• 제목/요약/키워드: 가청소음

검색결과 56건 처리시간 0.027초

방음대책 수립 후 수차발전기 소음의 저감효과 평가에 관한 연구 (A Study on the Evaluation for Reduction Effect of Hydraulic Turbine Dynamo Noise after Establishment of Soundproof Measure)

  • 윤재현;주덕훈;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.133-137
    • /
    • 2007
  • As the waterpower generation plant, the subject of this Study, is a facility that produces plenty of electricity corresponds to $196{\sim}240GWh$ annually, and in its generation process it creates a loud noise when the turbine related to the hydraulic turbine dynamo revolves, and since such loud noise must be transmitted to the dynamo room and amplified, it is effecting a lot of influences to the adjacent office and space. In such viewpoint, this Research, based on the soundproof measure presented at the preceding research, has attempted to evaluate about the effect of noise-reduction countermeasure against the hydraulic turbine dynamo using Auralizational Technique through Psycho-Acoustics Experiment. It deems that such result could be applied hereafter as the useful material when setting up a soundproof countermeasure for the hydraulic turbine dynamo room in dam.

  • PDF

축열형 전기온돌의 난방특성과 진동소음 제거에 관한 실험적 연구 (An experimental research on the heating characteristics and the elimination of noise in electric ondol for off-peak storage use)

  • 현경호;오명환;채성기
    • 전기의세계
    • /
    • 제22권2호
    • /
    • pp.75-86
    • /
    • 1973
  • 본 연구에서는 전기온돌의 안방열손실을 감소시키고 축열효과를 향상시키기 위한 방법을 검토하였으며 전기온돌에서 발생하는 진동소음을 감살시킬 수 있는 대책을 제시하였다. 저육들은 6.6[m$^{2}$] 크기의 전기온돌 model을 이용하여 건물의 구조차이와 하향열단열층의 설치유무에 따른 보온특성의 차이를 기록분석하였으며 그 결과 열전도계수가 0.03[kcal/m.hr.deg. C]정도인 내열성 Styropol과 지석 Mortar로 구성된 하향열단열층을 전기온돌의 마닥에 설치할 경우 난방부하의 감소로 인하여 축열효율이 약 2배나 향상된다는 결론을 얻었다. 또한 전기온돌공사시에 발열선을 지지할 수 있는 대각선형 Spacer를 설치하고 발열선이 매설콘크리트가 완전히 양생된 이후에 전력을 인가하면 흔히 전기온돌에서 발생하는 120-960[Hz]의 가청진동소음을 방지할 수 있다는 사실을 실험적으로 확인하였다.

  • PDF

100kW급 4병렬 스위치 인터리브 DC/DC 컨버터 개발 (Development of 100kW 4-Parallel Switch Interleaved DC/ C Converter)

  • 박성미;임상길;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.377-378
    • /
    • 2017
  • 대용량 전력변환기는 가청주파수에 해당하는 낮은 주파수 스위칭 동작으로 전력변환기 구동 시 리액터 소음에 의한 공해를 유발하고 있다. 이러한 리액터 소음공해 제거하기위해 대용량 전력변환기의 높은 주파수 전압을 리액터에 인가할 수 있는 새로운 DC/DC 컨버터 토포로지를 제안한다. 본 논문에서 제안된 토포로지는 다수의 스위치를 병렬로 연결하여 스위치 인터리브 방식에 의한 높은 등가 스위칭 동작 구현이 가능하다. 따라서 제안된 스위치 인터리브 방식은 대용량 전력변환기의 리액터 소음을 제거할 수 있을 뿐만 아니라 리액터용 용량을 저감하여 전력변환기의 에너지 밀도 증대와 단가 감수 측면에서 큰 장점을 갖고 있다.

  • PDF

제주 연안산 잿방어의 청각특성에 관한 기초적 연구 (A Fundamental Study on the Auditory Characteristics of Amberjack Seriola dumerili in the Coast of Jeju Island)

  • 서익조;김성호;김병엽;이창헌;서두옥
    • 수산해양기술연구
    • /
    • 제39권4호
    • /
    • pp.269-275
    • /
    • 2003
  • 제주도 연안 정치망의 여름철 주 어획대상인 잿방어를 실험어로 하여, 음향을 이용한 어군행동 제어, 음향순치 등 바다목장 조성을 위한 어군의 관리, 사육, 어획기술에 이용할 기초자료를 제공할 목적으로 육상수조에서 수중 가청 저주파음과 전기충격을 이용하여 음향 학습 시킨 후, 주파수와 음압을 변화시켜가면서 잿방어의 섬전도를 도출 하여 심박간격의 변화로부터 청각문턱치, 청각임계비를 측정하였다. 자연환경소음에서 잿방어의 청각문턱치는 측정 주파수 80∼800 HZ의 수중 가청음을 모두 인식하였고, 측정 주파수 200∼500 HZ 에서 청각 감도가 양호하였으며, 측정 주파수 300 Hz에서 평균 음압 94.5 dB, 표준편차 4.5 dB로 가장 낮은 청각문턱치를 보였다. 평균 음압을 65 dB, 70 dB, 75 dB의 3단계로 변화시킨 백색잡음 방성으로 측정한 잿방어의 청각임계비는 측정 주파수 80, 100, 200, 300, 400, 500, 800 HZ에서 각각 평균 음압 45.9, 52.8, 42.5, 36.4, 38.6, 39.4, 44.4 dB이었다. 측정 주파수 300 HZ, 400 HZ 그리고 500 HZ 에서는 백색잡음 중에서 측정음을 식별하는 능력이 다른 측정 주파수에 비하여 우수했다. 잿방어가 주파수 300 HZ의 수중 가청음을 충분히 인식하기 위해서는 최저 100 dB 이상의 음압 강도가 펼요하며 환경 소음이 존재하는 환경에서는 소음 스펙트럼 음압 레벨보다 약 35 dB 이상 크게 방성할 펼요가 있다.

765kV 교류 송전선로의 가청소음계산 예측식개발(I) (Predicting formula development of audible noise on a 765kV AC transmission line(I))

  • 이동일;구자윤
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

블루투스 헤드셋에서의 음질 향상에 관한 연구 - 개인 청각손실 방지측면 고려 - (Study on Sound Quality Improvement in Bluetooth Headset)

  • 김현태;박장식;송종관
    • 한국정보통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.1188-1193
    • /
    • 2009
  • 최근 젊은 층을 중심으로 블루투스 헤드셋 등 착용형 청음기기에 의한 소음성 난청을 겪고 있다. 본 논문에서는 청력 손상을 주로 일으키는 감도가 높은 주파수대에서 개인별 청각 특성과 최대가청한계를 고려하여 소리 크기를 조절함으로써 블루투스 헤드셀에서의 청각 손상을 감소하는 동시에 보다 자연스런 음량 조절이 가능한 방법을 보인다. CSR Bluetooth headset example design board(DEV-PC-1645)에 구현한 실험에서 청력 특성이 좋은 대역에서 기존 방법에 비해 보다 낮은 소리 크기에서 불편없이 인지 가능하였다. 또한 그 결과로써 과도한 대역별 소리 에너지를 줄여 청각 손상도 방지할 수 있었다.

블루투스 헤드셋용 청각 손실 방지 알고리즘 개발 (Development of Hearing Loss Reduction Algorithms for Bluetooth Headset)

  • 강정은;김현태;박장식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.383-386
    • /
    • 2009
  • 최근 젊은 층을 중심으로 블루투스 헤드셋 등 착용형 청음기기에 의한 소음성 난청을 겪고 있다. 본 논문에서는 청력 손상을 주로 일으키는 감도가 높은 주파수대에서 개인별 청각 특성과 최대가청한계를 고려하여 소리 크기를 조절함으로써 블루투스 헤드?에서의 청각 손상을 감소시키는 방법을 보인다. CSR Bluetooth headset example design board(DEV-PC-1645)에 구현한 실험에서 청력 특성이 좋은 대역에서 기존 방법에 비해 보다 낮은 소리 크기에서 불편없이 인지 가능하였다. 또한 그 결과로써 과도한 대역별 소리 에너지를 줄여 청각 손상도 방지할 수 있었다.

  • PDF

가청 주파수대 음장 변화 측정 기반 침입 감지 기술 (Intrusion detection based on the sound field variation of audible frequency band)

  • 이성규;박강호;양우석;김종대;김대성;김기현;왕세명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.187-192
    • /
    • 2010
  • In this paper, intrusion detection technique based on the sound field variation of audio frequency in the security space is proposed. The sound field formed by sound source can be detected with the microphone when the obstacle or intruder is positioned. The sound field variation due to the intruder is based on the interference of audio wave. With the help of numerical simulation of sound field formations, the increase or decrease of sound pressure level is analyzed not only the obstacle, but also the intruder. Even the microphone is positioned behind the source, sound pressure level can be increase or decrease due to the interference. Frequency response test is performed with Gaussian white noise signal to get the whole frequency response from 0 to half of sampling frequency. There are three security cases. Case 1 is the situation of empty space with and without intruder, case 2 is the situation of blocking obstacle with and without intruder, and case 3 is the situation of side blocking obstacle with and without intruder. At each case, the frequency response is obtained first at the security space without intruder, and second with intruder. From the experiment, intruder size of $50cm{\times}50cm$ can be successfully detected with the proposed technique. Moreover, the case 2 or case 3 bring about bigger sound field variation. It means that the proposed technique have the potential of more credible security sensing in real situation.

  • PDF

가청화를 이용한 소규모 다목적 홀의 음향 성능평가에 관한 연구 (A Study about Appraise on Acoustic Performance of small-scaled Multi-Purpose Hall, using Auralization)

  • 주덕훈;윤재현;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.148-152
    • /
    • 2007
  • In recent days, on account of the cultural development and the improvement of citizen's consciousness level, it is the real situation that the construction of small-scaled Multi-Purpose Hall where various cultural events could be performed, is on increasing. However, since the most of Multi-Purpose Hall had been designed and built up without any consideration on Acoustic Factor, many problems are on occurring thereat. Since those small-scaled Multi-Purpose Hall have been mostly used with the finishing material which contains a high degree of Acoustic Absorption indiscreetly, both diffusion and reflection of sound are not establishing properly, and because thereverberation of sound is very low, in case of musical performance by musical instrument, its sound hears too arid and stiff, there occurs some acoustic defect such as it becomes difficult for music appreciation with sufficient timbre, so that the capability improvement on the matter is urgently requiring situation. Therefore, this Study has tried to seize the satisfaction level about the small-scaled Multi-Purpose Hall after betterment of the acoustic performance by appraise the acoustic condition of the Hall, using Auralization Technique that can experience Virtual Acoustic Field regarding to the small-scaled Multi-Purpose Hall as its object. It is deemed that such research result could be practically used as the useful material which enables to bring a reduction effect of construction cost as well asenhancement of the acoustic performance through its presupposition?control on the acoustic problem when construction or renovation of other similar small-scaled Multi-Purpose Hall in the future.

  • PDF

가청화를 이용한 돔형 체조연습장의 음향 성능평가에 관한 연구 (A Study on Valuation of Acoustic Performance about Dome-typed Gymnastics Training Floor utilizing Auralization)

  • 윤재현;주덕훈;정은정;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.132-136
    • /
    • 2007
  • In case of indoor gymnastics training floor, in view of its characteristics, since it is simultaneously required the related smooth communication between the coach and the player, also the acoustic performance regarding to the Clearness of Music, besides the sport activity, the consideration about the acoustic character has entered the stage as an indispensable element. On such viewpoint, on the object of the recently built dome-typed gymnastics training floor, after making the optimized acoustic design with the remodeling through acoustic simulation, by means of measurement and valuation on human's psychological(sensual) degree utilizing Auralization that enables to experience the virtual sound field at the stage of design, this thesis has attempted to survey of the acoustic satisfaction degree and its reaction about the gymnastics training floor. As the result of investigation about the research on the space of object, it could be known that the valuation regarding to the acoustic performance of 'After-Improvement' was distinctly more refined than that of 'Before-Improvement'. It is now considering that such result of the study can be utilized as the useful data which enables to improve the retrenchment effect of the construction cost as well as the acoustic capability, by means of the prediction control on the acoustic problem from the stage of design, for the occasion when the similar indoor sport gymnasium is planning to build for the near future.

  • PDF