• Title/Summary/Keyword: 가해양상

Search Result 55, Processing Time 0.024 seconds

A SURVEY OF INTRAFAMILIAL CHILD SEXUAL ABUSE BY PHYSICIANS' REPORTS (의사들의 보고에 의한 근친간 아동성학대 연구)

  • Hong, Kang-E;Kang, Byung-Goo;Kwack, Young-Sook
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.9 no.2
    • /
    • pp.138-147
    • /
    • 1998
  • Authors surveyed intrafamilial child sexual abuse in the children under 15years old in clinical. We sent the semi-structured child sexual abuse questionnaires to 7055 board certified pediatrics, obstetrics and gynecology, family medicine and emergency medicine. Total respondents were 1205. The results from these respondents were as follows. 1) The numbers of respondents who have had the experience of treating victims of intrafamilial child sexual abuses were 157(13.0% of total respondents). 2) Among the perpetrators, 58(36.9%) were siblings and 32(20.4%) 26(16.6%) were step-fathers, and respectively. The most common age bracket was 10s(39.5%), and the next was 40s and 50s (33.7%) Almost all(98.7%) of the perpetrators were male. 3) The mean age of victims was $12.1{\pm}3.3$ years old, and all of the victims were female, and the number of victims who had previous mental or physical handicaps and behavior problems were 5(3.2%) and 8(5.1%) respectively. 4) The ways by which intrafamilial child sexual abuses were found were abnormal behaviors 45(28.7%), victim's own report 40(25.5%), pregnancy 18(11.5%), pain complaint 13(8.3%), other person's report 13(8.3%), and detection during examination 12(7.6%). 5) Time lags between intrafamilial child sexual abuses and hospital visits were after 1 month 97(61.8%), from 1 day to 1 week 29(18.5%), within 1 day 21(13.4%), and from 1 week to 1 month 10(6.4%). 6) Physical complications were perineal wound 93(59.2%), hymen rupture 90(57.3%), pregnancy 68(43.3%), wound of other part of body 11(7.0%), and sexually transmitted disease 4(4.5%). 7) Treatment for victims were discharge 92(58.6%), admission, operation or transfer to a bigger hospital 25(15.9%), psychiatry consult 19(12.1%), report to police(10.9%) and social work consult 3(1.9%). These results suggest that considerable numbers of physicians have had the experience of treating victims of intrafamilial child sexual abuses, and intrafamilial child sexual abuses are the major medical as well as social issue in children in Korea.

  • PDF

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

Occurrence of Stink Bugs and Pecky Rice Damage by Stink Bugs in Paddy Fields in Gyeonggi-do, Korea (경기도 벼 재배지 노린재류의 발생소장과 벼 반점미 피해)

  • Lee, Jin-Gu;Hong, Soon-Sung;Kim, Jin-Young;Park, Kyeong-Yeol;Lim, Jae-Wook;Lee, Joon-Ho
    • Korean journal of applied entomology
    • /
    • v.48 no.1
    • /
    • pp.37-44
    • /
    • 2009
  • This study was carried out to survey the occurrence of stink bugs and pecky rice grain caused by the stink bugs in paddy fields in six districts of Gyeonggi-do. In the levee of the paddy fields, 30 species of the stink bugs were collected, and the dominant species were Paromius exiguus in Hwaseong and Siheung, and Stenotus rubrovittatus in Pyeongtaek, Icheon and Paju. In the paddy fields, 23 species were collected, and the dominant species were Paromius exiguus in Siheung, and Stenotus rubrovittatus in Pyeongtaek, Icheon and Paju. P. exiguus overwintered and proliferated mainly in the west coastal region, where its host plants, Imperata cylindrica and Calamagrostis epigeois, were abundant, and then moved to paddy fields later in the season, resulting in the peak density in September in paddy area. Stenotus rubrovittatus and Cletus punctiger were abundant in paddy area in August and September, and Eysarcoris aeneus was abundant in June and July. When the stink bugs were inoculated on the rice, the rate of pecky rice caused by E. aeneus and P. exiguus at milk ripe stage was 10.2% and 4.8%, respectively, and the rate by S. rubrovittatus and P. exiguus at dough ripe stage was 4.3% and 2.7%, respectively. The damage shape of pecky rice was distinctive according to the species. The surface of pecky rice by P. exiguus was very smooth but the surface of pecky rice by E. aeneus was rough and caved. In the pecky rice by S. rubrovittatus, the spot occurred at the topside of the grain.

COMPARISON OF COMPRESSIVE STRENGTH AND SURFACE MICROHARDNESS BETWEEN FLOWABLE COMPOSITE RESIN AND GIOMER (유동성 자이오머와 복합 레진의 압축 강도 및 표면 미세 경도 비교)

  • Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.383-388
    • /
    • 2012
  • The aim of this study was to compare the compressive strength and the surface microhardness of Beautifil flow (Shofu, Kyoto, Japan) with $Filtek^{TM}$ Z350, Z350XT (3M ESPE, USA). Fifteen specimens from each material were fabricated for testing. Compressive strength was measured by using a universal testing machine at a crosshead speed of 1 mm/min. Surface microhardness values were measured by using Vickers hardness tester under 4.9 N load and 10 seconds dwelling time. The compressive strength of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $218.7{\pm}18.4$ MPa and Group 1 $Filtek^{TM}$ Z350 was $205.5{\pm}27.1$ MPa. Group 3 Beautifil flow F00 was $176.5{\pm}30.3$ MPa, and Group 4 Beautifil flow F10 was $173.4{\pm}26.2$ MPa. The compressive strength of Group 2 is higher than Group 3 and 4 (p < 0.05). The surface microhardness of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $39.1{\pm}2.1$ and Group 4 Beautifil flow F10 was $27.9{\pm}1.8$. And Group 3 Beautifil flow F00 was $23.1{\pm}1.1$, Group 1 $Filtek^{TM}$ Z350 was $20.4{\pm}0.9$. There was a statistical significant difference in surface microhardness between all groups (p < 0.05). In conclusion, the compressive strength of giomer was below the level of flowable composite resin. However, the surface microhardness of giomer is comparable to that of flowable composite resin. Giomer would be the good alternative to composite resin, if there is improvement of the compressive strength of giomer.

Stress distributions at the Periodontal ligament and displacements of the maxillary first molar under various molar angulation and rotation . Three dimensional finite element study (구치의 경사도와 회전정도가 발치공간 폐쇄시 치근막의 응력분포와 치아의 초기이동에 미치는 영향에 대한 3차원 유한요소법적 연구)

  • Kwon, Dae-Woo;Son, Woo-Sung;Yang, Hoon-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.417-428
    • /
    • 2004
  • The purpose of this study was to evaluate the stress distributions at the periodontal ligament (PDL) and displacements of the maxillary first molar when mesially directed force was applied under various molar angulations and rotations. A three dimensional finite element model of the maxiilary first molar and its periodontal ligament was made Upright position, mesially angulated position by $20^{\circ}$ and distally angulated position of the same degree were simulated to investigate the effect of molar angulation. An anteriorly directed force of 200g countertipping moment of 1,800gm-mm (9:1 moment/force ratio) and counterrotation moment of 1,000gm-mm (5:1 moment/force ratio) were applied in each situation. To evaluate the effect of molar rotation on the stress distribution, mesial-in rotation by $20^{\circ}$ and the same amount of distal-in rotation were simulated. The same force and moments were applied in each situation. The results were as follows: In all situations, there was no significant difference in mesially directed tooth displacement Also, any differences in stress distributions could not be found, in other words. there were no different mesial movements. Stress distributions and tooth displacement of the $20^{\circ}$ mesially angulated situation were very similar with those of the $20^{\circ}$ distal-in rotated situation. The same phenomenon was obserned between the $20^{\circ}$ distally angulated situation and $20^{\circ}$ mesial-in rotated situation. When the tooth was mesially angulated, or distal-in rotated, mesially directed force made the tooth rotate in the coronal plane. with its roots moving buccally, and its crown moving lingually. When the tooth was distally angulated, or mesial-in rotated, mesially directed force made the tooth rotate in the coronal plane, with its roots moving lingually and its crown moving buccally. When force is applied to au angulated or rotated molar, the orthodontist should understand that additional torque control is needed to prevent unwanted tooth rotation in the coronal plane.