• Title/Summary/Keyword: 가연

Search Result 483, Processing Time 0.022 seconds

Whitening and Antioxidative Effect of Rice Bran Fermented by Bacillus subtilis (발효된 미강의 항산화 효과 및 미백 효과)

  • Chae, Ga-Yeon;Kwon, Ryun-Hee;Jang, Min-Woo;Kim, Min-Jung;Ha, Bae-Jin
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.2
    • /
    • pp.153-159
    • /
    • 2011
  • In this study, we investigated rice bran fermented by Bacillus subtilis (RFB) at $40^{\circ}C$ for 36 h to develop a new natural antioxidant and whitening agent for new natural cosmetics. RFB showed reactive oxygen species (ROS) scavenging activities in 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical, superoxide radical scavenging activities and hydroxyl radical scavenging activities at a concentration of $100 \;{\mu}L$/mL. DPPH, superoxide radical scavenging activities and hydroxyl radical scavenging activities were higher in the RFB than in the RB. Inhibitory activity on auto-oxidation of linoleic acid is also highest at a concentration of $100 \;{\mu}L$/mL. RFB showed the higher inhibitory activity than RB in auto-oxidation. RFB reduced intracellular tyrosinase activity about 80 % at a concentration of $100 \;{\mu}L$/mL. Therefore, we suggest that RFB could be used as a useful antioxidant and whitening agent.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

A Study on Mapping Forest Fire Risk Using Combustion Characteristic of Forest Fuels : Focusing on Samcheok in Gangwon-do (산불연료의 연소특성을 활용한 산불위험지도 작성에 관한 연구 : 강원도 삼척 시를 중심으로)

  • Lee, Haepyeong;Park, Youngju
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.296-304
    • /
    • 2017
  • In order to predict about forest fire behavior we constructed a database for combustion characteristic of forest fuels in Samcheok, Gangwon-do and prepared fire risk map and fire risk rating using GIS method in this study. For the mapping autoignition temperature, ignition time, flame duration time, total heat release and total smoke release are selected as the standardized parameters and the overall risk rating was made up of the ignition risk parameters(autoignition temperature, ignition time) and the spread risk parameters(flame duration time, total heat release, total smoke release). Forest fire risk was classified into 5 grades and lower grade of fire risk rating mean to correspond to more dangerous forest fire. As a result, the overall risk rating of Samcheok was classified into three grades from 1 to 3 and Nogok-myeon and Miro-myeon were turned out the most dangerous areas for forest fire. Because of the colony of pine and oak trees and the higher fire loads, the flame propagation will be carried out quickly in these areas.

Numerical Study on Characteristics of Gas Leakage in an Underground Combined Cycle Power Plant (지하 복합발전 플랜트 내부의 가스 누출 특성에 대한 수치해석 연구)

  • Bang, Joo Won;Sung, Kun Hyuk;Ryou, Hong Sun;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.594-600
    • /
    • 2016
  • The present study numerically investigated the gas leakage characteristics in a simplified underground combined cycle power plant. The effect of obstacles near a crack location on the gas concentration in the confined space was analyzed by using the lower flammable limit (LFL) of methane gas. When the jet flow was close to the vertical walls, the longitudinal leakage distance increased by about 60% (when an obstacles was present) compared to the case without any obstacle, because these obstacles prevented transverse flows. In addition, when an air filter was installed near to the trajectory of the gas flow, the longitudinal leakage distance was similar to the distance between the crack and obstacle, whereas the transverse leakage distance increased up to 8 times compared to the case without any obstacle. As the jet flow impacts on the obstacle and changes its direction, the gas flows recirculate. Therefore, it is necessary to consider the effect of the structure and facility locations on the trajectory of the jet flow to propose an accident prevention system in confined spaces.

A study on the hydration of sludge from limestone washing process in a steel making factory (제철소 석회석수세슬러지의 수화반응 특성에 관한 연구)

  • Ahn, Ji-Whan;Kim, Ka-Yeoun;Kim, Hwan
    • Resources Recycling
    • /
    • v.3 no.3
    • /
    • pp.32-49
    • /
    • 1994
  • Hydration process is one of the basic carbonation system. Limestone sludge produced in Pohang Iron & Steel Co., Ltd. We tested for identify of hydration characteristics. The result obtained in this study can be summarized as follows; 1. The classify of limestone sludge is type of ground calcium carbonate(-3mm+325mesh)and the major mineral of calcite, and further more high grade(CaO 51%), fine powder(15~22$\mu\textrm{m}$). 2. Limestone sludge mixed two process sludge, first one is washing process sludge and the other one is wet collect kiln dust. The composition rate is about 8:2. Wet collect kiln dust is major mineral of calcite, too. But the sludge is assumed to one by quick lime, slaked lime and unreacted natural limestone. So, the ideal process is dividing of the washing process sludge and wet collect kiln dust. 3. We manufactured of slaked lime from limestone sludge. To investigate the effect of hydration reactor, the experiments was done with various reactor type as magnetic stirrer, shaking incubator and ultrasonic vibration reactor, respectively. Generally, ultrasonic vibration reactor is excellent hydration for limestone sludge and produced very fine slaked lime powder with ideal distribution. 4. The optimum condition is 10% pulp density, when the manufacture of fine slaked lime powder by ultrasonic vibration reactor. And hydration times to compare the results of the study with ultrasonic vibration reactor of generalized most short time(5~10 min). 5. Finally, the dispersive characteristics of slaked lime powder measured 1~5 $\mu\textrm{m}$ from limestone sludge were compared with those of natural limestone ones(10~20$\mu\textrm{m}$), in order to check applicability of slaked lime with hydration process from limestone sludge.

  • PDF

Synthesis and Crystallization of Amorphous Calcium Carbonate by Gas-Liquid Reaction of System Ca($OH_2 O$)-$H_2$-$CO_2$ (Ca($OH_2$)-$H_2 O$-$CO_2$계의 기액반응으로부터 비정질 탄산칼슘의 합성 및 결정화)

  • Im, Jae-Seok;Kim, Ga-Yeon;Im, Goeng
    • The Journal of Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.73-87
    • /
    • 2004
  • The synthesis and crystallization of amorphous calcium carbonate($CaCO_3$.$nH_2 O$) obtained from gas-liquid reaction between aqueous solution of calcium hydroxide and carbon dioxide at 15~$50^{\circ}C$ are investigated by electrical conductometry, XRD and TEM. The results are as follows: The initial reaction products prior to the formation of precipitated calcium carbonate is amorphous calcium carbonate. The electrical conductivity values in the slurry are decreased during the formation of amorphous calcium carbonate which covers particle surface of calcium hydroxide and retard the dissolution of calcium hydroxide into the solution. that amorphous calcium carbonate is unstable in the aqueous solution and crystallizes finally to calcite by the through-solution reaction. While amorphous calcium carbonate crystallizes into chain-like calcite, the conductivity values are recovered rapidly and the apparent viscosity of slurry containing higher concentration of calcium hydroxide increase. At below pH 9.5, chain-like calcite separates into individual particles to form precipitated calcium carbonate. The formation and synthetic temperature range of amorphous calcium carbonate is most suitable a primary decreasing step(a-step) at $15^{\circ}C$ in the electrical conductometry.

  • PDF

Development of Eco-friendly Combustion Process for Waste 2,4,6-trinitrotoluene (폐 2,4,6-trinitrotoluene의 환경 친화적 연소처리공정 개발)

  • Kim, Tae Ho;An, Il Ho;Kim, Jong Min
    • Clean Technology
    • /
    • v.27 no.3
    • /
    • pp.247-254
    • /
    • 2021
  • In this study, an eco-friendly combustion process of waste 2,4,6-trinitrotoluene (TNT: 2,4,6-trinitrotoluene) was developed, and fundamental data for the quantity of the organic matter in the final combustion residues is presented. Because complete combustion of TNT is not possible theoretically, the combustion process was optimized to reduce organic matter content in the combustion residue by performing measures such as heating time changes, addition of propellant material, and after treatment using a high-temp electrical furnace. From the results, it was confirmed that the organic matter content in the residue could be decreased to 7 ~ 10% with each method. The quantity of the organic matter could be minimized by optimizing the combustion conditions of the process. With only a combustion time increase, the amount of organic matter in the combustion residues was measured at about 9 wt%. The environmental friendliness of the final exhaust gas was also confirmed by real time gas component analyses. In addition, the organic contents could be reduced by a further 2 wt% by applying an additional heat treatment using an external electric furnace after the first incineration treatment. In the combustion process of propellant added waste TNT, it was found that various TNT wastes could be treated using the same eco-friendly protocols because the organic content in the residue decreased in accordance with the amount of propellant. The amount of the organic matter content produced by all these methods fulfilled the requirements under the Waste Management Act.

A Pilot Study on Development of Market-Driven Construction Cost-Reference (민간 중심 BOTTOM-UP 방식 건설공사 단가 수립 체계 개발을 위한 기초 연구)

  • Kim, Kyeong-Baek;Lee, Ga-Yeoun;Kim, Sang-Bum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.151-159
    • /
    • 2021
  • Cost information in the Korean construction industry is mainly controlled by the government agencies. However, there have been wild-spread speculations among participants on the adequacy of these unit prices and difference with the actual market condition. Korean public-led unit prices are developed using mainly a top-down approach by a few designated public institutions. Due to the rapid fluctuations in market prices and high-volume of information, it is impossible for a few public institutions to properly consider market conditions. However, there are almost none private cost reference while many are available in other countries to supplement the public cost references. Needs for private cost references have recognized, and this study can be seen as a pilot study to support them. This study attempts to identify the problem areas of Korean cost references and to provide guidance by benchmarking other countries. This study has confirmed the need of developing market-driven cost references by employing a bottom-up approach in which a large number of various construction participants are fostered to provide their own cost information and share with others. It is envisioned that this study provides foundations for further study on the development on-line construction market platform based on abundant and appropriate cost information.

Measurement of flash point for binary mixtures of Ethanol, 1-propanol, 2-propanol and 2,2,4-trimethylpentane (Ethanol, 1-propanol, 2-propanol 그리고 2,2,4-trimethylpentane 이성분 혼합계에 대한 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • Flammable substances, such as organic solvents, are commonly used in laboratories and industrial processes. The flash point of flammable liquid mixtures is a very important parameter for characterizing the ignition and explosion hazards, and the flash points of mixtures of $C_2{\sim}C_3$ alcohols and 2,2,4-trimethylpentane were measured in the present study. The 2,2,4-trimethylpentane is an important component of gasoline and is frequently used in the petroleum industry as a solvent. Lower flash point data were measured for the binary systems {ethanol + 2,2,4-trimethylpentane}, {1-propanol + 2,2,4-trimethylpentane}, and {2-propanol + 2,2,4-trimethylpentane}. The flash point measurements were carried out according to the standard test method (ASTM D3278) using a Stanhope-Seta closed cup flash point tester. The measured flash points were compared with the predicted values calculated using Raoult's law and also following $G^E$ models: Wilson, Non-Random Two Liquid (NRTL) and UNIversal QUAsiChemical (UNIQUAC). These models were able to predict the experimental flash points for different compositions of {$C_2{\sim}C_3$ alcohols + 2,2,4-trimethylpentane} mixtures with minimal deviations. The average absolute deviation between the predicted and measured lower flash point was less than 1.28 K. A minimum flash point behaviour was observed in all of the systems as in the many observed cases for the hydrocarbon and alcohol mixtures.

Isolation and characterization of bacteriophages for the control of Shiga Toxin-producing E. coli (시가 독소 생성 대장균의 제어를 위한 박테리오파지의 분리와 특성 분석)

  • Lim, Ga-Yeon;Park, Do Won;Lee, Young-Duck;Park, Jong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.6
    • /
    • pp.594-600
    • /
    • 2018
  • Shiga toxin-producing Escherichia coli (STEC) is an important pathogenic bacterium. To control STEC, the characteristics of the ECP33 and NOECP91 coliphages, which belong to the Myoviridae family, were analyzed. The host inhibition range for a total of 44 STEC strains was 45.5% for ECP33 and 65.9% for NOECP91. ECP33 and NOECP91 were relatively stable at $65^{\circ}C$, 50 ppm of sodium hyperchlorite, and a pH value of 4-10. However, the two phages were susceptible to a temperature of $70^{\circ}C$. NOECP91 was killed within 1 h after exposure to 30% ethanol, but ECP33 showed high tolerance even after exposure to 70% ethanol for 1 h. Interestingly, the inhibition of STEC growth according to the multiplicity of infection of 0.1 was confirmed until no growth was observed after 10 hours of culture with the phages. Therefore, the ECP33 and NOECP91 phages may be applied as a biological control agent for Shiga toxin-producing E. coli.