• Title/Summary/Keyword: 가속주의(加速主義)

Search Result 47, Processing Time 0.019 seconds

Drivers' Workloads through the Driving Vehicle Test at Intersections (교차로 실차주행 실험을 통한 운전자 부하요인에 관한 연구)

  • Seo, Im-Ki;Park, Je-Jin;Sung, Soo-Lyeon;NamGung, Moon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.3
    • /
    • pp.112-123
    • /
    • 2012
  • Different from general roads, intersections are the points where roads having different geometric structure and traffic operation system are met, and thereby they have complicated road structure and environmental factors. Various changes in driving patterns such as collision between vehicles approaching from roads adjacent to intersections, sudden stop of vehicles upon stop sign, quick start upon green lights kept increasing traffic accidents. It is known that traffic accidents are mainly derived from human factors. This study, in order to find out factors affecting drivers' behaviors within intersections, measured physiological responses such as brain wave, sight, driving speed, and so on by using state-of-the-art measuring device. As to concentration brain wave at individual intersections, it was found out that brain wave of testes was higher at main Arterial and accident-prone intersections compared with that of subsidiary Arterial. In addition, it was detected that drivers' visual activity was widely distributed at accident-prone intersections, meaning that it enhanced cautious driving from nearby vehicles. As to major factors causing drivers' workloads, factors from nearby vehicles such as deceleration, acceleration, lane change of nearby vehicles appeared as direct factors causing drivers' workloads, clarifying that these factors were closely related to causes of traffic accidents at intersections. Results of this study are expected to be used as basic data for evaluation of safety at intersections in consideration of physiological response of drivers.

Base Isolation of the 1/3 Scaled RC Building with the Laminated Rubber Bearings (적층고무형 면진 장치를 갖는 철근콘크리트 건물의 면진 특성)

  • Chang Kug-Kwan;Chun Young-Soo;Kim Dong-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.975-982
    • /
    • 2005
  • Scientific community agrees about the fact that base Isolation provides interesting solutions to minimize the seismic risk. Reliability of such a technique is nowadays proofed by a large number of applications like public buildings, nuclear plants, bridges, etc. This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by enterprise in Korea. The shaking table tests were performed using a three story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Especially in this study, effect of earthquake characteristics on response reduction and effect of the intensity of excitations are studied. Through the verification tests, the validity of the applied base isolaion device and the response reduction effect against earthquakes are confirmed.

A Preliminary Study of Roller Types for Chip Seals Construction (Chip Seals 시공을 위한 롤러 종류에 따른 기초적인 연구)

  • Lee, Jae-Jun;Kim, R. Young-Soo
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.79-85
    • /
    • 2010
  • This paper presents a preliminary study of roller types for chip seals based on aggregate retention performance. Chip seal test sections composed of single seals of granite 78M aggregate and CRS-2 emulsion were constructed using three different roller types: the pneumatic tire roller, steel wheel roller, and combination roller. In order to investigate the performance of these rollers effectively, it is critical to test chip seal samples obtained directly from field construction. Therefore, test sections were constructed on New Sandy Hill Church Road near Bailey, North Carolina. Chip seal samples obtained from these sections were used for laboratory testing. The aggregate retention performance was evaluated using the flip-over test (FOT), Vialit test, and the third-scale Model Mobile Loading Simulator (MMLS3). Based on the test results and visual observation, both the pneumatic roller and the combination roller used together are recommended to improve chip seal performance with the sequence of the pneumatic roller rolling first followed by the combination roller.

Inquiring the Possibility of Critical Pedagogy as Discourse for 'Zeitgeist' (시대정신을 위한 교육 담론으로서 비판교육학의 가능성 탐구)

  • Hur, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.80-91
    • /
    • 2019
  • Korean society is now in the 2017 system. The zeitgeist is now hoping to move into a society where the right to pursue happiness centered on democracy, human rights, and peace is recognized, and to the era of the fourth industrial revolution. The paradigm shifts in the education arena began before the start of this socio-political system. The educational autonomy centered on the progressive education superintendent is accelerating the influx of alternative education, which is part of the civic education movement, through public school reforms. It can be seen that not only the progressive camp but also the conservative government emphasized educational policies such as the liberal semester system, which was gradually adopted by the government. For education that is appropriate for a rapidly changing society, it is necessary to discuss about educational grand-discourse that can alternate current public education. Although it does not mean only one discourse, it is a necessary process to systematically consider alternate education of public education and to suggest the direction for future education. In this regard, this study aims to introduce the discourse that can produce critical consciousness and creativity that emphasize the praxis and practice through critical pedagogy and bricolage.

A Study on the Evaluation of the Appropriateness of the Control of Departure of Tugs Based on the Analysis of Ship Dynamic Motion (선체운동 해석 기반의 예인선 출항통제 적정성 평가에 대한 연구)

  • Tae-Hoon Kim;Yong-Ung Yu;Yun-sok Lee;Young-Joong Ahn
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.4
    • /
    • pp.307-315
    • /
    • 2023
  • Korea controls the departure of vessels based on the Maritime Safety Act such that only ships with seaworthiness can navigate in bad weather, but scientific evaluation results and quantitative basis for the designation of ships subject to control are insufficient. Opinions for improvement are being raised for a reasonable departure control operation. The purpose of this study is to evaluate the adequacy of the current departure control standards through actual measurement of tugboats, which are the type of vessels subject to control when a wind and wave advisory is effective, and to present quantitative grounds for improvement of controls. A sensor was installed on the tugboat to measure the ship's three-axis motion and hull acceleration, and the hull motion performance was measured by operating in the sea area with a significant wave height of 3 m. The measured values were compared and analyzed based on seaworthiness evaluation factors and limit value standards. The actual ship was excluded from the current control standard according to tonnage, but as a result of the analysis, the pitch value exceeded the operation standard, and a risk to navigation safety existed. The results of this study suggest the need for additional actual measurement studies that can represent various ship types and specifications and review ship departure control targets.

A Study on the Additional Radiation Exposure Dose of kV X-ray Based Image Guided Radiotherapy (kV X선 기반 영상유도방사선치료의 추가 피폭선량에 관한 연구)

  • Gha-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1157-1164
    • /
    • 2023
  • This study measures the additional dose for each treatment area using kV X-ray based OBI (On-Board Imager) and CBCT (Cone-Beam CT), which have excellent spatial resolution and contrast, and evaluates the adequacy and stability of radiation management aspects of IGRT. The subjects of the experiment were examined with OBI and CBCT attached to a linear accelerator (Clinac IX), and ring-shaped Halcyon CBCT under imaging conditions for each treatment area, and the dose at the center was measured using an ion chamber. OBI single fraction dose was measured as 0.77 mGy in the head area, 3.04 mGy in the chest area, and 7.19 mGy in the pelvic area. The absorbed doses from the two devices, Clinac IX CBCT and Halcyon CBCT, were measured to be similar in the pelvic area, at 70.04 mGy and 70.45 mGy. and in chest CBCT, the Clinac IX absorbed dose (70.05 mGy) was higher than the Halcyon absorbed dose (21.01 mGy). The absorbed dose to the head area was also higher than that of Clinac IX (9.08 mGy) and Halcyon (5.44 mGy). In kV X-ray-based IGRT, additional radiation exposure due to photoelectric absorption may affect the overall volume of the treatment area, and caution is required.

A Comparison of coincidence between the Light field & the Radiation field using film and BIS (필름과 BIS 영상장치를 이용한 광/방사선조사야 일치성 비교평가)

  • Bang, Dong-Wan;Seok, Jin-Yong;Jeong, Yun-Ju;Choi, Byeong-Don;Park, Jin-Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.33-41
    • /
    • 2004
  • Purpose : Film has been the primary tool in coincidence testing between the light field and the radiation field, which constitutes the quality assurance list of a linear accelerator. But there is a great chance of errors being different among the observer when using film. Thus this study set out to use the BIS(Beam Image System) in addition to film in comparing and evaluating coincidence results between the two fields and in searching for the improvement measures. Materials & Methods : Photon beam of 6 and 15MV was exposed to film and the BIS using a linear accelerator. The light and radiation fields were each $50{\times}50,\;100{\times}100,\;and\;200{\times}200mm^2$. The gantry angle was $0^{\circ}$ when using film and $0^{\circ}\;and\;270^{\circ}$ when using the BIS. The devices adopted to test coincidence between the two fields were a ruler and film scanner when using film. With the BIS, the width of the scanned light and radiation fields was measured for errors with setting the X and Y axis. Results : The visual measurements of the observer with film resulted that the radiation field was bigger than the light field and that their maximum error was 1.9mm. The results were the same with the measurements using the film scanner except for the average error, which was less than 1.9mm. On the contrary, the measurements using the BIS showed that the light field was bigger than the radiation field at the gantry angle of $0^{\circ}\;and\;270^{\circ}$. The maximum error was 0.96mm, and the error range was $<{\pm}2mm$ both in the X and Y axis. The average error of ${\Delta}X$, Y was the smallest in the order of the visual film measurements, film scanner measurements, and BIS measurements Conclusion . This requires a careful measurement for accurate quality assurance since errors are much different according to each observer that tests coincidence between visual fields with film. And an observer needs to use another image device or develop a measuring device of his own if it seems necessary for accurate measurements.

  • PDF

A New Understanding on Environmental Problems in China - Dilemma between Economic Development and Environmental Protection - (중국 환경문제에 대한 재인식 -경제발전과 환경보호의 딜레마-)

  • Won, Dong-Wook
    • Journal of Environmental Policy
    • /
    • v.5 no.1
    • /
    • pp.45-70
    • /
    • 2006
  • China has achieved great economic growth above 9% annual since it changed to more of a market economy system by its reform and open-door policy. At the same time, China has experienced severe ecological deterioration, such as air and water pollutions caused by its rapid urbanization and industrialization. China is now confronted with environmental pollution and ecological deterioration at a critical point, at which economic development in China is limited. Moreover, environmental problems in China have become a lit fuse for social fluctuation beyond pollution problems. The root and background of environmental problems in China, firstly, are its government's lack of understanding of these problems and incorrect economic policies affected by political and ideological prejudice. Secondly, the plundering of resources, 'the principle of development first' which didn't consider environmental sustainability is another source of environmental deterioration in China. In addition, a huge population and poverty in China have increased the difficulty in solving its environmental problems, and in fact have accelerated them. The Chinese government has established many environmental laws and institutions, increased environmental investments, and is enlarging the participation of NGOs and the general public in some limited scale to solve its environmental problems. However, it has not obtained effective results because of the lack of environmental investments owing to the government's limit of the development phase, a structural limit of law enforcement and local protectionism, and the limit of political independency in NGOs and the lack of public participation in China. It seems that China remains in the stage of 'economic development first, environmental protection second', contrary to its catch-phrase of 'the harmony between economic development and environmental protection'. China is now confronted with dual pressure both domestically and abroad because of deepening environmental problems. There are growing public's protests and demonstrations in China in response to the spread of damage owing to environmental pollution and ecological deterioration. On the other hand, international society, in particular neighboring countries, regard China as a principal cause of ecological disaster. In the face of this dual pressure, China is presently contemplating a 'recycling economy' that helps sustainable development through the structural reform of industries using too much energy and through more severe law enforcement than now. Therefore, it is desirable to promote regional cooperation more progressively and practically in the direction of building China's ability to solve environmental problems.

  • PDF

The Effect of Pentoxifylline on Radiation-Induced Cardiac Injury in ICR Mice (방사선조사후 발생한 심장손상에서 Pentoxifylline 이 미치는 효과)

  • Suh Hyun Suk;Yang Kwang Mo;Kang Seung Hee;Kang Yun Kyung
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.281-290
    • /
    • 1996
  • Purpose : Chest irradiation leads to a significant cardiac injury in a number of patients. To prevent, or to reduce the risk of radiation-induced cardiac injury, pentoxifylline(PTX), a haemorrheologic agent that improves the blood flow through small blood capillaries has been employed. Materials and Methods : One hundred and eighty ICR mice were divided into three study groups: control, radiation alone, and radiation-pentoxifylline. Each group was subdivided into 12 subgroups: 1 3, 6 and 10 days and 2, 3, 4, 6, 8, 12, 16 and 20 weeks by observation Period after irradiation. The total 15Gy of radiation was delivered in a single fraction through anterior mediastinal port. Pentoxifylline was injected subcutaneously daily 50mg/kg to the back of the mice from the first day of irradiation throughout the observation period. The mice of each group after a certain observation period were sacrificed and sectioned for histopathologic examination of the heart. Result : The findings of acute radiation-induced carditis i.e., heterophilic infiltration and vacuolization and ballooning of endothelial cells were observed upto 6 weeks and reduced sharply afterwards. The late radiation effects including pericarditis with mononuclear cell infiltration, pericardial fibrosis, endothelial cell changes, myocardial degeneration and fibrosis present from 4 weeks onwards after irradiation but with various degree of severity. The overall process of pathologic changes of radiation-pentoxifylline group was similar to those of radiation alone group but the duration of acute stage was relatively short and the severity of late cardiac toxicity was much lesser compared with those of radiation alone group. Conclusion : Pentoxifylline can effectively reduce the late radiation-induced cardiac injury and reslve the acute effects relatively rapidly.

  • PDF

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)