• Title/Summary/Keyword: 가압가스

Search Result 185, Processing Time 0.025 seconds

Performance Test and Calculation of Recirculation Line in Propellant Feeding System (기체공급계 재순환배관의 성능시험 및 계산)

  • Kwon, Oh-Sung;Cho, Nam-Kyung;Chung, Yong-Gahp;Han, Sang-Yeop;Kim, Young-Mog
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.2
    • /
    • pp.9-17
    • /
    • 2007
  • The performance test of recirculation line in propellant feeding system was carried out. Liquid oxygen was used as cryogenic propellant and helium was used as recirculation promotion gas. Tests were done in cases at atmospheric pressure and at pressure of 4 barg in the ullage space of propellant tank. Liquid oxygen recirculation flowrate with helium injection flowrate and temperature distribution along the line were measured. There was appropriate helium injection flowrate for gas-lift recirculation system. Test data were used to make calculation program by test data correlation method. In this paper the procedure of calculation was presented and the results were compared to test data.

영광 3/4호기 Midloop 운전중 RHR 기능 상실사고시 CATHARE2 코드를 이용한 열수력 현상 해석 및 증기발생기 열제거 능력 평가

  • 김원석;하귀석;정재준;장원표;유건중
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.525-530
    • /
    • 1995
  • 최적 열수력 전산 코드인 CATHARE2 Vl.3u 코드를 이용하여 영광 3/4호기 midloop 운전중 잔열제거(RHR) 기능 상실사고를 해석하였다. 본 연구의 주된 목적은 사고시 계통에서 발생하는 열수력 현상의 이해 향상 및 증기발생기 열제거 능력 평가에 있다. 사고 복구 절차 관점에서 노심 비등, 노출 시점 및 계통압력 등이 중요한 인자이다. 본 계산 수행시 사용한 가정은 다음과 같다. 가) 초기 계통 수위는 고온관 중간에 위치하며 그 윗 부분은 질소 가스로 차 있다. 나) 3/4 인치 크기의 방출 밸브가 원자로 용기 상부 및 가압기 상부에 각각 설치되어 있으며, RHR 흡입구에 수위지시계가 설치되어 있다. 다) 증기발생기의 이차측은 U-튜브가 잠기도록 물로 차있다. 라) 두 증기발생기의 대기 방출 밸브(ADV)는 항상 열려 있어 사고시 이차측 압력을 대기압으로 유지하기에 충분하다. 사고는 원자로 정지 2일 후 발생하였다고 가정한다. 이와 같은 조건하에서 사고시 주된 계통 열제거 수단은 증기발생기 U-튜브내의 응축 작용이며 이는 전체 열제거량의 94%로 나타났다. 노심 비등 시점온 사고후∼300초 이후이며, 계통압력은 10,800초 이후에 최고 압력인 0.25MPa에 도달한 후 그 값을 계속 유지하고 있다. RHR 배관에 연결된 수위지 시계를 통해 10,200초 이후부터 냉각수가 방출되었다. 2개의 방출밸브 및 수위지시계를 통하여 방출된 유량에 근거하여 원자로 용기 냉각재 수위가 고온관 바닦까지 낮아지는 시점을 계산하면 사고 약 6.4 시간 이후가 된다.

  • PDF

Development of an Irradiation Device for High Temperature Materials in HANARO (하나로에서의 고온재료 조사장치 개발)

  • Cho, Man Soon;Choo, Kee Nam
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.145-153
    • /
    • 2011
  • The irradiation tests of materials in HANARO have been performed usually at temperatures below $300^{\circ}C$ at which the RPV(Reactor Pressure Vessel) materials of the commercial reactors such as the light water reactor and CANDU are operated. As VHTR(Very High Temperature Reactor) and SFR(Sodium-cooled Fast Reactor) projects are being carried as a part of the present Gen-IV program in Korea, the requirements for irradiation of materials at temperatures higher than $500^{\circ}C$ are recently being gradually increased. To overcome the restriction in the use at high temperature of the existing Al thermal media, a new capsule with double thermal media composed of two kinds of materials such as Al-Ti and Al-graphite was designed and fabricated more advanced than the single thermal media capsule. At the irradiation test of the capsule, the temperature of the specimens successfully reached $700^{\circ}C$ and the integrity of Al, Ti and graphite material was maintained.

Filmwise Reflux Condensation Length and Flooding Phenomena in Vertical U-Tubes (수직U-자관 속에서의 액체막 역류 응축 길이와 Flooding현상)

  • Moon-Hyun Chun;Jee-Won Park
    • Nuclear Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.45-52
    • /
    • 1985
  • A two inverted U-tubes condenser was constructed from transparent materials to study the heat removal capability of steam generators under filmwise reflux condensation mode. Essentially, two sets of experiments were performed: (1) the first dealt with the reflux condensation length, and (2) the second dealt with the flooding points with and without the presence of a noncondensible gas in the steam flow, and the effect of the flooding time. In addition, experimental results are compared with the predictions of analytical models.

  • PDF

A Study on the Development of Unified Ball Valve and Polyethylene-Steel Pipe Via Virtual Manufacturing and Experimental Approach (가상생산 및 실험을 통한 폴리에틸렌관과 금속관 일체형 볼 밸브의 개발에 관한 연구)

  • Suh, Yeong-Sung;Yoo, Je-Hyuk;Ji, Min-Wuk;Song, Jeong-Hyun;Lee, Jae-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.47-54
    • /
    • 2010
  • In order to reduce the number of installation processes and the cost, a unified ball valve and polyethylene-steel pipe is proposed and tested. An integrated design approach is carried out such that a virtual manufacturing based on finite-element analysis is first performed in order to examine contact conditions under exaggerated temperature variations (${\Delta}T\;=\;60^{\circ}C$ and $-50^{\circ}C$ for summer and winter, respectively). From the final design configuration, it was predicted that the maximum contact pressures are 71 and 8.1 MPa for summer and winter, respectively, at relatively larger contact surface. Based on this observation, a prototype model is fabricated to go through an actual leakage test. The prototype pipe passed a hydrostatic strength test successfully, showing no leakage at even much higher (54 MPa) than the operational pressure (0.25 MPa).

A Study on Injection Nozzle and Internal Flow Velocity for Removing Air Bubbles inside the Sample Tanks during Hydraulic Rupture Test (수압파열시험 시 시료 탱크 내부 기포 제거를 위한 주입 노즐 및 내부 유속 연구)

  • Yeseung, Lee;Hyunseok, Yang;Woo-Chul, Jung;Dong Hoon, Lee;Man-Sik, Kong
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.9-15
    • /
    • 2022
  • In order to verify the durability of the high-pressure hydrogen tank in the operating pressure range, a hydraulic rupture test should be performed. However, if the bubbles generated by the initial injection process of water are attached to the inner wall of the tank and remain, a sudden pressure change of the bubbles during the rupture of the pressurized tank may cause shock and noise. Therefore, in this study, the flow velocity required to remove the bubbles remaining on the inner wall of the tank was predicted through simplified formulas, and the shape of the injection nozzle to maintain the flow velocity was determined based on the shape of the hydrogen tank for the hydrogen bus. In addition, a numerical model was developed to predict the change in flow velocity according to the inlet pressure, and an experiment was performed through a model tank to prove the validity of the prediction result. As a result of the experiment, the flow velocity near the tank wall was similar to the predicted value of the analysis model, and when the inlet pressure was 1.5 to 5.5 bar, the minimum size of the removable bubble was predicted to be about 2.2 to 4.6 mm.

Assembly and Test of the In-cryostat Helium Line for KSTAR (KSTAR 저온용기 내부의 헬륨라인 설치 및 검사)

  • Bang, E.N.;Park, H.T.;Lee, Y.J.;Park, Y.M.;Choi, C.H.;Bak, J.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • In-cryostat helium lines are under installation to transfer a cryogenic helium into cold components in KSTAR device. In KSTAR, three kinds of helium should be supplied into the cold components, which are supercritical helium Into superconduction(SC) magnet system, liquid helium into current lead system, and gas helium into thermal shields. Cryogenic helium lines consist of transfer lines outside the cryostat, in-cryostat helium lines, and electrical breaks. In-cryostat helium lines should be guaranteed of leak tightness for tong time operation at high internal helium pressure of 20 bar. We wrapped the helium line with multi-layer insulator(MLI) to reduce radiation heat and insulated the surface of the high potential part with prepreg tape. The electrical break was fabricated by brazing ceramic tube with stainless steel tube. To ensure the operation reliability at operation temperature, all the electrical break have been examined by the thermal cycle test at liquid nitrogen and by the hydraulic test at 30 bar. And additional surface insulation was prepared with prepreg tape to give structural safety. At present most of the in-cryostat helium lines have been installed and the final inspection test is progressing.

Influence of the Fire on Emergency Evacuation Support System (대공간용 비상피난지원 시스템에 화재가 미치는 영향 분석)

  • Kim, JiTae;Sung, Kun Hyuk;Park, Won Hee;Lee, Duck Hee;Woo, Jun You;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.626-631
    • /
    • 2018
  • An emergency evacuation support system is used to maintain evacuation routes by pressurizing a space inside screens. In cases of fire, it is important to understand the thermal distributions in the tunnel for preventing system failure. In this study, we numerically investigated the effect of fire on an emergency evacuation support system in a large fabric store with some fire scenarios with different combustibles. The critical temperature for system failures was assumed to be $200^{\circ}C$. As a result, the highest temperature was predicted in the ceiling part due to the effect of a ceiling jet, and the fire safety of the screen was secured at distances of 20 to 30 m according to the heat release rate. To prevent the inflow of smoke into the system, it is necessary to maintain more than 5 Pa if positive pressure inside the smoke screen. The results of this study could be useful for designing an emergency evacuation support system.

Fabrication of Silicon Carbide Candle Filter and Performance Evaluation at High Temperature and Pressure (탄화규소 캔들형 필터의 제조 및 고온고압 하에서의 성능평가)

  • Lee, Sang-Hun;Lee, Seung-Won;Lee, Kee-Sung;Han, In-Sub;Seo, Doo-Won;Park, Seok-Joo;Park, Young-Ok;Woo, Sang-Kuk
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.5
    • /
    • pp.503-510
    • /
    • 2002
  • Silicon carbide candle filters for the pressurized fluidized bed combustion system were fabricated by extrusion process. Carbon black was added to control the porosity. Inorganic additives such as clay and calcium carbonate were added to exhibit appropriate strength. Silicon carbide layer with a finer pore size (mean pore diameter ~$10{\mu}m$) was coated on the silicon carbide support layer (mean pore diameter ~$47{\mu}m$, porosity ∼40%). After that, the filter was sintered at 1400${\circ}C$ in air. We evaluated the filtration performances of the filter at 500${\circ}C$ and $5kgf/cm^2$ of pressure. As a result, high separation efficiency, >99.999% was measured. It is expected that silicon carbide candle filter can be successfully used for the pressurized fluidized bed combustion system.

Fuel Characteristics of Quercus variabilis bio-oil by Vaccum Distillation (감압증류에 의한 굴참나무 바이오오일의 연료 특성 변화)

  • Chea, Kwang-Seok;Jo, Tae-Su;Lee, Soo-Min;Lee, Hyung Won;Park, Young-Kwon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.75-82
    • /
    • 2016
  • The technology of fast pyrolysis is regarded as a promising route to convert lignocellulose biomass into bio-oil which can be upgraded to transportable fuels and high quality chemical products. Despite these promises, commercialization of bio-oil for fuels and chemicals production is limited due to its notoriously undesirable characteristics, such as high and changing viscosity, high water and oxygen contents, low heating value and high acidity. Therefore, in this study quality improvement of bio-oil through vaccum distillation had been targeted. A 600 g of cork oak(Quercus variabilis) which grounded 0.8~1.4 mm was processed into bio-oil via fast pyrolysis for 1.64 seconds at $465^{\circ}C$ and temperature of vaccum distillation(100hPa) was designed to control, $40^{\circ}C$, 50, 60, 70, and 80 for 30min. Bio-oil, biochar, and gas of pyrolytic product were produced to 62.6, 18.0 and 19.3 wt%, respectively. The water content, viscosity, HHV(Higher Heating Value) and pH of bio-oil were measured to 0.9~26.1 wt%, 4.2~11.0 cSt 3,893~5,230 kcal/kg and 2.6~3.0, respectively. Despite these quality improvement, production was still limited due to its notoriously undesirable characteristics, therefore continous quality improvement will be needed in order to use practical fuel of bio-oil.