• Title/Summary/Keyword: 가속열화

Search Result 305, Processing Time 0.027 seconds

A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis (수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구)

  • Kim, HongRae;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • This paper presents the integrity evaluation method of the windings in cast resin transformers using vertical thermal distribution analysis. The method is the result from comparing the temperature distribution in a sound condition specimen with that in the failure condition specimen layer-shorted by accelerated testing. The temperature distribution was acquisited by a infrared thermography system, and the Arrhenius equation was adopted to the accelerated testing. The proposed method may be available to detect the failures in cast resin transformers.

A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock (철도차량 견인전동기의 가속열화수명평가 기술현황)

  • Wang, Jong-Bae;Kim, Ki-Jun;Choi, Young-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF

A Study of Electrical and Mechanical Characteristics by Accelerated Life Test (가속수명시험에 의한 변압기 절연재료의 전기-기계적 특성 연구)

  • Kim, Ju-Han;Han, Sang-Ok;Kim, Dae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.28-30
    • /
    • 2007
  • 본 논문은 변압기의 과부하 상태를 모의하고 내부 절연물의 잔존수명을 평가하기 위한 방법으로 열적 스트레스를 인가한 가속 수명 시험을 수행하여 광유 함침 절연지의 전기적 기계적 열화 특성을 분석하였다. 시험에 사용된 절연 재료는 변압기의 주 절연물로 널리 사용하고 있는 셀룰로스계 크래프트 절연지와 광유계 절연유를 사용하였다. 가속 열열화 시험은 IEEE/ANSI Standard C59.91-1981의 수명 예측 곡선에 의거하여 국내 배전환경에 부합하도록 $55^{\circ}C$ 절연시스템을 기준으로 하였으며, $150^{\circ}C$에서 약 1,000시간 동안 열 스트레스를 인가함으로써 변압기의 수명이 다하도록 모의하였다.

  • PDF

Accelerated Deterioration Test Method of High Power Thyristor for HVDC (전력계통용 대용량 사이리스터의 가속열화 시험법)

  • Seo, K.S.;Kim, S.C.;Kim, N.K.;Kim, H.W.;Kim, E.D.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1785-1787
    • /
    • 2003
  • 본 논문에서는 현재 대용량 전력변환 소자인 사이리스터는 해남-제주간의 HVDC변환소에 채용되어 운전중에 있고, BTB 및 SVC등에 채용되고 있으며, 향후 FACTS, 남북 전력계통연계, 동북아 계통연계 등 전력변환용으로 사용될 부품으로 사용범위가 날로 증가하고 있는 2,208개의 사이리스터의 수명 및 신뢰성을 평가하기 위해 고온직류 blocking 가속열화시험조건에 대해서 기술하였다.

  • PDF

Accelerated Aging of Tracking Phenomena Using Weibull Distribution (와이블 분포함수를 이용한 트래킹 현상의 가속열화)

  • Lim, Jang-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.137-138
    • /
    • 2008
  • In this paper, the statistical judgement using IR camera was discussed and investigated. Acceleration experiments were carried out for the possibility of weibull distribution and then, the acquired data were replaced with quantitative value for safety diagnosis of distribution lines.

  • PDF

Changes of Properties and Gas Components according to Accelerated Aging Test of Vegetable Transformer Oil (식물성 절연유의 가속열화에 따른 주요 성분 및 물성 변화)

  • Lee, Donmin;Lee, Mieun;Park, Cheonkyu;Ha, Jonghan;Park, Hyunjoo;Jun, Taehyun;Lee, Bonghee
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.18-26
    • /
    • 2016
  • Mineral oil is the most widely used for electrical transformer, though some factors should be considered such as their environmentally harmfulness when it spill and low flash point. To cover these disadvantages, vegetable oil has developed because of its high biodegradability and thermal stability. However, it is necessary that many studies should conduct to reveal the detailed impacts of long-term operation as transformer oil. In this paper, we applied the accelerated aging test which simulate the real transformer circumstances using insulation paper, coil, steel at $150^{\circ}C$, which is higher than normal operation, for 2 weeks. To figure out the oxidation characteristics between mineral oil and vegetable oil test major properties and components such as total acid number, dielectric breakdown and dissolved gas components during that period. As a result of these tests, we found that vegetable oil has higher electric insulation ability than mineral oil though poor total acid number by hydrophile property. Vegetable oil also kept its thermal stability under the given circumstances.

Study for comparison of storage lifetimes estimation between constant and time-variant variance of degradation data (열화데이터의 등분산 가정에 따른 저장수명예측 비교 연구)

  • Back, Seungjun;Son, Youngkap;Park, Sanghyun;Lee, Munho;Kang, Insik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.154-156
    • /
    • 2017
  • Constant variance of degradation data over time has been generally assumed to estimate storage lifetime using destructive, accelerated degradation data over time. However, performance data of ammunitions deteriorate over time, and the standard deviation would tend to increase over time. This paper shows storage lifetime comparison results for constant variance and time-variant variance assumptions of degradation data over time, and proposes that time-variant variance assumption should be considered to increase accuracy in lifetime estimation.

  • PDF

A Study on the Tracking Characteristics of Silicone Rubber Degraded by Accelerated UV Exposure (자외선 가속열화에 의한 실리콘 고무의 트래킹 특성 변화에 관한 연구)

  • Kim, Suk-Cheol;Lee, Jun-Ho;Hwang, Bo-Seung;Lee, Dong-Yeong;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.5
    • /
    • pp.302-309
    • /
    • 2000
  • The tracking characteristics of silicone rubber degraded by accelerated outdoor exposure employing a weather-o-meter were investigated. The tracking test was performed according to ICE Publ.587 method but the concentration of conductive solution was two times higher than IEC standard in order to accelerate the tracking failure. The number of large effective scintillation and the current of high voltage circuit were measured simultaneously. It was shown that the number of effective scintillation had valuable information of the tracking degradation state of silicone rubber, while the average current between electrodes could not provide information enough for diagnosis. Based upon the experimental results, it could be said that the key factor accelerating tracking failure was not Joule heating by current but pyrolysis by burning of silicone rubber, and that reduction of contact angle was due to chain scission which resulted in the free radicals of low molecules.

  • PDF

고온 및 고온고습 가속시험에 의한 CIGS PV 모듈의 열화거동

  • Lee, Dong-Won;Nam, Song-Min;Kim, Yong-Nam
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.421-421
    • /
    • 2012
  • Cu(In,Ga)$Se_2$ (CIGS) 화합물은 직접천이형 반도체로 열적으로 매우 안정하고 에너지밴드갭이 1.04 eV로 이상적인 값에 가깝고, 특히 높은 광흡수계수를 가지기 때문에 박막 태양전지로서 커다란 응용 잠재력을 갖고 있는 광흡수층 재료이다. CIGS 화합물 박막 태양전지의 효율은 연구실에서는 ~20%를 높은 효율을 보고하고 있으며, 모듈급에서도 ~13%의 효율을 보이고 있다. 그러나 CIGS 박막 태양전지를 대면적 또는 양산화에 적용하기 위해서는 20년 이상의 장기적인 수명을 보장할 수 있는 내구성을 갖추어야 한다. 본 연구에서는 CIGS 모듈의 장기적인 신뢰성을 평가하기 위해 CIGS PV 모듈을 대상으로 대표적인 고온 고습 조건인 IEC-61646 규격을 이용하여 $85^{\circ}C$/85% RH에서 1000시간 동안 가속시험이 수행되었고, 고온 환경하에서 모듈의 성능 저하에 미치는 영향을 고찰하기 위해 모듈을 $85^{\circ}C$에서 1000시간 노출시켰다. 두 종류의 가속 스트레스시험 후에 모듈들의 외형적인 노화현상 및 전기적 열화 성능을 분석하였다. 또한 모듈의 효율저하의 원인을 규명하기 위해 모듈 구성 재료 중 충진재료로 사용하는 EVA sheet와 투명전극 AZO를 대상으로 고장분석을 수행하였다. AZO의 미세구조 관찰, 결정상 분석, XPS 분석 및 전기적 분석과 EVA sheet의 FT-IR 분석과 TG-DSC 분석들을 종합하여 CIGS PV 모듈의 성능저하의 원인을 규명하였다.

  • PDF

Reliability Assessment of Normally-off p-AlGaN-gate GaN HEMTs with Gate-bias Stress (상시불통형 p-AlGaN-게이트 질화갈륨 이종접합 트랜지스터의 게이트 전압 열화 시험)

  • Keum, Dongmin;Kim, Hyungtak
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.205-208
    • /
    • 2018
  • In this work, we performed reverse- and forward-gate bias stress tests on normally-off AlGaN/GaN high electron mobility transistors(HEMTs) with p-AlGaN-gate for reliability assessment. Inverse piezoelectric effect, commonly observed in Schottky-gate AlGaN/GaN HEMTs during reverse bias stress, was not observed in p-AlGaN-gate AlGaN/GaN HEMTs. Forward gate bias stress tests revealed distinct degradation of p-AlGaN-gate devices exhibiting sudden increase of gate leakage current. We suggest that forward gate bias stress tests should be performed to define the failure criteria and assess the reliability of normally off p-AlGaN-gate GaN HEMTs.