• Title/Summary/Keyword: 간극통과성

Search Result 18, Processing Time 0.033 seconds

The Behavior of Fresh Concrete to Pass between Bars (굳지 않은 콘크리트의 간극통과거동)

  • 오상균
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.97-102
    • /
    • 2002
  • The ability to pass between bars is one of the most important performance of self-compacting concrete or high-flowability concrete since it determines the final filling capacity which influences the strength and durability of hardened concrete in structure. Therefore it has been evaluated by many researchers using different kinds of testing apparatuses. The assessments of passing ability, however, differ largely according to the style, the dimension and the criteria in apparatuses, and the value obtained from one apparatus cannot be converted those of the others. There needs a rheological approach to the better understanding of the passing behavior of fresh concrete between reinforcing bars, where the flow velocity of concrete becomes slow and the blockade sometimes occurs due to the interference between aggregates and reinforcing bars. Experimental works were conducted to clarity the effects of the clearance between reinforcing bars, the volume of aggregate and the rheological properties of matrix on the behavior from the rheological point view and showed the rational mix proportioning of concrete.

  • PDF

Effect of Maximum Size of Coarse Aggregate on Passing Performance of Concrete between Reinforcing Bars (굵은골재의 최대치수가 콘크리트의 간극통과성에 미치는 영향)

  • Baik Dae-Hyun;Yoon Seob;Kim Jung-Bin;Lee Seong-Yeun;Yoon Ki-Won;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.77-80
    • /
    • 2006
  • This study investigated filling performance of concrete which can pass between reinforcing bars and be fully filled, and examined fundamental properties of concrete which is before or after hardened state, in response to maximum size of coarse aggregate. This study was also originally intended to find out one of the method that can improve concrete quality, using crushed coarse aggregate. Test showed that passing ratio of concrete decreased as aggregate site increased and as space between reinforcing bars decreased. In addition concrete using bigger size of coarse aggregate exhibited slightly higher compressive strength and showed lower length change ratio of drying shrinkage.

  • PDF

Flowing Characteristic of High Flowing Self-Compacting Concrete with mixing Steel Fiber (강섬유 혼입에 따른 고유동 자기충전 콘크리트의 유동특성)

  • Choi, Yun-Wang;Choi, Wook;Kim, Gi-Beom;Jeong, Jae-Gwon;Ahn, Tae-Ho;Eom, Joo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.461-464
    • /
    • 2008
  • This study is compactability and Passing ability to get to know the flowing characteristic of high flowing self-compacting concrete with mixing steel fiber of various size and diameter. After flowing test, size and diameter are getting longer, flowing performance is getting lower. It meets the standard of combined high flowing self-compacting concrete of JSCE 2 grade and passing performance from ASTM C 1621. Through this study, it can be possible to be applied in site of HSCC with mixing steel fiber.

  • PDF

An Experimental Study on Mortar to Apply Building Structure (건축물 구조체에 적용가능한 모르타르에 관한 실험적 연구)

  • Kwon, Mi-Ok;Yoon, Ki-Hyun;Jung, Kang-Sik;Kim, Gang-Ki;Paik, Min-Su;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.413-416
    • /
    • 2008
  • The concrete used most in construction materials. There is an overcrowded iron dimensions use of the concrete at time of the other concrete theory on the reinforcing rod back which did congestion and compares it with this, and there are more few dimensions of the aggregate than concrete, and quantity of aggregate passage is superior in mortar than concrete. If a volume rate of the aggregate writes mortar than concrete against this, therefore, unit amount increases, and quantity of paste increases and quantity of dry shrinkage than increase concrete. However, I let I regulate lay priest distribution of the aggregate, and the results rates increase and reduce unit amount and decrease quantity of dry shrinkage, and separation resistance and the gap passage characteristics are judged because it can be it in a substitute document of very superior concrete. I came to carry out the study that I watched to let I was useful a little more and do the improvement repair of a become building wall body, a basement pillar and repair reinforcement of the assistant in the reinforcing rod back, the old age when I made congestion here. I regulated lay priest distribution of the aggregate in the study and regulated substitution rate of the aggregate (40%, 50%, 60%) and divided W/C 30%, 40% standards and produced mortar and I compared quantity of air by this, slump, compression robbery and showed it this time.

  • PDF

Single Channel Analysis of Xenopus Connexin 38 Hemichannel (제노푸스 Cx38 세포막채널의 단일채널분석)

  • Cheon, Mi-Saek;Oh, Seung-Hoon
    • Journal of Life Science
    • /
    • v.17 no.11
    • /
    • pp.1517-1522
    • /
    • 2007
  • Gap junction channels formed by two adjacent cells allow the passage of small molecules up to ${\sim}\;1\;kDa$ between them. Hemichannel (connexon or half of gap junction) also behaves as a membrane channel like sodium or potassium channels in a single cell membrane. Among 26 types of connexin (Cx), $Cx32^*43E1$ (a chimera in which the first extracellular loop of Cx32 has been replaced with that of Cx43), Cx38, Cx46, and Cx50 form functional hemichannels as well as gap junction channels. Although it is known that Xenopus oocytes express endogenous connexin 38 (Cx38), its biophysical characteristics at single channel level are poorly understood. In this study, we performed single channel recordings from single Xenopus oocytes to acquire the biophysical properties of Cx38 including voltage-dependent gating and permeation (conductance and selectivity). The voltage-dependent fast and slow gatings of Cx38 hemichannel are distinct. Fast gating events occur at positive potentials and their open probabilities are low. In contrast, slow gatings dominate at negative potentials with high open probabilites. Based on hi-ionic experiments, Cx38 hemichannel is anion-selective. It will be interesting to test whether charged amino acid residues in the amino terminus of Cx38 are responsible for voltage gatings and permeation.

A Numerical Study on the Correlation between Joint Roughness and Hydraulic Characteristics (절리면 거칠기와 수리특성의 상관성에 관한 수치해석적 연구)

  • Lee, Seung-Joong;Kim, Byung-Ryeol;Choi, Sung-Oong
    • Tunnel and Underground Space
    • /
    • v.24 no.2
    • /
    • pp.176-186
    • /
    • 2014
  • Roughness, aperture and filling material of rock joint are widely considered to affect the hydraulic characteristics of joint. Among these factors, in this study, the joint roughness was examined with artificial joint profiles generated by Monte Carlo simulating on the original profiles suggested by Barton and Choubey(1977). Original profiles and revised profiles were combined to establish flow channel models, in which the hydraulic characteristics were analyzed numerically on the basis of minimum aperture changes and flow channel shapes. Maximum flow rate was identified at the growing point of flow area after passing through minimum aperture generated by the two profiles, and it was resulted that maximum flow rate is inversely proportional to minimum aperture. Maximum flow rate per unit area showed different values because flow channel shapes and minimum aperture locations are different in each model. In flow channel, mechanical aperture showed approximately 1.07 ~ 3.00 times larger than hydraulic aperture. In this study, mechanical and hydraulic aperture were concluded to be closely related to $A_i$ value, and their relations can be denoted by $e_m=0.519A^{0.7169_i}$ and $e_h=0.6182A^{0.239}_i$, respectively.

Basic Research of Self Compacting Concrete Using Alkali-Activated Slag Binder (알칼리 활성 슬래그 결합재를 이용한 자기충전 콘크리트의 기초 연구)

  • Song, Keum-Il;Shin, Gyeong-Sik;Gong, Min-Ho;Song, Jin-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.657-665
    • /
    • 2013
  • The purpose of this study is the basic research of self-compacting concrete using Alkali-Activated Slag (AAS) binder in order to emphasize the durability of structures and facilitate casting the fresh concrete in field. The AAS binder emitted low carbon dioxide ($CO_2$) is eco friendly material of new concept because AAS products not only emit little $CO_2$ during production but also reuse the industrial by-products such as ground granulated blast-furnace slag (GGBS) of the steel mill. Until now, almost of domestic and foreign research are using Ordinary Portland Cement (OPC) for self-compacting concrete, and also, nonexistent research about AAS. The self-compacting concrete must get the performance of flowability, segregation resistance, filling and passing ability. Nine concrete mixes were prepared with the main parameter of unit amount of binder (400, 500, 600 $kg/m^3$) and 3 types of water-binder (W/B) ratio. The results of test were that fresh concretes were satisfied with flowability, segregation resistance, and filling ability of JSCE. But the passing ability was not meet the criteria of EFNARC because of higher viscosity of AAS paste than OPC. This high viscosity of AAS paste enables the manufacturing of self compacting concrete, segregation of which does not occur without the using of viscosity agent. It is necessary that the development of high fluidity AAS binders of higher strength and the study of better passing ability of AAS concrete mixes in order to use self compacting AAS concrete in field.

An Experimental study on the Characteristics of the Emulsion Lubrication (이멀션윤활특성에 관한 실험적 연구)

  • 이종순;이봉구;정재련;지창헌
    • Tribology and Lubricants
    • /
    • v.2 no.2
    • /
    • pp.12-19
    • /
    • 1986
  • Using emulsion lubricant whose cooling effect and incombustibility are good and which is economical, I investigated lubricative mechanism and the behavior of scattered particles in the elastic fluid lubrication region with the line contact between rollers and plates and the light interference system. The results of the study are as follows: (1) The flow in the squeeze oil film is considered as comparatively wide clearance and narrow one, and in the former case the effect of the distribution of particles and the velocity on the flow. In the latter case, emulsion particles stay in the clearance an the oil film changes with the decrease of the oil film thickness. (2) In the wide clearance the velocity difference of the flow O/W or W/O emulsion is inverse proportional to the particle size. In the narrow clearance the distribution of the remained drops is different from one another and the scattered particles change more easily in O/W type than in W/O type. (3) At the beginning of the EHL the stagnation region with slow flowing velocity exists and the behavior at the region is different depending on the particle size. (4) By observing the dischromatic light interference line, emulsion oil passing through EHL region and the crack behavior at the beginning of EHL were found.

Passing Performance of HPC Between Reirforcing Bar with Maximum Size of Coarse Aggregate (굵은골재의 최대치수에 따른 고성능 콘크리트의 간극통과성)

  • Yoon, Seob;Baik, Dae-Hyun;Kim, Jung-Bin;Park, Chang-Soo;Lee, Seong-Yeun;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.129-132
    • /
    • 2006
  • This paper is to investigate passing performance of high performance concrete between reinforcing bar depending on maximum size of coarse aggregates. Increase in maximum size of coarse results in decrease in water demand and sand to aggregate to secure target slump flow. The larger the maximum size of coarse aggregates is, the denser the space between reinforcing bar is, the amount of concrete passed through the reinforcing bar cage shows to decrease. HPC has favorable passing performance, regardless of aggregate size, when only vertical reinforcing bar is arranged. Whereas, when vertical and horizontal reinforcing bar is arranged at the same time, proper space between reinforcing bar is considered larger than 32mm in case of using 20mm coarse aggregate, 38mm in case of using 25mm aggregate. The increase in maximum size of coarse aggregate leads to increase compressive strength slightly. Length change shows to be decreased with the increase in maximum size of coarse aggregate.

  • PDF