• Title/Summary/Keyword: 가압 시스템

Search Result 313, Processing Time 0.031 seconds

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Damper Locationfor Uniform Air Egress Velocity in the case of Two Fire Doors (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 2개 출입문이 존재할 경우 균일한 방연풍속을 얻기 위한 댐퍼 위치 선정방법)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • Vestibule pressurization system should produce uniform air egress velocity to prevent the intrusion of smoke into escape route when fire accidents occur inside a building and fire doors are open for evacuation of people. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where two doors are installed varying the location of a damper and louver angle. From simulations, we found that when the damper in the vestibule is located at the center of the wall opposite to two fire doors, the uniform air egress velocity can be obtained.

Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires (공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구)

  • Kim, Byeongjun;Yang, Ying;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.78-86
    • /
    • 2020
  • In this study, numerical simulations were performed on the air egress velocity of pressurization systems in an ancillary room when a fire occurred in an apartment house. The relationship between the air supply flow rate of a damper and air egress velocity at a fire door is predicted to be linear. Additionally, a minimum flow rate of the damper, which meets national fire safety standards for air egress velocity, i.e., 0.7 m/s can be estimated. Air egress velocity at the fire door is analyzed according to the supply air direction and installation height of the damper. When the damper has an upward supply air direction and is installed at a high level, the egress velocity at the top section of the fire door is larger, whereas the soot concentration at the ancillary room is lower than when the supply direction of the damper is downward. Therefore, it is found that increasing the air egress velocity at the top section of the fire door helps to efficiently prevent the inflow of smoke.

The Review of Saturn V 1st Stage (S-IC) Propulsion System (Saturn V 발사체 1단(S-IC) 추진기관 시스템 연구)

  • Hong, Yonggi;Kim, Cheulwoong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • It had been almost a half century since Apollo Mission was ended. However, in these days, a lot of researches are being conducted for restoration and making improvements in technologies used in Saturn V rocket's development. This study reviews the first stage of Saturn V rocket(S-IC), from development history to technologies in various subsystems such as engine purge system, POGO suppression system, hydraulic and pneumatic control system, propellant dispersion system, telemetry system and retrorocket system. Understandings of S-IC stage's operation systems would be helpful in understanding of launch vehicle system and reduction of time and cost in future development process.

Pressure Control of Brake Circuit with Piezoelectric-hydraulic Pump Using Pressurization/Depressurization Characteristics (압전유압펌프가 적용된 브레이크 회로의 가감압 특성을 이용한 압력 제어)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Bae, Jae-Sung;Kwon, Jun-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.8-15
    • /
    • 2017
  • In this paper, an equivalent brake hydraulic circuit with a piezoelectric hydraulic pump was constructed, and load pressure control for better pressurization/depressurization characteristics was conducted. To understand pressurization/depressurization characteristics of the equivalent hydraulic circuit, the relation between the load pressure and the input voltage was revealed experimentally. Experiments were also conducted to observe effect of the solenoid valve on depressurization characteristics. In the pressurization experiment, it was validated that transient response time required to achieve desired load pressure may be reduced through voltage control to change pressurization gradient. By applying the valve on/off time control and voltage control, it was also possible to reduce response time in the depressurization process. Therefore, transient response time may be improved within 10ms for pressurization and within 30 ms for depressurization using the control technique suggested in this study. The load pressure control method proposed in this study is useful for controlling load pressure of a hydraulic brake system with the piezoelectric hydraulic pump.

Wastewater Reuse in Textile Industry: Case of Bandung, Indonesia (섬유공장폐수 재이용 사례: 인도네시아 반둥을 대상으로)

  • Chung, Youngkun;Lee, Mi-Young;Yang, Shi Chun;Kang, Seoktae
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2019
  • Citarum river in West Java, Indonesia plays strategic roles for Jakarta metropolitan areas. Besides it provides major source of water supply such as domestics and drinking water including Jakarta, it also provides water for hundreds of industries through its cascade reservoirs. However, recently, Citarum river basin has been seriously suffering from water and groundwater pollution as well as the lowering-down of groundwater level due to the extreme use of water resources in dry season by domestic and industrial activities. This project objectives are design and installation of industrial wastewater treatment/recycle facilities to overcome the problem of water pollution and the lowering-down of groundwater level in Bandung. For these, cyclone type dissolved air flotation (DAF), CYFLOAT, was successfully installed as the appropriate technology for the target textile industry with 100 ton/day of capacity. The CYFLOAT system can remove the 96.8% of particulates, which are known as a critical factor to recycle the wastewater, within 40 min of residence time. Furthermore, The CYFLOAT system can reduce the operational cost and land use. The project was carried out in strong partnership with local institute including UNPAR, IBT, and PUSKIM for the sustainability of the technology to textile industry complex in Indonesia.

Fire Suppression Tests for a Train Using Water Mist Systems (미분무 소화시스템을 이용한 철도차량 실물화재 진압실험)

  • Choi, Byung-Il;Han, Yong-Shik;Do, Kyu-Hyung;Kim, Myung-Bae;Lee, Dong-Chan
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.57-65
    • /
    • 2009
  • Fire suppression tests are carried out for a train car using water mist systems. Three kinds of fire scenario applied to the real-scale train car are a surface fire representing car combustibles, a oil pool fire pretending an oil spill and a blocked fire for evaluation of space-cooling capacity. Five fixedpressure water mist systems and one self-contained water mist system with nitrogen gas are used for fire suppression experiments. Almost water mist systems can extinguish effectively train car fires, and fire-control capability of the system is seen due to the space cooling.

Influence of the Fire on Emergency Evacuation Support System (대공간용 비상피난지원 시스템에 화재가 미치는 영향 분석)

  • Kim, JiTae;Sung, Kun Hyuk;Park, Won Hee;Lee, Duck Hee;Woo, Jun You;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.626-631
    • /
    • 2018
  • An emergency evacuation support system is used to maintain evacuation routes by pressurizing a space inside screens. In cases of fire, it is important to understand the thermal distributions in the tunnel for preventing system failure. In this study, we numerically investigated the effect of fire on an emergency evacuation support system in a large fabric store with some fire scenarios with different combustibles. The critical temperature for system failures was assumed to be $200^{\circ}C$. As a result, the highest temperature was predicted in the ceiling part due to the effect of a ceiling jet, and the fire safety of the screen was secured at distances of 20 to 30 m according to the heat release rate. To prevent the inflow of smoke into the system, it is necessary to maintain more than 5 Pa if positive pressure inside the smoke screen. The results of this study could be useful for designing an emergency evacuation support system.

시스템 개발 프로세스 관리 능력의 향상을 위한 방안: 지식관리적 접근방법

  • 김성근;이진실;원은희
    • Proceedings of the Korea Database Society Conference
    • /
    • 1998.09a
    • /
    • pp.509-524
    • /
    • 1998
  • 정보시스템 개발노력의 상당수는 실패로 끝나고 있다. 최근 통계에 따르면 정보시스템 개발 프로젝트의 반은 실패로 끝난다고 한다[kaplan, 1998]. 이와 같은 높은 실패율은 시스템 개발을 위한 노력을 체계적으로 투입하지 못하고 개발 프로젝트를 관리하기 위한 노력을 단위프로젝트 차원에서만 집중시키는데서 연유한다고 생각된다. 다시 말해 장기적인 관점에서 개발조직의 역량 향상이라는 보다 근본적인 목표를 간과하고 있는 것이다. 이러한 점에 착안하여 소프트웨어 엔지니어링 분야에서는 정보시스템 개발과 관련'한 개발 조직의 능력을 향상시키기 위한 다양한 접근방법이 제시되고 있다. 개발조직의 개발 프로세스 성숙도를 진단하기 위한 측정도구로 개발된 카네기멜론대학의 CMM(Capability Maturity Model)과 ISO 에서 정의한 표준인 SPICE (Software Process Improvement and Capability dEtermination) 모델이 그 대표적인 예에 속한다. 그러나 이와 같은 모델들은 개발조직의 프로세스 개선을 위한 방향과 요건은 제시하고 있지만, 이를 조직 내에서 구현하기 위한 구체적인 방법이나 수단은 제시해주지 못하고 있다. 따라서 이러한 접근방법 역시 소프트웨어 엔지니어링 역량 이나 개발경험이 일천한 우리 현실에서는 부분적인 성과 이상을 기대하기는 어려웠다. 본 연구에서는 이와 같은 문제점이 개발 프로젝트와 관련된 경험이나 지식을 효과적으로 추출하고, 획득하고, 체계화하고, 시스템화하여 조직 내에서 활용하려는 노력이 부족한기 때문이라고 본다. 이에 본 연구에서는 개발조직의 역량 향상을 위한 지식관리적 접근 방법의 세가지 유형을 제시하기로 한다.>$Ca^{2+}$ 는 뿌리에서, $Mg^{2+}$ 는 잎에서 많았으며, $PO_4$$^{-}$ 는 과실과 줄기에서 많았다. 배지간에 따른 차이는 나타나지 않았으며, $K^{+}$, $Ca^{2+}$$Mg^{2+}$ 는10:0에서, $PO_4$$^{-}$ 는 8:2에서 각각 많았다.해 제품을 판매하였으며, 기업 및 제품이미지 제고를 위한 고객에 대한 서비스도 강화하고 있었다. 통신기기업체내지 소프트웨어 산업으로의 진출이 가능할 수 있도록 상호진출을 허용할 필요가 있다고 본다. 이를 위해서 우리 나라 정부 역시 미국처럼 새로운 통신개혁법을 만들 필요가 있다. 새로운 통신개혁법의 핵심적인 사항으로서 첫째, 통신과 CATV간의 상호진입을 허용, 둘째, 통신사업자가 통신관련 기기산업에 참여할 수 있는 규제완화를 허용, 셋째, 유아단계에 있는 소프트웨어 및 컨테트산업을 육성하는데 산업육성책 수립 등을 적극적으로 추진하여야 할 것이다. 그리고 현재 국내 재벌기업들로 구성되어 있는 기반산업을 지원하는 기술개발 지원체제와 육성정책을 소프트웨어 및 컨텐트의 응용산업으로 개편할 필요성도 제시되며, 이를 위해 범부처 차원에서 소프트웨어 및 컨텐트 육성정책을 지원하는 종합적인 대책을 마련해야 한다고 본다.서, Li-K, Li-Na탄산염에 대하여 부 식거동을 검토한 결과, 가압하에서 내식성이 향상되는 것이 발견되었다. 이유로서는 가압하에서 용융탄산엽의 증가된 산화력으로 보다 치밀한 내식성 산화물 피막이 형성되기 때문으로 생각되고 있다. 또

  • PDF

Operation Characteristics of 500W Class Anode Support Planar SOFC Stack (500W급 연료극 지지체 평판형 SOFC 스택의 운전특성)

  • Lim Tak-Hyoung;Song Rak-Hyun;Shin Dong-Ryul;Yang Jung-Il;Jeong Hun;Vinke I.C.
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.44-49
    • /
    • 2006
  • 본 연구는 독일 율리히 연구소에서 도입된 면적 200mm*200mm의 연료극 지지체 평판형 SOFC 셀 및 금속 분리판 5장을 적층하여 500W급 SOFC 스택을 제작하고, 이러한 스택의 운전특성을 분석한 연구이다. 도입된 500W급 SOFC 스택은 가스터빈-연료전지 하이브리드 시스템어에 사용되는 5kW급 SOFC 스택의 예비실험을 위한 것으로서, 본 연구의 목적은 상압 운전특성을 바탕으로 외국에서 시도된 적이 없는 평판형 SOFC 스택의 가압 운전기술을 확보하는 것이다. 이러한 목적을 위해 본 연구에서는 상압형 500W급 SOFC 발전시스템에 대한 구성과 설계, 전반적인 운전 특성평가 (5셀 스택 운전, 연료 전환 $(H_2{\rightarrow}pre-reformed\;gas)$, 500 시간 연속운전 등)가 이뤄졌다.

  • PDF

다중계통의 점검 및 보수로 인한 역효과(Adverse Effects)를 고려한 점검방법별 시스템 이용불능도(Unavailability) 분석

  • 유영우;정창현;제무성;정대욱;류용호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.562-569
    • /
    • 1996
  • 원자력 발전소 기기들에 대한 점검주기와 점검방법은 기술지침서(Tech. Spec)의 점검요건(SR)에 명시되어 있는데 가압경수로(PWR) 원전의 경우 다중계통 기기 점검은 교번시험(Staggered Test) 방법으로 점검하도록 되어 있다. 그러나 그 동안의 원전 운전경험에 의하면 기기 점검 및 보수로 인하여 기기 마모. 발전소 정지. 운전원의 부담감, 방사선 피폭 등의 역효과(Adverse Effects)가 있는 것으로 알려져 있다. 본 연구에서는 다중계통(Multi-redundancy System)중 2/4 시스템에 대한 점검방법별 이용불능도(Unavailability)를 해석적 방법으로 구하고 점검 및 보수로 인한 기기 마모 역효과를 모델링하여 점검방법별로 적용하고 비교 분석하였다.

  • PDF