• Title/Summary/Keyword: 가스루프

Search Result 49, Processing Time 0.03 seconds

Experimental Study on Combustion Instability in a Dump Combustor (덤프 연소기에서의 연소불안정에 대한 실험적 연구)

  • An, Gyu-Bok;Yun, Yeong-Bin;Yu, Kenneth
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.12
    • /
    • pp.35-40
    • /
    • 2006
  • The combustion instability in a model dump combustor with an exhaust nozzle and the possibility of combustion control using a loudspeaker to these instabilities were studied. By changing inlet velocity, combustor length and equivalence ratio, dynamic pressure signals and flame structures were simultaneously taken. Because inlet velocity and combustor length affect the life time of vortex in the dump combustor, the results showed that as the combustor length increased and the inlet velocity decreased, the instability frequency decreased and the maximum power spectral density of the dynamic pressure generally decreased. Also, instability frequency and maximum power spectral density of the dynamic pressure increased with the increment of equivalence ratio. From the data of close-loop control, the optimum time-delay control using a loudspeaker was confirmed to be able to reduce the vortex shedding induced from the mixed acoustic-convective mode combustion instability.

고리 1호기 계속운전 추진 현황

  • Jeong, Seong-Du
    • Nuclear industry
    • /
    • v.27 no.4 s.290
    • /
    • pp.46-50
    • /
    • 2007
  • 고리 1호기는 한국에서 최초로 규제 기관에 계속운전을 신청한 원전이다. 2007년 6월에 설계 수명 기간 만료가 되는 고리 1호기는 규제 기관으로부터 계속운전(Continued Operation)에 대한 안전성 심사를 받고 있다. 한수원은 고리 1호기 계속운전 승인을 금년 12월에 받기 위해 최선을 다하고 있으며 지역 주민의 사회적 수용성 확보를 위해 노력중이다. 고리 1호기의 계속운전 기간 동안 안전성을 평가하고 정리한 안전성평가보고서를 한수원은 2006년 6월에 정부에 제출하였다. 고리 1호기는 웨스팅하우스의 2루프 가압경수로이다. 이와 동일한 원전인 일본의 미하마 1,2호기와 겐까이1호기가 계속운전중이며, 미국의 기네이와 포인트 비치 1,2호기가 계속운전 승인을 받았다. 제출한 안전성평가보고서에 대해 한국원자력안전기술원이 심사중이며, 해외 원전과 같이 계속운전을 할 수 있을 것으로 예상하고 있다. 또한 계속운전을 위한 사회적 수용성(Public Acceptance) 확보는 설비의 철저한 안전성 확보 및 지역 주민의 공감대 형성을 통해서 이루어질 것이다. 설계 수명 이후 원자력발전소를 계속 운전하는 것은 이미 선진국에서 시행되고 있다. 2007년 3월 기준으로 미국에서 48기가 운영 허가 갱신 승인을 받았고, 영국은 8기, 일본은 12기가 계속운전중이다. 고리 1호기 성능 지표를 개선시키기 위해서 한수원은 증기발생기, 저압 터빈, 원자로 냉각재 펌프 내장품, 주변압기, 주발전기 등을 교체하였으며, 수명관리 연구, 주기적안전성 평가, 환경 영향 평가를 수행하였다. 2005년 9월에는 미국의 운영 허가 갱신 제도를 참조하여 원자력법이 개정되었다. 이에 한수원은 개정된 원자력법에 맞추어 주기적 안전성평가, 주요 기기에 대한 수명 평가 및 방사능 환경 영향평가를 하였다. 이 세가지 보고서들로 구성된 안전성평가보고서를 2006년 6월에 규제 기관에 제출하였다. 계속운전은 한국을 비롯하여 부존 자원이 부족한 국가들에게는 에너지 자원의 효율적 활용 및 온실 가스 배출을 고려할 때 반드시 필요한 것이다.

  • PDF

A Study on the Thermal-Hydraulic Characteristics of Molten Salt in Minichannels of an Intermediate Heat Exchanger for a Very High Temperature Reactor (VHTR) (초고온원자로 중간열교환기 미니챈널에서의 Molten Salt 열수력 특성 연구)

  • Jeong, Hui-Seong;Hwang, In-Seon;Bang, Kwang-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1093-1099
    • /
    • 2010
  • For Very High Temperature Reactors (VHTR), the designs of the Intermediate Heat Transport Loop (IHTL) and the Intermediate Heat Exchanger (IHX) are particularly difficult because of the high-temperature operation (up to $950^{\circ}C$). In this study, Flinak molten salt, a eutectic mixture of LiF, NaF, and KF (46.5:11.5:42.0 mole %) is considered as the heat transporting fluid in the IHTL. To evaluate the flow and heat transfer performance of the Flinak molten salt in small channels with hydraulic diameters in the millimeter range, a double-pipe heat exchanger was constructed using small-diameter tubes for the heat exchange between the Flinak and the gas flow. The experimental data showed that, for laminar Flinak flow, the measured friction factors were close to the 64/Re curve and the Nusselt numbers were generally between 3.66 and 4.36.

An Experimental Study of Green Roofs on Indoor Temperature Reduction (옥상녹화의 건물 내 온도 저감 효과에 대한 실험적 연구)

  • Kang, Da Won;Choi, Hui Dong;Seo, Yong Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.157-157
    • /
    • 2021
  • 2015년 파리에서 체결된 파리협정은 1850년 대비 2100년까지의 지구 평균기온 상승을 1.5℃ 이내로 제한하기 위해 5년마다 참여국에 상향된 온실가스 배출 감축 목표를 제출하게 하고, 탄소 배출 및 온도상승 저감 목표 달성을 위해 도시 내 그린인프라를 적극적으로 도입하는 등 국제사회 공동의 종합적인 이행을 예정하고 있다. 그린인프라의 유형 중 하나인 옥상녹화(Green Roof)는 기후변화 적응을 위한 도시 인프라 구축 방법의 하나로 국내에서도 많은 각광을 받고 있다. 옥상녹화(Green Roof)는 도시의 불투수층인 지붕 면적을 모두 혹은 일부 식생으로 덮어 표면층에 추가의 투수층을 조성하는 것을 지칭한다. 옥상녹화의 경우 별도의 토지면적 확보가 필요하지 않고 기존의 시설물에 추가적인 설치가 가능해 여분의 토지가 부족한 도심지의 녹지 확보를 위한 친환경적인 그린인프라로 각광받고 있다. 현재까지 옥상녹화(Green Roof) 관련 국내 연구 현황은 '옥상 녹화의 공법'을 다룬 비율이 높고 실증적인 결과를 가진 선행연구가 거의 없다. 따라서 본 연구는 동일한 조건하에 4개의 실험동을 설치하고 동질성 검사를 한 후 옥상에 설치된 재료[일반 콘크리트(Bare Concrete), 고반사 도장(High Reflective Paint), 사사(Short Bamboo), 잔디(Grass)]에 따른 건물 내 온도 변화 저감효과에 대한 분석을 수행하였다. 2020년 8월 17일부터 22일까지 측정된 지붕 표면 평균 최고온도 모니터링 결과를 일반 콘크리트 지붕과 비교했을 때. 고반사 도장 지붕의 경우 8.26℃, 옥상녹화(사사, short bamboo) 지붕의 경우 7.21℃, 옥상녹화(잔디, grass)의 경우 10.8℃ 낮은 것으로 측정되었다. 또한 실내 천정 표면 평균 온도의 경우 콘크리트 지붕과 비교하여 고반사 도장 지붕은 6.46℃, 옥상녹화(사사, short bamboo) 지붕은 13.52℃, 옥상녹화(잔디, grass)는 13.3℃ 낮은 것으로 나타났다. 본 연구결과는 옥상녹화의 온도저감 효과를 정량적으로 제시하고 있어, 향후 기후변화 대응 및 적응 전략적 수립에 기여할 수 있을 것으로 판단된다.

  • PDF

Design and Evaluation of Small-scale Supercritical Carbon Dioxide System with Solar Heat Source (태양열 적용을 위한 소형 초임계 이산화탄소 실험설비 설계 및 평가)

  • Choi, Hundong;So, Wonho;Lee, Jeongmin;Cho, Kyungchan;Lee, Kwon-yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.403-410
    • /
    • 2020
  • This paper focuses on the design of a 12-kW small-scale supercritical CO2 test loop. A theoretical study, stabilization, and optimization of carbon dioxide were carried out with the application of a solar heat source based on solar thermal data in Pohang. The thermodynamic cycle of the test facility is a Rankine cycle (transcritical cycle), which contains liquid, gas, and supercritical CO2. The system is designed to achieve 6.98% efficiency at a maximum pressure of 12 MPa and a maximum temperature of 70℃. In addition, the optimum turbine inlet temperature and pressure were calculated to increase the cycle efficiency, and the application of an internal heat exchanger (IHX) was simulated. It was found that the maximum efficiency increases to 18.75%. The simulation confirmed that the efficiency of the cycle is 6.7% in May and 6.26% in June.

Implementation of Fuzzy Controller for MFC (MFC의 퍼지제어기 구현)

  • Lee, Seok-Ki;Lee, Yun-Jung;Lee, Seung-Ha
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.5
    • /
    • pp.648-654
    • /
    • 2004
  • The Mass Flow Controller(MFC) has become crucial in semiconductor manufacturing equipments. It is an important element because the quality and the yield of a semiconductor process are decided by the accurate flow control of gas. Therefore, the demand for implementing the high speed and the highly accurate control of MFCs has been increasing. It is hard to find an article of the control algorithm applied to MFCs. But, it is known that commercially available MFCs adopt PID control algorithms. Particularly, when the system detects the flow by way of heat transfer, the MFC control problem includes the slow response and the nonlinearity. In this paper, MFC control algorithm with a superior performance to the conventional PID algorithm is discussed and the superiority is demonstrated through the experiment. A fuzzy controller was utilized in order to compensate the nonlinearity and the slow response, and the performance is compared with that of an MFC currently available in the market. The control system, in this paper, consists of a personal computer, the data acquisition board and the control algorithm carried out by LabWindows/CVI program on the PC. In addition, a method of estimating the actual flow from the sensor output with the slow response is presented. In conclusion, according to the result of the experiment, the proposed algorithm shows better accuracy and is faster than the conventional controller.

Radiosynthesis of $[^{11}C]6-OH-BTA-1$ in Different Media and Confirmation of Reaction By-products. ($[^{11}C]6-OH-BTA-1$ 조제 시 생성되는 부산물 규명과 반응용매에 따른 표지 효율 비교)

  • Lee, Hak-Jeong;Jeong, Jae-Min;Lee, Yun-Sang;Kim, Hyung-Woo;Lee, Eun-Kyoung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.241-246
    • /
    • 2007
  • Purpose: $[^{11}C]6-OH-BTA-1$ ([N-methyl-$^{11}C$]2-(4'-methylaminophenyl)-6-hydroxybenzothiazole, 1), a -amyloid imaging agent for the diagnosis of Alzheimer's disease in PET, can be labeled with higher yield by a simple loop method. During the synthesis of $[^{11}C]1$, we found the formation of by-products in various solvents, e.g., methylethylketone (MEK), cyclohexanone (CHO), diethylketone (DEK), and dimethylformamide (DMF). Materials and Methods: In Automated radiosynthesis module, 1 mg of 4-aminophenyl-6-hydroxybenzothiazole (4) in 100 l of each solvent was reacted with $[^{11}C]methyl$ triflate in HPLC loop at room temperature (RT). The reaction mixture was separated by semi-preparative HPLC. Aliquots eluted at 14.4, 16.3 and 17.6 min were collected and analyzed by analytical HPLC and LC/MS spectrometer. Results: The labeling efficiencies of $[^{11}C]1$ were $86.0{\pm}5.5%$, $59.7{\pm}2.4%$, $29.9{\pm}1.8%$, and $7.6{\pm}0.5%$ in MEK, CHO, DEK and DMF, respectively. The LC/MS spectra of three products eluted at 14.4, 16.3 and 17.6 mins showed m/z peaks at 257.3 (M+1), 257.3 (M+1) and 271.3 (M+1), respectively, indicating their structures as 1, 2-(4'-aminophenyl)-6-methoxybenzothiazole (2) and by-product (3), respectively. Ratios of labeling efficiencies for the three products $([^{11}C]1:[^{11}C]2:[^{11}C]3)$ were $86.0{\pm}5.5%:5.0{\pm}3.4%:1.5{\pm}1.3%$ in MEK, $59.7{\pm}2.4%:4.7{\pm}3.2%:1.3{\pm}0.5%$ in CHO, $9.9{\pm}1.8%:2.0{\pm}0.7%:0.3{\pm}0.1%$ in DEK and $7.6{\pm}0.5%:0.0%:0.0%$ in DMF, respectively. Conclusion: The labeling efficiency of $[^{11}C]1$ was the highest when MEK was used as a reaction solvent. As results of mass spectrometry, 1 and 2 were conformed. 3 was presumed.

Study on Sludge Reduction by Sludge Solubilization and Change of Operation Conditions of Sewage Treatment Process (하수슬러지 가용화와 하수처리 운전조건 개선을 통한 하수슬러지 발생저감 연구)

  • Choi, In-Su;Jung, Hoe-Suk;Han, Ihn-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1113-1122
    • /
    • 2009
  • In order to find the way to solve the problem of sewage sludge discharge into the ocean, the sludge solubilization by ultrasonic and the improvement methods of wastewater treatment process were studied. In the membrane bioreactor the sludge retention time was stepwise increased from 5.1 day to 442 days where the biomass average concentration has been increased from $c_B$=3.4 $gTSSL^{-1}$ to $c_B$=14.5 $gTSSL^{-1}$ respectively. At the same time, the biomass yield coefficients were reduced from 0.5-0.7 at SRT=5.1 day to 0.005-0.007 at SRT=442 days which means the reduction of sludge production. Oxygen mass transfer coefficients and ${\alpha}$-factor were investigated with changing stirrer speed to find the relation between the high biomass concentration and aeration efficiency in the propeller loop reactor. As a result of sludge solubilization, the solubilization of sludge by ultrasound was increased with increasing energy input and it led to improved anaerobic digestion rate with more biogas production than that of nonsolubilized sewage sludge.

Process Suggestion and HAZOP Analysis for CQ4 and Q2O in Nuclear Fusion Exhaust Gas (핵융합 배가스 중 CQ4와 Q2O 처리공정 제안 및 HAZOP 분석)

  • Jung, Woo-Chan;Jung, Pil-Kap;Kim, Joung-Won;Moon, Hung-Man;Chang, Min-Ho;Yun, Sei-Hun;Woo, In-Sung
    • Korean Chemical Engineering Research
    • /
    • v.56 no.2
    • /
    • pp.169-175
    • /
    • 2018
  • This study deals with a process for the recovery of hydrogen isotopes from methane ($CQ_4$) and water ($Q_2O$) containing tritium in the nuclear fusion exhaust gas (Q is Hydrogen, Deuterium, Tritium). Steam Methane Reforming and Water Gas Shift reactions are used to convert $CQ_4$ and $Q_2O$ to $Q_2$ and the produced $Q_2$ is recovered by the subsequent Pd membrane. In this study, one circulation loop consisting of catalytic reactor, Pd membrane, and circulation pump was applied to recover H components from $CH_4$ and $H_2O$, one of $CQ_4$ and $Q_2O$. The conversion of $CH_4$ and $H_2O$ was measured by varying the catalytic reaction temperature and the circulating flow rate. $CH_4$ conversion was 99% or more at the catalytic reaction temperature of $650^{\circ}C$ and the circulating flow rate of 2.0 L/min. $H_2O$ conversion was 96% or more at the catalytic reaction temperature of $375^{\circ}C$ and the circulating flow rate of 1.8 L/min. In addition, the amount of $CQ_4$ generated by Korean Demonstration Fusion Power Plant (K-DEMO) in the future was predicted. Then, the treatment process for the $CQ_4$ was proposed and HAZOP (hazard and operability) analysis was conducted to identify the risk factors and operation problems of the process.