• Title/Summary/Keyword: 간섭측정

Search Result 1,448, Processing Time 0.027 seconds

State-of-the-Art of the Surface Metrology using Optical Phase Measuring Interferometry (광위상간섭을 이용한 표면측정 기술현황)

  • 김승우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.182-187
    • /
    • 2000
  • 빛은 공간상에서 전파되는 특성상 전자기파(electromagnetic wave)로 규정될 수 있다. 빛의 파동성은 여러 형태의 간섭을 유발한다. 이중 정밀 길이측정에는 광위상간섭(phase measuring interferometry)의 원리가 대표적으로 이용된다. 그림1은 광위상간섭의 기본원리를 Michelson 광학계를 이용하여 설명하고 있다. 하나의 동일한 광원으로부터 출발된 광속(optical beam)은 광분할기(beam splitter)에 의해 두 개로 별도 광속으로 분활 된다. (중략)

  • PDF

Measurement of thermooptic coefficient by electronic speckle pattern interferometer (전자 스펙클 무늬 간섭계를 이용한 열광학계수 측정)

  • 윤재선
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.101-104
    • /
    • 1992
  • One of coefficients showing the degree of thermal effects is the thermooptic coefficient. It is the ratio of the refractive index change versus the change of temperture and was already measured by other general interferometric method. In this research, an optical system with the electronic speckle pattern interferometer complementing faults of the general interferometer was developed and its potentiality was validated experimentally.

  • PDF

Analysis of the Optical Measurement Error Induced by Vibration of the Optical Measurement Tower for Large Mirrors (대구경 반사경 광학측정용 타워의 진동에 의한 광학측정오차 분석)

  • Kang, Pilseong;Kim, Ohgan;Ahn, Hee Kyung;Yang, Ho-Soon
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.281-289
    • /
    • 2017
  • In the present research, the optical measurement error induced by vibration of the optical measurement tower for large mirrors at KRISS (Korea Research Institute of Standards and Science) is investigated. The vibrations of the tower structure, the interferometer, and the null lens are measured while the surface errors of the 600-mm-diameter on-axis aspheric mirror are measuring, under various environmental conditions. The increase of surface error induced by alignment error with respect to vibration is analyzed. As a result, the interferometer and the null lens, which are located on the top of the tower, are highly sensitive to vibration. Additionally, the surface error of the mirror is strongly increased when the vibration directions of the interferometer and the null lens are different. To reduce the alignment error and the surface error induced by vibration, the tower structure should be improved, to be insensitive to low-frequency vibration. Alternatively, optical measuring under stable conditions by vibration monitoring can improve the reliability of the surface error measurement.

A study on the measurement of stress intensity factor by laser interference (레이저 간섭법에 의한 응력확대계수 측정에 관한 연구)

  • 최상인;최선호;황재석;권재도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.806-812
    • /
    • 1988
  • When laser interference method is used to measure stress intensity factor with experiment, crack molded from teflon crack molding method is better than the crack manufactured through fatigue test. It is known that center distance between two indentations which is best for detecting the laser interference fringe order is about 80.mu.m with photodetector used in this research. Errors with measurement of stress intensity factor through laser interference are between 2% and 11%, therefore, experimental process and method developed in this research can be used with obtaining the more precision experimental data for stress intensity factors.

Measurement of the Thermal Behavior of a Nd:YAG Laser Rod by Analyzing Interference Fringe from a He-Ne Probe Beam (He-Ne 레이저 탐사광의 간섭효과를 이용한 Nd:YAG 레이저봉의 온도측정)

  • 김광석;공홍진;김덕현;김철중
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.204-209
    • /
    • 1990
  • The temperature variation at a laser rod center induced by high repetetion rate pumping was measured by counting the number of inteference frigne shift and found to be consistent with the theoretical value obtained from heat diffusion equation. The spatial homogeneity and energy transfer rate of flashlamp pumping by the single elliptical reflector plated with gold were evaluated by measuring interference fringes oever the cross section of a Nd:YAG laser rod.

  • PDF

Low Coherence Interferometer for Measurement of Path Length Errors in Arrayed-Waveguide Grating (Arrayed-Waveguide Grating의 경로 오차 측정을 위한 저 간섭 광원 간섭계)

  • Song, Young-Ki;Heo, Nam-Chun;Chung, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.539-546
    • /
    • 2004
  • An improved low coherence interferometer system and a new analysis method for the accurate measurement of the optical path difference error of an AWG (Arrayed-Waveguide Grating) are described. The use of software simplifies the experimental setup by eliminating the hardware (clock generator). In addition, the actual distances between the peak positions of the adjacent interference signals are calculated using interpolation methods. The wavelength transmission characteristics of the AWG are calculated assuming the measured phase errors. The calculated AWG characteristic is quite similar to the actual measurement result, confirming accuracy of the proposed measurement setup.

Phase noise filtering in interferometer using the characteristic of SPPCM of BaTiO3 (BaTiO3의 SPPCM 특성을 이용한 간섭계의 위상 잡음 제거)

  • Han, Jeong Yeop;Kim, Seong Wan;Kim, Jong Yun;Park, Se Jun;Kim, Cheol Su;Kim, Su Jung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.36-36
    • /
    • 2001
  • 간섭계를 이용하는 작업에서 가장 중요한 요구사항은 간섭 필드의 안정성을 높게 유지하는 것이며 이는 안정된 간섭패턴을 이용한 측정에 있어서 정밀성을 확보해 준다. 그러나 진동과 같은 위상잡음에 의해 안정성을 유지하기 힘들다. 본 논문에서는 BaTiO₃의 SPPCM 특성을 이용하여 마흐젠더 간섭계와 같은 전통적인 간섭계 측정시 발생 가능한 위상잡음의 영향을 줄여 안정된 간섭 패턴 확보 방법을 제안하였다. 또한 BaTiO₃로 빛을 입사시킬 때 구형렌즈를 기울여 입사빔을 원형이 아닌 타원형으로 입사시켜 원형 입사의 경우에 비해 SPPCM의 응답시간과 반사율을 개선하였다. 그리고 실험을 통해 결과를 확인하였다.

Analysis of Received Field Strength for PCS service using proposed Interference Analyzer and Measurement Data (몬테카를로 간섭분석기와 PCS 실측 수신 전계강도의 비교분석 연구)

  • 신경철;이일근;박승규;이정규;이정훈
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.81-84
    • /
    • 2000
  • 본 논문은 국제통신연합 전파통신분야(ITU-R)의 간섭분석기의 표준으로 채택한 몬테카를로 기법을 기초로 하여 개발된 간섭분석기를 이용하여 개인 통신 서비스(Personal Communication Service)의 도심지 환경에서 수신 전계강도를 예측하였다. 또한 실제로 측정된 수신 전계강도와 비교하여 간섭분석기의 신뢰도를 검증하였다. 개발된 간섭분석기는 한국 지형에 적합한 전파 전파 모델인 수정된 하타(Modified Hata) 모델을 적용하여 개발하였고, 국내 PCS(IS-95A) 서비스 환경과 규격을 고려한 시나리오를 설정하여 모의 실험을 수행하였다. 실험 결과 간섭 분석기와 실제 측정 수신 전계 강도 사이에는 0.03dBm의 평균오차를 가지며, 이는 간섭분석기를 통해 얻어진 결과가 실제와 매우 유사함을 보여준다.

  • PDF

Fiber Optic AC Voltage Sensor Using Fringe Counting (간섭무늬의 변화갯수 측정을 이용한 광섬유 교류전압센서)

  • 김봉규;김병윤;김만식
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.158-165
    • /
    • 1994
  • A fiber optic voltage sensor is demonstrated with a new signal processing scheme that displays the magnitude and the waveform of applied voltage with immunity from the signal frequency change. The sensor is based on a Mach-Zehnder interferometer with a PZT phase modulator as a sensing element. We observed a linear relationship between applied voltage and the number of fringe shift during a half cycle of the ac signal. The temperature dependence of the sensor output is experimentally evaluated over the temperature range from $-20^{\circ}C to 80^{\circ}C$. It is demonstrated that the detrimental polarization modulation effect can be overcome by using polarization maintaining fibers or a half-wave plate. plate.

  • PDF

Fizeau interferometry using angled end-face optical fiber source (경사 단면 광섬유 광원을 이용한 피조 간섭계)

  • 김학용;김병창;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.334-338
    • /
    • 2001
  • A Fizeau interferometer without beam splitter was constructed. Single-mode optical fiber was used as a spherical wave source and the face of fiber end was polished and coated to be a reflecting surface. The reflecting surface was angled so that interference fringe could be detected by CCD camera. Beam splitter in front of a spherical wave source could distort the wave front and that was one of the component error sources. With the proposed configuration there was no need to place beam splitter in the system. Improvement of phase measuring accuracy was evaluated quantitatively by comparing the result of this setup with that of a conventional Fizeau interferometer. Wave front of the angled end-face optical fiber source was also measured to verify its sphericity by PS/PDI (Phase Shifting/Point Diffraction Interferometer). The principle of this technique was presented and the experimental results and its applications were discussed. ussed.

  • PDF