• Title/Summary/Keyword: 각막 지형도 검사

Search Result 13, Processing Time 0.02 seconds

A Comparison of the Movement of Aspheric RGP Lens on Cornea by the Amounts of Keratometric Astigmatisms using Keratometer and Corneal Topography (각막곡률계와 각막지형도를 이용한 각막난시 측정값에 따른 비구면 RGP 렌즈의 각막에서 동적움직임 비교)

  • Park, Sang-Il;Lee, Se Eun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.123-133
    • /
    • 2011
  • Purpose: The present study was conducted to analyze any difference in the movement of aspheric RGP lens by the amounts of keratometiric astigmatisms using keratometer and corneal topography. Methods: Corneal curvatures in thirty six eyes of males and females of with-the-rule keratometric astigmatisms in their twenties were measured by a keratometer and worn aspheric RGP lenses. Then, lens rotations, vertical and horizontal movements of lens by blinking were measured to compare with lens movements when aspheric RGP lenses were fitted by total keratometric astigmatisms using corneal topography. Results: The case having higher amount of central keratometric astigmatism was 61.1% of subjects, however, 36.1% of subjects showed higher total keratometric astigmatism indicating that central keratometric astigmatism was not always bigger than total keratometric astigmatism. Since over 0.25 diopter difference between total and central keratometric astigmatisms was shown in 19 eyes (52.8% of subjects), the prescription for lens fitting could be changed. Significant difference in horizontal movement was detected with increase of astigmatism when it compared based on the amount of keratometric astigmatism measured by a keratometer. However, there was no significant difference in lens rotation, horizontal and vertical movements by comparison with the amount of total keratometric astigmatism using a corneal topography. When central keratometric astigmatism measured by keratometer was bigger than total keratometric astigmatism estimated by corneal topography, bigger lens rotation was shown compared with opposite case. Also, the tendency of bigger lens rotation was measured with the increase of keratomatric astigmatism in the case of same prescription having same base curves with same amount of keratometric astigmatism but different curvatures. Conclusions: From the present study, we concluded that lens movements on cornea were not totally different when aspheric RGP lens fitted on with-the-rule astigmatism by keratometer and corneal topography. However, there was some difference in certain lens movements. Therefore, we concluded that further study on the relationship between the prescriptions for lens fitting should be conducted for improving the rate of successful lens fitting by keratometer or for the proper application of corneal topography for lens fitting.

A Comparison of Lens Centrations on Cornea with RGP Lens Fitting by the Measured Values using Keratometer and Corneal Topography (각막곡률계와 각막 지형도 검사에서의 측정값을 이용한 RGP 렌즈 피팅시 각막에서의 중심안정위치 비교)

  • Kim, So Ra;Park, Sang-Il;Lee, Se Eun;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2011
  • Purpose: The present study was conducted to compare the centration of RGP lens on cornea when lens was fitted based on keratometric astigmatisms measured by keratometer and the lens centration when fitted by corneal topography. Methods: Thirty eight eyes of 19 male and female in their twenties were applied RGP lens with 9.9 mm of diameter by the keratometric astigmatisms classified by the measurement with a keratometer. Then, lens centrations were estimated using high speed camera and compared with the lens centration when fitted by total keratometric astigmatism using corneal topography. The relationship of the steepest location of cornea and lens centration was further compared. Results: With the rule astigmatism, lens centration was not changed even with the difference in central and total keratometric astigmatisms. When the relationship of the steepest part of cornea measured by corneal topography and lens centration was analyzed, the lens centration in vertical direction was exactly correlated with the steepest part of cornea in 52.3% of subjects. In the case of non-correlation, the steepest part of cornea was mostly upper part of cornea, however, lens centration was located on lower part of cornea. The lens centration in horizontal direction was exactly correlated with the steepest region of cornea in 65.6% of subjects. In non-correlated case, the difference in cornea curvatures between the steepest and the flattest parts was smaller than 0.05 mm in 76.9% of subjects. Conclusions: From these results, we conclude that corneal topographic patterns may more contribute the centration of RGP lens on cornea than the difference in central and total keratometric astigmatisms.

Analysis of Corneal Topography for Korean College Students Based on Computer-Assisted Videokeratography (각막지형도 검사를 이용한 대학생의 각막형태에 대한 연구)

  • Lee, Seok-Ju;Ryu, Guen-Chang;Shin, Cheol-Guen;Seong, Jeong-Sub;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.241-247
    • /
    • 2006
  • Purpose : To define the distribution of normal corneal topographic patterns of Korean college students and compare them with previously published western data, Bogan et al's study. Methods : Computerized corneal topography was performed 220eyes normal subjects using CTK-922(Topography, swiss made). Mean age of the subjects was 23.2 yr.(range 19 to 57 yr.). The color-coded videokeratographs were classified by a masked observer according to the Bogan et al's classification such as round, oval, symmetric bow tie, asymmetric bow tie, and irregular. Results: The results revealed 57 eyes(25.9%) had round, 14 (6.4%) oval , 41(18.6%)symmetric bow tie, 78(35.5%) asymmetric bow tie, and 30(13.6%) irregular pattern. Conclusions : Our results of topographic patterns show the tendency of more irregular and less round topographic pattern in Korean college students, as compared to that of western adults.

  • PDF

Determination of Corneal Aberrations Using Corneal Shape of Topographer (각막지형검사기의 각막형상을 이용한 각막수차 구현)

  • Park, Seong-Jong;Kim, Sun-Young;Han, Kyung-Soo;Joo, Seok-Hee;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: In this study a program was developed to determine corneal aberrations using corneal shape of topographer and represented a wavefront and corneal aberrations using zernike polynomial. Methods: When the pupil size was 6 mm, we calculated new corneal shape data with zernike polynomials using corneal shape data of ORBSCAN topographer. We programmed the wavefront construction using ray tracing for corneal shape, then represented corneal aberrations having zernike polynomial with 6th order and 28 terms. Conclusions: We developed programs to determine a wavefront and corneal aberrations using corneal shape of ORBSCAN topographer. Theses results will be applied to a development of new topographer and prescription of contact lens and OK lens.

  • PDF

Changes of Refractive Errors Caused by Corneal Shape and Pupil Size (각막지형과 동공크기에 의한 굴절교정값의 변화)

  • Noh, Yeon Soo;Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.383-387
    • /
    • 2014
  • Purpose: To investigate the effect of corneal unique shape to changes of refractive full corrections when pupil size changes. Methods: Subjective refraction for monocular full correction was performed to 30 subjects ($23.33{\pm}1.78$ of age, 60 eyes) in two room conditions, 760 lx and 2 lx, respectively. Pupillary diameter was measured in two conditions and the change pattern was analyzed using a peak data of corneal topography. Results: Pupillary diameter was 3.74~4.00 mm in 760 lx and 5.52~5.90 mm in 2 lx. By comparison with refractive data in 760 lx, those data in 2 lx was changed as follows: more (-) spherical power of 17 eyes (28.3%), more (+) spherical power of 10 eyes (17.7%), more (-) cylinderical power of 17 eyes (28.8%), less (-) cylinderical power of 9 eyes (15.3%), and astigmatic axis rotation of 36 eyes (62.1%). From peak data of corneal topography, the changing pattern of two principal meridians was classified into 4 types. Conclusions: Expansion of the corneal refractive surface accompanied with pupillary dilation may be a main factor that effects the changing a values of subjective refraction because of unique corneal shape. Therefore, subjective refraction should be performed under the nearest lighting condition to a main living environment.

Effect of Everted(inside out) Silicone Hydrogel Lens on Corneal Topographical Changes (역방향으로 착용한 (inside out or everted) 실리콘 하이드로겔 렌즈가 각막형상 변화에 미치는 영향)

  • Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the corneal topographical changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The shape and fluorescein pattern of everted silicone hydrogel lenses were investigated. The subject wore the silicone hydrogel everted lenses overnight for 8 hours. Objective refractive error and corneal shape were evaluated at baseline, 1, 2, 3, 5, and 7 days after lens wearing and 1,2,3, and 4 days after discontinuation of lens wear. Results: The Fluorescein pattern of everted silicone hydrogel lenses was similar to the reverse geometry lenses with pressure profile. Objective refractive error(sphere power) and corneal refractive power were decreased and corneal shape had changed during the everted silicone hydrogel lenses wear and recovered during the 4 days of discontinuation. Subject experienced no discomfort associated with the everted silicone hydrogel lenses. Conclusions: It appears that everted silicone hydrogel lenses are capable of inducing significant changes in corneal topography, with overnight wear. Further study must be done to help understand these changes to develop a predictable and effective way of using soft contact lenses for corneal reshaping.

The Analysis of Corneal Patterns in Korean 20s by Corneal Topography and Corneal Radii by Astigmatic Degree (각막지형도를 이용한 20대의 각막형상 및 난시도에 따른 각막곡률반경의 분석)

  • Kim, So Ra;Gil, Ji-Yeon;Park, Chang Won;Kim, Ji Hye;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.273-281
    • /
    • 2011
  • Purpose: In order to provide the fundamental information for the design development of RGP lenses and its clinical prescription, the corneal types of Korean twenties were analyzed according to corneal shapes, astigmatic degree, and the certain distance from the corneal apex. Methods: Corneal types of total 252 eyes in 20s were firstly classified, then their corneal radii from the certain distance from the corneal apex were measured by corneal topography and further analyzed based on the astigmatic degree. Results: Korean 20s' corneal types were classified as 14.3%(36 eyes) of round, 31.3%(79 eyes) of oval, 28.6%(72 eyes) of symmetric bow tie, 17.5%(44 eyes) of asymmetric bow tie, 8.3%(21 eyes) of irregular shapes. The round and oval typed corneas had mild astigmatic degree whereas the higher astigmatic degree in symmetric and asymmetric bow tie typed corneas were shown. The relative corneal radii of round and oval typed corneas at each distance from corneal apex were shown to consistently increase regardless of astigmatic degrees when they measured at certain distances from the corneal apex. However, the relative corneal radii of symmetric and asymmetric bow tie typed corneas within 1.0-1.5mm from the corneal apex were decreased, which showed steeper slope than it within 1.0 mm and somewhat different based on astigmatic degrees. Bigger change of corneal radii outer 3.5 mm from the corneal apex in symmetric bow tie typed corneas with astigmatism of 1.50-2.00 D and 2.25-2.75 D appeared. Conclusions: The consideration of radial change from the central cornea to peripheral cornea is necessary for manufacturing RGP lens and its prescription since they showed different change in corneal radii by corneal patterns and astigmatic degrees.

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

The Change of Corneal Refractive Power by Everted Silicone Hydrogel Contact Lens Wear (역방향 실리콘 하이드로겔 렌즈 착용에 따른 각막 굴절력 변화)

  • Kim, Soo-Hyun;Shin, Dong-Min;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.271-277
    • /
    • 2013
  • Purpose: The purpose was to study the corneal refractive power changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The corneal refractive power and corneal astigmatism were measured using corneal topographer (CT-1000, Shin-nippon Co., Japan) for checking change of corneal refractive power and objective refractive error was measured by auto-refractometer (Natural vision-K 5001, Shin-nippon Co., Japan). We measured at baseline and 1 week after lens wearing. Results: The correcting of corneal refractive power could be effective in low myopia. It's more effective to the higher power of greatest meridian of cornea and the more corneal astigmatism. 73% of subjects' refractive error was decrease less than 1 D and 17% of the subjects had an reverse effect (increase) occurs. The reduction of objective refractive error was more effective when cornea refractive power was great or corneal astigmatism was much. Conclusions: Pressure which the everted silicone hydrogel lens to the cornea could be caused. It occurred as the degrees of corneal power, corneal astigmatism and objective refractive error differences. Selection of an appropriate subject is important considering difficulty of changing the parameters of the lens.

The Efficacy and Effect of Reverse Geometry Contact Lens on Cornea (역기하학 렌즈의 유효성과 각막에 미치는영향)

  • Kim, Kwang-Bae;Kim, Young-Hoon;Bark, Sang-Bai;Sun, Kyung-Ho;Jeong, Youn-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Object of this research is to estimate the effect of myopia correction and safety on reverse geometry contact lens fitting in school children. This research include 53(106eyes) schoolchildren among 7 to 18 years who has low to moderate myopia(-1.00D~-5.00D) and prescribed reverse geometry contact lens for purpose on orthokeratology between January to July 2004 and had 3months full follow up examination. They were tested for slit lamp examinations, BUT(Break up time), direct ophthalmoscopy, retinoscopy, uncorrected visual acuity, best corrected visual acuity, autorefraction, autokeratometry and corneal topography in each examination(1day, 1week, 2weeks, 1, 2, and 3months) of before-and-after lens wearing to find out the effect of myopic correction and side effect. The results came out as follow. The average of uncorrected visual acuity was $0.0938{\pm}0.378$ before lens wear and $0.3136{\pm}0.283$ after 1day lens wear, and there was fast improvement after 1week($0.7925{\pm}0.301$) and little improvement after 2weeks period but still they shows better uncorrected visual acuity(p<0.01). The result of this study, the reverse geometry lens is very useful to correct refractive error and control the progression of myopia temporally among low to moderate myopic patient. The side effects were relatively rare but further study should be necessary with long term lens wear effect on eye health. For the lens prescription, the clinical fitting process had higher rate of success with consideration of eccentricity and corneal topography.

  • PDF