• Title/Summary/Keyword: 각막굴절교정렌즈

Search Result 19, Processing Time 0.021 seconds

The Effect of Refractive and Corneal Recovery after Discontinuation of Orthokeratology Contact Lenses in Children (각막굴절교정렌즈 어린이 착용자에서 착용 중지 후 굴절력과 각막형상 복귀에 관한 연구)

  • Mun, Mi-Young;Lee, Koon-Ja;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: To investigate the corneal recovery after discontinuing orthokeratology (OK) lenses wear in children for long-term period. Methods: Among the OK lens wearers who wear over 8 months and showed successful refractive correction, 25 subjects were selected who want to discontinue the OK lenses. Uncorrected visual acuity, refractive correction, corneal curvature (Sim K), central corneal thickness and corneal eccentricity were measured during the OK lens wearing period and after discontinuation for 1 month. Results: Uncorrected visual acuity and corneal shape had remodeled significantly during the OK lens wear and recovered significantly during the first week of discontinuation. Uncorrected visual acuity and refractive correction had achieved full recovery 2 weeks after discontinuation of lens wear and were highly correlated with the changes in corneal thickness. But corneal shape recovered slowly, eccentricity had recovered fully after 1 month and corneal curvature and central thickness had not been achieved full recovery until 1 month after discontinuation. Conclusions: Recovery of after longterm use of OK lens is rapid for refractive change, but slow for corneal curvature and central thickness that to refit the contact lenses, practitioners need patience.

  • PDF

The Effect of Long-Term Orthokeratology in Different Age Groups (장기간 굴절교정렌즈 착용자에서 연령군 별 굴절교정효과 비교)

  • Mun, Mi-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the effect of age in the response to long-term overnight orthokeratology (OK) lens wearing. Methods: Among volunteers, ninety-five healthy subjects who had no eye diseases and could wear OK contact lens at least for 8 hours every day were divided into three groups children, youngsters and young adults. Unaided logMAR visual acuity, refractive error, apical corneal radius, corneal asphericity and central corneal thickness were measured with different period; before and after one day, one week, two weeks, one month, three months and six months of OK lens wear. Paired student t-test, ANOVA analysis and Pearson correlation were used with a critical p value of 0.05 for statistical analysis. Results: All groups showed statistically significant (p<0.001) improvement in unaided visual acuity, a trend for flattening in the apical corneal radius, decrease in central corneal thickness and less prolate after OK lens wear. The child group showed significantly rapid change (p<0.001) in visual acuity, and apical corneal radius showed that they reached the targeted refractive change earlier compared with youngster and adult groups. The visual effect of OK lens was significantly related with the change in central corneal thickness after long-term OK lens wear, especially in child and youngster group, and central corneal thickness were highly correlated with the targeted refractive change. Conclusions: Visual acuity change is statistically correlated with the central corneal thickness change, which is highly correlated with targeted refractive change in the long-term orthokeratology and younger lens wearers showed a rapid response to OK lens wear, suggesting a reduced epithelial response with increasing age. The results found this study extends our understanding and development in the long-term orthokeratology.

  • PDF

The Change of Corneal Refractive Power by Everted Silicone Hydrogel Contact Lens Wear (역방향 실리콘 하이드로겔 렌즈 착용에 따른 각막 굴절력 변화)

  • Kim, Soo-Hyun;Shin, Dong-Min;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.271-277
    • /
    • 2013
  • Purpose: The purpose was to study the corneal refractive power changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The corneal refractive power and corneal astigmatism were measured using corneal topographer (CT-1000, Shin-nippon Co., Japan) for checking change of corneal refractive power and objective refractive error was measured by auto-refractometer (Natural vision-K 5001, Shin-nippon Co., Japan). We measured at baseline and 1 week after lens wearing. Results: The correcting of corneal refractive power could be effective in low myopia. It's more effective to the higher power of greatest meridian of cornea and the more corneal astigmatism. 73% of subjects' refractive error was decrease less than 1 D and 17% of the subjects had an reverse effect (increase) occurs. The reduction of objective refractive error was more effective when cornea refractive power was great or corneal astigmatism was much. Conclusions: Pressure which the everted silicone hydrogel lens to the cornea could be caused. It occurred as the degrees of corneal power, corneal astigmatism and objective refractive error differences. Selection of an appropriate subject is important considering difficulty of changing the parameters of the lens.

Study of Masking Effect of Soft Contact Lenses on Cornea after Refractive Surgery (각막굴절교정 수술 안에 대한 소프트콘택트렌즈 착용 시 Masking 효과)

  • Moon, Ye-Rim;Park, Hyung-Min;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 2016
  • Purpose: This study investigated the masking effect of the hydrogel lens and silicone hydrogel lens on the cornea with refractive surgery and without surgery. Methods: 24 university students (means age: $23.48{\pm}2.89years$) without refractive surgery (12, control group) and with refractive surgery (LASIK: 8, LASEK: 4, experimental group) participated in the study. Mean refractive errors of right eyes were -2.73 D for control group and -0.24 D for experimental group. The differences in the refractive power and corneal topography map between pre- and post-wearing the -3.00 D lenses were compared, and 2 kinds of hydrogel contact lenses (0.89 Mpa, 0.49 Mpa) and 2 kinds of silicone hydrogel lenses (1.5 Mpa, 0.8 Mpa) were used for -3.00 D lenses. NVision-K5001 (Shin nippon, Japan) was used to measure the refractive power and Keratograph 5M (Oculus, Germany) to measure the corneal topography map change. Results: Variations in the refractive power increased to the plus direction in the experimental group after wearing soft contact lenses. The corneal topography map showed significant changes on the both groups after wearing soft contact lenses (p<0.05). However there were no significant differences in the refractive power and corneal topography map variations by lens materials. Conclusions: Wearing soft contact lenses showed corneal topography map changes. Especially wearing soft contact lenses on the flat cornea after corneal refractive surgery showed greater corneal power changes. Therefore, it should pay attention to refractive change in case of prescribing soft contact lenses to patients with corneal refractive surgery.

The Change in Corneal Eccentricity on the Correction of Refractive Error using Reverse Geometry Lens (역기하렌즈(Reverse Geometry Lens)의 굴절교정시 각막 편심률(Eccentricity)의 변화)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Purpose: In this study we investigated the correlation between the effect of myopia correction and the change of corneal eccentricity using reverse geometry lens. Methods: The 23 students (46 eyes) continuously wearing reverse geometry lens during 3 months were divided into Group I and Group II by different parameter fitting methods of wearing Reverse Geometry Lens. We measured a corneal eccentricity for Group I and Group II at $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ positions from corneal apex before wearing reverse geometry lens, 1 week, 1 month, and 3 months after wearing reverse geometry lens. We also measured an uncorrected visual acuity, a spherical equivalent, and a corneal radius and analyzed the correlation between them and the change of corneal eccentricity using statistical significance test. Results: There were the statistical significances of a change of corneal eccentricity (p=0.03, t=-2.29) for Group I and Group II at 10 position from corneal apex in a week after wearing reverse geometry lens, but were not those (p>0.05) in 1 month, and 3 months after wearing reverse geometry lens. There were the statistical significances of correlation between the change of corneal eccentricity and a corrected visual acuity, and a corneal radius, respectively. Particularly, the high correlation between the change of corneal eccentricity and a corrected visual acuity (r=-0.36, p=0.00, t=6.5), and a spherical equivalent (r=-0.72, p=0.00, t=-70.5) for Group II in a week after wearing reverse geometry lens showed. Conclusions: We knew from these results that the high correlation between the effect of myopia correction and the change of corneal eccentricity in a week after wearing reverse geometry lens represented.

Effect of Everted(inside out) Silicone Hydrogel Lens on Corneal Topographical Changes (역방향으로 착용한 (inside out or everted) 실리콘 하이드로겔 렌즈가 각막형상 변화에 미치는 영향)

  • Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the corneal topographical changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The shape and fluorescein pattern of everted silicone hydrogel lenses were investigated. The subject wore the silicone hydrogel everted lenses overnight for 8 hours. Objective refractive error and corneal shape were evaluated at baseline, 1, 2, 3, 5, and 7 days after lens wearing and 1,2,3, and 4 days after discontinuation of lens wear. Results: The Fluorescein pattern of everted silicone hydrogel lenses was similar to the reverse geometry lenses with pressure profile. Objective refractive error(sphere power) and corneal refractive power were decreased and corneal shape had changed during the everted silicone hydrogel lenses wear and recovered during the 4 days of discontinuation. Subject experienced no discomfort associated with the everted silicone hydrogel lenses. Conclusions: It appears that everted silicone hydrogel lenses are capable of inducing significant changes in corneal topography, with overnight wear. Further study must be done to help understand these changes to develop a predictable and effective way of using soft contact lenses for corneal reshaping.

The Efficacy and Effect of Reverse Geometry Contact Lens on Cornea (역기하학 렌즈의 유효성과 각막에 미치는영향)

  • Kim, Kwang-Bae;Kim, Young-Hoon;Bark, Sang-Bai;Sun, Kyung-Ho;Jeong, Youn-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Object of this research is to estimate the effect of myopia correction and safety on reverse geometry contact lens fitting in school children. This research include 53(106eyes) schoolchildren among 7 to 18 years who has low to moderate myopia(-1.00D~-5.00D) and prescribed reverse geometry contact lens for purpose on orthokeratology between January to July 2004 and had 3months full follow up examination. They were tested for slit lamp examinations, BUT(Break up time), direct ophthalmoscopy, retinoscopy, uncorrected visual acuity, best corrected visual acuity, autorefraction, autokeratometry and corneal topography in each examination(1day, 1week, 2weeks, 1, 2, and 3months) of before-and-after lens wearing to find out the effect of myopic correction and side effect. The results came out as follow. The average of uncorrected visual acuity was $0.0938{\pm}0.378$ before lens wear and $0.3136{\pm}0.283$ after 1day lens wear, and there was fast improvement after 1week($0.7925{\pm}0.301$) and little improvement after 2weeks period but still they shows better uncorrected visual acuity(p<0.01). The result of this study, the reverse geometry lens is very useful to correct refractive error and control the progression of myopia temporally among low to moderate myopic patient. The side effects were relatively rare but further study should be necessary with long term lens wear effect on eye health. For the lens prescription, the clinical fitting process had higher rate of success with consideration of eccentricity and corneal topography.

  • PDF

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

Scotopic Pupil Size in Myopes (근시안에서 암순응상태의 동공크기)

  • Jeong, Woo-Jae;Jeon, In-Chul;Kang, Ji-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.197-202
    • /
    • 2013
  • Purpose: This research was performed to measure and analyze scotopic pupil size in myopes and to figure out the factors that influence it. Methods: The pupil size of 191 healthy myopic subjects were measured with the pupillometer (Colvard pupillometer, OASIS medical, USA) in scotopic and analyzed with the age, corneal size, spherical equivalent refractive error, corneal curvature. In addition, it was compared with the measurements of intra-examiner and inter-examiner to verify reproducibility of pupillometer. Results: The mean (${\pm}$SD) scotopic pupil size was $6.64{\pm}0.68$ mm (range, 5.00~8.00 mm), the lower age and the larger corneal size, The bigger the pupil size. The lower spherical equivalent refractive error and steepper corneal curvature tends to be smaller. The reproducibility of intra-examiner and inter-examiner in pupillometer showed the reliability highly (Guttman splithalf point > 0.91). Conclusions: The pupil size associated with age, corneal size, spherical equivalent refractive error and corneal curvature in scotopic condition. It can refer to prevent inconvenience that may occur RGP contact lenses, cataract surgery and refractive surgery.

The optical properties on the human model eye (모형 안의 광학적 성능)

  • Lim, Hyeonseon;Ji, Taeksang;Kim, Bonghwan;Kim, Sejin;Yoon, Sungro
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.203-207
    • /
    • 2002
  • In this study, by using the eye model of NAVARRO, KOOIJMAN, MAHKICHOONG, the properties of optical system are reserched in a finite ray tracing method, when ametropia is corrected by glasses or contact lens, this study is useful as a reference. Also, when Auto-refractometer for refraction test and Keratomeler are designed, these eye models can be used.

  • PDF