• Title/Summary/Keyword: 가스 폭발

Search Result 653, Processing Time 0.027 seconds

Analysis of A Gas Explosion-Related State Compensation Case (가스폭발 사고와 관련된 국가배상 사례의 분석)

  • Lee, Euipyeong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.44-59
    • /
    • 2020
  • This study analyzed a gas explosion accident. A gas smell from a underground coffee shop in the two-story building was reported to 119. A fire brigade was turned out, turned off the main valve of LPG gas cylinder on the roof, and checked the turning off of middle valve in the coffee shop. The fire brigade required a gas supplier and gas installer who arrived at the spot to take safety actions. Gas explosion occurred seven minutes after the fire brigade was withdrawn and two people died and 21 people were injured. A court decided that because the causes for gas explosion were not found, compensation responsibility could not be charged with the gas supplier, the gas installer, or Korea Gas Safety Corporation. In this reason, the court judged that only the fire brigade who was withdrawn without taking safety actions shall compensate victims or bereaved families. Therefore, fire brigades who turn out after a 119 report of a gas leak should take safety actions such as escaping people or preventing people's access and ventilating and be withdrawn when there is no possibility of fire or explosion.

Quantitative Risk Assessment for Gas-explosion at Buried Common Utility Tunnel (지하 매설 공동구 내부 가스 폭발에 대한 위험성 평가)

  • Jang, Yuri;Jung, Seungho
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.89-95
    • /
    • 2016
  • Keeping the gas pipelines in the common utility tunnel is useful because it has a lower risk of corrosion than conventional burial, and can prevent from excavating construction. But, explosions in common utility tunnels can cause greater damage from the blast overpressure compared to outdoor explosions, due to nature of the confined environment. Despite this fact, however, research on common utility tunnels has been limited to fire hazard and little has been studied on the dangers of explosions. This study developed scenarios of methane gas explosion caused by gas leak from gas piping within the common utility tunnel followed by unknown ignition; the study then calculated the extent of the impact of the explosion on the facilities above, and suggested the needs for designing additional safety measures. Two scenarios were selected per operating condition of safety devices and the consequence analysis was carried out with FLACS, one of the CFD tools for explosion simulation. The overpressures for all scenarios are substantial enough to completely destroy most of the buildings. In addition, we have provided additional measures to secure safety especially reducing incident frequency.

A Study on the Explosion Hazard by Spark Discharge of the Lithium-Ion Battery (리튬이온전지의 불꽃방전에 의한 폭발위험성에 관한 연구)

  • Lee, Chun-Ha;Jee, Seung-Wook;Kim, Shi-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.14-20
    • /
    • 2010
  • This paper was studied on the explosion hazard by spark discharge of the lithium-ion battery. The experimental samples were chosen lithium-ion battery(general, notebook) which were used for source of portable equipment. The IEC(International Electrotechnical Commission) type spark ignition test apparatus and experimental gases such as methane, propane, ethylene or hydrogen were used for explosiveness test. It was confirmed through the experiment that the explosion hazard by spark discharge. Also, it was used thermal imager for confirm that spontaneous ignition possibility by short-circuit. As the result, this paper verified that lithium-ion battery should be used and designed by special attention safety in the hazardous zone which is existed explosiveness gas.

Experimental Study on Gas Explosion According to the Effect of Confinement and Congestion Levels (밀폐도 및 밀집도의 영향에 따른 가스폭발 실험 연구)

  • Boohyoung Bang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.56-61
    • /
    • 2023
  • The plant is an important facility as a infrastructure, and ensuring safety against possible accidents such as gas leaks and explosions must be considered in the design. However, there is little study on explosion pressure in plants for reasons such as economic feasibility, and overpressure data on this field is insufficient. In this study, an experimental design plan considering the explosion scenario that may occur in the plant was presented, and the explosion pressure was confirmed through an explosion experiment. Hydrogen-methane mixed gas was used as a combustible material, and the effect of confinement and congestion on overpressure was studied. The effect of overlapping pressure waves during deflagration and the turbulence effect by congested pipes are discussed. The results of this study can be used as input data in various safety designs.

사고사례 분석을 통한 LPG자동차 충전소의 위험요인 도출

  • 김대수;김홍영;윤재건
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.05a
    • /
    • pp.139-144
    • /
    • 1997
  • 지난 30년간의 LPG(Liquified Petroleum Gas)자동차의 사용으로 현재 전국에는 500여 곳의 LPG자동차 충전소가 운영되고 있다. LPG자동차의 운행대수에 비하면 충전소의 수가 절대적으로 부족하고, 또한 LPG자동차의 보급확대를 위해서는 충전소 확충이 필수적이다. 그러나 최근의 아현동 도시가스 밸브기지 폭발사고나 대구 지하철 공사장 도시가스 폭발사고와 같은 대형 가스 폭발사고의 여파로 충전소 설치 부지의 확보에 큰 어려움을 겪고 있다. 특히, 대도시 지역 내에서의 충전소 설치는 인근 지역주민의 강력한 반대로 거의 불가능한 실정이다. (중략)

  • PDF

Hazard Analysis of the LPG Tank Lorry (LPG 탱크로리 위험분석)

  • 장우정;윤재건
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.53-58
    • /
    • 1998
  • 지난 30년간의 LPG(Liquified Petroleun Gas)자동차의 사용으로 현재 전국에는 600여 곳의 LPG자동차 충전소가 운영되고 있다. LPG자동차의 운행대수에 비하면 충전소의 수가 절대적으로 부족하고, 또한 LPG자동차의 보급확대를 위해서는 충전소 확충이 절대적으로 필수적이다. 그러나 최근의 부천의 가스충전소 폭발사고, 아현동 도시가스 밸브기지 폭발사고와 같은 대형가스 폭발사고의 여파로 충전소 설치 부지확보에 큰 어려움을 격고있다. (중략)

  • PDF

A study on numerical analysis of the accidental gas explosion (수치해석에 의한 가스폭발사고 분석)

  • ;V.M.Poutchcov
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.05a
    • /
    • pp.145-152
    • /
    • 1998
  • 실내에서 가스폭발시 피해를 예측하기 위해서 폭발 화염면의 전파를 수치해석을 통해 해석했다. 확산방정식에 의해 가스누출에 의한 실내의 가스확산분포를 구했으며 문헌에서 선택한 누출의 초기조건을 사용했다. 화염온도를 계산하기 위해 각 가스 혼합비에 따른 엔탈피와 화학식에 대한 reduced mechanism을 사용했으며 문헌에서 찾은 각 가스의 농도별 층류 연소속도를 혼합가스의 층류연소속도에 적용시켰다. k-$\varepsilon$ 모델에서 turbulance energy를 층류연소속도와 결합시켜 난류화염 전파속도를 모델링 했다. 화염면의 전파를 분석하기 위해 실내의 위치에는 직각, 화염면의 전파에는 원통좌표계를 사용했다. 유리창의 파손에 의한 화염전파면의 변화에 따른 압력상승 요인을 해석하였으며 창문의 크기에 따라서 점화위치에 따른 실내 압력상승의 영향이 서로 다르게 나타나는 결과를 얻었다.

  • PDF

LPG방출 실험

  • 이창수;이장우;박찬옥;김선혁;임지환
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.05a
    • /
    • pp.45-50
    • /
    • 1997
  • 가스사고 중 단순 누설, 누설에 의한 폭발 및 화재사고가 ‘77년부터 ‘95년까지 전체사고의 97,2%를 차지하고 있고, ‘95년 한해동안에는 90%를 초과하여 발생하였으나, 사고의 원인은 명백하게 규명하면서도 폭발 또는 화재발생에 따른 가스의 누출량을 입증하기 위한 자료나 실험자료가 없어 사고조사에 곤란을 격고 있었으며, 이에 따라 가스의 누출량을 추정할 때 조정기의 용량이나 일반적인 누출량 계산식에 근거하여 가스의 누출량을 추산하여 폭발 및 화재발생의 원인을 추정하고 있는 등 사고발생과정을 설명하는데 미진한 부분이 많아 실제로 LPG의 누출량을 측정하여 그 기록을 사고조사시 활용하고 사고 발생과정을 과학적으로 입증하는데 다소 보탬이 되도록 하기 위하여 이번 실험을 실시하게 되었고 본 실험의 통계적인 수치를 전적으로 실제 사고에 적용하기란 아직까지 미흡한 점이 많다고 생각되나 정확한 사고원인조사가 가스안전관리 정책수립의 기본 바탕이 되어야 함으로 이러한 실험이 계속 발전적으로 실시되어 자료로 활용될 수 있기를 바라며, 다소 아쉽고 미흡한 점도 많은 실험이었으나 가스의 누출량에 대한 첫 실험이었다는 점에 의의를 두고, 앞으로 이와 같은 실험이 지속되어 가스안전에 관한 시험 및 자료수집이 활발해 질수 있기를 바란다. (중략)

  • PDF

A study on the Response Timing for an Installation Location of Gas Sensors using Computational Analysis (전산해석을 이용한 가스센서 설치위치에 따른 응답시간에 관한 연구)

  • Kim, Hyun-Il;Kim, Young-Doo;Park, Gyou-Tae;Han, Sang-In;Kwon, Jeong-Rock
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.382-383
    • /
    • 2008
  • 현재 가정이나 산업용으로 사용하는 가스 화기나 보일러 등에서 가스 누출에 의한 화재사고나 폭발사고가 빈번하게 발생하고 있다. 가스 누출에 의한 사고는 오랜 시간 가스 누출 후 점화원에 의한 폭발이나 화재사고가 대다수를 차지한다. 일반적으로 천연가스를 사용하는 경우 상단부에 가스누출검지기를 설치하고 있다. 하지만 이러한 설치 위치는 대략적인 가스의 특성을 고려한 것이다. 본 연구에서는 가스 누출이 발생할 수 있는 누출위치를 가정의 가스레인지 화구와 밸브 연결부로 선정하고, 전산유체역학(CFD)을 이용하여 가스누출검지기의 시간에 따른 응답특성을 파악하여, 빠른 가스 검지를 위해 가스누출검지기 설치 위치를 최적화하였다. 본 연구의 결과를 기초로 가정이나 건물의 가스누출검지기출 설치할 경우, 가스가 누출되었을 때 신속한 검지를 통하여 위험을 알림으로서 가스폭발이나 사고를 미연에 방지할 수 있을 것이다.

  • PDF

Performance Evaluation of Weir Structures Under Blast Loads (폭발하중에 의한 다기능-수중보 구조물 거동평가)

  • Jeon, Jun-Tai;Jung, Woo-Young;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.168-169
    • /
    • 2015
  • 최근 위험물질에 의한 폭발 및 테러의 위험성 증가로 인하여 사회간접자본 시설물인 댐/보, 원자력 발전소, 병원 구조물과 같은 주요 시설물의 폭발 안전성 평가 연구가 이슈화 되고 있어, 본 연구에서는 가스폭발에 의한 다기능 보 구조물의 거동을 평가하고 안전성을 분석 하고 자 한다. 본 연구에서 폭발 해석에 필요한 하중 조건 산정은 PHAST 프로그램을 사용하여 주변 온도 및 공기 특성 등을 고려한 약 5톤의 가스 폭발 조건을 구축 하였다. 또한 다기능 보 구조물의 거동 분석을 위해 구조물-지반 상호 작용을 고려한 2차원 유한 요소 모델을 구축하여 폭발에 의한 구조물 거동을 평가 하였다. 다기능 보 구조물의 수치해석 결과 보 구체와 Stilling Basin구조물 사이의 연결부에 응력집중 현상이 발생하는 것으로 평가 되었다.

  • PDF