• Title/Summary/Keyword: 간접측정법

Search Result 213, Processing Time 0.031 seconds

The Impact of the Media Law Reform on the Media/Contents Firms' Market Value: Event Study Analysis (미디어법 개정이 미디어/콘텐츠기업가치에 미치는 영향분석: 사건연구의 활용)

  • Park, Jongsur
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.9
    • /
    • pp.411-422
    • /
    • 2016
  • The Media Law including Newspaper Law, Broadcasting Law and Internet Multimedia Law has been reformed in 2009. The main purpose of the reform was to allow media firms to gain a global competitive edge by opening doors to more investments that were nonexistent due to regulatory barriers. Also it aimed to contribute to an increase of employment in the media industry. This paper analyzes the impact that the Media Law reform of 2009 had on many media/contents company's future value by tracking abnormal returns gained during the period of the reform. The analysis with the capital market data of fifteen firms over a one-year period provided evidence that the new law has had an effect on the related firms' future value; however, the impact was shown to not be as significant in the long-term. This study has the significance in that it showed that the impact of the reform was not overall to the industry but given to the limited number of media company and confirmed the relatively strong effect of the unexpected events.

Measurement and Assessment on the Shaft Power Measurement of Diesel Engine using Strain Gauge in Marine Vessel (선박에서 스트레인 게이지를 이용한 디젤엔진의 축 동력 측정과 평가)

  • Lee, Don-Chool;Song, Myong-Ho;Kim, Sang-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1152-1161
    • /
    • 2009
  • The power measurement of main propulsion system on the new vessels can be classified with the direct method acquired from the shaft's strain using strain gauge and the indirect method converted and summed from all of cylinders combustion pressure using mechanical or electrical pickup device during the sea trial. This power is fluctuated by external factors which was influenced by various sea motions with long time interval and by internal factors which was influenced by varying torques of torsional vibration and bending moment, due to mis-aligned shaft and whirling vibration with short time interval. In this paper, the statistical analysis method for the shaft power measurement and assessment using strain gauge in marine vessels are introduced. And these are identified by the low speed two stroke diesel engine model and four stroke medium speed diesel engine model including reduction gear.

Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test (표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가)

  • 서범경;이근우;임난주;박진호;한명진
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • The smear media possible to sampling and radiation detection was prepared and evaluated for the surface contamination using indirect method. The films were made by impregnating Cerium Activated Yttrium Silicate (CAYS) in a polysulfone membrane. The membranes used solution as a dimethylformamide (DMF) and methylene chloride (MC), polysulfone as a polymer matrix and CAYS as a inorganic scintillator. The proximity membranes were prepared with single- and double-layered structure. The solidified methods were immersion to the nonsolvent bath such at water and ethanol and solvent evaporation. The measurement of the photon produced by interaction with radiation and inorganic scintillator used a photomultiflier tube (PMT), amplifier, and counter. In the comparison with the low background alpha/beta counter, the counter rate using inorganic scintillator proximity membrane for the $\^$14/C surface contamination was about 50%. Also. the $^3$H counting results revealed that the prepared membranes were efficient to monitor the surface contaminated with the low energy be-ray emitter nuclides.

Biomechanical Effect of Forearm Flexor Muscles depending on Handle Sizes (수공구 손잡이 형태에 따른 생체역학적 영향도 분석)

  • Park, Shi-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.2
    • /
    • pp.41-48
    • /
    • 2012
  • 수공구 사용시 과도한 힘은 작업성 근골격계 질환을 일으킬 수 있는 주요 원인중 하나이다. 이와 관련하여, 수공구 파지시 인체 내부에 부과되는 근력과 외적으로 작용된 힘 간의 비율을 이해하는 것이 중요하며, 이는 근육에 부과되는 과도한 힘을 최소화 시키고, 작업에 필요한 힘의 효율성을 극대화 시키는데 필수적이라 할 수 있다. 이러한 비율과 관련하여 많은 연구가 되어 왔으나, 대부분 수리적 인체역학적 모델과 같은 간접적 추정 방법에 의거하고 있는 실정이다. 이러한 인체역학적 모델을 검증하고 개선하기 위하여 해부용 팔 (cadaver)을 활용한 직접적인 근력과 악력 측정이 필수적이다. 본 연구에서는 이러한 해부용 팔을 이용하여 상지 굴근(hand flexor)을 자동으로 제어하고 근력과 함께 악력을 측정할 수 있는 Hand Motion Simulator를 개발하고, 이를 통하여 다양한 사이즈의 손잡이 파지시 요구되는 근력과 외적으로 적용된 악력을 비교함으로써 수공구 손잡이 사이즈에 따른 근력의 효율성에 대하여 측정을 해 보았다. 또한, 적용된 굴근 (FDP & FDS) 간의 힘 비율에 따른 파지법의 차이를 조사해 보았다. 내부에 주어진 근력은 외부로 작용된 악력보다 5.3배 높은 부하가 작용하였으며 이러한 수공구 손잡이 파지시 힘의 효율성 역시 FDP 와 FDS 간의 비율이 3:2 였을 때, 그리고 손잡이 크기가 작을수록 높은 결과를 보였다. 반대로 손잡이의 크기가 커질수록 힘의 효율성은 저하되었다. 또한, 손가락 관절 각도의 경우 FDP와 FDS간의 비율에 따라 상이한 자세를 나타내었다. FDP 굴근의 비율이 높을 경우 손가락 끝마디 관절 (DIP) 의 굴곡을 보였으며, FDS 굴근 비율이 높을 경우 손가락 두 번째 관절(PIP)의 굴곡을 보였다. 본 연구를 통한 결과는 추후 상지작업자에 대한 근골격계 질환 예방 기준안 마련 및 수공구 설계를 위한 기초자료로 활용이 가능할 것으로 보인다.

System-level measurements based force identification (시스템 레벨의 응답을 이용한 가진력 추정)

  • Seung-Hwan Do;Min-Ho Pak;Seunghun Baek
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.5
    • /
    • pp.547-556
    • /
    • 2024
  • To predict the response of dynamic systems through analysis, it is essential to accurately estimate the system's stiffness and apply it to the analytical model. However, directly measuring the stiffness of actual mechanical systems is challenging. Many existing methods involve decomposing the system into components, obtaining the frequency response for each component, and then reassembling them to determine the overall system response. This process can be cumbersome, and variations in coupling conditions between components can increase errors. In this study, a new method is proposed to estimate system stiffness indirectly through experiments without decomposing the system into components. The approach combines response measurements from the entire system with a theoretical model for analysis. It simplifies the stiffness source into a lumped mass model and constructs the equations of motion based on a reduced-order model of the entire system. Subsequently, the stiffness is quantified by calculating the interface forces between the stiffness source and the receiver using vibration measurements obtained at arbitrary positions through experimentation.

Serodiagnosis of cysticercosis by ELISA-inhibition test using monoclonal antibodies (단세포군항체를 이용한 효소면역억제측정 법에 의한 유구낭미충증의 혈청학적 진단)

  • 용태순;여인석
    • Parasites, Hosts and Diseases
    • /
    • v.31 no.2
    • /
    • pp.149-156
    • /
    • 1993
  • Monoclonal antibodies (Mabs) were produced against crude scolex extract of T solium metacestodes, and applied to ELISA-inhibition test for improving the specificity of serodiagnosis of human cysticercosis. Four hybridomas secreting species-specific anti- cysticercal Mabs (Cya-1, Cya-7, Cya-28 and Cya-31) were selected. Each Mab reacted on antigenic components of 25.5 kDa (Cya-1), 28 kDa (rcya-7), 87.5 kDa (Cya-281), and 12.5 kDa (Cya-31). IFA showed that Cya-1 was located at the calcium corpuscles, and Cya-7 at the loose connective tissue of T soLium metacestode scolex. Cya-28 and Cya-31 reacted on the tegument of the scolex. By conventional ELISA, 23 out of 28 (82.1%) cysticercosis patients were found serologically positive, but 1 out of 9 (11.1%) sparganosls cases and 6 out of 31 (19.4%) paragonlmiasis cases showed false positives. By ELISA-Inhibition test using species-specific anti-cysticercal Mab Cya-7, 19 out of 28 (67.9%) cystlcercosis cases were found serologically positive, but there were no false positives In other parasitic infections.

  • PDF

Measuring Willingness to Pay for PM10 Risk Reductions: Evidence from Averting Expenditures for Anti-PM10 Masks and Air Purifiers (미세먼지 건강위험 감소에 대한 지불의사 측정: 마스크 착용과 공기청정기 사용에 따른 회피비용을 중심으로)

  • Eom, Young Sook;Kim, Jin Ok;Ahn, So Eun
    • Environmental and Resource Economics Review
    • /
    • v.28 no.3
    • /
    • pp.355-383
    • /
    • 2019
  • This study is to investigate whether averting costs for wearing $anti-PM_{10}$ masks and using air purifiers at home to reduce exposure from $PM_{10}$ are influenced by subjective risk perceptions and/or objective $PM_{10}$ concentration levels, whose estimates will be used to measure the willingness to pay for $PM_{10}$ risk reduction. An empirical analysis was conducted on a sample of 1,224 respondents who participated in the web-based survey in the late October of 2017. As we reflect the potential endogeniety bias in the estimation of averting cost functions of using air purifiers, the coefficients of risk perception were differed by 6~7 times. Respondents. subjective risk perceptions were influenced by individuals' knowledge, attitudes and demographic variables, as well as the levels of $PM_{10}$ concentrations in their residential region. The marginal willingness to pay for risk reductions at the mean levels of their risk perceptions were measured at 1,000 won per month from wearing $anti-PM_{10}$ masks and 6,000 won for using air purifiers respectively.

Study for the Indirect Measuring Method of Operational Force in Surgical Robot Instrument (복강경 수술용 로봇 인스트루먼트의 간접적 작동력 측정법에 관한 연구)

  • Kim, Chi-Yen;Lee, Min-Cheol;Lee, Tae-Kyung;Choi, Seung-Wook;Park, Min-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.840-845
    • /
    • 2010
  • This paper proposes the method indirectly measuring the operating force of the end-effect tip of surgical robot instrument which conducts the surgical operation in the body on behalf of the surgeon's hand. Due to the size and safety obligation to the surgical robot instrument, it is difficult to measure the operation force of its tip like grasping force. However the instrument is driven by cable-pulley torque transmission mechanism and when some force is occurred at the tip, then the reaction force appears on the cable as additional tension. Based on this phenomenon, this paper proposes a method to estimate the operating force from measuring reaction force against the driving motor by using a loadcell. And it induces mathematical equation to calculate the force from loadcell by approaching the modulus of elasticity to high order polynomial. And this paper proves the validity of proposed mechanism by experimental test.

Diagnosis of State Of Health(SOH) for Battery Management System(BMS) (축전지 관리시스템(BMS)을 위한 건강상태(SOH) 진단방법)

  • Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.558-562
    • /
    • 2006
  • Although secondary batteries, called rechargeable batteries, are very important energy elements in modern society, their application is hindered by the typical nonlinear and irreversible characteristics. Precise monitoring of the state of health(SOH) for each battery cell on line is crucial for stable operation and proper management of them. This paper proposes diagnostic method of the SOH for a battery cell on line without interruption on its operation nor bad effect on its life. This paper practically diagnoses on 120 industrial batteries and provides some guide lines to decide whether to exchange or not.

Performance Evaluation of NDE Methods in Condition Assessment of Structural Elements (구조물 진단에 있어 비파괴 시험법의 성능평가)

  • Shim, Hyung Seop;Kang, Bo Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.167-175
    • /
    • 2007
  • The relations between data from test methods and conditions in structural elements are considered. NDE(Nondestructive Evaluation) methods are joint application of a test and a basis for interpretation of data obtained in the test. Correct assessments of conditions of elements depend on the inaccuracy and variability in the test data and on the uncertainty of correlations between attributes(what is measured) and conditions(what is sought in the inspection). A full description of the performance of NDE methods considers the relation of test data to condition of elements. The quality of the test data itself is important, but equally important is the interpretation that occurs after the test. To make the decision of the performance of NDE methods, this paper presents mathematical basis to measure the reliability of NDE methods.