• Title/Summary/Keyword: 가이드 밸브

Search Result 10, Processing Time 0.039 seconds

Development of Transportational Guide System for Joining Small Wire with Gabion (개비온 끝단 소둔선 결합용 이송 가이드 장치 개발 연구)

  • Lee, Jong kil;Kin, Jong-Tae
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.211-225
    • /
    • 2006
  • Gabion can be used for the purpose of preventing overflow of river and side loss of road. However the manufacturing process of the gabion is manually controlled especially to the joining process at the terminal part of gabion with small diameter wire. In this paper automatic feeding guide system was designed and fabricated to make automation. The fabricated system was tested in the factory level. Pneumatic system was considered as the main idea of the feeding system. 3/2-way and 5/2-way manual control valve, eight double-acting cylinders were used. The system took 46.48 seconds during a cycle. Additional environmental noise and vibration were not detected when the machine operated at the working area. Based on the theoretical simulation and actual test the fabricated system was well controlled. The system was applied to the patent in 2006.

Analysis of Dynamic Characteristics and Performances of Vent-Relief Valve (산화제 벤트/릴리프 밸브의 동특성 해석 및 작동성능 분석)

  • Jang, Je-Sun;Koh, Hyeon-Seok;Han, Sang-Yeop;Lee, Kyung-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.6
    • /
    • pp.70-77
    • /
    • 2011
  • A ventilation-relief valve performs as a safety-valve assembly for the liquid-propellant feeding system of space launch vehicle. This valve plays a role of relieving the vaporized propellants from propellant tanks during the filling and storing stages of propellants. Also it regulates to maintain the pressure of ullage volume of on-board propellant tanks within the safety-margin during the flight. The simulation model of ventilation-relief valve is designed with AMESim to predict and evaluate the dynamic characteristics and pneumatic behaviors of valve. To validate a valve simulation model, the simulation results of the opening and closing pressures and their operating durations of valve by AMESim analysis are compared with the results of mathematical methods. In addition, the results of internal flow simulation with FLUENT are utilized to improve the accuracy of valve-modeling. This study will serve as one of reference guides to enhance the developmental efficiency of ventilation-relief valves with the various operating conditionss, which shall be used in Korea Space Launch Vehicle-II.

Technology Trend of Small Poppet Type Check Valve for Aerospace Application (항공우주용 소형 포펫 체크밸브 기술 동향)

  • Yoo, Jae-Han;Lee, Soo-Yong
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.9 no.1
    • /
    • pp.158-164
    • /
    • 2011
  • Check valves developed for aerospace applications and commercially available for the applications are investigated. The examples include the ones for launch vehicles, SSME (Space Shuttle Main Engine) and GSE (Ground Support Equipment) purges developed by NASA, requiring high reliability, and the ones by KARI. Also the commercial ones for room and cryogenic temperatures by major valve US companies. Relations of design factors such as seal materials and spring rate to principal performances like operating temperature/pressure and cracking pressure are explained. Then potential operational problems such as chatter and contaminations are explained. Also, filters, fittings for end connections and cleanliness requirements for the applications are considered.

  • PDF

Procedure and Method of Equipment Qualification for Solenoid-Operated Valves Used in Nuclear Power Plants (원전용 솔레노이드 밸브의 기기검증 절차 및 방법)

  • Lim, Byung-Ju;Park, Chang-Dae;Chung, Kyung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.683-691
    • /
    • 2011
  • In order to develop technology for an equipment qualification (EQ) test, which is an important process in localizing solenoid-operated valves used in nuclear power plants, we analyzed related regulations, test procedures, conditions, equipment, and acceptance criteria. EQ regulations for the solenoid-operated valve are classified as law, guide, and standard, and are subdivided according to test specimens and contents. The EQ test is composed of functional, normal-, and accident- condition tests. The solenoid-operated valve is aged under normal and accident conditions, which are predicted in the design conditions of a nuclear power plant, and the performance of the valve is measured by a functional test. The test method and procedure analyzed in this paper might be very useful for manufacturers as well as EQ testers.

A Study on the Cold Forging Development of Guide Valve for the Fuel Pressure Regulator (연료 압력 조절기용 가이드 밸브의 냉간 단조 개발에 관한 연구)

  • Song, Seung-Eun;Kwon, Hyuk-Hong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.331-336
    • /
    • 2012
  • This study was aimed at the design of the dies for the guide valve for the fuel pressure regulator using the computer simulation to shorten the period of production, on the basis of the process planning which was designed by the field experts. In the computer simulation, 'Deform-3d' and 'Eesy-DieOpt' have been used, which are the commercial process analysis and die design program. Through the process analysis, we could know the propriety of the forming process, the inner pressure of the die and the suitable fitting pressure between the insert and the sleeve which was not showing any positive tangential stresses in the insert. Through the simulation of die design, we could know the number of the stress ring, the diameter ratios, the stresses of the die, the shrink fitting tolerance and temperature in the condition of the already determined maximum outer die diameter of the multi-stage former. The validity of the die design using the computer simulation was analyzed by the experiments and the results were satisfactory. As the results of this study, the new and easy die design system for multi-forging has been developed.

Development of Transportational Guide System for Joining Small Wire with Gabion (개비온 끝단 소둔선 결합용 이송 가이드 장치 개발 연구)

  • Lee J.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.51-52
    • /
    • 2006
  • Gabion can be used for the purpose of preventing overflow of river and side loss of road. However the manufacturing process of the gabion is manually controlled especially to the joining process at the terminal part of gabion with small diameter wire. In this paper automatic feeding guide system was designed and fabricated to make automation. The fabricated system was tested in the factory level. Pneumatic system was considered as the main idea of the feeding system. 3/2-way and 5/2-way manual control valve, eight double-acting cylinders were used. Based on the theoretical simulation and actual test the fabricated system was well controlled. The system was applied to the patent.

  • PDF

Effect of air inflow on the performance of a 50kW-class cross-flow turbine (50kW급 횡류수차 내 공기 유입이 성능에 미치는 영향)

  • Kim, Jun-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.418-423
    • /
    • 2014
  • Small hydropower has been considered as a solution to resolve the problem of exhaustion of fossil fuel and industrial pollution. In this study, we developed and tested a Cross-Flow Turbine with two guide vanes to optimize the small hydropower for the site condition with large fluctuation of head and flow rate. Furthermore, in the condition of constant inlet head, CFD analysis was carried out to analyze the effect of air suction and valve position on the performance characteristics. The results showed that the air suction can minimize the hydraulic loss caused by the Recirculation flow in the runner passage and flow impact on main shaft so that it can increase the turbine efficiency and output power.

Qualitative Human Error Assessment for Gas Facilities (가스시설에서의 정성적 인적오류 평가)

  • Yoon Ik-Keun;Ha Jong-Mann;Oh Shin-kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.3
    • /
    • pp.70-77
    • /
    • 1998
  • This study proposes a method to facilitate the identification of human error in calling out such qualitative risk assessment in Gas plants. The main idea of this method is based on the scheme of existing qualitative risk assesment technique. The guidewords and tabular worksheet are suggested to be compatible in human error analysis. By using this method developed, the maintenance procedure of Governor system in gas valve station was analyzed to discover the human error in maintenance tasks. As a consequence, certain human errors were identified and the suggested approches proved to be adequate technique for the human error analysis.

  • PDF

A Study on the Water Hammer Arrester Considering the Way of First Assessment Test (최초의 평가시험 방법을 고려한 수격흡수기의 장치에 관한 연구)

  • Yeum, Moon-Cheon;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.53-59
    • /
    • 2015
  • Water hammering created by an unsteady flow in pipeline systems can cause excessive change in pressure, vibration, and noise. So, water hammer analysis is very important for limiting the damage caused to pipeline, pump and valve systems by operation conditions. On the other hand, water hammer arrester has been manufactured and used in order to minimize the damage caused by water hammering phenomenon in domestic, and it has been produced and installed as the low cost-oriented because of being no separate standard in the meanwhile. Therefore, our research team investigated about the standardization of water hammer arrester performance through the various methods, such as test methods for verification of one pipe, assuming the occurrence of water hammer in a water-based fire extinguishing system, separated for opening impact pressure and shut off impact pressure and for a branch pipe in order to make guideline for water hammer arrester performance. And finally, verified the performance of the water hammer pressure as the simple mechanical way using the U-shaped pipe and a test weight, so KFI standards for the water hammer arrester could be established.

asset management framework for low-carbon water distribution system (저탄소 상수도 관망을 위한 자산관리 체계 구축)

  • Kim, Beomjin;Lee, Jaeyeon;Lee, Seungyub
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.183-183
    • /
    • 2022
  • 최근 몇 년 동안 기후변화에 대응하기 위한 탄소중립 혹은 저탄소 운영의 중요성이 강조되어왔다. 상수도 관망은 직접적인 탄소 배출 시설물은 아니지만, 상수도 관망의 운영 그리고 구성요소의 제조부터 폐기까지의 전 생애주기 동안 막대한 양의 에너지를 사용하는데, 이러한 에너지의사용이 탄소 배출에 간접적인 영향을 주는 것으로 알려져 있다. 특히 수자원공사에 따르면, '17년 기준 수도사업 관련 전기 사용에 따른 간접 배출이 70만tCO2eq에 이르는 것으로 보고되고 있어, 에너지의 효율적인 운영 및 자산관리 체계의 필요성이 커지고 있는 실정이다. 상수도 관망의 에너지 효율에 영향을 주는 요인은 크게 구성요소의 노후와 누수로 구분할 수 있다. 본 연구에서는 상수도 관망 관로 별 노후와 누수 여부를 판단하여 교체 전략을 수립할 수 있는 자산관리 모형을 제안하고 관로별 에너지 효율을 시각화하여 전반적인 자산관리에 근거를 제시하고자 한다. 모형은 최적화 기법을 통한 관로별 기능적 노후도 산정 및 누수 탐지, 관만 내 누수 지역화, 에너지 효율 시각화 등 총 3개의 모듈로 구성되어 있다. 제안한 모형은 고도의 차이가 큰 국내 D시 가상 관망에 적용하였다. 해당 관망에 다양한 관로의 노후 및 누수 상황을 가정하여 가상의 데이터를 생성하고 이를 토대로 관로별 기능적 노후와 누수 조건을 고려하여 해당 모형을 검증한다. 또한, 노후와 누수에 따른 가상 상황별 관로의 자산관리 의사결정 예시를 제공하여 향후 모형의 활용에 대한 가이드 라인을 제시한다. 마지막으로 관망 내 설치된 감압밸브를 터빈으로 전환하여 관망 운영 단계에서 무의미하게 소산되는 열에너지를 회수하는 방안을 검증하였다. 최적화 기법을 통해 비용 대비 최적 터빈 설치 지역을 선정하였고 향후 터빈 설치에 고려해야 할 사항을 정리한다. 본 연구에서의 결과는 향후 종합적인 저탄소형 상수도 관망을 위한 초석을 제공할 것으로 기대한다.

  • PDF