• Title/Summary/Keyword: 각막곡률

Search Result 45, Processing Time 0.027 seconds

Analysis of anterior and posterior corneal spherical aberration with age in the korean (한국 성인의 연령에 따른 각막 전후면 구면수차에 관한 분석)

  • Song, Yun-Young;Jung, Mi-A;Kang, In-San;Choi, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.315-320
    • /
    • 2013
  • We have investigated the variation of spherical aberration of the anterior and posterior surface in a Korean sample population with various age between 20 to 71 years old. We used Pentacam (Oculus Inc., Germany) to measure the corneal radius, asphericity, and spherical aberration of 290 patients with normal cornea. There were negative correlation between corneal anterior radius and spherical aberration(r = -0.22, p<0.0001), and, there were negative correlation between corneal posterior radius and spherical aberration(r=-0.27, p < 0.0001). There were positive correlation between anterior asphericity and spherical aberration(r = 0.24, p < 0.0001), however there were negative correlation between posterior asphericity and spherical aberration(r = -0.17, p=0.00288).The average of anterior spherical aberration and posterior spherical aberration was $0.482{\pm}0.099{\mu}m$ and $-0.098{\pm}0.029{\mu}m$. The average of spherical aberration was $0.385{\pm}0.097{\mu}m$. There were significant positive correlations between anterior spherical aberration and age(r = 0.227, p<0.0001), and there were positive correlations between posterior aberration and age(r = 0.349, p<0.0001). It is considered that this data can be used as basic information for furture studies for improving the quality of vision of modern human and, through the analysis of the spherical aberration of cornea was to provide a better understanding of the optical part of the Korean's eye.

The Correlation of Myopic Refractive Error and Ocular Components in Primary School Students (초등학생의 근시성 굴절이상과 안광학 성분들의 관련성)

  • Jeon, Soon-Woo;Lee, Hyun-Joo;Hwang, Hye-Kyung;Park, Chun-Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.299-303
    • /
    • 2012
  • Purpose: In this study the correlation among the myopic refractive error and ocular components in primary school students was investigated. Methods: The subjects were 62 children who had no eye diseases. The refractive error, corneal radius, anterior chamber depth, lens thickness, axial length were measured and analysed. Results: Myopic refractive error in primary school students was negatively correlated with the axial length (1~3rd grade r=-0.653, p=0.000/4~6th grade r=-0.742, p=0.000), AL/CR ratio (1~3rd grade r=-0.571, p=0.000/4~6th grade r=-0.852, p=0.000). Conclusions: It was shown that the axial length and axial length(AL)/corneal radius(CR) ratio were very important data for myopic refractive error in primary school students.

The differences of tear film for young Korean of a day indoor space (실내 공간 내에서 한국인 청년의 하루 중 눈물층 변화)

  • Oh, Hyun Jin;Lee, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.535-540
    • /
    • 2012
  • This study is to research the differences of tear film for young people in of a day in a restricted indoor space. The subjects are 58 eyes volunteers for twice preliminary inspection and tear test of a day. 58 healthy individuals with no eye disease, no body disease, orthophoria, corrective visual acuity more than 0.8, binocular spherical equivalence difference over 0.50 diopter, the flattest corneal curvature in horizontal meridian and the steepest corneal curvature in vertical meridian were tested. The uncorrective visual acuity, refractive error, corneal curvature, schirmer test and tear break up test were performed in the morning and afternoon. Schirmer test were $16.0{\pm}7.0mm$ in the morning and $14.1{\pm}7.1mm$ in the afternoon. TBUT were $11.3{\pm}0.6$ sec in the morning and $12.1{\pm}0.9$ sec in the afternoon. They have no significant differences.

The Effect of Long-Term Orthokeratology in Different Age Groups (장기간 굴절교정렌즈 착용자에서 연령군 별 굴절교정효과 비교)

  • Mun, Mi-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the effect of age in the response to long-term overnight orthokeratology (OK) lens wearing. Methods: Among volunteers, ninety-five healthy subjects who had no eye diseases and could wear OK contact lens at least for 8 hours every day were divided into three groups children, youngsters and young adults. Unaided logMAR visual acuity, refractive error, apical corneal radius, corneal asphericity and central corneal thickness were measured with different period; before and after one day, one week, two weeks, one month, three months and six months of OK lens wear. Paired student t-test, ANOVA analysis and Pearson correlation were used with a critical p value of 0.05 for statistical analysis. Results: All groups showed statistically significant (p<0.001) improvement in unaided visual acuity, a trend for flattening in the apical corneal radius, decrease in central corneal thickness and less prolate after OK lens wear. The child group showed significantly rapid change (p<0.001) in visual acuity, and apical corneal radius showed that they reached the targeted refractive change earlier compared with youngster and adult groups. The visual effect of OK lens was significantly related with the change in central corneal thickness after long-term OK lens wear, especially in child and youngster group, and central corneal thickness were highly correlated with the targeted refractive change. Conclusions: Visual acuity change is statistically correlated with the central corneal thickness change, which is highly correlated with targeted refractive change in the long-term orthokeratology and younger lens wearers showed a rapid response to OK lens wear, suggesting a reduced epithelial response with increasing age. The results found this study extends our understanding and development in the long-term orthokeratology.

  • PDF

Analysis on Ocular Components Variation with the Difference of Both Refractive Errors (양안 굴절이상 차이에 의한 안광학상수 변화도 분석)

  • Lee, Hae-Jung;Lee, Eun-Hee;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.435-440
    • /
    • 2016
  • The aim of study was to provide the preliminary data to find out characteristics of the difference between both refractive errors through analysis of ocular components variation. We measured spherical equivalent power and corneal radius with KR-8800, and axial length and anterior chamber depth with IOL Master, and the difference of measuring values between the right eye and left eye was applied as the absolute values in 100 adults aged 20~59 years. In all participants, the most common results showed that spherical equivalent power was $-1.83{\pm}2.17D$, axial length was 23.00~24.99mm, corneal radius was 7.50~7.89mm, and anterior chamber depth was 3.60~4.09mm. There are significant correlations between both eyes in axial length and anterior chamber depth with the difference of both spherical equivalent power. The difference of both axial lengths was the biggest with the difference of both refractive errors, and shown the highest correlation. The convergence complex study through classification by aspects is needed since the difference of both refractive errors is closely related with ocular components variation, and poor visual function would be caused by the difference of both refractive errors.

Measurement of Radius of Corneal curvature for Korean adults with Keratometer (한국인 성인 남녀의 각막곡률반경측정)

  • Kang, H.S.;Seo, Y.W.;Kang, I.S.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.71-76
    • /
    • 1996
  • As the results of measurement of the radius of corneal curvature with keratometer, for the right eye of 91 male adults, horizontal radius is 7.16 mm to 8.49 mm and vertical radius is 7.03 mm to 8.34 mm, and for the left eye of male adults, horizontal radius is 7.10 mm to 8.48 mm and vertical radius is 7.01 mm to 8.24 mm. In case of 61 female adults, horizontal radius is 7.16 mm to 8.45 mm, vertical radius 7.11 mm to 8.18 mm for the right eye, and horizontal radius 7.15 mm 108.43 mm and vertical radius 7.01 mm to 8.26 mm for the left eye. The mean value of radius of corneal curvature is 7.74 mm for male and 7.69 mm for female. Also the mean value of horizontal radius is 7.79 mm and vertical radius is 7.64 mm. Overall mean value of the radius of corneal curvature is 7.71 mm that is corresponded to Gullstrand's eye. The horizontal radius is 0.15 mm bigger than vertical radius.

  • PDF

Study on the Correlation between Refractive error and Components of Eye's Optical system in Children and Teenagers in an Optometric Practice (안과 병원을 내원한 소아 청소년의 굴절이상과 안광학 성분간의 상관관계 연구)

  • Ha, Na-Ri;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.67-74
    • /
    • 2012
  • Purpose: The purpose of this study to evaluate visual acuity and refractive state and measure and analyze the components of eye's optical system in children and teenagers. Methods: With subjects of 124 (230 eyes) children and teenagers who had no eye diseases, correlation between the correlation between refractive errors and component's of eye's optical system was investigated. The spherical equivalent power of cycloplegic clinical refraction or manifest clinical refraction(SE), corneal power(CP), corneal radius(CR), axial length(AL), anterior chamber depth(ACD) and axial length to corneal radius (AL/CR) ratio were measured and analysed. Results: the SE was negatively correlated with the AL(r = -0.80, p = 0.00), the ACD(r = -0.35, p = 0.00) and the CR(r = -0.11, p=0.00) and positively correlated with the CP(r = +0.11, p=0.00). The AL was positively correlated with the AL/CR ratio (r = +0.84, p = 0.00), the ACD(r = +0.47, p=0.00) and the CR(r = +0.38, p = 0.00) and negatively correlated with the CP(r = -0.38, p=0.00). The CR was negatively correlated with CP(r = -1.00, p = 0.00), the AL/CR ratio(r = -0.19, p = 0.00) and the ACD(r = -0.06, p = 0.39). The CP was positively correlated with the AL/CR ratio(r = +0.19, p = 0.00) and the ACD(r = +0.06, p = 0.39). The ACD was positively correlated with the AL/CR ratio(r = 0.53, p = 0.00). Conclusions: the highest change of refractive errors was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive errors of the children and teenagers.

Estimation of Total Astigmatism Quantity from Corneal Astigmatism on Koreans in Their Twenties (한국인의 20대에서 각막난시에 의한 전난시량의 예측)

  • Yoo, Jong-Sook;Yu, Dong-Sik;Han, Kyung-Ae;Kim, Se-Jin;Wi, Sung-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.151-154
    • /
    • 2008
  • Purpose: Javals' rule is a commonly used formula for estimating total astigmatism from corneal astigmatism. Many researchers suggested a modication of Javals' rule. Therefore, we estimated the total astigmatism on the basis of measurements of corneal astigmatism and assessed the accuracy of Javals' rule. Methods: We estimated the total astigmatism on the basis of measurements of corneal astigmatism on 108 eyes of 54 subjects of koreans in their twenties. Results: The regression of the total astigmatism from corneal astigmatism is less than 1.25 of Javals' rule, but it was equivalent to Auger's modified Javals' rule. Conclusions: The regression equation for this study was as follows: Total Astigmatism=0.79 (Corneal Astigmatism)-0.49D${\times}$90.

  • PDF

Change of Corneal Shape with Soft Contact Lens Type (소프트콘택트렌즈의 유형에 따른 각막형태의 변화)

  • Woo, Chul-Min;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2014
  • Purpose: This study was to investigate changes in the thickness of cornea, curvature of cornea, and aberration depending on the water contents, materials, and refractive power of contact lens. Methods: The differences in the corneal thickness between pre- and post-wearing the lenses were compared using 5 kinds of lenses. The changes in the corneal thickness, the curvatures of the anterior and posterior cornea, and high order aberration (HOA) before and after wearing the lenses were investigated at the center of the cornea, and the different distance and the direction away from the center of the cornea. For the equipments of measurement, ORB ScanII (Bausch & Lomb Inc, ver 3.14) was used to measure the corneal topography and thickness, and Zywave (Bausch & Lomb Inc, ver 5.20) was used to analyze the high order aberration. Results: Five (S1, S2, S3, T1, T2) of the lens was used for this study, excluding the lens T2 lens has four lenses and the thickness of the corneal shape, but the impact is minimal. In the case of the hydrogel soft contact lenses (T2 lens) with low oxygen permeability, the corneal thickness showed distinct increasing patterns. The high order aberration and coma aberration were most changed in the silicon hydrogel toric lens, while the depth of anterior was most changed in the hydrogel toric lens. Conclusion: Among the 5 kinds of contact lenses with different water contents, materials, and refractive power used for this study, the corneal shape change was small for the lenses with an oxygen permeability (Dk) of more than 28, and the largest for the lenses with a very low oxygen permeability.

Study of an Aspherical Lens Design Method for Removing the Spherical Aberration of a Human Eye (눈의 구면수차 제거를 위한 비구면 렌즈 설계 기법 연구)

  • Kim, Ji Sung;Kim, Dong Min;Jin, Jong Hyun;Kim, Young Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.6
    • /
    • pp.299-305
    • /
    • 2015
  • Using Snell's Law without approximation, we analyzed focal points for parallel rays incident upon the cornea of a human eye. To calculate a ray's incident angle versus incident height for focusing on the same point, we used the ray reverse tracing method. We derived the theoretical conditions for an aspherical lens to remove the spherical aberration caused by a human eye. In this research, we held the rear surface of the lens to be spherical, for simple calculation, and calculated the lens curvature of the front surface to design an aspherical surface.