• Title/Summary/Keyword: 가연

Search Result 480, Processing Time 0.02 seconds

친환경 가글캡슐

  • Jeong, Gyeong-Rok;Kim, Yu-Heon;Gwon, Su-Hyeon;Kim, Ga-Yeon
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2019.10a
    • /
    • pp.236-236
    • /
    • 2019
  • PDF

Fire Tests for Representative Combustibles in Residential Facilities for the Development of Field Commander Training Content (현장지휘관 훈련 콘텐츠 개발을 위한 주거목적시설 대표 가연물 실물화재시험)

  • Moon, Min-Ho;Yang, So-Yeon;Han, Kuk-Il;Lee, Ji-Hee;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, the fire patterns, heat emissions, and smoke generated by means of fire tests developed for representative combustibles in residential facilities were analyzed from among seven fire types. These combustibles were selected in a previous study to simulate real-world situations and professionalism required while dealing with these types of fires and develop the field commander training content. Consequently, the maximum heat dissipation was recorded as 728.6 kW, followed by the dissipation measured from the combination of a mattress and electric blanket, desk and chair, and TV and mattress. The total heat emission of sofas (226.2 MJ) and the combination of mattress and electric blanket (2,259.5 ㎡) was recorded. In this study, the scope of the tests was limited to the fire characteristics and characteristics of the combustibles, and it is expected that a simulation using various data acquisition methods and FDS would be performed and evaluated at a later stage.

Fire Extinguishing Capability of an Automatic Spreading Fire Extinguisher in Accordance with Horizontal Distance from a Fire Source (자동확산소화장치의 이격거리에 따른 소화성능평가연구)

  • Kwark, Ji-Hyun;Kim, Dong-Suk;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.38-43
    • /
    • 2013
  • An automatic spreading fire extinguisher usually installed in a closed area like a boiler room, a laundry store or a restaurant's kitchen room is one of the fire protection equipments. This extinguisher automatically discharges dry powder, extinguishing fire. As this extinguisher has the extinguishing capability applicable to the nominal protection area, objects outside the area cannot be properly extinguished. However only its number is being requested according to the floor area in the related laws, and the extinguishing capability depends on the distance from a fire source. In this study we tried to investigate the extinguishing capability of the automatic spreading fire extinguisher in accordance with horizontal separation distance from a fire source. It appeared that the maximum horizontal separation distance was about 30 cm for both class A and B fire to be certainly extinguished.

A Study on Features of Fire and Change of Extinguishing Capacity of Sprinkler Equipment Against Fire at a Traditional Market (재래시장에서의 화재조건에 따른 스프링클러설비의 소화성능변화와 화재특성에 관한 연구)

  • Park, Jin-Woo;Jeon, Gyu-Yeob;Na, Wook-Jung;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.128-138
    • /
    • 2008
  • Lots of products stocked at a traditional market are made of rubbers, synthetic fibers and plastics which when on fire, emit high heat to easily ignite nearby inflammables. And shops are not divided by fireproof partitions but by combustible curtains, which contributes to a possibility of a conflagration. In this study, danger and weak factors on fire at a traditional market was analyzed. Non-existence of partition between shops and the height of piled inflammables are set as danger factors and change of extinguishing capacity of sprinklers was analyzed using fire dynamics simulator. As a result, it turned out that partitions between shops and high-piled inflammables reduced watering radius of sprinklers and increased the size of fire and distribution of temperature.

Characteristics of Heat Release Rate Predictions of Fire by a Fire Dynamics Simulator for Solid Combustible Materials (복합소재 고체 가연물의 화재 시 발생되는 열방출률의 FDS 예측 특성)

  • Nam, Dong-Gun;Hong, Ter-Ki;Ryu, Myung-Ho;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.22-28
    • /
    • 2020
  • The heat release rate (HRR) of fire for solid combustibles, consisting of multi-materials, was measured using the ISO 9705 room corner test, and a computational analysis was conducted to simulate the fire using an HRR prediction model that was provided by a fire dynamics simulator (FDS). As the solid combustible consisted of multi-materials, a cinema chair composed primarily of PU foam, PP, and steel was employed. The method for predicting the HRR provided by the FDS can be categorized into a simple model and a pyrolysis model. Because each model was applied and computational analysis was conducted under the same conditions, the HRR and fire growth rate predicted by the pyrolysis model had good agreement with the results obtained using the ISO 9705 room corner test.

Physical Properties of Aramid and Aramid/Nylon Hybrid ATY for Protective Garments relative to ATY Nozzle Diameter (ATY 노즐 직경에 따른 방호의류용 아라미드와 아라미드/나일론 하이브리드 ATY사의 물성변화)

  • Choi, La Hee;Kim, Hyun Ah;Kim, Seung Jin
    • Fashion & Textile Research Journal
    • /
    • v.15 no.3
    • /
    • pp.437-443
    • /
    • 2013
  • This paper investigates the physical properties of aramid and aramid/nylon hybrid air jet textured filaments for protective garments relative to ATY nozzle diameters. Three types of para-aramids(840d, 1,000d, 1,500d) and nylon(420d) filaments were prepared; in addition, 840d aramid/420d nylon and three kinds of aramid filaments were texturized with a variation of air jet nozzle diameters(0.6, 0.75, 1 and 1.2 mm) on the AIKI air jet texturing machine. The measured physical properties of 16 specimens are as follows. The linear densities of aramid and aramid/nylon hybrid ATY increased with a larger nozzle diameter. The tenacity and initial modulus of aramid and hybrid ATY linearly decreased with a larger nozzle diameter; in addition, the breaking strain increased with the nozzle diameter. The dry and wet thermal shrinkage of hybrid ATY increased with a larger nozzle diameter from 0.6 mm to 1 mm and then decreased at a nozzle diameter of 1.2 mm (which seems to be a critical diameter). The wet and dry thermal shrinkage of aramid/nylon hybrid ATY are influenced by the nylon part of the hybrid yarns because the wet and dry thermal shrinkages of aramid ATY are less than 0.2%. The instabilities of aramid and aramid/nylon hybrid ATY were not influenced by the air jet nozzle diameter; however, they increased with the linear density of ATY.

Investigation of an Apartment Fire - Site Surveys and Burn Tests for Estimation of the Progress on Initial Fire Spread - (공동주택의 화재조사 - 현장조사 및 연소실험에 의한 초기 화재확대과정 추정 -)

  • Nam, Dong-Gun;Hasemi, Yuji
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.120-129
    • /
    • 2009
  • Identification of the exact cause of a building fire is generally difficult, because the source and initially ignited objects are often severely damaged or even lost during the early stages of the fire. We made an experimental attempt to reasonably estimate the burning during the very early stages of a fire, and identify its source and causes. The case we studied was an apartment fire, which occurred in Tokyo, in July 2002. The fire was extinguished just after flashover, and the on-site investigations suggested the fire started from the TV and TV stand, which had been damaged so severely that it was difficult to conclude that the TV was the ultimate cause of the fire, simply from the on-site investigation. We conducted a series of burn tests using a TV and other products identical to those actually used in the apartment. Tests were set-up and procedures were carefully studied to recreate the conditions of the articles that remained, and of the room itself. The tests demonstrated that the conditions in the apartment could be recreated only when the fire started inside the TV and came into close contact with dresser.

Dispersion Characteristics of Hydrogen Gas by the Effect of Leakage Hole Size in Enclosure Space (누출공 크기에 따른 밀폐공간 내 수소 가스의 확산 특성)

  • Choi, Jinwook;Li, Longnan;Park, Chul-Woo;Lee, Seong Hyuk;Kim, Daejoong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.26-35
    • /
    • 2016
  • As a potential clean energy resource, the production and consumption of hydrogen gas are expected to gradually increase, so that hydrogen related studies are also increasing. The thermal and chemical properties of hydrogen result in its high flammability; in particular, there is a high risk if leaks occur within an enclosed space. In this study, we applied the computational fluid dynamics method to conduct a numerical study on the leakage behavior of hydrogen gas and compared these numerical study results with an experimental study. The leakage hole diameter was selected as an important parameter and the hydrogen gas dispersion behavior in an enclosed space was investigated through various analytical methods. Moreover, the flammable regions were investigated as a function of the leakage time and leakage hole size. We found that the growth rate of the flammable region increases rapidly with increasing leakage hole size. We also investigated the relation between the mass flow rate and the critical time when the hydrogen gas reaches the ceiling. The analysis of the monitoring points showed that the hydrogen gas dispersion behavior is isotropic and independent of the geometry. We found that the concentration of gas in an enclosed space is affected by both the leakage flow rate and amount of gas accumulated in the enclosure.

An Experimental Study on the Influence of the Spread of Firebrand on Building Exterior Materials and Roofing Materials in Urban Areas (도심지 인접 산불의 불티 확산이 건축물 외장재와 지붕재에 미치는 영향에 관한 실험적 연구)

  • Min, Jeong-Ki
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.617-626
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the fire srpead risk of building exterior and roofing materials due to the firebrand of forest fire occurring in the urban areas. Method: In order to achieve this research purpose, by selecting building materials used for exterior and roofing materials of buildings, the time to ignition, total heat release, and heat release rate were investigated, and a forest fire firebrand system was established to the possibility of fire spread was confirmed. Result: As a result of the cone calorimeter test, the roofing material had a similar or faster ignition time due to radiant heat compared to the exterior material with the steel plate exposed to the outside, and showed a higher heat release rate and total heat release than the exterior material. Although it was affected by the flammable material, it was confirmed that it did not spread easily due to the limited amount of combustible material, and carbonization marks appeared inside. Conclusion: The cone calorimeter test method has been shown to be useful in understanding the combustion characteristics of building materials by radiant heat, but the fire spread due to a firebrand in a forest fire is directly affected by the flame due to the ignition of surrounding combustibles, so finding a direct correlation with the cone calorimeter method is difficult. It is judged that the roof material may be more vulnerable to the spread of fire due to the fire than the exterior material.