제한치를 위배하였다. 이것은 노물리 시험시 사용하는 노외 계측기가 비보상형 전리함이기 때문에 중성자속 준위가 낮을 때 감마 background 에 의한 영향이 커지며, 이런 경우에 발생될 수 있는 현상으로 판명되었다. 따라서 본 연구에서는 이러한 감마 background로 인한 반응도 증가 현상을 분석하기 위해 점 동특성 방정식을 수치 해석적으로 풀고 이로부터 감마 background가 없을 때의 기준 제어군 제어능 측정 시험을 모사 계산하였다. 이러한 방법으로 계산한 결과, 기준 제어군의 예상 측정제어능이 실제 측정치보다 약 6%증가하였으며 이 값을 사용하여 평균 붕소능을 계산한 바에 의하면 그 제한치를 만족하는 것으로 평가되었다.

  • PDF