• Title/Summary/Keyword: 가스기기

Search Result 453, Processing Time 0.024 seconds

High-Temperature Structural Analysis of a Small-Scale PHE Prototype - Analysis Considering Material Properties in Weld Zone - (소형 공정열교환기 시제품 고온구조해석 - 용접부 물성치를 고려한 해석 -)

  • Song, Kee-Nam;Hong, Sung-Deok;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1289-1295
    • /
    • 2012
  • A process heat exchanger (PHE) in a nuclear hydrogen system is a key component for transferring the considerable heat generated in a very high temperature reactor (VHTR) to a chemical reaction that yields a large quantity of hydrogen. A performance test on a small-scale PHE prototype made of Hastelloy-X is underway in a small-scale gas loop at the Korea Atomic Energy Research Institute. Previous research on the high-temperature structural analysis of the small-scale PHE prototype had been performed using base material properties. In this study, a high-temperature structural analysis considering the mechanical properties in the weld zone was performed, and the obtained results were compared with those of the previous research.

Development of a New Analytical Instrument with Glow Discharge System and Studies on the Direct Solid Analysis Method (글로우방전을 이용한 새로운 정밀분석기기의 개발 및 금속시료의 직접분석법에 관한 연구)

  • Jeoung Hwa Park;Hyo Jin Kim;Jin Chun Woo;Chang Joon Park;Dae Won Moon;Kwang Woo Lee
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.2
    • /
    • pp.273-281
    • /
    • 1992
  • A new sputtering chamber, as Atomsource, for atomic absorption measurements was designed and built to have maximum ground state atoms in view and minimum emission. The high velocity gas jets not only change the visual and electrical characteristics of the discharge, but also increase the amount of material atomized, as is apparent from the craters that are produced in the sample where the jets strike the surface. The use of gas jets in a sputtering cell makes this a direct sampling method practical for atomic absorption spectrometry. The factors influencing absorption sensitivity and reproducibility have been investigated for the newly developed atomizer.

  • PDF

Macroscopic High-Temperature Structural Analysis of PHE Prototypes Considering Weld Material Properties (용접 물성치를 고려한 공정열교환기 시제품의 거시적 고온구조해석)

  • Song, Kee-Nam;Hong, Sung-Deok;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1095-1101
    • /
    • 2012
  • A process heat exchanger (PHE) in a nuclear hydrogen system is a key component that transfers the large amount of heat generated in a very high temperature reactor (VHTR) to a chemical reaction that yields a large quantity of hydrogen. A performance test on a small-scale and a medium-scale PHE prototype made of Hastelloy$^{(R)}$-X is being conducted on in a small-scale nitrogen gas loop at the Korea Atomic Energy Research Institute. Previous research on the macroscopic high-temperature structural analysis of PHE prototypes had been performed using base material properties owing to a lack of weld material properties. In this study, macroscopic high-temperature structural analyses considering the weld material properties were performed and the results were compared with those of a previous study.

Analysis of Safety and Performance Vulnerabilities Using Heat-Using Equipment(Industrial Boiler) Inspection Results (열사용기자재 검사대상기기(산업용 보일러) 검사결과를 활용한 안전 및 성능 취약점 분석)

  • Kim, Hyung-Jun;Oh, Choong-Hyeon
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.18-26
    • /
    • 2022
  • The Korean government is conducting heat-using equipment(industrial boiler) inspection in accordance with the Energy Use Rationalization Act because of the heat-using equipment(industrial boiler)'s risks such as explosion and fire, and safe use and management. This paper aimed to setup the safe and performance vulnerabilities from database based on the inspection results for heat-using equipment(industrial boiler). This study surveyed the inspection results of 1,249 heat-using equipment(industrial boiler) which were failed inspection of heat-using equipment(industrial boiler) from january 2016 to december 2020. And the analysis method is to inform safety and performance vulnerability categories of heat-using equipment(industrial boiler) by statistically analyzing the failure reasons of boiler type and inspection type which are high variance in failure rate. The safety and performance vulnerability categories was abbreviated into 18 cases. And each catagory's main reason for failure was suggested by additional analyzing the opinions of inspectors. This paper would be the basic source and the comprehensive information dealing with the safety and performance vulnerability of heat-using equipment(industrial boiler).

전자부품의 냉각을 위한 자연대류 상관 관계식의 평가

  • 이재헌
    • Journal of the KSME
    • /
    • v.27 no.6
    • /
    • pp.504-514
    • /
    • 1987
  • 복잡한 전자부품의 조립시에 필요한 열적 디자인에 관한 정보는 오래전부터 실험을 통하여 얻어지고 있다. 실험적 데이터를 이용하여 무차원 파라미터로 표시된 실험결과는 꼭 같지는 않지만 현상적으로는 비슷한 상황에 응용될 수 있다. 여기서는 학술문헌에 나타나 있는 자연대류에 관한 실험적인 상관관계식들과 프레임에 수직으로 꽂혀있는 균일가열 전자회로기판의 모델에서 얻어진 무차원 자료들을 비교하고자 한다. 대부분의 자료들은 수정채널 Rayleigh수(Ra")가 15~100범위에 속하며, 이러한 범위는 부품이 조밀하게 배치된 기관이 서로 좁은 채널을 이루고 있으며, 동시에 상당한 전력을 소비하고 있는 경우에 해당한다. Wirt와 Stutzman, Bar-Cohen과 Rohsenow의 일반상관관계식은 AT'||'&'||'T Bell 연구소에서 개발된 전자기기를 이용하여 수집한 실험데이터를 잘 표현하고 있으며 10 < Ra" <1,000범위에서 추천될 수 있다. 두개의 유사한 상관관계식과 비교할 때 상당히 좋은 예측을 보였으며 또한 Sparrow와 Gregg의 연구결과와도 잘 일치하므로 Ra" < 10인 경우에 Aung의 완전발달층류의 채널유동방식, Ra" > 1,000인 경우에는 Aung등의 단일 수직평판 근사식이 추천될 수 있다. Coyne의 알고리즘에 의한 계산치는 10

  • PDF

Simultaneous determination of aromatic material causing allergic in children's products by Gas Chromatography (어린이 제품 중 가스 크로마토그래피를 이용한 알러지 유발 방향성 물질의 동시분석법)

  • Ko, Kyeong Mok;Rhu, Chan Joo;Kim, Jong Won;Lee, Seok Ki
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.23-30
    • /
    • 2018
  • Twenty-two allergy-induced aromatics in children were analyzed using a gas chromatography flame ionization detector (GC-FID) and gas chromatography mass spectrometer (GC-MSD). Analytes were extracted using an automatic Soxhlet extractor and centrifuged for 10 min in a fast freezing centrifuge, and the supernatant was transferred into a 2 mL vial and injected in split mode. Under the established conditions, the calibration curve showed linearity with a correlation coefficient of 0.996 or more. A wide range of sensitivity of 6.7 to 1,859,839 depending on the device characteristics and detector used was shown. The detection limit of the device was 0.0032 to $0.0335{\mu}g/mL$, and the maximum detection limit was less than $0.1{\mu}g/mL$. The detection limit of the method ranged from 0.0033 to $0.1161{\mu}g/mL$. In addition, the limit of quantification ranged from 0.0100 to $0.5422{\mu}g/mL$, with a level of precision ranging from 0.21 % to 4.89 % and a degree of accuracy ranging from 89 % to 111 %. The analytical method developed in this study was applied to commercial products.

A Study on the Worst Stress Condition Test Evaluation of Blowers for Small Stationary Fuel Cell System (소용량 건물용 연료전지시스템 블로워의 가혹조건 평가에 관한 연구)

  • Kim, Kangsoo;Lee, Deokkwon;Lee, Jungwoon;Kim, Eunjung;Kim, Inchan;Kim, Younggyu;Shin, Hunyong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.34-40
    • /
    • 2012
  • The fuel cell is one of the renewable energy sources. And it is a new source of energy that can be applied to various fuels and continuously supported by the excellent city-gas infrastructure. It is important to improve performances and reliabilities, and reduce the cost of fuel cell systems for commercialization. And, some safety performances of blower domestically produced are evaluated and some improvements are researched to save the cost of fuel cell systems. In this paper, the performance and worst stress condition of blowers are evaluated in operating environment similar to the fuel cell systems. Actually, the correlation of flow, leakage and thermal behavior are evaluated in the worst stress condition at $70^{\circ}C$ and, some major factors of blower degradation such as a motor deterioration, material and structures of the outlet are examined.

Data Acquisition System Applying TMO for GIS Preventive Diagnostic System (GIS 예방진단시스템을 위한 TMO 응용 데이터 수집 시스템)

  • Kim, Tae-Wan;Kim, Yun-Gwan;Jang, Cheon-Hyeon
    • The KIPS Transactions:PartA
    • /
    • v.16A no.6
    • /
    • pp.481-488
    • /
    • 2009
  • GIS is used to isolate large power electrical equipment using SF6 gas. While GIS has simple structure, it has few break down, relatively high reliability. But it is hard to check up faults for reason of pressure. Faults of GIS should have a ripple effect on community and be hard to recovery. Consequently, GIS imports a preventive diagnostic system to find internal faults in advance. It is most important that reliability on the GIS preventive diagnostic system, because it estimates abnormality of system by analysis result of collected data. But, exist system which used central data management is low efficiency, and hard to guarantee timeliness and accuracy of data. To guarantee timeliness and accuracy, the GIS preventive diagnostic system needs accordingly to use a real-time middleware. So, in this paper, to improve reliability of the GIS preventive diagnostic system, we use a middleware based on TMO for guaranteeing timeliness of real-time distributed computing. And we propose an improved GIS preventive diagnostic system applying data acquisition, monitoring and control methods based on the TMO model. The presented system uses the Communication Control Unit(CCU) for distributed data handling which is supported by TMO. CCU can improve performance of the GIS preventive diagnostic system by guaranteeing timeliness of data handling process and increasing reliability of data through the TMO middleware. And, it has designed to take full charge of overload on a data acquisition task had been processed in an exist server. So, it could reduce overload of the server and apply distribution environment from now. Therefore, the proposed system can improve performance and reliability of the GIS preventive diagnostic system and contribute to stable operation of GIS.

A Study on the Improvement of LNGC Re-liquefaction System (LNG선 재액화 시스템의 성능 개선에 관한 연구)

  • Oh, Cheol;Song, Young-Uk
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.659-664
    • /
    • 2009
  • LNG carriers have, up to 2006, mainly been driven by steam turbines. The Boil-Off Gas from the LNG cargo tanks has so far been used as fuel. This is a costly solution that requires special skills during construction and operation. Alternative propulsion systems offer far better fuel economical efficiency than steam turbines. Instead of previous practice using Boil-Off Gas as a fuel, the Re-liquefaction system establishes a solution to liquefy the Boil-Off Gas and return the LNG to the cargo tanks. This Re-liquefaction of Boil-Off Gases on LNG carriers results in increased cargo deliveries and allows owners and operators to choose the most optimum propulsion system. In this study, thermodynamic cycle analysis has been performed on two type of LNG Re-liquefaction system which was designed and adopted for the Q-Flex(216,000$m^3$) and Q-Max(266,000$m^3$) LNG carrier under construction at Korea ship yards and variable key factor was simulated to compare efficiency, power and nitrogen consumption of each Re-liquefaction system.

Experimental Study on the Effects of Combustion Products on the Human Body and Suggestion of Law Revision (흡음재의 연소 생성물이 인체에 미치는 영향에 대한 실험적 연구 및 법률 개정 제언)

  • Kang, Jung Ki;Choi, Don Mook
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.28-34
    • /
    • 2019
  • Regardless of the ignition source, the main factors affecting the spread of flames to the human body are combustibles. The sound absorption material, which is the finishing material used in music institutes and karaoke rooms, consists of polyurethane that generates a large amount of toxic gas with a high amount of combustion gases during a fire. Still, the current law does not require the use of impregnated finishing materials for tutoring services with less than 100 users. In this study, the rate of flame diffusion was measured using the MultiRaelite composite gas measuring instrument (target substance VOC, HCHO, SO2, CO2, CO, HCN, and NO2) for the collection of sound-absorbing materials installed in the actual music academy. The results showed that the toxic gas found in this experiment exceeded the allowable concentration of TWA (Time Weighted Average) and STEL (Short Term Exposure Limit). In addition, a comparative combustion test of the general sound absorber and non-combustion sound absorbing materials on the market showed wide differences in ignition and diffusion. Therefore, based on the results of the experiment, private institutes with less than 100 users should be mandated to use non-combustion sound absorbing materials.