• Title/Summary/Keyword: 각과 측정

Search Result 12,395, Processing Time 0.037 seconds

Determination of Phase Velocity Dispersion Curve and Group Velocity of lamb Waves Using Backward Radiation (후방복사를 이용한 램파의 위상속도 분산과 군속도의 측정)

  • 송성진;권성덕;정용무;김영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • The guided wave has been widely employed to characterize thin plates and layered media. The dispersion curves of phase and group velocities are essential for the quantitative application of guided waves. In the present work, a fully automated system for the measurement of backward radiation of LLW has been developed. The specimen moves in two dimensional plane as well as in angular rotation. The signals of backward radiation of LLW were measured from an elastic plate in which specific modes of Lamb wave were strongly generated. Phase velocity of the corresponding modes was determined from the incident angle. The generated Lamb waves propagated forward and backward with the leakage of energy into water. Backward radiated LLW was detected by the same transducer and its frequency components were analyzed to extract the related information to the dispersion curves. The dispersion curves of phase velocity were measured by varying the incident angle. Moving the specimen in the linear direction of LLW propagation, group velocity was determined by measuring the transit time shift in the ultrasonic waveform.

Development of High Precision Docking Sensor for Mobile Robot (이동로봇을 위한 고정밀 도킹센서 개발)

  • Yoon, Nam-Il;Choi, Jong-Kap;Byun, Kyung-Seok
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.348-354
    • /
    • 2011
  • Mobile robots performed various missions in various environments. In order to move to target precisely, the mobile robots need a precise position sensing system In this paper, a new high precision docking sensor is proposed. Proposed docking sensor consists of linear CCD(charge coupled device) sensor and ultrasonic sensors. The docking sensor system can measure lateral position(X), longitudinal position(Y) and angle(${\theta}$) between the sensor and flat target with simple mark. Two ultrasonic sensors measure two distances which can be converted to longitudinal position and angle. Linear CCD sensor measures lateral position using center mark of the target. To verify performance of the sensor, the sensor is applied to an omnidirectional mobile robot. Several experimental results show highly precise performance of the sensor. Repeatability of the docking sensor is less than 1mm and $0.2^{\circ}$. Proposed docking sensor can be applied for precise docking of mobile robot.

Determining the Thickness of a Trilayer Thin-Film Structure by Fourier-Transform Analysis (푸리에 변환을 이용한 3층 구조 박막의 두께 측정)

  • Cho, Hyun-Ju;Won, Jun-Yeon;Jeong, Young-Gyu;Woo, Bong-Ju;Yoon, Jun-Ho;Hwangbo, Chang-Kwon
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.4
    • /
    • pp.143-150
    • /
    • 2016
  • The thickness of each layer in a multilayered system is determined by a Fourier-transform method using spectroscopic reflectance measurements. To verify this method, we first generate theoretical reflectance spectra for three layers, and these are fast-Fourier-transformed using our own Matlab program. Each peak of the Fourier-transformed delta function denotes the optical thickness of each layer, and these are transformed to physical thicknesses. The relative thickness error of the theoretical model is less than 1.0% while a layer's optical thickness is greater than 730 nm. A PI-(thin $SiO_2$)-PImultilayeredstructure produced by the bar-coating method was analyzed, and the thickness errors compared to SEM measurements. Even though this Fourier-transform method requires knowing the film order and the refractive index of each layer prior to analysis, it is a fast and nondestructive method for the analysis of multilayered structures.

Optical Measurement of Blood Oxygen Saturation for Artificial Heart Using Wavelength of 665nm and 805nm (665nm와 805nm의 파장을 이용한 인공심장용 혈중 산소포화도의 광학적 측정)

  • Park, Se-Kwang;Kwon, Ki-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.75-80
    • /
    • 1993
  • This study describes a non-invasive optical sensor and system in order to obtain oxygen saturation of blood, in-vitro. The sensor contains LED 665nm and 805nm of wavelength for light source and PIN photodiode for light detector in flat pack. The sensor system for measurement of oxygen saturation has breadboarded, including signal amplifier, filter, displayer, A/D converter, microprocessor and memory. Experimental set-up for non-invasive measurement of oxygen saturation in-vitro was done. When the variation of oxygen saturation is compared with that of each wavelength, the variation of 665nm is more than that of 805nm by five times. As oxygen saturation varies from 100% to 60%, and the reflection ratio (R805/R665) is changed linearly. The oxygen saturation in $100%{\sim}60%$ range can be measured with about 5% resolution by the developed sensor, such that if this sensor connects with the main artery and vein, the artificial heart can be controlled rapidly and precisely from measurement of the sensor.

  • PDF

New Design and Application of PVDF Ultrasonic Transducer for Measurement of Material Properties (재료물성 측정을 위한 직선집속 PVDF 초음파 트랜스듀서의 새로운 설계 및 응용)

  • Hong Soung-Wook;Kim Jung-Soon;Kim Sang-Yoon;Kim Moo-Joon;Ha Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.164-171
    • /
    • 2006
  • If the velocities of longitudinal, transverse and leaky surface acoustic waves in an isotropic material are given, the elastic constants and density of the material can be deduced analytically. Those velocities have been measured using three ultrasonic transducers with different vibrational modes so far. In this paper a line-focusing PVDF transducer with divided electrodes was newly proposed and designed for measuring approximate velocities of the three waves. The measurement method established in this study for each waves using the transducer was applied to several isotropic materials including fused quartz. The elastic stiffness constants and densities of the materials were calculated using the measured velocities, and the accuracies were discussed. It was shown that the obtained results are in good accord with the reference values.

Positioning Error Measurement and Compensation Using Laser Interferometer (레이저간섭계를 이용한 길이오차 측정 및 보정기술)

  • 박준호
    • Journal of the KSME
    • /
    • v.34 no.3
    • /
    • pp.185-192
    • /
    • 1994
  • 공작기계 및 측정기계 등은 여러 가지 요인에 의해서 오차를 갖게 되지만, 이들이 갖는 계통오 차는 정밀한 측정과 보정알고리즘에 의해 보정이 가능하다. 보정을 위한 측정방법은 여러 가지가 있지만 측정정밀도가 높은 헤트로다인레이저간섭계가 가장 많이 사용되고 잇다. 따라서 이글에 서는 헤트로다인레이저간섭계의 측정원리와 측정방법과 그 응용예를 소개하였다. 헤트로다인레 이저간섭계는 외부광학기를 교체하여 측정 가능한 길이, 각도, 진직도의 측정이 가능하므로 이 들에 대한 원리와 사용방법을 소개하였으며, 실예로 본 연구소에서 사용중인 제품과 개발한 제 품에 적용하여 시스템 오차의 측정방법과 보정방법을 통해 시스템의 정밀도가 향상됨을 보여 주었다. 헤트로다인레이저간섭계를 이용하여 측정시에도 측정기 자체가 갖고 있는 오차요인 즉, 빛의 속도가 일정하지 않고 공기의 습도, 온도 및 압력에 의해 결정되는 파장변화에 의한 오차와 피측정물의 온도변화에 의한 오차 등을 고려하여야 한다. 이런 이유로 측정시에는 센서를 사용 하여 현재 환경에 대한 영향을 자동으로 보상하든지 수동으로 온도 및 파장의 값을 기입하여 보정을 실시하여야 한다.

  • PDF

Comparison Surface Error Measurements of Aspherical Mirror (비구면 반사경 표면의 형상오차 측정법 비교)

  • An, Jongho;Pak, Soojong;Kim, Sanghyuk;Park, Woojin;Jeong, Byeongjoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.73.3-74
    • /
    • 2016
  • 본 연구에서는 비구면 반사경의 형상오차를 3가지 방법으로 측정, 비교하였다. 실험에 사용한 포물면 반사경의 구경은 108 mm, 유효초점거리는 444.5 mm 이다. 첫 번째로 접촉식 형상측정방식인 FTS(Form TalySurf)를 이용하여 표면 거칠기와 반사경의 최적 곡률 반경(BestFitt Radius) 값을 측정하였다. 두 번째로는 비접촉식 형상측정방식인 UA3P(Ultrahigh Accurate 3-D Profilometer)를 이용하여 반사경의 형상 정밀도를 측정하였다. UA3P를 이용할 경우 반사경의 전체 형상을 측정할 수 있다. 세번째로 Shark-Hartmann 센서를 이용한 광학측정방법으로 반사경의 형상 정밀도를 측정하였다. 측정에 필요한 레이저 광학계는 레이저, 콜리메이터, 핀홀, 카메라 렌즈 및 비구면 광학계를 이용하여 설계하였다. 본 연구에서 도출한 각 측정 방법의 신뢰도를 바탕으로 간섭계 사용에 제약이 있는 자유형상곡면의 반사경 표면의 형상오차 측정에 적용할 계획이다.

  • PDF

한국(韓國) 철강산업(鐵鋼産業)의 공해저감시설(公害低減施設)에 대한 적정규모(適正規模) 분석(分析)

  • Lee, Myeong-Heon;Kim, Il-Jung
    • Environmental and Resource Economics Review
    • /
    • v.8 no.1
    • /
    • pp.75-94
    • /
    • 1998
  • 철강산업에 있어서 공해저감시설의 설치와 증 개축시 발생하는 제반 문제점과 함께 불완전한 시장과 제약된 경영여건하에서 각 기업들은 주어진 요소의 시장가격으로 생산비용 최소화의 실현과 더불어 합리적이며 효율적인 생산활동을 하고 있다고는 할 수 없다. 본 연구에서는 한국 철강산업을 대상으로 일반비용 함수 방식에 의한 계수검정을 실시하여 공해저감시설 또는 자본을 포함한 각 생산요소의 상대가격 효율성 달성 여부를 알아본다. 그리고 비효율성으로 인한 생산비용의 상승효과를 측정하고 공해저감자본의 실제 투입량과 적정수준과의 차이를 측정하여 공해저감자본에 대한 적정 투입률을 분석한다. 측정 결과, 상대가격의 비효율성으로 인하여 1982년부터 1994년까지의 기간 동안 철강산업의 생산비용이 연평균 약 13.6% 증가되었으며 공해저감자본은 적정수준에 비해 연평균 48.4% 적게 투입된 것으로 나타났다.

  • PDF

탄소복합소재 분리판을 이용한 소형 고분자전해질 연료전지 스택 제작 및 성능분석

  • Shim, J.;Han, C.;Oh, Y.;Lee, J.J.;Lee, J.Y.;Lee, H.K.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.145.2-145.2
    • /
    • 2010
  • 탄소복합소재 분리판의 연료전지 성능을 시험하기 위해 소형 고분자연료전지 스택을 제작하였으며 연료전지 운전에 따른 성능변화를 측정하여 탄소복합소재 분리판이 연료전지 스택의 성능에 미치는 영향을 조사하였다. 자체 설계한 가스유로로 디자인된 분리판과 MEA를 적층한 스택의 초기 성능과 장기간 운전에 따른 전압 감소를 측정하였다. 또한 장시간 운전 동안 각 셀의 전압 거동도 함께 측정하였으며 비교를 위해 흑연 분리판을 이용하여 제작한 스택의 성능도 함께 시험하였다. 스택에서 각 셀의 성능은 단위전지에서의 성능과 유사하게 나타나 분리판과 스택의 구조가 셀의 성능을 충분히 보여줄 만큼 적절히 디자인된 것을 알 수 있었으며, 장시간 운전 동안 전류가 증가함에 따라 스택의 성능 감소도 점차 증가하였으며 두 종류의 스택이 유사한 성능 감소를 보여 자체 제작한 탄소복합소재 분리판이 흑연 분리판과 유사한 성능을 보임을 알 수 있었다.

  • PDF

Introduction of a New Acoustic Criterion for the Diffusivity of Rooms (실내음향의 새로운 확산성 평가요소에 관한 실험적 연구)

  • Kwon Gi-Woong;Haan Chan-Hoon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.445-450
    • /
    • 1999
  • 확산(Diffusion)은 실의 음향성능에 있어서 중요한 요소이나 확산성을 측정하기가 기술적으로 어렵고 실 표면에서의 확산정도도 계량하기가 어렸운것이 현실이다. 이에 본 연구의 목적은 현장실험을 통하여 표면의 확산성을 측정할 수 있는 새로운인자(가칭:${\Delta}x$)의 가능성을 개진하는 것이다. 실험결과에 의하면 확산성이 높은 홀에서 두개의 마이크로폰에 의하여 측정된 ${\Delta}x$의 값은 확산성이 높은 홀이 낮은 홀에서 보다 평균적으로 작은 값이 나왔다. 이것은 확산이 잘 이루어지는 홀에서는 각 방향으로의 음이 고루 분포하여 객석에 도달하고 있다는 것을 나타낸다. 즉 음이 각 방향으로 고루 전달되고 있다는 것을 나타낸다.

  • PDF