• 제목/요약/키워드: 가변형

검색결과 1,164건 처리시간 0.029초

750kW급 Gearless형 국산화 풍력발전시스템 (750kW Gearless Type Wind Turbine Generator System)

  • 류지윤;박진일;김대현;황진수;김두훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.245-248
    • /
    • 2006
  • The first of korean 750kW gearless type wind turbine is developed. The wind turbine is designed, manufactured and tested by GE regulation and obtained the design certificate by GL. And the performance test is being performed at the demonstration site now. This paper presents the history of development and performance test for 750kW gearless type wind turbine.

  • PDF

KBP-2000M 풍력발전기용 영구자석형 동기발전기의 냉각시스템 설계 (Cooling System Design of PM Synchronous Generator for KBP-2000M)

  • 이홍기;김동언;서형석;한홍식;정영규;이월우;박기현;정진화
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.315-318
    • /
    • 2006
  • 포항풍력에너지연구소에서는 에너지 관리공단의 지원으로 2004년부터 풍력터빈 KBP-2000M에 사용될 발전기를 개발해 오고 있다. KBP-2000M에 사용되는 발전기는 기어비가 24인 기어박스를 가진 가변속도형식의 발전기이다. 발전기의 직경은 1.87m 이고 축 방향의 길이는 1.288m 로 영구자석을 사용하여 여자하는 형식으로 설계되었다. 이러한 설계는 풍력발전기에서 요구하는 주요 요구조건인 고효율, 고 신뢰성을 만족시키기 위해서 매우 중요하다 이 보고에서는 발전기의 물리설계에서 얻어진 사양을 기준으로 하여 열 해석에서 얻어진 열 손실을 이용하여 냉각시스템 설계를 하였으며 펌프 및 라디에이터 선정에 관해서 논의한다.

  • PDF

ECG 신호에 기반한 효과적인 알고리즘의 연구 (A study on an effective algorithms based on ECG signal)

  • 이현주;신동일;신동규
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2010년도 한국컴퓨터종합학술대회논문집 Vol.37 No.1(C)
    • /
    • pp.230-234
    • /
    • 2010
  • 심전도는 가장 일반화되어 있는 생체신호의 하나이다. 심전도를 측정하여 심장병의 유무와 여러 질환들을 예측하고 예방할 수 있다. 심전도 신호를 추출 하는 방법에는 여러 방법이 있는데, 본 논문에서 활용한 두 논문은 계층적인 분류로 HOS, HBF, HMH 세 방법으로 실험을 하였고, 적응가변형 윈도우를 이용한 R파 추출을 실행하였다. 두 논문은 공통적으로 MIT-BIH Arrhythmias Database(MIT-BIT 부정맥 데이터베이스)를 데이터로 실험 하였으며, 알고리즘으로는 SVM, Cross-Validation등을 사용하였다. 마지막으로 두 논문의 실험결과를 바탕으로 정확도를 높일 수 있는 효과적인 알고리즘 연구를 제안하였다.

  • PDF

가변 파장형 적외선 가스 센서에 의한 생체표지자 분석 (Analysis of biomarkers with tunable infrared gas sensors)

  • 이승환
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.314-319
    • /
    • 2021
  • In this study, biomarkers were analyzed and segmented using tunable infrared gas sensors after performing the principal component analysis. The free spectral range of the device under test (DUT) was around 30 nm and DUT-5580 yielded the highest output voltage property among the others. The biomarkers (isoprophyl alcohol, ethanol, methanol, and acetone solutions) were sequentially mixed with deionized water and their mists were carried into the gas chamber using high-purity nitrogen gas. A total of 17 different mixed gases were tested with three tunable infrared gas sensors, namely DUT-3144, DUT-5580, and DUT-8010. DUT-8010 resolved the infrared absorption spectra of whole mixed gases. Based on the principal component analysis with each DUT and their combinations, each mixed gas and the trends in increasing gas concentration could be well analyzed when the contributions of the eigenvalues of the first and second were higher than 70% and 10%, respectively, and their sum was greater than 90%.

C-rate의 가변성에 따른 고출력 직렬 배터리팩의 셀 간 전압 불균형 비교분석 (Comparison of Cell-to-Cell Voltage Imbalance of High-Power Serial Battery Pack with Variability of C-rate)

  • 김승우;이평연;한동호;박진형;김우용;김종훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.125-126
    • /
    • 2018
  • 본 논문에서는 원통형 NCA 리튬이온 배터리로 제작된 고출력 직렬조합 배터리팩으로 C-rate에 따른 전기적 특성 실험을 수행하였다. 방전 용량 프로파일 실험을 통해 배터리팩의 충/방전 C-rate가 배터리팩의 내부 파라미터에 어떠한 영향을 주는지 비교 분석한다. 실험을 통해 방전 용량과 전압 편차 파라미터를 측정한다. 전압 편차 그래프는 만방 구간과 만방 이후 휴지 구간의 셀 간 전압 편차를 중심으로 관찰하며 두 구간의 전압 편차를 비교한다. 3가지 파라미터를 비교하여 가장 효율적인 C-rate를 알아보았다.

  • PDF

외부공진형 광주파수가변 레이저를 이용한 실시간 광섬유 케이블의 미세 진동 측정 연구 (Real-time Subtle Vibration Sensing of Optical Fiber Cable based on External-cavity Frequency-swept Laser)

  • 장한솔;김창석
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.943-948
    • /
    • 2020
  • In this paper, we developed a fiber optic interferometer system based on frequency-swept laser. This frequency-swept laser with an external-cavity structure can generate a high coherent light with a linewidth of 132 kHz at 1552 nm. It also shows a superior swept linearity of R2 = 0.99995 under repetition rate of 200 kHz due to absence of mechanical moving parts in the laser cavity. By using a piezoelectric fiber optic stretcher, various vibration experiments were implemented, such as 0.5 to 2.0 kHz vibration signals with intervals of 0.5 kHz, with a sampling rate of 7 kHz. Real-time peak tracking can be successfully recovered according to the applied vibration frequency with high linearity of R2 = 0.99983.

가변용량형 사판식 피스톤 펌프의 구조해석 및 성능시험 (Structural Analysis and Performance Test of Variable Displacement Swash Plate Piston Pumps)

  • 이정실;전차수
    • 한국기계가공학회지
    • /
    • 제21권7호
    • /
    • pp.105-113
    • /
    • 2022
  • In this study, a variable displacement swash plate pump supplying high-pressure hydraulic oil to control the hydraulic system of a marine engine was developed. A structural analysis was performed on the main parts of the pump to ensure the structural safety in the design. Using a pump testing equipment, performance characteristics such as no-load flow rate, load flow rate, flow rate according to the swivel angle change, flow rate with lubrication orifice, and response time according to the swivel motion were tested. Consequently, the pump was confirmed to satisfy the required specifications.

가변 인덕터를 적용한 2상 인터리브드 벅 컨버터의 전류 불평형 저감에 관한 연구 (A Study on the Reduction of Current Unbalancing of Two-phase Interleaved Buck Converter using Variable Inductor)

  • 임재성;차헌녕
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.417-424
    • /
    • 2022
  • This study proposes a current-balancing technique for an interleaved buck converter using a variable inductor and a snubber capacitor. The proposed scheme balances the inductor current by using the variable inductor and enables zero voltage switching under all load ranges. With the variable inductor, the ripple of inductor current changes according to load variation. In addition, a 1.6 kW prototype is built to verify the validity of the proposed scheme, and the experimental results are successfully obtained.

가변 파장형 적외선 센서를 이용한 변압기 결함 진단 (Fault Analysis of Transformer using Tunable Infrared Gas Sensors)

  • 이근호;이승환
    • 센서학회지
    • /
    • 제32권1호
    • /
    • pp.55-61
    • /
    • 2023
  • The objective of this study is to determine the concentrations of mixed gases by establishing a diagnosis method of a transformer using tunable-wavelength optical infrared sensors. Absorption of infrared light by methane, acetylene, and ethylene gases injected is measured from the outputs of the infrared sensors. Regression analysis equations of the gas concentrations are acquired from their respective measured absorption. The obtained concentrations are as follows: -3-9 % errors above 600 ppm(methane), 3 % errors above 1200 ppm(acetylene), and 10 % errors above 500 ppm(ethylene). The concentration inference equations obtained using the individual gases are applicable when the absorption wavelength bands do not overlap. The results of the fault analysis of a transformer using the Duval triangle method and the tunable infrared gas sensors are as follows: temperature faults with -1-1% errors and energy faults with -7-7 % errors.

역기전력을 이용한 2MW급 가변속 풍력터빈용 영구자석 동기기의 센서리스 제어 (Sensorless Control Using the Back EMF of PM Generator for 2MW Variable Speed Wind Turbine)

  • 임지훈;오상근;송승호;이현영;권오정;장정익;이권희
    • 풍력에너지저널
    • /
    • 제2권2호
    • /
    • pp.54-60
    • /
    • 2011
  • A PMSG in variable speed wind turbine needs to know the position of rotor for vector control. Since the position sensor has the disadvantage in terms of cost, complexity of the system, a sensorless algorithm is needed. The sensorless strategy using the back EMF estimation is used for PMSG Wind Turbine. This algorithm is comparatively easy to implement than other strategies. This paper introduces the application of stable sensorless control for 2MW direct drive PMSG. In order to confirm the sensorless algorithm, the implementation is proceeded using 2MW direct drive PMSG from no-load condition to full-load condition. To drive 2MW PMSG artificially, 2MW PMSG connected PMSG through the mechanical coupling.