• Title/Summary/Keyword: 가열 성능

Search Result 398, Processing Time 0.027 seconds

Evaluation of thermal-hydro-mechanical behavior of bentonite buffer under heating-hydration condition at disposal hole (처분공 가열-수화 조건에서 벤토나이트 완충재의 열-수리-역학적 거동 특성 평가)

  • Yohan Cha;Changsoo Lee;Jin-Seop Kim;Minhyeong Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.175-186
    • /
    • 2023
  • The buffer materials in disposal hole are exposed to the decay heat from spent nuclear fuels and groundwater inflow through adjacent rockmass. Since understanding of thermal-hydro-mechanical-chemical (T-H-M-C) interaction in buffer material is crucial for predicting their long-term performance and safety of disposal repository, it is necessary to investigate the heating-hydration characteristics and consequent T-H-M-C behavior of the buffer materials under disposal conditions considering geochemical factors. In response, the Korea Atomic Energy Research Institute developed a laboratory-scale 'Lab.THMC' experiment system, which characterizes the T-H-M behavior of buffer materials under different geochemical conditions by analyzing heating-hydration process and stress changes. This technical report introduces the detail design of the Lab.THMC system, summarizes preliminary experimental results, and outlines future research plans.

발사전 가열 해석 - Delta II 자료 분석

  • Choi, Sang-Ho;Kim, Seong-Lyong;Kim, In-Sun
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.126-134
    • /
    • 2005
  • Before the launch, launch vehicle is set up a few days ago at launch pad to check process and to supply fuels, etc. During the prelaunch process, the payload is exposed to the thermal environments. The purpose of a prelaunch thermal analysis is to predict maximum/minimum liftoff temperature of payload fairing and to evaluate air conditioning performance. The prelaunch thermal analysis of Delta II PLF is performed using Sinda/fluint, general thermal/fluid analyzer. The results are analyzed and compared with Delta II report.

  • PDF

Measurement of temperature distribution of the stamper and estimation of injection-molded light guide panel performance in E-MOLD process (금형가열방식을 이용한 사출성형금형의 온도분포 측정과 E-MOLD금형을 이용한 도광판 사출품에 대한 성능 평가)

  • Kim, Young-Kyun;Kim, Dong-Hak
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.358-361
    • /
    • 2008
  • 본 논문에서는 열화상촬영기 및 온도분포 해석 프로그램을 이용하여 금형가열온도와 실제 금형온도의 온도편차를 비교하여 금형가열 시 Stamper 표면의 온도분포를 해석하였다. 또한 전열가열방식(E-MOLD)을 이용하여 복합기능 도광판(Prismless LGP)을 제조하였고, 금형온도에 따른 복합기능 도광판(Prismless LGP)의 광특성 평가를 하였다. 그 결과 금형온도가 증가할수록 패턴 전사성 향상으로 인해 휘도 또한 증가하였고, 특히 유리전이온도($140^{\circ}C$) 이상에서 크게 상승하였다.

  • PDF

Flame Resistance and Durability of Compressed Structural Wood through Microwave Heat Drying Method (마이크로파 가열건조법에 의한 압축 구조용 목재의 방염 및 내구성)

  • Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.162-170
    • /
    • 2011
  • As the result of implementing a treated material test and durability test after quickly drying S.P.F. species, a type of softwood structural material, within a short period time, soaking it in liquid phosphate flame proof agent for an hour, microwave heating it, and compressing it from 3.8cm to 1cm, when setting the appropriate heating time of microwave heating at 7 minutes at 5kW, it is observed that it satisfies the target water content (4~5%). It is shown that in a water content measurement of the wood that is compressed after being softened by soaking in the flame proof agent, drying and heating at 3kW for 9 minutes, all specimens satisfied 12~14%, the appropriate water content for exterior wood. Also, it is shown that in terms of the flame performance obtained through a flame resistance treatment of the compressed wood and a treated material test, the specimen soaked in flame proof agent for 30 minutes was the most excellent, and that the performance test result of the compressed wood in all areas, such as nail withdrawal resistance, compression, bending strength, and shearing strength, were all improved in their mechanical features to twice to three times better performances.

The Effects of Various Burner Array on Workpiece and Gas Temperature in a Continuous Reheating Furnace (연속식 가열로에서 버너배열에 따른 소재 및 가스온도의 영향)

  • Kim, Kang-Min;Jeon, Chung-Hwan;Yoo, In;Kim, Gyu-Bo
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.23-31
    • /
    • 2017
  • Numerical study was conducted for the effects of various burner array on the workpiece and the gas temperature in a continuos reheating furnace. Under the same conditions which were the total heat of combustion, the heat capacity of unit burner, the number of burner and burner array were changed to be applied the furnace. The behavior of workpiece temperature and gas temperature in a furnace were evaluated for the effects as function of the changed conditions. A continuous reheating furnace designed for 110 tons/day of production capacity was applied in this study. The furnace which has several gas burners is designed to heat a workpiece. By this study, the better condition was confirmed than the existing designed condition.

A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method (강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구)

  • Park, Hyeong-Su;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.122-126
    • /
    • 2017
  • The aim of this study was to develop a device for solving the heating problem of living space using heated air, utilizing a simple air heater type collector for solar energy. At the present time, this study assessed the possibility of a development system through theoretical calculations for the amount of available energy according to the size change of the air-heated solar energy collector. To produce and supply hot water using the heat energy of the sun, hot water at $100^{\circ}C$ or less was produced using a flat or vacuum tube type collector. The purpose of this study was to research the air heating type solar collector that utilizes heating energy with heating air above $75^{\circ}C$, by designing and manufacturing an air piping type solar collector that is a simpler type than a conventional solar collector system. The analysis results were obtained for the generated air temperature ($^{\circ}C$) and the production of air (kg/h) to determine the performance of air heating by an air-heated solar collector according to the heat transfer characteristics in the collector of the model when a specified amount of heat flux was dropped into a solar collector of a certain size using PHOENICS, which is a heat flow analysis program applying the Finite Volume Method. From the analysis result, the temperature of the air obtained was approximately $40.5^{\circ}C$, which could be heated using an air heating tube with an inner diameter of 0.1m made of aluminum in a collector with a size of $1.2m{\times}1.1m{\times}0.19m$. The production of air was approximately 161 m3/h. This device can be applied to maintain a suitable environment for human activity using the heat energy of the sun.

Evaluation of Residual Bond Stress between Carbon-fiber Reinforced Polymer and Steel Rebar Using Ultra-High-Performance-Concrete after Elevated Temperature (초고강도 콘크리트를 활용한 고온가열 이후의 탄소 보강근과 철근의 잔류 부착성능 평가)

  • Yoo, Sun-Jae;Lee, Ho-Jin;Yuan, Tian-Feng;Yoon, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.169-176
    • /
    • 2021
  • In this study, pull-out tests were conducted at room temperature, 150 ℃ and 250 ℃ to evaluate the residual bond strength of carbon fiber reinforcement polymer, CFRP after elevated temperature and deformed steel rebar of D10 and D13 were also evaluated after the high temperature heating for comparison. As a result of the experiment, the bond strength of the CFRP after 150 ℃ and 250 ℃ decreased by 9.94 % and 41 %, respectively. On the other hand, after thermal heating, both the steel rebar of D10 and D13 had a lower rate of reduction in bond strength than that of the CFRP. Also slip at the maximum bond strength also decreased after the heating for both the CFRP and the rebars. Through it, the correlation between the bond strength and the slip reduction due to thermal heating was confirmed and bond slip models were presented. Finally the experimental result was evaluated as relative bond strength to identify the residual bond performance of the CFRP and the rebar after the heating was confirmed by comparing with the existing test result of the bond strength after elevated temperature.

Performance Characteristics of 0.4 MW Class Arc-Heated Plasma Wind Tunnel (0.4 MW 급 아크가열 플라즈마 풍동의 성능특성)

  • Oh, Philyong;Chinnaraj, Rajesh Kumar;Hong, Seong Min;Shin, Eui Sup;Choi, Seong Man
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.115-124
    • /
    • 2018
  • Thermal protection materials (TPMs) are very crucial for the survival of any re-entry space vehicles. One of the systems used for rigorous validation of TPMs is an enhanced Huel type segmented arc-heated plasma wind tunnel. A 0.4 MW class arc-heated plasma wind tunnel has been constructed at Chonbuk National University which is capable of producing high enthalpy supersonic flow. In this paper we have studied the characteristics of plasma flow according to power and mass flow parameters.

Performance Prediction and Economic Assessment of Atmospheric Pressure MCFC/Gas Turbine Hybrid System with Indirect Turbine Firing (터빈 간접가열식 상압형 MCFC/가스터빈 복합시스템의 성능예측과 경제성 평가)

  • Choi, Joo Hwan;Kim, Tong Seop;Kwak, Bu Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.31-39
    • /
    • 2014
  • The performance of fuel cell/gas turbine hybrid systems is highly affected by system configuration. In this study, the performance of a hybrid system combining a molten carbonate fuel cell (MCFC) and an indirectly fired gas turbine was predicted. Firstly, general performance trends of the hybrid system depending on major design parameters were examined. Then, the most feasible design options with the least impact on the MCFC stack design conditions were drawn. The economic advantage of the hybrid system over the basic MCFC only system was evaluated.